• Title/Summary/Keyword: Printing Design

Search Result 770, Processing Time 0.03 seconds

The Proposal of a Small-Size Business Model based on a 3D Printer : Focused on Sunglasses for Children (3D 프린터를 활용한 소규모 비즈니스 모델 제안 : 유아동 선글라스를 중심으로)

  • Kim, Se-yeong;Kim, Suk-Rae
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.455-464
    • /
    • 2018
  • Recognizing the shortage of information about business models to generate profit despite the designers' recent interest in 3D printers as a new creative tool, this study set out to make sunglasses for young children, which lacked diversity in sizes according to age due to the small market scope under the old mass production system, by taking advantage of 3D printers' strength in the small batch production of customized products and propose a practical example to be expandable as a small-size business model. For these purposes, the investigator summarized the basic information about the 3D printing technology and the basic structure of sunglasses and made a size table to manufacture sunglasses for young children by analyzing the size table for vision correction. After this series of work, the study presented final product with the production costs and demonstrated that sunglasses for young children made with a 3D printer could be a practical case expandable as a competitive small-size business model in the market.

A Study on the Fabrication and Comparison of the Phantom for Computed Tomography Image Quality Measurements Using Three-Dimensions Printing Technology (삼차원 프린팅 기술을 이용한 전산화단층영상 품질 측정용 팬텀 제작 및 비교 연구)

  • Yoon, Myeong-Seong;Hong, Soon-Min;Heo, Yeong-Cheol;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.595-602
    • /
    • 2018
  • Quality control (QC) of Computed Tomography (CT) devices is based on image quality measurement on AAPM CT phantom which is a standard phantom. Although it is possible to control the accuracy of the CT apparatus, it is expensive and has a disadvantage of low penetration rate. Therefore, in this study, we make image quality measurement phantom at low cost using FFF (Fused Filament Fabrication) type three-dimensional printer and try to analyze the usefulness, compare it with existing standard phantom. To print a phantom, We used three-dimensional printer of the FFF system and PLA (Poly Lactic Acid, density: $1.24g/cm^3$) filament, and the CT device of 64 MDCT (Aquilion CX, Toshiba, Japan). In addition, we printed a phantom using three-dimensional printer after design using various tool based on existing standard phantom. For image quality evaluation, AAPM CT phantom and self-generated phantom were measured 10 times for each block. The measured data were analyzed for significance using the Mannwhiteney U-test of SPSS (Version 22.0, SPSS, Chicago, IL, USA). As a result of the analysis, phantom fabricated with three-dimensional printer and standard phantom showed no significant difference (p>0.05). Furthermore, we confirmed that image quality measurement performance of a phantom using three-dimensional printer is similar to the existing standard phantom. In conclusion, we confirmed the possibility of low cost phantom fabrication using three dimensional printer.

An Assessment of the Multiple Challenges Associated with Student's Access to Electronic Resources at a Public University Library in Ghana

  • Armah, Nesba Yaa Anima Adzobu;Cobblah, Mac-Anthony
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.11 no.1
    • /
    • pp.65-84
    • /
    • 2021
  • Our understanding of how barriers to access systematically varies with the compositional and contextual characteristics of users is incomplete. Using a public university library in Ghana, this study assessed the heterogeneous barriers or constraints students encounter in accessing electronic resources based on their demographic and contextual attributes. A descriptive survey design was adopted and structured questionnaires were administered randomly to 558 students in the four constituent colleges of the University of Cape Coast, Ghana. Data were collected and analysed using SPSS and descriptive statistics were generated. The results revealed that students faced six key challenges in accessing electronic information resources in the library namely delays in download of information, poor internet connectivity, and limited accessibility of university portal, inadequate computers in the library, poor lighting and limited ancillary services (on the spot printing facilities), with differences based on gender, academic level, and college affiliation. Only 24% males and 26% females had no challenges or problems with delays in download of electronic information. About three-fourth of all users had poor internet connectivity and complained about inadequate computers associated with accessing electronic resources. 40% percent of undergraduate students in the Colleges of Education Studies, Agriculture and Natural Sciences, and Humanities and Legal Studies each encountered four to six simultaneous challenges. Irrespective of gender, first year undergraduate students in all the four colleges were the least likely to report multiple challenges. This suggests the need for targeted and context-specific interventions to address the identified challenges.

A Study on the Tile Mural Decoration Design Using Colored Glass Plaster Technique (색유리 플래스터 기법을 이용한 타일 벽장식 방안 연구)

  • Kim, Seung-Man
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.12
    • /
    • pp.460-470
    • /
    • 2020
  • In modern life, interior decoration has been transformed into a psychological synergistic effect of space, greatly affecting human sensibility. The main point of view in this paper is to study the discovery of new decorative effects and the possibility of products that can replace imported tiles, which account for more than 60% of the walls of indoor spaces closely related to daily life. The solution is to create point tiles using color glass plaster techniques developed in 2018 and to explore the possibility of decorating art walls to meet consumers' purchasing needs using simulations. The four patterns applied to the a paintbrush, resist printing, cutting technique, and inlaid patterns, and the traditional color development effect of the medium color suited to our sensibilities was studied. In addition, through simulation, art walls and acrylic using color glass styles were also used in the kitchen, living room and empty space of the bathroom. Based on this research, ceramic point tiles with a new perspective will be explored and the interior using walls will be activated.

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

Pressure/Flow Pulsation Characteristics of the Hydraulic System for Behaviour Prediction of the Prefill Valve (프리필 밸브의 거동 예측용 유압 시스템의 압력/유량 맥동 분석)

  • Park, Jeong Woo;Khan, Haroon Ahmad;Jeong, Eun-A;Kwon, Sung-Ja;Yun, So-Nam;Lee, Hue-Sung
    • Journal of Drive and Control
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2021
  • In this work, a circuit with a hydraulic power unit is formulated as a means of predicting the behavior of the prefill valve in the future. The behavior of the prefill valve can be examined by the measurements of the configured power unit, and the performance is determined by using hydraulic pumps, relief valves, and hydraulic hoses that make up the power unit. In particular, pressure/flow pulsation generated by hydraulic pumps can cause instability in the prefill valve and cause noise-induced degradation of the overall performance and reliability of the hydraulic system containing the prefill valve. Therefore, to study the behavior and performance of the prefill valve in a relatively accurate manner, the prediction of the characteristics of the hydraulic power unit driving the prefill valve is very important. In this study, the pulsation characteristics of the hydraulic pump were analyzed to theoretically demonstrate its relationship with different settings of the power unit, such as relief valve pressure settings and the presence/absence of the hose.

CPW-fed UWB Monopole Paper Antenna (CPW 급전 UWB 모노폴 종이 안테나)

  • Park, Dong-Kook
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.607-612
    • /
    • 2021
  • This paper presents a novel CPW-fed UWB monopole paper antenna made by paper and copper tape. Through the simulation, the optimized antenna design parameters were obtained, and an antenna having an omni-directional radiation pattern and a gain of 2.2 dBi or more in the UWB frequency band of 3.1-10.6 GHz was designed. The antenna was manufactured using general A4 paper and copper tape, and the measurement result satisfies the return loss of -10dB or less in the UWB frequency band and confirm that the return loss characteristic was maintained even when the antenna plane was bent by 3 mm in the longitudinal direction. The proposed antenna is a wearable device that can provide services in the UWB band, and can be manufactured inexpensively by printing it with a conductive print on paper. So it can be used as a wearable antenna for UWB communication in various application fields such as logistics and disposable terminals.

A Study on the Motion Control of 3D Printed Fingers (3D 프린팅 손가락 모형의 동작 제어에 관한 연구)

  • Jung, Imjoo;Park, Ye-eun;Choi, Young-Rim;Kim, Jong-Wook;Lee, Sunhee
    • Fashion & Textile Research Journal
    • /
    • v.24 no.3
    • /
    • pp.333-345
    • /
    • 2022
  • This study developed and evaluated the motion control of 3D printed fingers applied to smart gloves. Four motions were programmed by assembling the module using the Arduino program: cylindrical grasping, spherical grasping, tip-to-tip pinch gripping, and three-jaw pinch gripping. Cap and re-entrant (RE) strip types were designed to model the finger. Two types of modeling were printed using filaments of thermoplastic elastomer (TPE) and thermoplastic polyurethane (TPU). The prepared samples were evaluated using three types of pens for cylidrical grasping, three types of balls for spherical grasping, and two types of cards for tip-to-tip pinch gripping and three-jaw pinch gripping. The motion control of fingers was connected using five servo motors to the number of each control board. Cylindrical and spherical grasping were moved by controlling the fingers at 180° and 150°, respectively. Pinch gripping was controlled using a tip-to-tip pinch motion controlled by the thumb at 30° and index-middle at 0° besides a three-jaw pinch motion controlled by the thumb-index finger-middle at 30°, 0°, and 0°, respectively. As a result of the functional evaluation, the TPE of 3D-printed fingers was more flexible than those of TPU. RE strip type of 3D-printed fingers was more suitable for the motion control of fingers than the 3D-printed finger.

The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preload

  • Altuwaijri, Shahad Mohammmed;Alotaibi, Hanan Nejer;Alnassar, Talal Mughaileth
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.22-31
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate the misfit and screw preload at the implant abutment connection of implant supported fixed dental prosthesis with cantilever (ICFDP) manufactured using different digital manufacturing techniques and to compare the screw preload before and after cyclic loading. MATERIALS AND METHODS. Mandibular jaw model with four intra-foraminal implants was scanned using digital scanner. Stereolithography file was used to design a framework with nonengaging (NE) abutments and 10 mm cantilever distal to one terminal implant. Five frameworks were constructed using combined digital-conventional techniques (CAD-cast), and five frameworks were constructed using three-dimensional printing (3DP). Additional CAD-cast framework was constructed in a way that ensures passive fit (PF) to use as control. Scanning electron microscope (SEM) measured the implant abutment connection misfit. Sixty screws were used on the corresponding frameworks. Screws were torqued and pre-cyclic loading reverse torque value (RTV) was recorded. Frameworks were subjected to 200,000 loading cycles with a loading point 9 mm from the center of terminal implants adjacent to the cantilever and post-cyclic loading RTVs were recorded. RESULTS. Microscopic readings showed significant differences between frameworks. PF demonstrated the lowest measurements of 16.04 (2.6) ㎛ while CAD-cast demonstrated the highest measurements of 29.2 (3.1) ㎛. In all groups, RTVs were significantly lower than the applied torque. Post-cyclic loading RTV was significantly lower than pre-cyclic loading RTV in PF and 3DP frameworks. Differences in RTVs between the three manufacturing techniques were insignificant. CONCLUSION. Although CAD-cast and three-dimensionally printed (3DP) both produce frameworks with clinically acceptable misfit, 3DP might not be the technique of choice for maintaining screw's preload stability under an aggressive loading situation.

Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base

  • Park, Se-Jick;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.262-272
    • /
    • 2022
  • PURPOSE. This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment. MATERIALS AND METHODS. Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey's honest significant difference test was used for post-hoc analysis (P < .05). RESULTS. Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS. CONCLUSION. The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.