• 제목/요약/키워드: Product Assessment

검색결과 833건 처리시간 0.029초

상수관망의 자가세척 유속과 적정 플러싱 유속 평가 (The assessment of self cleaning velocity and optimal flushing velocity in water distribution system)

  • 배철호;최두용;김주환;김도환
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.441-451
    • /
    • 2014
  • The flushing is important to maintain good water quality in water main. It is a technique of using water velocity to remove sediments in water distribution system. The variety of water quality problems can occur in a distribution system, so too can a variety of benefits be gained by system flushing. In order to effectively perform the flushing, the contaminants to be removed to set up and it can be solved, it is necessary to ensure the proper flow rate. In this study, the removal of contaminants present in the inner water pipe attached loose deposits such as fine particles of granular activated carbon, sand and iron corrosion product sought to derive flow rates. Thus, the constant observation of using pilot plant scale water distribution plant for the movement of floating characteristics of particles were assessed.

KOMPSAT Data Processing System: Preliminary Acceptance Test Results

  • Kim, Yong-Seung;Kim, Youn-Soo;Lim, Hyo-Suk;Lee, Dong-Han;Kang, Chi-Ho
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.331-336
    • /
    • 1999
  • The optical sensors of Electro-Optical Camera (EOC) and Ocean Scanning Multi-spectral Imager (OSMI) aboard the Korea Multi-Purpose SATellite (KOMPSAT) will be placed in a sun synchronous orbit in 1999. The EOC and OSMI sensors are expected to produce the land mapping imagery of Korean territory and the ocean color imagery of world oceans, respectively. Utilization of the EOC and OSMI data would encompass the various fields of science and technology such as land mapping, land use and development, flood monitoring, biological oceanography, fishery, and environmental monitoring. Readiness of data support for user community is thus essential to the success of the KOMPSAT program. As part of testing such readiness prior to the KOMPSAT launch, we have performed the preliminary acceptance test for the KOMPSAT data processing system using the simulated EOC and OSMI data sets. The purpose of this paper is to demonstrate the readiness of the KOMPSAT data processing system, and to help data users understand how the KOMPSAT EOC and OSMI data are processed and archived. Test results demonstrate that all requirements described in the data processing specification have been met, and that the image integrity is maintained for all products. It is however noted that since the product accuracy is limited by the simulated sensor data, any quantitative assessment of image products can not be made until actual KOMPSAT images will be acquired.

  • PDF

NIR DIODE ARRAY SPECTROMETERS ON AGRICULTURAL HARVEST MACHINES OVERVIEW AND OUTLOOK

  • Rode, Michael
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1172-1172
    • /
    • 2001
  • Compact Near Infrared Diode Array Spectrometers offer new possibilities for on line quality assurance in the agricultural sector. Due to their speed and complete robustness towards temperature fluctuations and mechanical shock Diode Array Spectrometers are suitable for the use on Agricultural Harvest Machines. The growing consumer consciousness of food quality in combination with falling manufacturing prices demands procedures for an effective quality control system. The various conventional types of NIR instruments which have so far been used in laboratories are unsuitable for mobile applications under the rough conditions of field cropping not only because of their slow speed of measurement but also because of their shock sensitive filter wheels and monochromators necessary for fractionating polychromatic light. Another advantage of the on line use is the reduction of the sampling error because of the continuously measurement of the whole product. Considering the large economic importance of the dry matter content on agricultural products it is of particular advantage that water belongs to those constituents which are most easily assessed in the near infrared. While other constituents of economic importance such as starch, oil and protein in grains and seeds have a much lesser effect on NIR signals, their contents can nonetheless be assessed with high analytical precision on freshly harvested grains and seeds. In the last years several applications for on line quality assessment on harvesting machines were developed and tested. The talk will give an overview and outlook on existing and future possibilities of this new field of NIR applications.

  • PDF

약침용(藥鍼用) 봉독액(蜂毒液)의 국소독성시험(局所毒性試驗)에 관(關)한 연구(硏究) (A Study on Local Irritation Test of Bee Venom for Herb-Acupuncture)

  • 이종석;고형균;김창환
    • 대한한의학회지
    • /
    • 제16권1호통권29호
    • /
    • pp.227-249
    • /
    • 1995
  • Pursuant to the Medical Product Safety Administration Guidelines for safety assessment of Korean bee vonom for herb-acupuncture, rabbits were used for skin, eye balls, subcutaneous and muscle irritation test. The results were as follows; 1. The skin irritation test of bee venom for herb-acupuncture did not produce any irritation reactions, when the skin was covered with bee venom. 2. The eye irritation test produced moderate to severe stimulating reactions, once the eye mucous membrane was contacted with bee venom. 3. The subcutaneous and muscle irritation test of bee venom showed such local inflammatory reactions as death of cells, infiltration of inflamed cells, dropsical swelling, and congestion, once injected under the skin and in the muscle. As the results of the study on bee venom for herb-acupuncture indicate that severe reactions in such tests as eye balls, subcutancous and muscle irritation exist in the laboratory, more professional caution should be taken in clinical application of the therapy. In addition, further study on subacute, chronic toxicity and allergy reactions should be pursued.

  • PDF

뇌졸중 환자의 체간조절 능력과 동적균형 및 보행과의 상관관계 (The Relationships among Trunk Control Ability, Dynamic Balance and Gait in Stroke Patients)

  • 정은정;이종수;김성식;이병희
    • 대한한의학회지
    • /
    • 제33권1호
    • /
    • pp.148-159
    • /
    • 2012
  • Objectives: This study investigated the correlation among Postural Assessment Scale for Stroke (PASS), Timed "Up and Go" Test (TUG) and gait (velocity, cadence, step-length, stride-length and single-limb support). Methods: The 70 subjects were assessed on trunk control measured with the use of the PASS, dynamic balance (TUG) and gait function (by GAITRite). The data were analyzed using Pearson product correlation. Results: The PASS total scores were significantly correlated with PASS-M, PASS-C, and PASS-T (r =.80 ~ .88 p<.01). All items of the PASS were significantly correlated with TUG (r = -.63 ~ -.81 p<.01), velocity (r = .44~.58 p<.01), cadence (r =.38 ~.51. p<.01), affected side step length (r = .44 ~.56 p<.01) and affected side stride length (r = .45 ~.59 p<.01). But affected side single-limb support was lowly correlated with PASS-M, PASS-C, PASS-T and PASS-total (r = .25~.36 p<.05). Conclusions: Measures of trunk control were significantly related with values of dynamic balance and gait. Based on these results, trunk control is an essential core component of balance and gait. Trunk control training programs after stroke should be developed and emphasized.

비이식형 요실금 치료용 신경근 전기자극 의료기기 개발 (The Development of Neuromuscular Electrical Stimulation Medical Devices for The Treatment of Non-implantable Urinary Incontinence)

  • 이재용;이창두;권기진
    • 전기학회논문지P
    • /
    • 제64권3호
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, the neuromuscular electrical stimulation medical devices for non-implantable incontinence treatment other than vaginal insertion type was developed and commercialized. The structure of medical devices for electrical stimulation based on the anatomy of the pelvic floor muscle designed. Then, the optimum parameters that may be effective in pelvic floor muscle electrical stimulation was set. The circuit system based on the optimum parameters were designed and manufactured. The frequency of the pulse voltage for electrical stimulation is 75[Hz], the pulse width is 300[${\mu}s$], the development of medical devices was to have seven program functions to the various treatments. The circuit system of medical devices was composed of microcontroller, comparator and converter. The performance of the developed circuit system in KTC(Korea Testing Certification) were carried out medical equipment inspection test. Test results, test specifications were satisfied with the medical device, the performance was verified to be commercialized as a medical device. The development of medical devices were validated risk assessment and product performance through a software validation. Commercialization of medical equipment was acquired to enable the certification standards of the international standard IEC 60601-1.

CAD 모델 기반 비접촉 기상 측정에 관한 연구 (Non-contacting OMM (On Machine Measurement) based on CAD Model)

  • 권세진;이정근;박정환;고태조;김선호
    • 한국정밀공학회지
    • /
    • 제20권11호
    • /
    • pp.134-141
    • /
    • 2003
  • An industrial product is designed and fabricated, followed by the inspection process in order to check whether it is dimensionally tolerable or not. The machining process produces a part such as a mold or die, in which the three-dimensional coordinate might be measured by a CMM (Coordinate Measuring Machine) for assessment of its dimension. It is not ignorable, however, that a CMM measurement requires a lot of operating time and cost, which has led to many studies on the OMM system. The OMM system can be categorized into contact and non-contact types, and each of which has its own strengths and weaknesses. Non-contacting types generally utilize structured lights, sounds or magnetic fields. Though they show rather poor performance in positional accuracy, the measuring speed is faster than the contacting probes. This paper presents the development of an OMM system based on a non-contacting laser displacement sensing apparatus and CAD model. The system is composed of software modules of center-aligning and measuring, which has been operated and verified on a NC machining center on a shop floor.

The Current Status and Acceptance of Traditional Medicine of East Asia in the UK

  • Lee, Hai Woong
    • 대한예방한의학회지
    • /
    • 제20권2호
    • /
    • pp.87-95
    • /
    • 2016
  • Objectives : Traditional medicine(TM) of East Asia has been taking its status as part of complementary and alternative medicine(CAM) in the UK. However, the efficacy and safety issues make it hard to be accepted in the healthcare system. The aim of the research is to find out the current status of TM of East Asia in the UK and to discuss some issues around its acceptance as formal healthcare method. Methods : Articles, books and regulations related to the acceptance of TM of East Asia were analysed and the internet websites were visited such as Westlaw UK for legal materials, government websites for formal documents, and some UK-based associations. Keyword searches were followed and the essential parts from the articles and documents were generalised for the analysis and discussion. Results : Issues over TM of East Asia include identity as medicine, efficacy and safety, and the statutory regulation can be a measure for the acceptance. Osteopathy and chiropractic therapies came under statutory regulation among the CAM in the UK. Conclusions : TM of East Asia could be under the statutory regulation in the near future. Efficacy and safety issues are the challenging barrier. However, the approach from the viewpoint of TM of East Asia is necessary for development and good practice. The simplified registration procedure for traditional herbal medicinal product in EU can be the model. Education, evaluation, assessment and managing quality of practice are essential for the standard care and formal regulation.

Methylthioisocyanate 합성반응 공정의 열적위험 특성 (Characteristics of Thermal Hazard in Methylthioisocyanate Synthesis Reaction Process)

  • 한인수;이근원;이주엽
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.77-87
    • /
    • 2012
  • Compared to a batch reactor, where all reactants are initially charged to the reactor, the semi-batch reactor presents serious advantages. The feed of at least one of the reactants provides an additional way of controlling the reaction course, which represents a safety factor and increases the constancy of the product quality. The aim of this study was to investigate the characteristics of thermal hazard such as a feed time, catalysis concentration and solvent concentration in methylthioisocyanate(MTI) synthesis reaction process. The experiments were carried out by the Multimax reactor system and Accelerating rate calorimeter(ARC). The MTI synthesis reaction process has many reaction factors and complicated reaction mechanism of multiphase reaction. Through this study, we can use as a tool for assessment of thermal hazard of other reaction processes by applying experiment method provided.

터널 배면공동 뒤채움재 개발과 노후터널의 적용에 관한 연구 (A study on development of the high-flowable filling material and application in the old tunnel)

  • 마상준;서경원;배규진;안상철;임경하
    • 한국터널지하공간학회 논문집
    • /
    • 제4권3호
    • /
    • pp.195-205
    • /
    • 2002
  • 터널에서의 배면공동은 설계 시공 유지관리중 다양한 원인들이 복합적으로 작용하여 발생하게 된다. 특히, 터널 천단부 라이닝 부분에는 콘크리트 타설후 재료분리 등으로 인해 터널 천단부에 배면공동이 발생이 되는데, 이러한 터널 배면공동은 라이닝 균열, 누수 등과 밀접한 연관이 있는 것으로 밝혀지고 있다. 본 연구는 석산에서 발생되는 석분을 이용하여 터널 배면공동 및 지하공동의 충전용 모르타르를 개발하고 이를 노후터널에 적용함으로서 개발재료의 현장적용성 등에 대한 시험을 수행하였다.

  • PDF