• Title/Summary/Keyword: Process heat

Search Result 5,861, Processing Time 0.029 seconds

Performance Analysis of an Earth Coupled Heat Pump System Operated by an Engine(II) - Performance Analysis of a Vapour Compression type Compact Heat Pump - (엔진구동 지열 열펌프의 성능 분석(II) - 소형 증기압축식 열펌프의 성능 분석 -)

  • 김영복;송대빈;손재길
    • Journal of Biosystems Engineering
    • /
    • v.24 no.6
    • /
    • pp.501-512
    • /
    • 1999
  • In this study, the coefficient of performance of a vapour compression heat pump system was analyzed for the evaluation of the heat pump performance. A water-to-air heat pump was assembled and tested by changing the level of the compressor driving speed and the air mass flow rate during air heating process. The coefficient of performance for air heating was 2.6~3.8 and that for water cooling was 1.0~1.4. The coefficient of performance was not depending on the levels of the compressor driving speed or levels of the air mass flow rate, but on the temperature of the air and water. The coefficient of performance for air heating increased by about 0.2 with the water temperature increasing by 1$^{\circ}C$.

  • PDF

Determination of the Overall Heat Transfer Coefficient for Non-isothermal Finite Element Analysis (비 등온 유한요소해석을 위한 접면열전달계수의 결정)

  • 강연식;양동열
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.4
    • /
    • pp.72-77
    • /
    • 1997
  • In the temperature analysis of hot metal forming process, the heat transfer conditions between the work-piece and the tool have improtant influences upon the temperature distribution. The accuracy of thermal analysis depends on the proper description of boundary conditions including heat transfer. At the contact surface of two materials with different temperatures, this requires the knowledge of the overall heat transfer coefficient. In order to determine the overall heat transfer coefficient, a technique is developed. The technique involves temperature measurement by using thermocouples during hot upsetting operations and finite element computation. The overall heat transfer coefficient is determined using a non-linear optimization technique.

  • PDF

Numerical simulations of radiative and convective heat transfer in the cylinder of a diesel engine (디이젤엔진내의 복사열전달 효과에 관한 수치해석적 연구)

  • 임승욱;김동우;이준식
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.54-64
    • /
    • 1992
  • During combustion process in a diesel engine radiation heat transfer is the same order of magnitude as the convection heat transfer. An approximation of heat and momentum source distributions is applied at a level consistent with those used in modelling the soot distribution and the turbulence instead of modelling the fuel spray and the chemical kinetics. This paper illustrates a use of the third order spherical harmonics approximation to the radiative transfer equation and delta-Eddington approximation to the scattering phase function for droplets in the flow. Results are obtained numerically by a time marching finite difference scheme. This study aims to compare heat transfer with convection heat transfer and to investigate the importance of scattering by fuel droplets and of accounting for spatial variations in the extinction coefficient on the radiative heat flux distributions at the walls of a disc shaped diesel engine.

  • PDF

An Analysis for Predicting the Thermal Performance of Fin-Tube Heat Exchanger under Frosting Condition (착상시 핀-관 열교환기의 열적 성능 예측을 위한 해석)

  • Lee, T.H.;Lee, K.S.;Kim, W.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.299-306
    • /
    • 1996
  • This work presents an analytical model, so called modified LMTD method, to predict the thermal performance of finned-tube heat exchanger under frosting conditions. In this model, the total heat transfer coefficient and effective thermal conductivity of the frost layer were defined as a function of frost surface temperature. The surface temperature of the frost layer formed on the heat exchanger was calculated through the analysis of the heat and mass transfer process in the air and frost layer. To examine the validity of this analytical model, the computed results from the present model, such as heat transfer rate, frost mass and thickness of frost, were compared with the ones of the expermental work and LMED method.

  • PDF

Analyses of Fouling Mechanism using Visualization Techniques in a Lab-scale Plate-Type Heat Exchanging System (실험실용 판형 열교환 시스템에서 가시화를 이용한 파울링 기구 해석)

  • 성순경;서상호;노형운
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.349-354
    • /
    • 2004
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When the scale deposits in a heat exchanger surface, it is conventionally called fouling. The objective of the present study is to analyze the process of the fouling formation in a heat exchanger according to different types of water using visualization techniques. In order to experimentally investigate the formation of the fouling, this study built a lab-scaled heat exchanging system. Using the visualization techniques of Scanning Electron Microscopy (SEM) and X-Ray diffraction method, the three dimensional configurations of the fouling formation could be successfully obtained. Based on the experimental results, it was found that the configurations of the fouling formation were different when using tap water compared to river water.

Theoretical Analysis of a Recuperative Refrigeration Dehumidifier (열회수 냉각 제습기의 이론적 해석)

  • Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.48-54
    • /
    • 2014
  • A refrigeration dehumidifier with a recuperative heat exchanger is theoretically analyzed. The recuperative heat exchanger is located between the two air streams from and to the dehumidifying coil, and reduces the sensible heat load in dehumidification process. A simple model is developed to predict performance of the dehumidifier. The model predicts that the recuperative heat exchanger is effective especially in the low humidity condition, where the sensible heat load is relatively large. It is predicted that, by adopting a recuperative heat exchanger, a maximum 30~110% increase in COP is possible for indoor air at $27^{\circ}C$, and 40~60% relative humidity.

Numerical Study on Simultaneous Heat and Mass Transfer in a Falling Film of Water-Cooled Vertical Plate Absorber (수냉식 수직평판 흡수기의 액막 열 및 물질전달에 관한 수치적 연구)

  • Thanh-Tong Phan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.593-602
    • /
    • 2004
  • This paper is a study on the model of simultaneous heat and mass transfer process in the absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber. The model can predict temperature and concentration profiles as well as the effect of Reynolds number on them. Also. the variations of the absorption heat and mass fluxes. and the heat and mass transfer coefficients have been investigated. The numerical result shows that the interface temperature and concentration decrease as film Reynolds number does. The absorption heat and mass fluxes, and the heat and mass transfer coefficients get their maximum values adjacent to the inlet solution. Analyses on a constant wall temperature condition have been also carried out to exam the reliability of the present numerical method by comparing to previous investigations.

Melting Heat Transfer Characteristics of Plural Phase Change Microcapsules Slurry Having Different Diameters

  • Kim, Myoung-Jun;Kim, Myoung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1225-1238
    • /
    • 2004
  • The present study has been performed for obtaining the melting heat transfer enhancement characteristics of water mixture slurries of plural microcapsules having different diameters encapsulated with solid-liquid phase change material(PCM) flowing in a pipe heated under a constant wall heat flux condition. In the turbulent flow region, the friction factor of the present PCM slurry was to be lower than that of only water flow due to the drag reducing effect of the PCM slurry. The heat transfer coefficient of the PCM slurry flow in the pipe was increased by both effects of latent heat involved in phase change process and microconvection around plural microcapsules with different diameters. The experimental results revealed that the average heat transfer coefficient of the PCM slurry flow was about 2~2.8 times greater than that of a single phase of water.

Drying Performance Simulation for the Basic Design of a Heat Pump Dryer (열펌프 건조기의 기본 설계를 위한 건조 성능 해석)

  • Lee, Kong-Roon;Kim, Ook-Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.860-867
    • /
    • 2007
  • Heat pump drying has a great potential for energy saving due to its high energy efficiency in comparison with conventional air drying. In the present study, the performance simulation for the basic design of a heat pump dryer has been carried out. The simulation includes one-stage heat pump cycle, simple drying process using the drying efficiency. As an example, the heat pump cycle with Refrigerant 134a has been investigated. For the operating conditions such as the average temperature of the condenser, the heat rate released in the condenser, the flow rate of drying air, and drying efficiency, the simulation has been carried out to figure out the performance of the dryer. The parameters considered in the design of the dryer are COP, MER, SMER, the rate of dehumidification, the temperature and humidity of drying air and those parameters are compared for different conditions after carrying out the simulation.

Performance Analysis of a Panel Type Latent Heat Storage Equipment for Solar Thermal Storage (태양열저장(太陽熱貯藏)을 위한 평판형잠열축열장치(平板形潛熱蓄熱裝置)의 성능분석(性能分析))

  • Kim, Y.B.;Ju, E.S.;Yun, Y.D.;La, W.J.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.3
    • /
    • pp.290-297
    • /
    • 1991
  • For the efficient utilization of the solar thermal energy to overcome the time gap between to supply and demand, an efficient heat storage technique, especially high density-latent-heat storage system, is necessary. In this study, the performance of a panel type latent heat storage equipment during heat discharging process was analyzed theoretically and experimentally. In order to find out the performance of the system, computer simulation programs were developed by finite difference method. The governing equations were constructed by two dimensional heat conduction model with moving boundary. The results of the experimental and the theoretical analysis were reasonably well agreed. The efficiencies of the double pipe type and the panel type latent heat storage equipment were compared.

  • PDF