• 제목/요약/키워드: ProFile

검색결과 131건 처리시간 0.025초

Influence of pre-existing surface defects on NiTi rotary instrument failure: A SEM study

  • Shin, Yu-Mi;Kim, Wu-Sung;Kum, Kee-Yeon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.594-594
    • /
    • 2003
  • I. Objectives The purpose of this study is to determine if propagation of pre-existing manufacturing defects results in brittle fracture of NiTi rotary files by examining the fracture surface of the instrument by SEM, and to compare the fracture time of NiTi rotary files with different flute designs under cyclic loading. II. Materials and Methods This study examined three groups of rotary NiTi instruments (K3, ProFile, Hero). Of each group, 04 taper, size 30 and 06 taper, size 25 were selected.:120 in total. Surface defects were created by simulating the machining process of NiTi rotaries.(omitted)

  • PDF

Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha

  • Lee, Young-Mi;Park, Jeong-Won;Kim, Sung-Kyo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.557-557
    • /
    • 2003
  • I. Objectives The purpose of this study was to evaluate the ratio of gutta-percha area in the canal after canal obturation with Continuous Wave of Condensation Technique with varying depths of plugger penetration. II. Materials and Methods Forty extracted human teeth with single canal were divided into four group of ten teeth each. Root canals were prepared up to size 40 of 0.06 taper with $ProFile^{\circledR}$. After drying, canals of three groups were filled with Continuous Wave of Condensation Technique with System $B^{TM}$ and different plugger penetration depths of 3, 5, and 7mm from the apex.(omitted)

  • PDF

Plugger 삽입깊이가 근관내 gutta-percha 점유면적에 미치는 영향 (Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha)

  • 이영미;소호영;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.66-71
    • /
    • 2006
  • Continuous Wave 가압법으로 근관충전시 plugger 삽입 깊이에 따른 근관내 gutta-percha 비율을 평가하고자 40개의 발거치아 근관을 0.06 경사도 40번 크기의 $ProFile^{(R)}$로 근관을 형성하고 세 군에서는 plugger 삽입깊이를 근단 3, 5 또는 7 mm로 하여 System $B^{TM}$를 이용하여 Continuous Wave 가압법으로 충전하였고, 한 군에서는 대조군으로서 측방가압법으로 근관을 충전하였다. 충전된 근관은 치근단 1, 2 및 3mm 수준에서 횡절단하여 근관내 gutta-percha 면적비를 계산하고 일원변량분석법을 이용하여 통계분석 하였다. 모든 절단수준에서, Continuous Wave 가압법으로 충전한 군 사이에서는 plugger의 삽입깊이가 깊을수록 높은 gut-ta-percha 면적비를 나타내었고, 측방가압법으로 충전한 군이 plugger의 삽입깊이를 7 mm로 충전한 군보다 높은 gut-ta-percha 면적비를 나타내었다 (p<0.05).

EndoVac®과 EndoActivator®를 이용한 근관세척법의 Enterococcus faecalis 제거 효율 평가 (EVALUATION OF ENTEROCOCCUS FAECALIS REMOVAL EFFICACY OF THE ENDOVAC® AND ENDOACTIVATOR® INTRACANAL IRRIGATION METHODS)

  • 송승곤;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.390-396
    • /
    • 2009
  • 이 실험의 목적은 $EndoVac^{(R)}$$EndoActivator^{(R)}$를 이용한 근관세척시 근관 내 접종된 Enterococcus faecalis의 제거 효율을 기존의 irrigation needle을 이용한 방법과 비교 평가하고자 함이다. 발거된 70개의 단근치를 사용하였으며 .04 taper ProFile #40까지 근관형성 후 치아를 멸균하고 근관에 E. faecalis를 접종하고 배양하였다. 치아는 근관세척 방법에 따라 20개씩 3개의 실험군과 2개의 대조군으로 나누었다. 2.5% 치아염소산나트륨을 사용하여 근관세척 시행 후 일차 표본을 채취하였고, 다시 근관 내에 배양액을 채우고 24시간 동안 배양 후 이차 표본을 채취하였다. 표본은 colony forming units (CFU) 값을 얻기 위해 BHI agar plate에 배양하였다. 일차 표본 결과에서는 모든 실험치아 중 기존의 근관세척 방법을 이용한 하나의 근관에서 양성 배양을 보였다. 이차 표본 결과에서는 $EndoVac^{(R)}$ 실험군에서 가장 적은 양성 배양을 보였으며, 기존의 근관세척 방법과 비교시 통계적으로 유의한 차이를 보였다. 실험 결과에 따르면 $EndoVac^{(R)}$은 근관 내 접종된 E. faecalis의 제거에 있어 기존의 근관세척 방법보다 더 좋은 효율을 보였다.

수산화칼슘 제제의 제거 방법이 치근단 누출에 미치는 영향에 대한 전기화학적 연구 (Effect of two different calcium hydroxide paste removal techniques on apical leakage: an electrochemical study)

  • 박찬제;전경아;권호범
    • Restorative Dentistry and Endodontics
    • /
    • 제31권3호
    • /
    • pp.186-191
    • /
    • 2006
  • 본 연구의 목적은 근관내 약제로 사용되는 수산화칼슘의 제거방법이 근관충전 후 치근단 미세누출에 미치는 영향을 알아보기 위함이다. 70개의 발거된 단근치를 엔진구동형 ProFile로 근관형성한 후 수용성 수산화칼슘 제제를 1주일간 적용하고 두 군으로 나누어 각기 다른 방법으로 제거하였다. A군은 NaOCl로 근관세정만을 시행하였으며, B군은 근관형성 시 사용된 file보다 한 단계 큰 크기의 ProFile을사용하여 근관을 재형성한 후 NaOCl로 세척하였다. 근관충전 후 전기화학적 방법으로 24일 동안 치근단 누출을 측정, 비교하였다. 본 연구의 결과 수산화 칼슘 제거를 위한 두가지 방법은 근관충전후 치근단 미세누출에 있어서 차이가 없음을 알 수 있었다.

수종의 수산화칼슘 근관 첩약제와 레진계 근관 실러의 사용 후 통증 발생 빈도에 관한 연구 (Comparison of the Frequency of Pain Occurrence by Using Different Calcium Hydroxide Pastes and Root Canal Sealers)

  • 곽상원;김현철
    • 대한치과의사협회지
    • /
    • 제56권5호
    • /
    • pp.254-262
    • /
    • 2018
  • Objectives: This study aimed to compare the postoperative pain and clinical performance after applying three different intracanal medicaments and root canal sealers. Materials and Methods: Sixty-five patients requiring root canal treatment due to symptomatic apical periodontitis were included in this study. After a glide path preparation by using PathFile, each canal was shaped with ProTaper Next file system. After the canal cleaning and shaping procedure, the canal was dried and each intracanal medicaments were adjusted (Calcipex II, TRC-paste, Metapaste). At the next visit, the patients were requested to answer the absence of the pain after the procedure. Once the patients showed no symptom, the canal was obturated with each corresponded root canal sealers (AH plus, Radic-sealer, ADseal). The patients were recalled after 1 week, 1, 3, and 6 months to check the postoperative pain or unexpected clinical signs. One-way ANOVA and Duncan's post hoc comparison, and Chi-square test were used for statistical analysis to evaluate any differences among tested materials. Results: The average number of visits for intracanal medication was 2.69, 2.65, and 2.61 for Calcipex II, TRC-paste, and Metapaste. There were no statistically differences in post-obturation pain among three groups obturated with different root canal sealers (P > 0.05). Conclusions: Under the limitations of this study, three tested intracanal medicaments and epoxy resin root canal sealers showed clinically acceptable similar results.

  • PDF

온라인 게임 소프트웨어 복제도 산출기법에 관한 연구 (The Study of Similarity Measure on O-Line Game Software)

  • 김진용;김진욱
    • 한국게임학회 논문지
    • /
    • 제4권1호
    • /
    • pp.50-57
    • /
    • 2004
  • 게임산업은 급속한 성장기를 맞이하고 있으며 대중적, 상업적으로 흥행 에 성공한 게임에 대한 저작권, 표절, 복제에 대한 논란이 급증하고 있다. 컴퓨터 게임은 유행에 민감하며 이러한 소재를 중심으로 게임을 개발을 완성하기 위해서는 짧은 시간, 저렴한 비용, 기술력의 부족 등으로 인하여 게임에 대한 저작권, 복제, 표절에 대한 분쟁이 점차 증가되고 있다. 본 논문에서는 원시코드들을 비교 분석할 수 있는 도구들의 특성을 분석하여 게임 원시코드 분석에 적합한 Windiff를 이용하여, 게임 원시코드를 분석하여 원본프로그램과 복제프로그램간의 복제도를 산출하는 방법에 대하여 연구하였다. 복제도를 산출하는 방법은 게임 특징따라 기능별로 모듈을 나누고, 각 모듈에서 파일구조, 원시프로그램, 자료구조 형태로 파일을 분리한 후 복사도를 계산하였다. 계산된 복사도에서 게임특성상 각 기능의 중요도에 따라 가중치를 두어 전체 게임프로그램의 정량적인 복제도를 산출하였다.

  • PDF

수종의 역충전 재료의 치근단 밀폐력 비교 (COMPARISON OF THE SEALING ABILITY OF VARIOUS RETROGRADE FILLING MAIERIALS)

  • 황윤찬;강인철;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.379-386
    • /
    • 2001
  • This study was performed to evaluate the sealing ability of various retrograde filling materials by using bacterial penetration and dye penetration test. One hundred and forty extracted human teeth with single, straight canals and mature apiece were collected and used for this study. All canals were instrumented using an engine driven Ni-Ti file (ProFile). After removing 3mm from the apex of tooth, a standardized 3mm root end cavity was prepared using an ultrasonic instrument. The 70 teeth were randomly divided into 7 groups : 6 groups for retrograde filling using Super-EBA, ZOE, Chelon-Silver, IRM, ZPC and amalgam. The 7th group was used as a negative control. Nail varnish was applied to all external root surfaces to the level of the reseated root ends to prevent lateral microleakages. The specimens were then sterilized in an ethylene oxide sterilizer for 24 hours. 2 mm of the reseated root was immersed in a culture chamber containing a Tripticase Soy Broth with a phenol red indicator. The coronal access of each specimen was inoculated every 72 hours with suspension of Proteus vulgaris. The culture media were observed every 24hours for color change indicating bacterial contamination. The specimens were observed for 4weeks. The remaining 70 teeth were submitted to a dye penetration test. The canals of all teeth were first sealed with AH26 and obturated using an Obtura II system. Root resection, root end preparation and retrograde filling was performed as above. All specimens were suspended in 2% methylene blue dye for 72 hours before being ion gitudinally split. The degree of dye penetration was then measured using a stereomicroscope at 10 magnification and evaluated. The results were as floows : 1. In the bacterial penetration, the degree of leakage was the lowest in the Super-EBA, followed by, in ascending order, ZOE, Chelon-Silver IRM and ZPC. The amalgam showed highest bacterial leakage of all(p<0.01). 2. In the dye penetration, the degree of microleakage was the lowest in the Chelon-Silver and Super-EBA, followed by, in ascending order, IRM, ZPC. The ZOE and amalgam showed the highest microleakage of all (p<0.05). These results suggested that the eugenol based cement, Super-EBA, have excellent sealing ability as a retrograde filling material.

  • PDF

전동식 니켈 티타늄 파일의 표면 결함 및 단면 형태가 반복응력 하에서 피로 파절에 미치는 영향 (EFFECT OF SURFACE DEFECTS AND CROSS-SECTIONAL CONFIGURATION ON THE FATIGUE FRACTURE OF NITI ROTARY FILES UNDER CYCLIC LOADING)

  • 신유미;김의성;김광만;금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제29권3호
    • /
    • pp.267-272
    • /
    • 2004
  • The purpose of this in vitro study was to evaluate the effect of surface defects and cross-sectional configuration of NiTi rotary files on the fatigue life under cyclic loading. Three NiTi rotary files ($K3^{TM},{\;}ProFile^{\circledR},{\;}and{\;}HERO{\;}642^{\circledR}$) with #30/.04 taper were evaluated. Each rotary file was divided into 2 subgroups : control (no surface defects) and experimental group (artificial surface defects), A total of six groups of each 10 were tested. The NiTi rotary files were rotated at 300rpm using the apparatus which simulated curved canal (40 degree of curvature) until they fracture. The number of cycles to fracture was calculated and the fractured surfaces were observed with a scanning electron microscope. The data were analyzed statistically. The results showed that experimental groups with surface defects had lower number of cycles to fracture than control group but there was only a statistical significance between control and experimental group in the $K3^{TM}$ (p<0.05), There was no strong correlation between the cross-sectional configuration area and fracture resistance under experimental conditions. Several of fractured files demonstrated characteristic patterns of brittle fracture consistent with the propagation of pre-existing cracks. This data indicate that surface defects of NiTi rotary files may significantly decrease fatigue life and it may be one possible factor for early fracture of NiTi rotary files in clinical practice.

A micro-computed tomographic study of remaining filling materials of two bioceramic sealers and epoxy resin sealer after retreatment

  • Kim, KyungJae;Kim, Da Vin;Kim, Sin-Young;Yang, SungEun
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.18.1-18.9
    • /
    • 2019
  • Objective: This study evaluated the presence of residual root canal filling material after retreatment using micro-computed tomography (micro-CT). Materials and Methods: Extracted human teeth (single- and double-rooted, n = 21/each; C-shaped, n = 15) were prepared with ProFile and randomly assigned to three subgroups for obturation with gutta-percha and three different sealers (EndoSeal MTA, EndoSequence BC sealer, and AH Plus). After 10 days, the filling material was removed and the root canals were instrumented one size up from the previous master apical file size. The teeth were scanned using micro-CT before and after retreatment. The percentage of remaining filling material after retreatment was calculated at the coronal, middle, and apical thirds. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni post hoc correction. Results: The tested sealers showed no significant differences in the percentage of remaining filling material in single- and double-rooted teeth, although EndoSeal MTA showed the highest value in C-shaped roots (p < 0.05). The percentage of remaining filling material of AH Plus and EndoSeal MTA was significantly higher in C-shaped roots than in single- or double-roots (p < 0.05), while that of BC sealer was similar across all root types. EndoSeal MTA showed the highest values at the apical thirds of single- and double-roots (p < 0.05); otherwise, no significant differences were observed among the coronal, middle, and apical thirds. Conclusions: Within the limitations of this study, a large amount of EndoSeal MTA remained after retreatment, especially in C-shaped root canals.