• Title/Summary/Keyword: Priority evacuation

Search Result 25, Processing Time 0.021 seconds

Comparative Study on Predictions of Passengers' Evacuation Performances Before and After the Remodelling of MV SEWOL (세월호 증개축 전후 승선객의 피난성능 예측비교)

  • Hwang, Kwang Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.105-114
    • /
    • 2015
  • Even though the passengers' safety has priority on Passenger ship, there is no criterion on the evacuation performance related with human behavior. To uncover the potential problems of domestic criteria on safety of passenger ships, this study performed simulation ad analysis the evacuees safety before and after the Sewol's remodelling. It is clear that the assembly stations of both before and after Sewol remodelling have sufficient areas to satisfy the domestic criterion by simply human- body's-area, but those are failed to assemble all the passengers by the simulation tool that reflects the human behaviors' characteristics. For the healing angle as 0 degree, and the criteria of SOLAS, it was found out that all the passengers can safely evacuate from each cabins to the embarkation stations for both of the before-and-after the Sewol remodelling. But for the healing angle as 20 degree, both of the before-and-after Sewol remodelling are evaluated as possible to make all the passengers evacuate for day scenario and impossible for night scenario of SOLAS criteria. And because of the worse conditions after the remodelling, the probabilities of Sewol(before) are showed wide band comparing to Naminoue (after).

Study on Firefighting Education and Training Applying Virtual Reality (가상현실을 적용한 소방교육·훈련에 관한 연구)

  • Chae, Jin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.108-115
    • /
    • 2018
  • The purpose of this study was to classify VR programs according to their characteristics and associations by the disaster management phase and firefighting school curriculum, and set priorities among VR fire training and training programs using AHP analysis., The relative priority is given considering its importance and urgency. As a result of the study, firefighting education and training classes showed the highest level of response. The relative priority of the subcategories was highest in the prevention stage. The simulation implementation for the evacuation experience was highest in closed spaces, such as a subway, and the simulation for the special firefighting vehicle was highest in the contrast phase. In the response phase, real fire simulation training was the highest. In the recovery phase, virtual reality training was the most effective in determining the fire situation based on the fire database.

Development of Large Fire Judgement Model Using Logistic Regression Equation (로지스틱 회귀식을 이용한 대형산불판정 모형 개발)

  • Lee, Byungdoo;Kim, Kyongha
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.3
    • /
    • pp.415-419
    • /
    • 2013
  • To mitigate forest fire damage, it is needed to concentrate suppression resources on the fire having a high probability to become large in the initial stage. The objective of this study is to develop the large fire judgement model which can estimate large fire possibility index between the fire size and the related factors such as weather, terrain, and fuel. The results of logistic regression equation indicated that temperature, wind speed, continuous drought days, slope variance, forest area were related to the large fire possibility positively but elevation has negative relationship. This model may help decision-making about size of suppression resources, local residents evacuation and suppression priority.

A Study on the Critical Safety Management Buildings and factors by Analyzing the Actual State of Building Safety Management (건축물 안전관리 실태분석을 통한 중점안전관리 대상 및 요소 설정에 관한 연구)

  • Kim, Eun-Hee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.4
    • /
    • pp.37-44
    • /
    • 2019
  • According to the statistical surveys and studies, insufficient maintenance in the use of existing buildings caused fire and collapse accidents. In this respect, I analyzed the data managed by the current building maintenance and inspection system to find out the actual state of safety management and proposed two significant results. First, regarding the state of the buildings, the safety management status of the small-sized ones, where 20 years or more passed after construction, is the worst and a priority improvement plan is required. Second, there are eight deeply concerning factors for the fire incidents and collapse accidents of buildings. In the order of high risk, these factors are structural strength (seismic design), exterior wall finishing material, basement floor, interior finishing materials, other evacuation facilities, corridors stairs entrances, rooftop, fire partition. We need to have more special designs and management plans regarding high-risk factors as a system to prevent accidents in the building.

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.

A Study on Decisions on Investment Factors in the Development of Local Fishing Harbors (지방어항개발의 투자결정요인 분석 - 충청남도 어항 중심으로 -)

  • Lee, Kwang-Nam;Jung, Jin-Ho;Choi, Jae-Wook
    • Ocean and Polar Research
    • /
    • v.33 no.4
    • /
    • pp.473-483
    • /
    • 2011
  • In the recent WTO/DDA negotiations, discussions are progressing to forbid fishery subsidies which have negative effect on the natural environment and the fishery resources and to lower or to eliminate the tariff/non-tariff barriers that distort trade liberalization. As a result, linking to the weak structural environment of Korea's fishing villages; such a scheme has jeopardized the livelihood of fishermen who settle down in local fishing harbors. Against this backdrop, the government is attempting to positively respond to changes in the fishing environment in a number of different ways: promotion of fishing tourism, fishing harbor reinforcement in function, developing fishing villages, and harbors. With respect to investment by priority in fishing harbor development, it is very important to appropriately select investment targets based on objective criteria. A small number of harbors are chosen and investment plans by harbor are systematically devised, economic feasibility and the effects of investment are analyzed and reviewed in relation to each target harbor. This paper is designed to review and assess objective evaluation methods and the degree of importance for the designation of target harbors, dealing with local harbors in Chung Nam Do as a model. Each local government has tried to reorganize existing harbors and develop new harbors, considering a fall in the number of fishing vessels and the expansion of maritime leisure activities. In order to overcome the limit of existing harbors in function, to raise the income of fishermen, and to activate tourism, they have shifted their focus from simple functions such as vessel evacuation and anchoring to harbor beautification, which can work as a basis for fishing tourism. This paper points out that the AHP analysis method for prioritizing local harbors in Chung Nam Do should help to be chosen target harbors in other cities and provinces. Each local government has attempted to reorganize existing harbors and to develop new harbors, taking into consideration the decline in the number of fishing vessels and the expansion of maritime leisure activities. In order to overcome the limited number of functional harbors, to raise the income of fishermen, and to boost tourism, they have shifted their focus from simple functions, such as vessel evacuation and anchoring, to harbor beautification, which can work as a basis for fishing tourism. This paper shows that the AHP analysis method for prioritizing local harbors in Chungcheongnam-do could aid in the effective selection of target harbors in other cities and provinces.

A Study on Egress Algorithm for High-rise Buildings Using Egress Simulation (피난시뮬레이션을 이용한 초고층건물의 피난 알고리즘 연구)

  • Kim, Won Kook;Seo, Dong Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • When the fire in the high-rise building was not extinguished in its early stage and propagated over its origin, safe egress becomes one of the most important factor to minimize the casualties. Recently fire protection for high-rise building has been reinforced after experiencing the series of disastrous fires. But, we still find many high-rise buildings do not comply with those reinforcement. And also there is a possibility of failure of reinforced fire protection system. Under these situation safe egress guide would be the final layer of protection. In this study existing egress methods were identified and evaluated. According the result of study, priority in egress should be given to the tenants on the floor of fire origin and floors exposed to the risk of fire. Then, the rest of the tenants can be evacuated simultaneously. Floors exposed in fire risk shall be determined by fire tests and/or fire simulations. But, the result of fire monitoring shall override preliminary estimations. Egress time for each algorithm was estimated by egress simulation and the result was compared. There was a little difference in egress time between total egress and phased egress, and a big difference between using stairs only and using elevators and stairs together. to a constant thickness between layers constituting a firefighter's protective clothing should be considered in the future.

A Study on the Crisis Management Standard Manual for Large-scale Human Accident at Workplace for Efficiency of Disaster Response (재난대응 효율화를 위한 사업장 대규모 인적사고 위기관리 표준매뉴얼 개정방안 연구)

  • Woo Sub Shim;Sang Beam Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.656-664
    • /
    • 2023
  • Purpose: The Ministry of Employment and Labor manages disasters based on the standard manual for risk management of large-scale human accidents in workplaces when large-scale disasters such as fires and collapses occur in workplaces. We are going to check the standard manual currently in operation and suggest improvement plans for the insufficient items. Method: Accordingly, the standard manual was checked together with internal and external experts in the disaster management manual and disaster management staff at headquarters and local government offices, and items to be improved were identified with priority. Result: In case of a collapse accident, it is necessary for the Ministry of Public Administration and Security to accurately present the selection criteria in order to eliminate the controversy over the selection of the disaster management department. In addition, it seems necessary to supplement the details of the disaster safety communication network operation and evacuation guidelines. Conclusion: In the future, in order to improve the disaster management system that meets the public's eye level, it is expected to prepare a standard manual for risk management of large-scale human accidents in workplaces that guarantees the lives and safety of workers through the collection of opinions from experts in the relevant field, disaster management personnel, and the general public.

An analysis study for reasonable installation of tunnel fire safety facility (터널 방재설비의 합리적 설치를 위한 분석적 연구)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Park, Byoung-Jik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.243-248
    • /
    • 2015
  • Domestic road and railroad construction have been increasingly growing and for reasons of mitigating traffic congestion, urban plan and refurbishment project, deeper and longer tunnels have been built. The event of fire is the most fatal accident in a tunnel, and it can be very disastrous with a high possibility. In this study, QRA (Quantitative Risk Analysis) which is one of quantitative risk analysis approaches was applied to tunnel fire safety design and the evaluation of QRA cases and the cost comparison of QRA methods were carried out. In addition analysis of risk reduction effect of tunnel fire safety system was conducted using AHP (Analytic Hierarchy Process) and the priority of major factors that could mitigate the risk in tunnel fire was presented. As a result, significant cost reduction effect could be obtained by incorporating QRA and it is expected to design fire safety system rationally. The priority of fire safety system based on risk mitigation effect by fire safety system considering the cost is in order of water pipe, emergency lighting, evacuation passage and smoke control system.

A Method to Develop Security System through the Analysis on Dangerous Case (위해사례분석을 통한 경호제도의 발전방안)

  • Yu, Hyung-Chang;Kim, Tae-Min
    • Korean Security Journal
    • /
    • no.16
    • /
    • pp.161-187
    • /
    • 2008
  • The purpose of this study is to suggest a development method of current Korean security system by analyzing the problems shown in the performance of security work in relation to the terrorism, which is enlarging in the word, from various aspects. In order to perform the study, the researcher considered the basic theory concerned to current Korean law concerned to security, principle and methodology of security, terror and new terrorism. The researcher performed the study by selecting qualitative case study focused on Park Geun-Hye case. Through the study, the methods to develop Korean security system are as follows. First, from the legal aspect, it is necessary to establish the law concerned to terrorism prevention and important person security. Moreover, it is necessary to search for the development of private security by revising Security Industry Act, which is a legal ground of private security. Second, it is necessary to improve and reinforce education & training program, which is not still divided in detail from the aspect of private security cultivation. Moreover, it is necessary to activate personal protection work and enlarge market through Security Industry Act and make an effort to change social recognition over security, which is devaluated in the society. From the viewpoint, national license about private security shall be adopted. The department of president security, which is a representative of official security, shall transfer the advanced technology to private security organization. Third, from the aspect of operation, the operation of security based on SCE principle, human shield principle, the nearest person's protection principle, body extension principle, linear protection principle and evacuation priority principle is required. Therefore, the priority shall be given to preventive security and thorough security plan shall be made for the operation.

  • PDF