• Title/Summary/Keyword: Probe location

Search Result 123, Processing Time 0.027 seconds

Lateral Force Calibration of Colloidal Probe in Liquid Environment Using Reference Cantilever (기준 외팔보를 이용한 액체 환경에서 Colloidal Probe의 수평방향 힘 교정)

  • Je, Youngwan;Chung, Koo-Hyun
    • Tribology and Lubricants
    • /
    • v.29 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • There is an indispensable need for force calibration for quantitative nanoscale force measurement using atomic force microscopy. Calibrating the normal force is relatively straightforward, whereas doing so for the lateral force is often complicated because of the difficulty in determining the optical lever sensitivity. In particular, the lateral force calibration of a colloidal probe in a liquid environment often has a larger uncertainty as a result of the effects of the epoxy, the location of the colloidal particle on the cantilever, and a decrease in the quality factor. In this work, the lateral force of a colloidal probe using a reference cantilever with a known spring constant was calibrated in a liquid environment. By obtaining the spring constant and the lateral sensitivity at the equator of a spherical colloidal particle, the damage to the bottom surface of the colloidal particle could be eliminated. Further, it was shown that the effect of the contact stiffness on the determination of the lateral spring constant of the cantilever could be minimized. It was concluded that this method can be effectively used for the lateral force calibration of a colloidal probe in a liquid environment.

Touchpad for Force and Location Sensing

  • Kim, Dong-Ki;Kim, Jong-Ho;Kwon, Hyun-Joon;Kwon, Young-Ha
    • ETRI Journal
    • /
    • v.32 no.5
    • /
    • pp.722-728
    • /
    • 2010
  • This paper presents the design and fabrication model of a touchpad based on a contact-resistance-type force sensor. The touchpad works as a touch input device, which can sense contact location and contact force simultaneously. The touchpad is 40 mm wide and 40 mm long. The touchpad is fabricated by using a simple screen printing technique. The contact location is evaluated by the calibration setup, which has a load cell and three-axis stages. The location error is approximately 4 mm with respect to x-axis and y-axis directions. The force response of the fabricated touchpad is obtained at three points by loading and unloading of the probe. The touchpad can detect loads from 0 N to 2 N. The touchpad shows a hysteresis error rate of about 11% and uniformity error rate of about 3%.

Propagation Characteristic of Ultrasonic on Slit Defect in Butt Joint (맞대기 용접부내의 인공 결함에서 초음파의 전파특성)

  • 남영현
    • Journal of Welding and Joining
    • /
    • v.14 no.6
    • /
    • pp.37-47
    • /
    • 1996
  • An ultrasonic testing uses the directivity of the ultrasonic wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is related to determination of testing sensitivity, scanning pitch and defect location. This paper investigated the directivity of ultrasonic wave, which scattered from slit defect located in heat-affected zone (HAZ) in butt joint using visualization method. The directivity of shear waves scattered from slit defect were different according to probe direction (far defect, near defect) and probe position (forward movement, maximum echo position, backward movement). The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. In the case of 2 MHz angle probe, the directivity of reflection wave was appeared sharp form because of the relation wave length and defect size.

  • PDF

Influence to the Doppler Images by the Defects of SAE in the Probe of Medical Ultrasonic Scanners (초음파 프로브에서 인접 단위 소자군(SAE) 결함이 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • A ultrasonic probe is very important in medical ultrasonic image, but the frequency of probe defects are often. Therefore practical tools for probe based ultrasonic QA should be developed. Advanced research on the effects of the probe defects on the quality of ultrasonic images is required. This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. Especially the defects in a set of adjacent elements(SAE) electrically disconnected influence Doppler images were tested. The results show Doppler brightness and velocity became rapidly reduced as the defected elements is located centrally, as the defected elements is activated. The more the defected elements increased, the more Doppler brightness and velocity increased. As a set of the element disconnected moved, it appeared Doppler velocity starting to decrease and then was followed by brightness. The strength is not consistent with the velocity in the number and location of the defected elements. The defects in the probe elements influence Doppler velocity when the defected elements got out of the elements activated at Doppler mode.

Molecular probe for identification of cysts of resting cyst of PSP-producer Alexandrium tamarense (Dinophyceae) (분자생물학적 방법을 이용하여 마비성 패류 독소를 생산하는 알렉산드륨 타마렌스 시스트 탐색)

  • Cho, Eun-Seob
    • Journal of Life Science
    • /
    • v.13 no.2
    • /
    • pp.163-167
    • /
    • 2003
  • Identification of species within the toxin-producing genus Alexandrium is vital for biotoxin monitoring and mitigation decisions regarding shellfish industry. In particular, the discrimination of resting cysts of only A. tamarense from that of Alexandrium spp. is considerable important to fundamentally monitor and predict this species before vegetative cells occur in the nature. Fluorescent cTAM-F1 DNA probe was responsible to not only binding the activity of the vegetative cells in A. tamarense, but also to the resting cysts, which was treated with methanol after fixation and stained by primuline on the surface The location of fluorescence in cultured vegetative cells and resting cysts was almost at tile bottom of the nucleus. The optimal incubation temperature and time using in situ hybridization were 50-$54^{\circ}C$ and 40-60 min, respectively, to penetrate the DNA probe into cell.

Optimization of Thermal Deformation in Probe Card (프로브 카드의 열변형 최적화)

  • Chang, Yong-Hoon;Yin, Jeong-Je;Suh, Yong-S.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4121-4128
    • /
    • 2010
  • A probe card is used in testing semiconductor wafers. It must maintain a precise location tolerance for a fine pitch due to highly densified chips. However, high heat transferred from its lower chuck causes thermal deformations of the probe card. Vertical deformation due to the heat will bring contact problems to the pins in the probe card, while horizontal deformation will cause positional inaccuracies. Therefore, probe cards must be designed with proper materials and structures so that the thermal deformations are within allowable tolerances. In this paper, heat transfer analyses under realistic loading conditions are simulated using ANSYS$^{TM}$ finite element analysis program. Thermal deformations are calculated based on steady-state temperature gradients, and an optimal structure of the probe card is proposed by adjusting a set of relevant design parameters so that the deformations are minimized.

Needle Type of Hybrid Temperature Probe for Both Diagnosis and Treatment of Musculoskeletal Pain Syndrome (근골격계 통증질환의 진단과 치료를 위한 주사바늘형 복합온도 프로브의 개발)

  • Nam, Sung-Ki;Kim, Hyung-Il;Byun, Chang-Ho;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.4
    • /
    • pp.359-364
    • /
    • 2014
  • This paper describes the development of needle type probe that measures temperature and injects medicine for both diagnosis and treatment of musculoskeletal pain syndrome (MPS). The size of trigger points is from several micrometers to millimeter. Therefore, it is required to develop a medical device that is capable of not only finding the trigger points by temperature measurement, but also injecting medicine at the exact location for treatment. To challenge these difficulties, thermocouple was fabricated on the surface of a needle using metal deposition process. Special type of stainless-constantan thermocouple was achieved from the stainless body of a needle itself and deposited constantan metal film. In particular, parylene coating enables to limit the temperature sensitive area to the end of the needle tip. Fabricated needle type probe produces $3.25mV/^{\circ}C$ of thermoelectric sensitivity and compared its performance with commercial T-type thermocouple in animal muscle sample.

Knock Characteristics and Measurement of Knock Location in a 4-Valve SI Engine (4-Valve SI 엔진의 Knock 특성 및 Knock 발생부위 측정)

  • 이경환;이시훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.153-161
    • /
    • 1998
  • The knock in a spark ignition engine has been investigated to avoid the damage to the engine and unpleasant feeling caused by the pressure waves propagating across the combustion chamber. Knock intensity and knock onset angle were used as physical parameters to quantify the knock characteristics. The knock intensity is defined as a peak to peak value of the bank pass filtered combustion pressure signal and the knock onset angle is determined as the crank angle at which this signal exceeded the threshold level on each cycle. The cyclic variation of knock in four valve single cylinder engine was investigated with these two parameters. The location of autoignition was also examined by ion probes in the cylinder head gasket and squish region in the combustion chamber. For this measurement, a single cylinder engine was modified to accept the pressure transducer, 18 ion probes in the squish region and 8 ion probes in the specially designed PCB (Printed \ulcornerCircuit Board) cylinder head gasket.

  • PDF

Bottleneck link bandwidth Measurement Algorithm for improving end-to-end transit delay in Grid network (그리드 네트워크에서 종단간 전송 지연 향상을 위한 bottleneck 링크 대역폭 측정 알고리즘)

  • Choi, Won-Seok;Ahn, Seong-Jin;Chung, Jin-Wook
    • The KIPS Transactions:PartC
    • /
    • v.10C no.7
    • /
    • pp.923-928
    • /
    • 2003
  • This paper proposes a bottleneck link bandwidth measurement algorithm for reducing packet transmission delay within the grid network. There are two methods for measuring bottleneck link bandwidth:Packet Pair algorithm and Paced Probes algorithm. They measure bottleneck link bandwidth using the difference in arrival times of two paced probe packets of the same size traveling from the same source to destination. In addition, they reduce the influences of cross traffic by pacer packet. But there are some problems on these algorithms:it's not possible to know where bottleneck link occurred because they only focus on measuring the smallest link bandwidth along the path without considering bandwidth of every link on the path. So hop-by-hop based bottleneck link bandwidth measurement algorithm can be used for reducing packet transmission delay on grid network. Timestamp option was used on the paced probe packet for the link level measurement of bottleneck bandwidth. And the reducing of packet transmission delay was simulated by the solving a bottleneck link. The algorithm suggested in this paper can contribute to data transmission ensuring FTP and realtime QoS by detecting bandwidth and the location where bottleneck link occurred.