• Title/Summary/Keyword: Print Circuit Board

Search Result 12, Processing Time 0.018 seconds

Low-k Polymer Composite Ink Applied to Transmission Line (전송선로에 적용한 Low-k 고분자 복합 잉크 개발)

  • Nam, Hyun Jin;Jung, Jae-Woong;Seo, Deokjin;Kim, Jisoo;Ryu, Jong-In;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.2
    • /
    • pp.99-105
    • /
    • 2022
  • As the chip size gets smaller, the width of the electrode line is also fine, and the density of interconnections is increasing. As a result, RC delay is becoming a problem due to the difference in resistance between the capacitor layer and the electrical conductivity layer. To solve this problem, the development of electrodes with high electrical conductivity and dielectric materials with low dielectric constant is required. In this study, we developed low dielectric ink by mixing commercial PSR which protect PCB's circuits from external factors and PI with excellent thermal property and low-k characteristics. As a result, the ink mixture of PSR and PI 10:3 showed the best results, with a dielectric constant of about 2.6 and 2.37 at 20 GHz and 28 GHz, respectively, and dielectric dissipation was measured at about 0.022 and 0.016. In order to verify the applicability of future applications, various line-width transmission lines produced on Teflon were evaluated, and as a result, the loss of transmission lines using low dielectric ink mixed with PI was 0.12 dB less on average in S21 than when only PSR was used.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF