• 제목/요약/키워드: Printing System

검색결과 790건 처리시간 0.029초

Fixed prostheses fabricated by direct metal laser sintering system: case report (Direct metal laser sintering 방식을 이용하여 제작한 다양한 고정성 보철물 수복 증례)

  • Baek, Ju-Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제32권3호
    • /
    • pp.246-254
    • /
    • 2016
  • Nowadays, 3 dimentional (3D) printing, especially Direct Metal Laser Sintering (DMLS) system is used in dentistry. DMLS system has recently been introduced for fabrication metal framework for metal ceramic crowns to overcome the disadvantages of the casting method and computer aided design/computer aided manufacturing (CAD/CAM) milling system. DMLS system uses a high-temperature laser beam to selectively heat a substructure metal powder based on the CAD data with the framework design. A thin layer of the beamed area becomes fused, and the metal framework is completed by laminating these thin layers. Utilizing DMLS system to fabricate fixed prostheses is expected to achieve free-from shaping without mold and limitations from cutting tools, fabricate prostheses with complex geometry, prevent distortion and fabrication defects that inherent to conventional fabrication methods. The purpose of this case report is to demonstrate various fixed prostheses such as long span fixed prostheses, post to achieve satisfactory results in functional and esthetic aspects.

Study on Development of Automation System for Non-Contact Counting of ID Card (비접촉 ID카드 계수를 위한 자동화 시스템 개발)

  • Kang, Dae-Hwa;Hong, Jun-Hee;Guo, Yang-Yang;Lee, Hyok-Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제22권4호
    • /
    • pp.652-657
    • /
    • 2013
  • In this study, we developed a counting method for non-contact ID cards using an optical fiber displacement sensor instead of the traditionally used friction counting method. The proposed method has the advantage of high speed and automated measurement. For counting non-contact ID cards, an H-type optical fiber sensor, jig part, and counting program are developed separately to build the system and adjust it. Through the experimental test results, it was confirmed that counting is possible with one type of international ID card and one type of financial security card based on ISO7810. Furthermore, by applying the proposed method to 100 ID cards 100 times repeatedly, it was confirmed that it has high accuracy and an error ratio of 0%. We experimentally demonstrated that the proposed counting method for non-contact ID cards using an optical fiber displacement sensor can perform measurements with high accuracy and high speed.

Development of Methods for Detecting Inkjet Malfunction (잉크젯 헤드의 오작동 검출 방법 개발)

  • Kwon, Kye-Si;Go, Jung-Kook;Kim, Jin-Won;Kim, Dong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제34권10호
    • /
    • pp.1529-1535
    • /
    • 2010
  • For the reliable use of inkjet technology as patterning tools, the jetting of the inkjet dispenser needs to be monitored for real-time detection of any malfunction. We present a self-sensing circuit that can be used to detect jetting failure by measuring electrical signals only. In addition, practical problems involved in the monitoring of inkjets in multinozzle printheads are discussed. In the study, software was developed and presented to demonstrate the feasibility of the proposed method for detecting inkjet jetting failure in a printing system.

A Study on the Drop Formation of the Liquid Jet Device for Rapid Prototyping (신속 시작법용 액적 생성 장치에서의 액적 생성에 대한 연구)

  • Lee, U-Il;Kim, Seon-Min;Park, Jong-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제25권8호
    • /
    • pp.1021-1029
    • /
    • 2001
  • Rapid prototyping(RP) is a novel technology to create 3D products directly from CAD system. This study proposes a new RP method which uses the PZT ceramic plate to make a Drop-On-Demand liquid jet from the nozzle. The characteristic of drop formation in the new system is investigated both numerically and experimentally. The optimal drop for 3-D Printing can be obtained by the proper amplitude and frequency of the applied voltage. Also the process of the drop formation is analyzed using the pressure wave theory and verified by numerical simulation. First, the pressure wave generated by the deformation of the Piezo-plate at the nozzle is analyzed by solving the 2D axisymmetric wave equation via Finite Element Method. Finally, the drop formation process is simulated using a commercial software, FLOW 3D considering the pressure at the nozzle obtained by solving the wave equation as the boundary condition.

A Study on the LQG Precision Tension Control of a Dancer System for a Production of Printed Electronics in Roll-to-roll Systems (Roll-to-roll 시스템에서 인쇄전자 생산을 위한 댄서 시스템의 LQG 정밀 장력 제어에 대한 연구)

  • Seong, Jin-Woo;Kang, Hyun-Kyoo;Shin, Kee-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제26권10호
    • /
    • pp.65-73
    • /
    • 2009
  • For mass production of printed electronics in roll-to-roll fashion, precision tension control is important to reduce register errors. Register error should be minimized within several to tens of microns for many electronic devices to be manufactured through printing technology. In order to achieve this goal, tension disturbance must be attenuated before printing process within a certain range. In this paper, a certain tension range which allows maintaining register error within 10 micron was defined with specific operating conditions. A LQG controller was proposed instead of the conventional PI controller for precision tension control using a multivariable feedback. A guideline to determine design parameters for calculating LQ gain was proposed. The proposed LQG controller was compared to both PI controller and LQ regulator with white noise by numerical simulations. Results showed that the proposed LQG controller was effective for attenuating tension disturbance with white noise.

Perfonnance Evaluation of Single Cell and Stack of PolymerElectrolyte Fuel Cell by Using Transfer Printing Technique

  • KIM, CHANG SOO;CHUN, YOUNG-GAB;PECK, DONG-HYUN;YANG, TAE-HYUN
    • Journal of Hydrogen and New Energy
    • /
    • 제11권1호
    • /
    • pp.19-27
    • /
    • 2000
  • The polymer electrolyte membrane fuel cell (PEMFC) system was developed. In order to enhance the performance of membrane electrode assembly (MEA), the transfer printing method of the electrocatalyst layer on membrane was developed. The $H_2/O_2$ single cell with an electrode area of $50cm^2$ was fabricated and tested using 20 wt.% Pt/C as an electrocatalyst and the commercial and hand-made MEA such as Nafion 115, Hanwha, Dow, Flemion T and Gore Select. The 100-cell PEMFC stack with an active electrode area of $300cm^2$ was designed and fabricated using 40 wt.% Pt/C and 30 wt.% Pt-Ru/C as a cathode and anode electrocatalysts, respectively. The performance of PEMFC system was obtained to be 7kW (250A at 28V) and 3.5kW (70A at 50V) at $80^{\circ}C$ by flowing $H_2/air$ and methanol reformed fuel gas/air, respectively.

  • PDF

Comparison of Time study in Film-based versus PACS : Computed Tomography (시간분석법에 의한 필름시스템과 PACS의 비교 연구 : CT촬영을 중심으로)

  • Kweon, Dae-Cheol;Jeong, Woo-Jin;Chung, Kyung-Mo;Lee, Yong-Woo;Lee, Je-Ho
    • Korean Journal of Digital Imaging in Medicine
    • /
    • 제5권1호
    • /
    • pp.78-84
    • /
    • 2002
  • To evaluate the relative time required to perform a CT(computed tomography) examination in a filmless versus a film-based system and helical versus nonhelical studies. Time and Motion studies were performed in 175 consecutive CT examinations. Images from 85 examinations were electronically transferred to a PACS, and 90 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a radiological technologist to complete a CT examination was reduced by 43% with the PACS compared with the film-based system and nonhelical was reduced 10-20% with helical studies. This reduction was due to the elimination of a transfer and printing, such as the printing at window or level settings. The use of PACS can result in the elimination of time tasks for the radiological technologist, resulting in marked reduction in examination time. This reduction can result in decreased cost and increased productivity in PACS operation.

  • PDF

Emission Characteristics of Power Type Electroluminescent Device (분산형 전계발광 소자의 발광 특성)

  • 권순석;임기조;박수길;김현후;류부형;김용주
    • Electrical & Electronic Materials
    • /
    • 제10권2호
    • /
    • pp.150-155
    • /
    • 1997
  • Powder type electroluminescent device(P-ELD) in this study was prepared by printing method. P-ELDs were basically composed of phosphor, insulator and transparent conducting layer. The phosphor powder was prepared by sintering the mixture of ZnS as a host, Cu as an activator, and NaCl as a flux for co-activator and enhancement of growth of the phosphor particles. The phosphor layer was made by printing the paste of the cyanoethylpullan as a binder and the ZnS system phosphor powder. In order to evaluate the luminescence characteristics of ZnS P-ELD, applied voltage - luminance(V-L), frequency-luminance(f-L), and relative luminance spectra(L- .lambda.) characteristics were measured. The experimental results show that luminance increased with increasing the applied voltage and frequency. It can be explained in terms of the potential barrier formed between ZnS and CuS. Two emission peaks in luminance-wavelength spectra measured at applied voltage of 100 $V_{rms}$ were observed at 500nm as a primary peak and 460nm as a secondary peak, respectively.y.

  • PDF

The Publication and Bibliographical Characteristics of Hyangyak Jipseongbang During Early Joseon Period (조선전기(朝鮮前期) 『향약집성방(鄕藥集成方)』의 간행과 서지학적 특징)

  • Ok, Young-Jung
    • The Journal of Korean Medical History
    • /
    • 제29권1호
    • /
    • pp.55-69
    • /
    • 2016
  • This study examined the bibliographical characteristics of Hyangyak Jipseongbang that was compiled in the $15^{th}$ century (1433) and continued to publish throughout the early period of Joseon Dynasty. Various existing records and the early Joseon printed edition of Hyangyak Jipseongbang stored in a domestic Sancheong Korean Medicine Museum were reviewed from 3 perspectives as follows. First, it is the bibliographical system approach to Hyangyak Jipseongbang for some circumstances related to its compilation and publication. Second, it is the significance in terms of printing history through the analysis of bibliographical characteristics and the status of the remaining Hyangyak Jipseongbang. Particularly, the period of publication is an important factor to determine the value of a book. In this respect, most of the extant early-Joseon editions of Hyangyak Jipseongbang seem to have been published during the ruling years of King Sung Jong. Those editions are expected to have distinctive meaning from other copied editions of the $17^{th}$ century. Last, it is bibliographical orignal analysis of Hyangyak Jipseongbang. This study reviewed the contents and composition of Vol. 49 through 51 of Hyangyak Jipseongbang stored in Sancheong Korean Medicine Museum in an attempt to help understand the textual bibliography and composition system of exhibiting editions.