• Title/Summary/Keyword: ProFile

Search Result 131, Processing Time 0.031 seconds

THE EFFECT OF DIFFERENT FLUTE DESIGN AND TORQUE-CONTROLLED MOTOR ON THE SHAPING ABILITY OF SIMULATED RESIN ROOT CANALS (엔진의 토크 조절 능력과 니켈-티타늄 파일의 삭제 성향이 근관 성형에 미치는 영향)

  • Roh, Hyoung-Mee;Huh, Bock;Kim, Hyeon-Cheol;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.486-492
    • /
    • 2005
  • The purpose of this study was to compare the shaping ability of the two different Ni-Ti file systems and the two different engine systems in simulated canals. A total of four groups of each 10 were tested. Each group was instrumented with HeroShaper and Endo-Mate2 (Croup HE), HeroShaper and Tecnika (Croup HT), ProFile and Endo-Mate2 (Group PE), and ProFile and Tecnika (Croup PT). Canal preparation time was recorded. The images of pre- and post- instrumented root canals were scanned and superimposed. The amounts of increased width and centering ratio were measured and calculated at apical 1, 3 and 5mm levels. These data were statistically analyzed with one-way ANOVA and Duncan's multiple range test The results of this study were as fellows ; 1. Canal preparation time of HT group was the shortest (p<0.05). 2. The amount of increased canal width in HE group was significantly larger than PT group at apical 1mm level (p<0.05) At apical 3mm level, PT group was significantly smaller than other groups (p<0.05). At apical 5mm level, PE group was significantly larger than PT group (p<0.05). 3. The amount of centering ratio in HE group was significantly larger than other groups (p<0.05). At apical 5mm level, HT group was significantly larger than PE group and PT group (p<0.05). Under the condition of this study, torque-controlled endodontic motor is safer than no torque controlled motor, especially when the active file is used.

Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro study

  • Feky, Hadeer Mostafa El;Ezzat, Khalid Mohammed;Bedier, Marwa Mahmoud Ali
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.44.1-44.11
    • /
    • 2019
  • Objectives: To compare the flexural cyclic fatigue resistance and the length of the fractured segments (FLs) of recently introduced M-Pro rotary files with that of RaCe rotary files in curved canals and to evaluate the fracture surface by scanning electron microscopy (SEM). Materials and Methods: Thirty-six endodontic files with the same tip size and taper (size 25, 0.06 taper) were used. The samples were classified into 2 groups (n = 18): the M-Pro group (M-Pro IMD) and the RaCe group (FKG). A custom-made simulated canal model was fabricated to evaluate the total number of cycles to failure and the FL. SEM was used to examine the fracture surfaces of the fragmented segments. The data were statistically analyzed and comparisons between the 2 groups for normally distributed numerical variables were carried out using the independent Student's t-test. A p value less than 0.05 was considered to indicate statistical significance. Results: The M-Pro group showed significantly higher resistance to flexural cyclic fatigue than the RaCe group (p < 0.05), but there was no significant difference in the FLs between the 2 groups (p ≥ 0.05). Conclusions: Thermal treatment of nickel-titanium instruments can improve the flexural cyclic fatigue resistance of rotary endodontic files, and the M-Pro rotary system seems to be a promising rotary endodontic file.

Healing of STEP AP214 Automotive CAD Data (STEP AP214 자동차 설계 데이터 정리 시스템)

  • 양정삼;한순흥
    • Korean Journal of Computational Design and Engineering
    • /
    • v.7 no.3
    • /
    • pp.170-176
    • /
    • 2002
  • To exchange CAD data between heterogeneous CAD systems, we generally use a neutral format especially STEP, which is the international standard (ISO-10303) for product model data exchange. AP214 (Application Protocol) for the automotive industry not only takes into account geometry and organizational data, but also provides a classification mechanism for product modeling. When reading a STEP file during a design process that is exported from other CAD systems, it is a burden to a designer to go through the tedious process of removing duplicate or non-manifold entities, adjusting parts, and rearranging text. We analyze the structure of AP214 and develop a healing tool to solve the following problem. Without the assembly information in the Master workspace of CATIA, or to read a STEP file from Pro/Engineer, a designer should do a repetitive process of disintegrating an assembly into parts one by one. We have developed a post-processing tool for STEP AP214 that separates out a part from an assembly model and adjusts superfluous or useless entities using the ACIS kernel.

Influence of plugger penetration depth on the apical extrusion of root canal sealer in Continuous Wave of Condensation Technique (플러거 삽입깊이가 근관실러의 치근단 정출에 미치는 영향)

  • So Ho-Young;Lee Young-Mi;Kim Kwang-Keun;Kim Ki-Ok;Kim Young-Kyung;Kim Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.439-445
    • /
    • 2004
  • The purpose of this study was to evaluate the influence of plugger penetration depth on the apical extrusion of root canal sealer during root canal obturation with Continuous Wave of Condensation Technique. Root canals of forty extracted human teeth were divided into four groups and were prepared up to size 40 of 0.06 taper with ProFile. After drying. canals of three groups were filled with Continuous Wave of Condensation Technique with System $B^{TM}$ and different plugger penetration depths of 3. 5, and 7 mm from the apex. Canals of one group were filled with cold lateral compaction technique as a control. Canals were filled with non-standardized master gutta-percha cones and 0.02 mL of Sealapex. Apical extruded sealer was collected in a container and weighed. Data was analyzed with one-way ANOVA and Duncan's Multiple Range Test. 3 and 5 mm penetration depth groups in Continuous Wave of Condensation Technique showed significantly more extrusion of root canal sealer than 7 mm penetration depth group (p < 0.05). However, there was no significant difference between 7 mm depth group in Continuous Wave of Condensation Technique and cold lateral compaction group (p < 0.05). The result of this study demonstrates that deeper plugger penetration depth causes more extrusion of root canal sealer in root canal obturation by Continuous Wave of Condensation Technique. Therefore, special caution is needed when plugger penetration is deeper in the canal in Continuous Wave of Condensation Technique to minimize the amount of sealer extrusion beyond apex.

Efficacy of retreatment NiTi files for root canals filled with calcium silicate-based sealer (칼슘실리케이트 계열 실러로 충전한 근관에서 재치료용 NiTi 파일의 효율성)

  • Jae-Yun, Hyun;Kyung-Mo, Cho;Se-Hee, Park;Yoon, Lee;Yoon-Joo, Lee;Jin-Woo, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.213-221
    • /
    • 2022
  • Purpose: The efficacy of the amount of sealer in the root canal and two retreatment NiTi file systems in removing filling materials. Materials and Methods: Extracted premolars with a single root canal were selected for this study. After access opening and root canal preparation up to size #40/.06, the specimens were randomly divided into four groups. Gutta percha (GP) tapers of .06 or .04 were used for each group and filled using a single-cone filling technique with CeraSeal, a calcium silicate-based sealer. Each group was retreated either using the ProTaper Universal Retreatment System (PTUR) or the Hyflex Remover (HR). The time taken to remove the filling material, the amounts of apically extruded debris, and canal cleanliness were measured and compared. Results: The amount of sealer did not affect the efficiency when removing the filling materials. However, the filling material was removed faster in the HR group than in the PTUR group. Two types of NiTi files showed similar retreatment effects in the amounts of apically extruded debris and in the degree of canal cleanliness. Conclusion: The amount of sealer in canal filling had no significant effect on retreatability. Retreatment with HR removed filling materials is faster than PTUR. There was no difference in other removal efficiencies according to the type of retreatment NiTi file.

A Study on the Ship Cargo Hold Structure Data Model Based on STEP (STEP을 근거로 한 선체화물창부 구조 데이터 모델에 관한 연구)

  • 박광필;이규열;조두연
    • Korean Journal of Computational Design and Engineering
    • /
    • v.4 no.4
    • /
    • pp.381-390
    • /
    • 1999
  • In this study, a pseudo ship structure data model for the :.hip cargo hold structure based on STEP is proposed. The proposed data model is based on Application Reference Model of AP218 Ship Structure which is the model that specifies conceptual structures and constraints used to describe the information requirements of an application. And the proposeddata model refers the Ship Common Model framework for the model architecture which is the basis for ongoing ship AP development within the ISO ship-building group and the ship product definition information model of CSDP research project for analyzing the relationship between ship structure model entities. The proposed data model includes Space, Compartment. Ship Structural System, Structural Part and Structural Feature of cargo hold. To generate this data model schema in EXPRESS format, ‘GX-Converter’was used which enables user to edit a model in EXPRESS format and convert schema file in EXPRESS format. Using this model schema, STEP physical file containing design data for ship cargo hold data structure was generated through SDAI programming. The another STEP physical file was also generated containing geometry data of ship cargo hold which was extracted and calculated by SDAI and external surface/surface intersection program. The geometry information of ship cargo hold can be then transferred to commercial CAD system, for example, Pro/Engineer. Examples of the modification of the design information are also Presented.

  • PDF

A comparison of shaping ability of four nickel-titanium rotary instruments in simulated root canals

  • Yun, Hyung-Hwa;Park, Jung-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.588.1-588
    • /
    • 2001
  • The purpose of this study was to compare the root canal shaping ability of four nickel-titanium rotary instruments. Forty eight simulated curved root canals were instrumented in plastic with the Crown-down technique using the $ProTaper^{TM}$ , the ProFile, the $GT^{TM}$, and the Quantec. Canals were instrumented until apical canal were up to size 30 by one operator. Each instrument was used only once and instrumentation time was measured.(omitted)

  • PDF

Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser

  • Gulsen Kiraz;Bulem Ureyen Kaya;Mert Ocak;Muhammet Bora Uzuner;Hakan Hamdi Celik
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.36.1-36.15
    • /
    • 2023
  • Objectives: This study aimed to compare the effectiveness of a single-file reciprocating system (WaveOne Gold, WOG) and a multi-file rotary system (ProTaper Universal Retreatment, PTUR) in removing canal filling from severely curved canals and to evaluate the possible adjunctive effects of XP-Endo Finisher (XPF), the Self-Adjusting File (SAF), and an erbium, chromium: yttrium, scandium, gallium garnet (Er,Cr:YSGG) laser using microcomputed tomography (µCT). Materials and Methods: Sixty-six curved mandibular molars were divided into 2 groups based on the retreatment technique and then into 3 based on the supplementary method. The residual filling volumes and root canals were evaluated with µCT before and after retreatment, and after the supplementary steps. The data were statistically analyzed with the t-test, Mann-Whitney U test, analysis of covariance, and factorial analysis of variance (p < 0.05). Results: PTUR and WOG showed no significant difference in removing filling materials (p > 0.05). The supplementary techniques were significantly more effective than reciprocating or rotary systems only (p < 0.01). The supplementary steps showed no significant differences in canal filling removal effectiveness (p > 0.05), but XPF showed less dentin reduction than the SAF and Er,Cr:YSGG laser (p < 0.01). Conclusions: The supplementary methods significantly decreased the volume of residual filling materials. XPF caused minimal changes in root canal volume and might be preferred for retreatment in curved root canals. Supplementary approaches after retreatment procedures may improve root canal cleanliness.

Comparison of root canal preparation by three Ni-Ti instruments

  • Shibutani, Takuya;Ozaki, Kazumi;Matsuo, Takashi
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.547-547
    • /
    • 2003
  • The aim of this study was to compare the effects of three Ni-Ti instruments on leaning ability by evaluating the volumetric and morphological changes in the apical 6mm of the root canals before and after preparation, using three-dimensionally reconstructed root canals of extracted human teeth. Forty-five teeth were used in this study. They were opened the chambers and removed the all pulp remnants ultrasonically. Subsequently, the canal wall was coated with silver paste and prepared using ProTaper, ProFile and GT rotary files according to the manufacturers instructions. Before and after root canal preparation, all the specimens were scanned with micro computed tomography and examined the differences in dentine volume removed, canal straightening, the proportion of the unchanged area and canal transportation. Quantitative analysis revealed that instrumentation increased in canal volume ranging between 0.081 and $1.866{\;}\textrm{mm}^3$. On average, the large apical preparation produced by ProTaper demonstrated smaller proportions of unchanged surface areas compared to the two other instruments in small canals. But in large canals like maxillary central incisor, the preparation of ProTaper instruments was not enough. ProTaper instrument was tended to increase more in canal volume as compared with the other two instruments but unchanged area was no significant difference. These results showed that three instruments had similar preparation ability and micro computed tomography in combination with the coated wall of root canal using silver paste is a nondestructive and valuable tool to study root canal geometry and changes after preparations in detail.

  • PDF

Drainage Simulation in Fourdrinier Paper Machine (장망초지기에서 탈수 시뮬레이션)

  • 김용식;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.3
    • /
    • pp.10-17
    • /
    • 2000
  • The MDDA(Modified Dynamic Drainage Analyzer) was developed to evaluate the drainage at hydrofoil table roll and low vacuum devices on fourdrinier paper machine MB-former. Comparison of the results was obtained using a computer simulation system based on Taylor's equation and filtration equation and by measuring the consistency profile in a paper machine presented an agreement within 10.7% This device can evaluate the dewatering pro-file on wire for various stock properties adjust dewatering devices on fourdrinier paper machine and control the dosage of retention aids for improving paper structural properties and runnability of papermachine.

  • PDF