• Title/Summary/Keyword: Profile loss

Search Result 534, Processing Time 0.024 seconds

Improvement and Verification of the Wear Volume Calculation

  • Kim, Hyung-Kyu;Lee, Young-Ho
    • KSTLE International Journal
    • /
    • v.6 no.1
    • /
    • pp.21-27
    • /
    • 2005
  • A technique for a wear volume calculation is improved and verified in this research. The wear profile data measured by a surface roughness tester is used. The present technique uses a data flattening, the FFT and the windowing procedure, which is used for a general signal processing. The measured value of an average roughness of an unworn surfnce is used for the baseline of the integration for the volume calculation. The improvements from the previous technique are the procedures of the data flattening and the determination of a baseline. It is found that the flattening procedure efnciently manipulates the raw data when the levels of it are not horizontal, which enables us to calculate the volume reasonably well and readily. By comparing it with the weight loss method by using artificial dents, the present method reveals more volume by aroung 3~10%. It is attributed to the protruded region of the specimen and the inaccuracy and data averaging during the weght loss measurement. From a thorough investigation, it is concluded that the present technique can provide an accurate wear volume.

Measurement and Analysis of Propagation Characteristics in Curved Subway Tunnel Environments (곡선형 지하철 터널환경에서 전파 특성의 측정과 분석)

  • 정회동;박노준;강영진;송문규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8A
    • /
    • pp.950-961
    • /
    • 2004
  • In this paper, we measured and analyzed propagation characteristics in a subway tunnel that is recently increasingly becoming one of the radio communication environments. The measurements are carried out in a subway tunnel with frequency bands of 2.45㎓ and 5.8㎓. The length of tunnel we used for this study is 175m of LOS (Line-of-sight) and 270m of NLOS (Non Line-of-Sight). The subway tunnel is curved and its cross section is horseshoe type. The measurement systems we employ in this study are a narrow-band system and a wide-band system. The narrow-band system is used to get path loss measurement and the wide-band system is used to figure out delay profile measurement. In particular, the wide-band system consists of 1023 length PN sequence generator using a chip rate of 80MHz based on a sliding correlation technique. The omni-directional antennas and directional antennas are used to analyze propagation characteristics for beam type of antenna. The path loss displays only pure path loss of a tunnel environment. The delay profile indicates the mean excess delay and RMS (root mean square) delay spread.

Effects of Ulinastatin on Postoperative Blood Loss and Hemostasis in Atrioventricular Valve Surgery with Cardiopulmonary Bypass

  • Park, Jae Bum;Kim, Seong Hyop;Lee, Song Am;Chung, Jin Woo;Kim, Jun Seok;Chee, Hyun Keun
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.185-191
    • /
    • 2013
  • Background: Cardiopulmonary bypass (CPB) induces variable systemic inflammatory reactions associated with major organ dysfunction via polymorphonuclear neutrophils (PMNs). Ulinastatin, a urinary trypsin inhibitor, inhibits PMN activity and reduces systemic inflammatory responses. The aim of this study is to evaluate the effect of ulinastatin on postoperative blood loss and laboratory changes in patients undergoing open heart surgery. Materials and Methods: Between January 2008 and February 2009, 110 patients who underwent atrioventricular valve surgery through right thoracotomy were divided into two groups. Patients received either 5,000 U/kg ulinastatin (ulinastatin group, n=41) or the equivalent volume of normal saline (control group, n=69) before aortic cross clamping. The primary end points were early coagulation profile changes, postoperative blood loss, transfusion requirements, and duration of intubation and intensive care unit stay. Results: There were no statistically significant differences between the two groups in early coagulation profile, other perioperative laboratory data, and postoperative blood loss with transfusion requirements. Conclusion: Administration of ulinastatin during operation did not improve the early coagulation profile, postoperative blood loss, or transfusion requirements of patients undergoing open heart surgery. In addition, no significant effect of ulinastatin was observed in major organs dysfunction, systemic inflammatory reactions, or other postoperative profiles.

Design of Double-clad, Dispersion-Compensated Fiber at$\lambda=1.55\mu\textrm{m}$ : Step & Triangular Index Profile ($\lambda=1.55\mu\textrm{m}$에서 계단형, 삼각형 분포-이중클래드 분산보상 광섬유의 설계)

  • 김수아;김창민
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.11
    • /
    • pp.54-63
    • /
    • 1997
  • The 1-D finite-element mehtod is applied for designing double-clad otpical fibers with dispersion-compensation capability. design parameters allowing only a $LP_{01}$ single mode are treated and macro-bending loss are taken into consideration. Design parameters are extracted to have the compensation ratio $(L_{SMF}/L_{DCF})$ of 6.2 for core structure with step-index profile, and of 5.2 for core with triangular-index profile.

  • PDF

Influence of Manufacturing Tolerance on the Aerodynamic Characteristics of Axial Compressor Blades - 1. Distortion of Blade Profile Curvatures (축류 압축기 날개의 제작 공차가 공력 특성에 미치는 영향- 1. 날개 형상 곡률 변형)

  • Sohn, Jeong L.;Kang, Dong Jin;Jun, Hyun Joo;Kang, Shin-Hyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.30-36
    • /
    • 1999
  • Blade shape profile in the axial compressor is one of the most important factors governing its aerodynamic characteristics. Manufacturing tolerance, which is inevitable in the blade manufacturing processes, may change blade profile and as a consequence, it will affect the compressor performance. In this paper, influence of manufacturing tolerance on the aerodynamic characteristics of axial compressor blades with distortion of blade profile curvatures is investigated by using a flow simulation technique. It is found that manufacturing tolerance can be an important factor affecting the source of both profile and wake losses of the axial compressor blades.

  • PDF

THE EFFECT OF NITI ROTARY INSTRUMENTATION ON THE CONFIGURATION OF APICAL ROOT CANAL (NiTi Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향)

  • Oh, Hyun-Jung;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.244-253
    • /
    • 1997
  • During preparation of narrow curved canals, procedural accidents such as, ledge, zipping, and transportation are frequently encountered and may lead to failure of endodontic therapy. To reduce these procedural errors and efficiently manage curved canals, various modifications in instrumentation technique and the design and flexibility of instruments have been advocated. This study compared the maintenance of the original canal curvature, cross sectional canal shape, and preparation time during instrumentation with stainless steel hand (K-Flexo) file, and nickel-titanium rotary files (Profile and Lightspeed). Thirty resin blocks with simulated curved canals of 20~25 degrees were used and divided into three groups of 10 each. In group 1, canals were instrumented using a quarter turn/pull technique with K-Flexofiles. Group 2 canals were prepared with rotary NiTi Profiles. Group 3 was prepared with rotary NiTi Lightspeed instrument. Before and after instrumentation, all canals were scanned using stereo microcope, FlexCam camera, and Photoshop 3.0 computer program. The results were as follows : 1. All groups showed some loss of canal curvature after instrumentation. Average loss of canal curvature was 8.6 degrees for K-Flexofile, 7.7 degrees for Profile, and 5.8 degrees for Lightspeed. Lightspeed exhibited significantly less curvature loss than K-Flexofile (p<0.05). 2. At the apical 1-mm level, Profile produced significantly rounder canals than Lightspeed (p<0.05). At the 3-mm level, Profile and Lightspeed exhibited significantly rounder canals than K-Flexofile (p<0.05). 3. Preparation with Lightspeed was significantly faster than Profile and K-Flexofile, and Profile was faster than K-Flexofile (p<0.05). 4. There was no significant difference in incidence of zipping between the hand K-Flexofile and rotary NiTi (Profile and Lightspeed) instruments. Most of apical canals were slightly widened near the apical foramen. As a results of this study, rotary NiTi instruments are superior to the K-Flexofile in regard to the maintenance of original canal curvature, cross-sectional shape and preparation time. But more investigations and studies should be needed to evaluate the ideal canal instrumentation.

  • PDF

The Optimal Design of POF Optical Connector for Medical Image Transmission System (의료영상전송시스템을 위한 POF 광커넥터의 최적 설계)

  • Cheon, Min-Woo;Cho, Kyung-Jae;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.978-982
    • /
    • 2010
  • For mass information transfer, the optical communication using optic fiber has been widely used. Especially, in the field of medical image, the large data is digitalized based on the standard image and it is used for telemedicine with this method. Therefore, to transfer the large amount of data fast and effectively POF (Plastic Optical Fiber) can be used and the development of optic connector for connection between POFs is very important. In this study, for stable optical coupling of POF optic fiber Ferrule and Sleeve were designed and produced by considering the bond stability and the insertion loss according to the physical contact and roughness profile was evaluated. As a result of examining the insertion loss by physical contact method of two optic fibers, it showed the loss was about 1.895dB. According to the results from studying the condition of grinding section for POF mass production, the mass production condition was established as POF profile roughness of 6nm and the loss of 0.2dB or lower by controlling the film size and time step by step.

Profile of chronic and aggressive periodontitis among Senegalese

  • Benoist, Henri Michel;Seck-Diallo, Adam;Diouf, Abdoulaye;Yabbre, Salama;Sembene, Malick;Diallo, Papa Demba
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.6
    • /
    • pp.279-284
    • /
    • 2011
  • Purpose: To describe the profile of chronic and aggressive periodontitis among Senegalese (West Africans) attending the Institute of Dentistry of Dakar. Methods: A retrospective study was conducted with an inclusion period running from 2001 to 2008. The sample included 413 chronic periodontitis and 151 aggressive periodontitis cases, among them 299 males and 265 females selected from 2,274 records. A Student's independent t-test or Pearson chi-squared test was used for data analysis. Results: The proportion of females with aggressive periodontitis was significantly higher than those with chronic periodontitis (64.9% vs. 40.4%, P<0.001). The aggressive periodontitis patients had an average age of $28.1{\pm}8.9$ years, and had lost less than 3 teeth. Less than a third of them reported using a toothbrush. Attachment loss was as high as 8 mm and severe lesions had spread to an average of 12 teeth with maximum alveolar bone loss up to 80%. The chronic periodontitis patients had an average age of $44.9{\pm}14.0$ and had lost on average less than 3 teeth. Nearly 75% used a toothbrush. Attachment loss was significantly higher and lesions were more extensive in the aggressive periodontitis. Chronic periodontitis is associated with risk factors such as smoking or diabetes mellitus in 12.8% versus 0.7% in aggressive periodontitis (P<0.001). Differences between the two groups for most clinical and radiographic parameters were statistically significant. Conclusions: The profile of aggressive periodontist is characterized by more severe lesions than chronic periodontitis, whereas tooth loss experience is similar in both forms.

An Experimental Study on Ducted Silencers I (ISO 7235) (덕트 소음기의 실험적 연구 I (ISO 7235))

  • 남경훈;박희주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.282-287
    • /
    • 2001
  • The test facility has been manufactured to predict the dynamic insertion loss and the pressure drop for ducted silencers based on ISO 7235. The qualification test of the test facility is necessary for determining the dynamic insertion loss and the pressure drop of the test silencer, and is surveyed the reflection coefficient for an anechoic termination, the velocity profile near the upstream connection to the test silencer, the reduction of the system silencer and the limiting insertion loss due to the flanking sound transmission along the duct walls.

  • PDF

FORMATION OF LINE PROFILES BY THE WINDS OF EARLY TYPE STARS

  • KANG IVIIN-YOUNG;KIM KYUNG-MEE;CHOE SEUNG-URN
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.263-264
    • /
    • 1996
  • We have solved the radiative transfer problem using a Sobolev approximation with an escape probability method in case of the supersonic expansion of a stellar envelope to an ambient medium. The radiation from the expanding envelope turns out to produce a P-Cygni type profile. In order to investigate the morphology of the theoretical P-Cygni type profile, we have treated $V{\infty},\;V_{sto},\;{\beta}$ (parameter for the velocity field), M and $\epsilon$ (parameter for collisional effect) as model parametrs. We have found that the velocity field and the mass loss rate affect the shapes of the P-Cygni type profiles most effectively. The secondarily important factors are $V{\infty},\;V_{sto}$. The collisional effect tends to make the total flux increase but not so .much in magnitude. We have infered some physical parameters of 68 Cyg, HD24912, and $\xi$ persei such as V$\infty$, M from the model calculation, which shows a good agreement with the observational results.

  • PDF