• 제목/요약/키워드: Prior-Treatment

검색결과 1,739건 처리시간 0.025초

7075 합금의 압출에서 원소재 빌렛과 압출재의 열처리에 따른 미세조직 및 기계적 특성 분석 (Analysis of Microstructures and Mechanical Properties of Billet and Extrudate according to Heat Treatment for the Extrusion of 7075 alloy)

  • 이상용
    • 열처리공학회지
    • /
    • 제33권5호
    • /
    • pp.232-238
    • /
    • 2020
  • Heating experiments using the 7075 aluminum alloy in the state of billet and extrudate have been performed to investigate the pertinent ranges of working temperatures and holding times for the application to the various automobile parts. The 7075 specimens from raw billet of 152 mm in diameter and 400 mm in length prior to extrusion were used for heating with a holding time of 10 minutes at temperatures between 380℃ and 550℃. Then, an extrusion process using the billet has been fulfilled at 380℃ with extrusion speed of 0.8 mm/min to get an plate-type extrudate of 75 mm in width and 4.2 mm in thickness. The samples from the extrudate were subjected to heating experiments at temperatures between 380℃ and 440℃ with holding times such as 10 min, 30 min, 60 min and 120 min at each heating temperature. The microstructures were investigated on the optical and EBSD micrographs. The hardness measurement and the tensile test have been performed to investigate the effect of the heat treatment on the mechanical property. The results showed for the 7075 extrusion process that the safe heating of billet can be performed below 450℃ and the extrusion can be done safely up to 400℃.

울산반구대암각화 보존처리를 위한 현장적용실험 (Field Experiments of Scientific Conservation Treatment for Bangudae Petroglyphs in Ulsan, South Korea)

  • 이태종;오정현;김사덕
    • 보존과학연구
    • /
    • 통권33호
    • /
    • pp.69-83
    • /
    • 2012
  • 울산 반구대 암각화는 1965년 축조된 사연댐으로 인해 매년 4~8개월간 침수와 노출을 반복하면서 훼손이 진행되고 있다. 이에 직접적 보존처리에 앞서 현장적용실험을 위한 사이트를 선정하여 각각의 손상을 제어할 수 있는 보존처리를 실시하였다. 모든 처리에는 비파괴조사를 실시하여 처리 전 후를 정량적으로 평가하였으며 모니터링을 위한 기초자료를 구축하였다. 실험 결과 처리재료보다 처리기술과 적용방법에 따라 처리효과에서 큰 차이를 보였다. 특히 에틸실리케이트 수지를 이용한 강화처리는 처리방법에 따라 초음파 속도 및 에코팁 경도상승이 확연히 구분된 결과를 도출하였다.

  • PDF

식물을 이용한 오수의 고도처리에 관한 연구 (A Study on the Advanced Treatment of Wastewater by Plants)

  • 이용두;김현희
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.75-81
    • /
    • 1999
  • In recent years increasing production and disposal of wastewater have caused an accelerated eutrophication of receiving waters. Therefore, in order to alleviate the detrimental impact of wastewater discharge, there is an increasing demand for removing the main nutrients, nitrogen and phosphorus, as well as the organic content of the waste water prior to disposal. This is effectively achieved by extended conventional treatment technology. However, the working expenses and energy requirements of such advanced treatment systems are rather high. So in a sparsely populated rural community is required development of wastewater treatment system combined with the regional characteristics. In this study, the systems are planted with Reeds and Amaryllis In A.C and estimated purification potential of system. The results obtained are as follows. BOD removal rate is 20% in the early stage, the last removal rate is 35% in A.C process and is 65% in Amaryllis+A.C process and is 50% in Reed+A.C process. T-N removal rate by Amaryllis is average 2.6g/$m^3$ㆍd, T-N removal rate by Reed is average 1.76g/$m^3$ㆍd. T-P removal rate by Amaryllis is average 0.27g/$m^3$ㆍd, T-P removal rate by Reed is average 0.25g/$m^3$ㆍd. BOD removal rate constant with retention time is 1.4494(1/d), T-N removal rate constant is 0.5428(1/d), T-P removal rate constant is 0.5287(1/d).

  • PDF

기판의 코로나 표면처리에 의한 탄소 나노튜브 투명전극의 물성 향상 (Improvement of Transparent Electrodes Based on Carbon Nanotubes Via Corona Treatment on Substrate Surface)

  • 한상훈;김부종;박진석
    • 반도체디스플레이기술학회지
    • /
    • 제13권1호
    • /
    • pp.7-12
    • /
    • 2014
  • In this study, we investigate the effects of corona-discharge pre-treatment on the properties of carbon nanotubes (CNTs) which are used as flexible transparent electrodes. The CNTs are deposited on PET (polyethylene terephthalate) substrates using a spray coating method. Prior to the deposition of CNTs, the PET substrates are corona-treated by varying the feeding directions of the PET substrate and the numbers of treatments. The variations in the surface morphologies and roughnesses of the PET substrates due to corona-treatment are characterized via atomic force microscopy (AFM). Dynamic contact angles (DCAs) of the corona-treated PET substrates are measured and analyzed as functions of the treatment conditions. Also, the sheet resistances and visible-range transmittances of the CNTs deposited on PET substrates are measured before and after bending test. The experimental results obtained in this study provide strong evidences that the adhesive forces between CNTs and PET substrates can be substantially enhanced by corona-discharge pretreatment.

계면층 형성 및 열처리가 탄소 나노튜브 미세팁의 전계방출 특성에 미치는 영향 (Effects of Interlayer Formation and Thermal Treatment on Field-emission Properties of Carbon Nanotube Micro-tips)

  • 김부종;박진석
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.1-6
    • /
    • 2013
  • The effects of interlayer formation and thermal treatment on the field-emission properties of carbon nanotubes (CNTs) were investigated. The CNTs were prepared on tungsten (W) micro-tip substrates using the electrophoretic deposition (EPD) method. The interlayers, such as aluminum (Al) and hafnium (Hf) were coated on the W-tips prior to CNT deposition and after the deposition of CNTs all the species were thermally treated at $700^{\circ}C$ for 30 min. The field-emission properties of CNTs were significantly improved by thermal treatment. The threshold electric field for igniting the electron emission was decreased and the emission current was increased. The Raman spectroscopy results indicated that this was attributed mainly to the enhancement of CNTs by thermal treatment. Also, the CNTs deposited on the interlayers showed the remarkably improved results in the long-term emission stability, especially when they were thermally treated. The X-ray photoelectron spectroscopy (XPS) measurement confirmed that this was resulted from the formation of the additional cohesive forces between the CNTs and the underlying interlayers.

Ag-CdO계 전기접점재료의 미세조직에 미치는 열처리 조건과 산화 공정의 영향 (The Effect of The Heat Treatment Condition and the Oxidation Process on the Microstructure of Ag-CdO Contact Materials)

  • 권기봉;남태운
    • 한국주조공학회지
    • /
    • 제25권6호
    • /
    • pp.226-232
    • /
    • 2005
  • Contact material is widely used in the field of electrical parts. Ag-CdO material has a good wear resistance and stable contact resistance. In order to establish optimizing heat treatment condition, rolling temperature and oxidation process, we studied the microstructure of Ag-CdO material with various conditions. The experimental procedure were melting using high frequency induction, heat treatment, rolling and internal oxidation. And we experimented on difference process, Post-oxidaion. In this study, we obtained the optimizing heat treatment condition was $700^{\circ}C$ for 15 min. and the optimizing rolling temperature was $730^{\circ}C$. In investigation of the microstructure of oxidized material, coarse oxide and depleted oxidation layer existed. The hardness was average Hv 70. When we used Post-oxidation, oxides were finer than prior process and depleted oxidation layer did not exist. The hardness of Post-oxidation material was average Hv 80. And the optimizing rolling temperature was $800^{\circ}C$.

초음파와 테이핑이 외측상과염 환자의 통증과 악력에 미치는 효과 (The Effects of Ultra sound and Taping Treatment on the Pain and Grip Strength in Lateral Epicondylitis)

  • 이문환;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제16권1호
    • /
    • pp.124-139
    • /
    • 2004
  • Taping treatment is frequently used in the management of musculoskeletal pain The purpose of this study was to assess the effectiveness of ultrasound and taping treatment on the pain and grip strength with lateral epicondylitis. Pain and grip strength were assessed prior, after first, after second, after third, after fourth, and after fifth treatment. All 6 times calculated pain and grip strength. To find out the effectiveness of taping treatment, we were divide two groups. the one group was consisted of 20 patients that treated with H/P, electrical therapy and ultrasound, and the other group was consisted of 20 patients that treated with H/P, electrical therapy and taping. The results were as follow: 1. There were statistical significance on the pain and grip strength with ultrasound group(P<0.05). 2. There were statistical significance on the pain and grip strength with taping group(P<0.05). 3. Taping group was more statistical significance than ultrasound group on the pain(P<0.05). 4. There was no statistical significance between ultrasound group and taping group on the grip strength(P>0.05).

  • PDF

A rare case of sacral epidural arteriovenous fistula with concomitant occult multiple lumbar epidural arteriovenous fistulas

  • Katsuya Saito;Takakazu Ushioda;Takahiro Miyata;Keita Mayanagi;Koki Kato;Joji Inamasu;Masashi Nakatsukasa
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제25권3호
    • /
    • pp.322-332
    • /
    • 2023
  • We describe a rare case of sacral epidural arteriovenous fistulas (edAVFs) with atypical clinical course of treatment. A 78-year-old man with a history of spinal surgery presented progressive gait disturbance and urinary incontinence. Spinal angiography demonstrated a sacral spinal AVF fed by bilateral lateral sacral arteries, draining to the venous pouch with subdural drainage. The first treatment by direct interruption of a subdural drainer was incompletely finished. Postoperative reassessment by 3D imaging analysis led to the diagnosis of sacral edAVF and 3D understanding of its angioarchitecture. The second treatment by transarterial embolization (TAE) resulted in complete occlusion of a sacral edAVF. However, spinal venous congestion didn't improve, because the recruitment of occult edAVFs at the multiple lumbar levels and complex-shaped sacral ventral epidural venous plexus (VEP) were involved in the remnant of prior subdural drainage. The third treatment was performed by TAE for three occult edAVFs and the VEP compartment connecting between a patent edAVF and subdural drainage, which resulted in complete disappearance of spinal cord edema. Endovascular embolization of VEP compartment connecting to subdural drainage in addition to fistulous occlusion may be one of the treatment options for several edAVFs at the multiple spinal levels.

선천성 범뇌하수체저하증(Congenital panhypopituitarism) 환자의 전신마취 하 치과치료 (DENTAL TREATMENT IN A PATIENT WITH CONGENITAL PANHYPOPITUITARISM UNDER GENERAL ANESTHESIA)

  • 김현태;송지수;현홍근;김영재;김정욱;장기택;이상훈;신터전
    • 대한장애인치과학회지
    • /
    • 제15권1호
    • /
    • pp.70-73
    • /
    • 2019
  • 선천성 뇌하수체저하증(Congenital panhypopituitarism)은 갖는 환자는 스트레스에 대한 대처 능력이 떨어지기 때문에 치과치료 전 발생할 수 있는 부신 급성발증(adrenal crisis)에 대해서 미리 대비하는 것이 중요하다 스트레스를 유발하는 치과치료 시행 시 호르몬 대체 요법의 시행을 고려해야 한다. 치과치료 전 환아의 연령과 전신상태를 고려하여 적절한 치료 방법을 선택해야 할 것이며 비정상적인 악안면 성장 패턴을 보일 가능성이 있으므로 성장관찰을 동반한 정기 검진이 요구된다.

Plasmodium falciparum Genotype Diversity in Artemisinin Derivatives Treatment Failure Patients along the Thai-Myanmar Border

  • Congpuong, Kanungnit;Hoonchaiyapoom, Thirasak;Inorn, Kornnarin
    • Parasites, Hosts and Diseases
    • /
    • 제52권6호
    • /
    • pp.631-637
    • /
    • 2014
  • Genetic characteristics of Plasmodium falciparum may play a role in the treatment outcome of malaria infection. We have studied the association between diversity at the merozoite surface protein-1 (msp-1), msp-2, and glutamate-rich protein (glurp) loci and the treatment outcome of uncomplicated falciparum malaria patients along the Thai-Myanmar border who were treated with artemisinin derivatives combination therapy. P. falciparum isolates were collected prior to treatment from 3 groups of patients; 50 cases of treatment failures, 50 recrudescences, and 56 successful treatments. Genotyping of the 3 polymorphic markers was analyzed by nested PCR. The distribution of msp-1 alleles was significantly different among the 3 groups of patients but not the msp-2 and glurp alleles. The allelic frequencies of K1 and MAD20 alleles of msp1 gene were higher while RO33 allele was significantly lower in the successful treatment group. Treatment failure samples had a higher median number of alleles as compared to the successful treatment group. Specific genotypes of msp-1, msp-2, and glurp were significantly associated with the treatment outcomes. Three allelic size variants were significantly higher among the isolates from the treatment failure groups, i.e., $K1_{270-290}$, $3D7_{610-630}$, $G_{650-690}$, while 2 variants, $K1_{150-170}$, and $3D7_{670-690}$ were significantly lower. In conclusion, the present study reports the differences in multiplicity of infection and distribution of specific alleles of msp-1, msp-2, and glurp genes in P. falciparum isolates obtained from treatment failure and successful treatment patients following artemisinin derivatives combination therapy.