• Title/Summary/Keyword: Process tomography

Search Result 373, Processing Time 0.027 seconds

The Preclinical Study of Hyeolbuchugeo-tang (Xuefuzhuyu-tang) on Bone Healing in Rats with Rib Fracture (골절 유발 Rat에 대한 혈부축어탕(血府逐瘀湯)의 전임상 연구)

  • Huh, Gun;Oh, Min-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.3
    • /
    • pp.23-44
    • /
    • 2020
  • Objectives The purpose of this study is to evaluate the healing effect of Hyeolbuchugeo-tang (HC) in rats with rib fracture. Methods Rats were randomly divided into 5 groups (naive, control, positive control, HC-L and HC-H). All groups except naive group were subjected to bone fracture of rib. Naive group received no treatment at all. Control group was fed with phosphate buffered saline. Positive control group was orally medicated with tramadol. Experimental group was orally medicated with HC extract (50 mg/kg for low concentration [HC-L], 100 mg/kg for high concentration [HC-H]). X-ray and micro-computed tomography (micro-CT) were conducted to assess the effect of HC. We analysed the level of 2) transforming growth factor-β1 (TGF-β1), Ki67, alkaline phosphatase (ALP), receptor activator of nuclear factor kappa-β, runt-related transcription factor 2 (Runx2) and tartrate resistant acid phosphatase (TRAP) on 7 and 14 days after fracture. ALP, alanine aminotransferase, aspartate aminotransferase, blood urea nitrogen, creatinine was measured for safety assessment. Results X-ray and micro-CT, showed HC enhance bone repair process. Callus formation was increased in experimental group at 7 days after fracture, but decreased at 14 days after fracture. 7 days after fracture, the level of TGF-β1 in experimental group was decreased. The level of Ki67, Runx2 in HC-H, TRAP in HC-L was increased. 14 days after fracture, the level of Ki67 in HC-L and HC-H was decreased. The level of ALP, Runx2, BUN in HC-L, TRAP in HC-L and HC-H was increased. Conclusions Taken together the results, HC promoted healing of bone fracture. In conclusion, HC has a potential to promote healing of bone fracture.

A Case of Pulmonary Injuny Induced by Accidental Exposure to High Level of Nitrogen Dioxide ($NO_2$) (고농도의 이산화질소($NO_2$)흡입으로 유발된 급성 폐손상 1례)

  • Chang Jin Hyuck;Kim Do Youn;Kim Young;Chang Yoon Soo;Kim Hyung Jung;Ahn Chul Min;Kim Sung Kyu;Kim Tae Hoon
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.1
    • /
    • pp.40-44
    • /
    • 2005
  • Nitrogen dioxide ($NO_2$), which produced during the process of silage, metal etching, explosives, rocket fuels, welding, and by-product of burning of fossil fuels, is one of major components of air pollutant. Accidental exposure of high level of $NO_2$ produces cough, dyspnea, pulmonary edema which may be delayed $4\~12$ hours and, in $2\~6$weeks, bronchiolitis obliterans. We experienced a case of acute pulmonary injuny induced by industrial exposure to high level of $NO_2$ during repair of $NO_2$ pipeline in a refinery. A 55-year-old man experienced nausea and severe dyspnea in 6 hours after $NO_2$ inhalation. Initial blood gas examination revealed severe hypoxemia accompanying increased alveolar-arterial O2 difference. Radiological examination showed diffuse ground glass opacities in both lung fields. Clinical symptoms and laboratory findings, including radiological study and pulmonary function test were improved with conservative treatment using inhaled oxygen and bronchodilator. and there was no evidence of bronchial fibrosis and bronchiolitis obliterance in chest high resolution computed tomography performed 6 weeks after exposure. Here, we report a case of $NO_2$ induced acute pulmonary injuny with a brief review of the relevant literature.

  • PDF

Relationship of Intraoperative Anatomical Landmarks, the Scapular Plane and the Perpendicular Plane with Glenoid for Central Guide Insertion during Shoulder Arthroplasty

  • Kim, Jung-Han;Min, Young-Kyoung
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.113-119
    • /
    • 2018
  • Background: This study was undertaken to evaluate the positional relationship between planes of the glenoid component (the scapular plane and the perpendicular plane to the glenoid) and its surrounding structures. Methods: Computed tomography (CT) images of both shoulders of 100 patients were evaluated using the 3-dimensional CT reconstruction program ($Aquarius^{(R)}$; TeraRecon). We determined the most lateral scapular bony structure of the scapular plane and measured the shortest distance between the anterolateral corner of the acromion and the scapular plane. The distance between the scapular plane and the midpoint of the line connecting the posterolateral corner of acromion and the anterior tip of the coracoid process (fulcrum axis) was also evaluated. The perpendicular plane was then adjusted to the glenoid and the same values were re-assessed. Results: The acromion was the most lateral scapular structure of scapular plane and perpendicular plane to the glenoid. The average distance from the anterolateral corner of the acromion to the scapular plane was $10.44{\pm}5.11mm$, and to the plane perpendicular to the glenoid was $9.55{\pm}5.13mm$. The midpoint of fulcrum axis was positioned towards the acromion and was measured at $3.90{\pm}3.21mm$ from the scapular plane and at $3.84{\pm}3.17mm$ from the perpendicular plane to the glenoid. Conclusions: Our data indicates that the relationship between the perpendicular plane to the glenoid plane and its surrounding structures is reliable and can be used as guidelines during glenoid component insertion (level of evidence: Level IV, case series, treatment study).

Analysis of Factors Related to Length of Stay Time in Patients with Back Pain at Emergency Department

  • Choi, Kwang Yong;So, Byung Hak;Kim, Hyung Min;Cha, Kyung Man;Jeong, Won Jung
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.173-178
    • /
    • 2017
  • Purpose: Most patients with acute low back pain visit emergency room (ER). They mostly need beds, and if their length of stay is longer, it can become difficult to accommodate new patients at the ER. We analyzed the treatment process of patients with back pain and tried to find method for shortening of the length of stay at the ER. Methods: We retrospectively analyzed the medical records of patients with back pain who visited at our ER for one year. Patients were divided into two groups according to their length of stay at ER and were compared the charateristcs of between two groups. Results: A total of 274 patients were included in the study. Eigthy-nine patients (32.5%) were in the group with less than 3 hours and 185 patients (67.5%) were in the other group. In the comparison of the two groups according to the medical departments, the number of patients who were in group with more than 3 hours were 25 (14.0%) in the emergency department, 94 (50.5%) in neurosurgery, 66 (35.5%) in orthopedic surgery. Length of stay was significantly increased in orthopedic surgery and neurosurgery (p=0.014). In addition, the length of stay was longer when computed tomography and magnetic resonance imaging examinations were performed (p=0.000). Regardless of the type of analgesic agent, the median time to the analgesic treatment was shorter in the group with less than 3 hours (p=0.034). Conclusions: In patients with back pain who visit the ER, the emergency medicine doctor will early control the pain and do not unnecessary image examination to reduce a length of stay at the ER.

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Correction of a Wide Alveolar Cleft with Reverse L osteotomy and Liou Alveolar Distractor (역 L 형 절골술과 Liou 신연기를 이용한 넓은 치조열의 교정)

  • Lee, Myung Chul;Lew, Dae Hyun;Park, Beyoung Yun;Kwon, Soon Man
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.445-449
    • /
    • 2009
  • Purpose: A successful surgical treatment for a wide alveolar cleft with bone graft is difficult to achieve due to several factors such as the limitation of gingivoperiosteal flap, the presence of large scar tissues, and the poor blood circulation. To overcome these problems, alveolar distraction osteogenesis using Liou alveolar distraction device was applied. We analyzed the consequences of this surgical treatment. Method: Between 2006 January and 2007 August, we have conducted analysis on the methods and consequences of Liou alveolar distraction osteogenesis for 6 patients. The age of patients was 12 years and 6 months in average. The follow up period was 19 months in average. The Reverse L osteotomy followed by the placement of the Liou alveolar distraction device was performed. After serial distraction, the distractor was removed after 5 months of the process of osteogenesis, and the result was analyzed using the computed tomography and the x-ray films of the alveolar bone and the teeth. Results: The alveolar cleft with 12.5 mm in average width was filled with 8.5 mm of newly formed bone tissue in average width after 5 months of osteogenesis. Among the 6 cases, 5 required the additional bone graft and 1 case only required the gingivoperioplasty. The newly formed bone tissues did not show any signs of bone resorption. However, a considerable degree of teeth displacement was shown. Conclusion: For the alveolar cleft too wide to be reconstructed by a general bone graft, it is strongly recommended to perform the reverse L osteotomy of the cleft side with Liou alveolar distraction device to initiate the alveolar osteogenesis. However, the migrated teeth showed some degree of relapse, thus, the orthodontic treatment is essential following the distraction osteogenesis treatment.

An effective patient training for deep inspiration breath hold technique of left-sided breast on computed tomography simulation procedure at King Chulalongkorn Memorial Hospital

  • Oonsiri, Puntiwa;Wisetrinthong, Metinee;Chitnok, Manatchanok;Saksornchai, Kitwadee;Suriyapee, Sivalee
    • Radiation Oncology Journal
    • /
    • v.37 no.3
    • /
    • pp.201-206
    • /
    • 2019
  • Purpose: To observe the effectiveness of the practical instruction sheet and the educational video for left-sided breast treatment in a patient receiving deep inspiration breath hold (DIBH) technique. Two parameters, simulation time and patient satisfaction, were assessed through the questionnaire. Methods: Two different approaches, which were the instruction sheet and educational video, were combinedly used to assist patients during DIBH procedures. The guideline was assigned at least 1 week before the simulation date. On the simulation day, patients would fill the questionnaire regarding their satisfaction with the DIBH instruction. The questionnaire was categorized into five levels: extremely satisfied to dissatisfied, sequentially. The patients were divided into four groups: not DIBH technique, DIBH without instruction materials, the DIBH with instruction sheet or educational video, and DIBH with both of instruction sheet and educational video. Results: Total number of 112 cases of left-sided breast cancer were analyzed. The simulation time during DIBH procedure significantly reduced when patients followed the instruction. There was no significant difference in simulation time on the DIBH procedures between patient compliance via instruction sheet or educational video or even following both of them. The excellent level was found at 4.6 ± 0.1 and 4.5 ± 0.1, for patients coaching via instruction sheet as well as on the educational video, respectively. Conclusion: Patient coaching before simulation could potentially reduce the lengthy time in the simulation process for DIBH technique. Practicing the DIBH technique before treatment is strongly advised.

A Case of Gunshot Injury to the Spinal Cord in a Cat:Clinical, Surgical, and Computed Tomographic Features (고양이 척수 총상 증례: 임상소견, 수술소견, 컴퓨터단층영상소견)

  • Ahn, Seoung-Yob;Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.32 no.2
    • /
    • pp.187-190
    • /
    • 2015
  • An 18-month-old female spayed domestic short-haired cat, weighing 4.1 kg, was presented as an emergency case after it suffered a gunshot injury. Physical examination of the cat revealed paraplegia, with loss of deep nociception. A bullet (diameter, 3 mm) lodged in the left epaxial muscle at the level of the first lumbar (L1) was observed on radiographic examination, and a hyperattenuating spot in the spinal canal was confirmed using computed tomography. Exploratory laminectomy was performed, and an incomplete fracture of the right caudal articular process of L1 and a necrotizing spinal cord lesion were found. The animal was euthanized and necropsy was performed, which revealed a crack on the left pedicle of L1. This case report presents the first detailed clinical description of a gunshot injury to the spinal cord in a cat.

Effect of Space Holder Content on Pore Size and Distribution in HA/β-TCP Composites Consolidated by SPS (SPS로 제조된 HA/β-TCP 복합재의 기공의 크기와 분포에 미치는 지지체 량의 영향)

  • Lee, Tack;Woo, Kee-Do;Kang, Dong-Soo;Lee, Hae-Cheol;Jang, Jun-Ho
    • Korean Journal of Materials Research
    • /
    • v.25 no.4
    • /
    • pp.165-170
    • /
    • 2015
  • Ceramics biomaterials are useful as implant materials in orthopedic surgery. In this study, porous HA(hydroxyapatite)/${\beta}$-TCP(tricalcium phosphate) composite biomaterials were successfully fabricated using HA/${\beta}$-TCP powders with 10-30 wt% $NH_4HCO_3$ as a space holder(SH) and $TiH_2$ as a foaming agent, and MgO powder as a binder. The HA/${\beta}$-TCP powders were consolidated by spark plasma sintering(SPS) process at $1000^{\circ}C$ under 20 MPa conditions. The effect of SH content on the pore size and distribution of the HA/${\beta}$-TCP composite was observed by scanning electron microscopy(SEM) and a microfocus X-ray computer tomography system(SMX-225CT). These microstructure observations revealed that the volume fraction of the pores increased with increasing SH content. The pore size of the HA/${\beta}$-TCP composites is about $400-500{\mu}m$. The relative density of the porous HA/${\beta}$-TCP composite increased with decreasing SH content. The porous HA/${\beta}$-TCP composite fabricated with 30%SH exhibited an elastic modulus similar to that of cortical bone; however, the compression strength of this composite is higher than that of cortical bone.

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.