• Title/Summary/Keyword: Primary water environment

Search Result 369, Processing Time 0.03 seconds

Development of Method for In-situ Micro-Scale Observation of Stress Corrosion Cracking in High-Temperature Primary Water Environment (원전 고온 1차수 환경에서 응력부식균열의 실시간 마이크로 스케일 관찰 방법 개발)

  • Jung-Ho Shin;Jong-Yeon Lee;Sung-Woo Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.265-272
    • /
    • 2023
  • The aim of this study was to develop a new in-situ observation method and instrument in micro-scale to investigate the mechanism of stress corrosion cracking (SCC) initiation of Ni-base alloys in a high temperature water environment of pressurized water reactors (PWRs). A laser confocal microscope (LCM), an autoclave with diamond window view port, and a slow strain-rate tester with primary water circulation loop system were components of the instrument. Diamond window, one of the core components of the instrument, was selected based on its optical, chemical, and mechanical properties. LCM was used to observe the specimen in micro-scale, considering the experimental condition of a high-temperature primary water environment. Using in-situ method and instrument, it is possible to observe oxidation and deformation of specimen surface in micro-scale through the diamond window in a high-temperature primary water in real-time. The in-situ method and instrument developed in this work can be utilized to investigate effects of various factors on SCC initiation in a high-temperature water environment.

New test method for real-time measurement of SCC initiation of thin disk specimen in high-temperature primary water environment

  • Geon Woo Jeon;Sung Woo Kim;Dong Jin Kim;Chang Yeol Jeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4481-4490
    • /
    • 2022
  • In this study, a new rupture disk corrosion test (RDCT) method was developed for real-time detection of stress corrosion cracking (SCC) initiation of Alloy 600 in a primary water environment of pressurized water reactors. In the RDCT method, one side of a disk specimen was exposed to a simulated primary water at high temperature and pressure while the other side was maintained at ambient pressure, inducing a dome-shaped deformation and tensile stress on the specimen. When SCC occurs in the primary water environment, it leads to the specimen rupture or water leakage through the specimen, which can be detected in real-time using a pressure gauge. The tensile stress applied to the disk specimen was calculated using a finite element analysis. The tensile stress was calculated to increase as the specimen thickness decreased. The SCC initiation time of the specimen was evaluated by the RDCT method, from which result it was found that the crack initiation time decreased with the decrease of specimen thickness owing to the increase of applied stress. After the SCC initiation test, many cracks were observed on the specimen surface in an intergranular fracture mode, which is a typical characteristic of SCC in the primary water environment.

A Study on the Water Pollutant Discharge Inventories for the Improvement of Industrial Wastewater Management System: Primary Steel Manufacturing Facility and Petroleum Refining Products Manufacturing Facility (산업폐수 관리체계 개선을 위한 수질오염물질 배출목록 구축에 대한 연구: 1차 철강 제조업과 석유정제품 제조업)

  • Ahn, Taeung;Kim, Dongmin;Son, Daehee;Kim, Jaehoon
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.453-467
    • /
    • 2020
  • This study aimed to inventory the water pollutant discharge of wastewater from two facilities, one primary steel manufacturing facility and one petroleum refinery, both of which are located in Korea, and to identify ways to improve the wastewater treatment process through field investigation. Probability evaluation was used to inventory the substances in polluted water. The samples collected in this study included original wastewater, on processing wastewater, and treated water. The general description of wastewater occurrence, major sources, and treatment facilities were also investigated to obtain an integrated database of the pollutants created by different industrial categories. Based on our analysis of raw wastewater and final effluent, the detected pollutants were confirmed by analyzing their presence in the raw or supplemental materials, the potential of formation as byproducts, and the possibility of inclusion as impurities. The compounds detected for each category were screened via investigation of their possible sources and confirmed as the final water pollutant inventories. Thirty kinds of water pollutants were emitted by the primary steel manufacturing facility (reference in case A), including 14 specified hazardous water pollutants. The petroleum refinery (reference in case B) emitted 36 water pollutants, including 16 specified hazardous water pollutants.

Primary Water Stress Corrosion Crack Growth Rate Tests for Base Metal and Weld of Ni-Cr-Fe Alloy (니켈 합금 모재 및 용접재의 일차수응력부식균열 균열성장속도 시험)

  • Lee, Jong Hoon
    • Corrosion Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.33-38
    • /
    • 2019
  • Alloy 600/182 with excellent mechanical/chemical properties have been utilized for nuclear power plants. Although both alloys are known to have superior corrosion resistance, stress corrosion cracking failure has been an issue in primary water environment of nuclear power plants. Therefore, primary water stress corrosion crack (PWSCC) growth rate tests were conducted to investigate crack growth properties of Alloy 600/182. To investigate PWSCC growth rate, test facilities including water chemistry loop, autoclave, and loading system were constructed. In PWSCC crack growth rate tests, half compact-tension specimens were manufactured. These specimens were then placed inside of the autoclave connected to the loop to provide primary water environment. Tested conditions were set at temperature of $360^{\circ}C$ and pressure of 20MPa. Real time crack growth rates of specimens inside the autoclave were measured by Direct Current potential drop (DCPD) method. To confirm inter-granular (IG) crack as a characteristic of PWSCC, fracture surfaces of tested specimens were observed by SEM. Finally, crack growth rate was derived in a specific stress intensity factor (K) range and similarity with overseas database was identified.

Primary Investigation for Evaluation of Abandoned Metal Mine Effect on Yeongsan and Seomjin Watershed (영산강.섬진강 유역 수계 폐금속광산 광해 영향 평가를 위한 개황조사)

  • Choi, Kyoung-Kyoon;Park, Ha-Seung;Oh, Da-Yeon;Kim, Kap-Soon;Huh, Yu-Jeong;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.81-90
    • /
    • 2010
  • In this study, primary investigation for evaluation of abandoned metal mine effect on watershed has been done. 64 abandoned mines have been selected for primary investigation through literature and field survey. 216 soil and 90 water samples were collected and metal pollution concentrations were analyzed. 24 mines have mine water in the pits and acid water below pH 5 was not observed. Soils from 35 mines were over the soil basis of concern and 16 mines were over the soil basis of action. Arsenic average concentration was 188 times of average concentration of the natural background. Drinking water samples from 3 mines were over the drinking water standard and surface water samples from 12 mines were over the river water standard. Integrated pollution index, which was resulted from the integration of field survey, soil and water pollution concentration, showed that, abandoned metal mines had affected on watershed greatly in the order of Samgeum, Daedeok, Cheongdalgeum, Heungsin, Yeongdae and Myeongbong mines.

Introduction of Hydraulic Field Investigation Method to Utilize on the Inhabitation Environment Definition at a River

  • Lee, Hyun-Seok;Kim, Young-Sung;Lee, Geun-Sang;Seo, Jin-Won;Yang, Jae-Rheen;Kwon, Hyung-Joong
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.4
    • /
    • pp.547-553
    • /
    • 2008
  • In recent years, attention on the inhabitation environments of animals and plants which coexist with humans is growing more and more, and relevant research is being activated. In habitats of rivers, a lot of factors are interacting, even among them, some elements especially such hydraulic factors as water velocity and water depth, and such geological shapes as gravels, sand and mud are being considered as primary elements. In this study, various field investigations are carried out to determine the relationship between the river habitats of fishes and hydraulic primary elements using high-tech equipments. Furthermore numerical experiments to classify such habitats according to topographical spaces are carried out. In detail, hydraulic field investigations performed in this study can be summarized as topographical survey, discharge measurement, water level fluctuation monitoring and so on. In numerical experiments, the RMA2 model of the commercial program, Surface-Water Modeling System (SMS), which is widely used in conducting a two-dimensional analysis of the flow behavior of a river is utilized. In conclusion, as a result of field investigation, the relationship between water velocity and water depth is obtained. And the relationship between water velocity and water temperature is identified, too. Finally, using above obtained results, the inhabitation environment was classified into Riffle, Glide, Run, Pool, and E.D.Z according to the relationship between water velocity and water depth.

Differences in Zooplankton Community Structure between Surface Water and Vertical Integrated Water in Middle and Down Stream of Nakdong River (낙동강 중⋅하류에서 표층 시료와 수직 예망 시료의 동물플랑크톤 군집 구조 차이 비교)

  • Min-Seok Kim;Hae-Kyung Park
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.3
    • /
    • pp.215-222
    • /
    • 2023
  • Zooplankton are primary consumers in the food web connecting primary producers and predators such as small fish, playing an important role in energy transfer in aquatic ecosystems. Therefore, it is essential to understand the zooplankton community structure in material cycle and energy flow in aquatic ecosystems. Zooplankton in large rivers with a low flow rate would distribute vertically as in lakes. In this study, we collected zooplankton by surface water filtration and vertical haul method with 64 ㎛-mesh plankton net at three stations (ND-1, ND-2, ND-3) in Nakdong River fortnightly from June 2018 to December 2019. Species composition and individual densities were analyzed. All three stations showed differences in relative abundance of zooplankton groups between surface water and vertical integrated water, with the largest difference shown in the deepest station, ND-2. In vertically integrated water at ND-2, the relative abundance of rotifera was low by a maximum of 25% and that of cladocera was high by a maximum of 22% compared to surface water samples. These results indicate that surface water filtration method is not enough to represent the community structure of zooplankton compared to the vertical haul method in large rivers.

EVALUATION OF GALVANIC CORROSION BEHAVIOR OF SA-508 LOW ALLOY STEEL AND TYPE 309L STAINLESS STEEL CLADDING OF REACTOR PRESSURE VESSEL UNDER SIMULATED PRIMARY WATER ENVIRONMENT

  • Kim, Sung-Woo;Kim, Dong-Jin;Kim, Hong-Pyo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.773-780
    • /
    • 2012
  • The article presented is concerned with an evaluation of the corrosion behavior of SA-508 low alloy steel (LAS) and Type 309L stainless steel (SS) cladding of a reactor pressure vessel under the simulated primary water chemistry of a pressurized water reactor (PWR). The uniform corrosion and galvanic corrosion rates of SA-508 LAS and Type 309L SS were measured in three different control conditions: power operation, shutdown, and power operation followed by shutdown. In all conditions, the dissimilar metal coupling of SA-508 LAS and Type 309L SS exhibited higher corrosion rates than the SA-508 base metal itself due to severe galvanic corrosion near the cladding interface, while the corrosion of Type 309L in the primary water environment was minimal. The galvanic corrosion rate of the SA-508 LAS and Type 309L SS couple measured under the simulated power operation condition was much lower than that measured in the simulated shutdown condition due to the formation of magnetite on the metal surface in a reducing environment. Based on the experimental results, the corrosion rate of SA-508 LAS clad with Type 309L SS was estimated as a function of operating cycle simulated for a typical PWR.

Solubilization of Sewage Sludge by Microwave Pretreatment and Elutriated Acid Fermentation (Microwave를 이용한 하수슬러지의 전처리 특성 및 회분식 세정산발효를 이용한 슬러지 가용화)

  • Lee, Won-Sic;Hong, Seung-Mo;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1130-1136
    • /
    • 2006
  • This work elucidates the effects of pretreatment of the sewage sludge from wastewater treatment plant by microwave irradiation on elutriated acid fermentation. These experiments typically fell into two process; pretreatment as microwave irradiation and elutriated acid fermentation for hydrolysis and acidification as main process of primary sludge. The results of maximum solubilization rate of B, D primary and secondary sludge were 0.042, 0.086 and 0.15 gSCODprod./gICODin and the optimum irradiation time of microwave on 2,450 MHz and 900 W were 5 min. for primary sludge and 7 min. for secondary sludge. From batch tests on elutriated acid fermentation that was used the pretreated primary sludge as microwave, the optimum pH and HRT (hydraulic retention time) were 7 and 5 days at $35^{\circ}C$ condition.

Dynamic Boric Acid Corrosion of Low Alloy Steel for Reactor Pressure Vessel of PWR using Mockup Test (가압형 경수로 압력용기 재료인 저합금강의 동적 붕산 부식 실증 연구)

  • Kim, Sung-Woo;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Corrosion Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2013
  • This work is concerned with an evaluation of dynamic boric acid corrosion (BAC) of low alloy steel for reactor pressure vessel of a pressurized water reactor (PWR). Mockup test method was newly established to investigate dynamic BAC of the low alloy steel under various conditions simulating a primary water leakage incident. The average corrosion rate was measured from the weight loss of the low alloy steel specimen, and the maximum corrosion rate was obtained by the surface profilometry after the mockup test. The corrosion rates increased with the rise of the leakage rate of the primary water containing boric acid, and the presence of oxygen dissolved in the primary water also accelerated the corrosion. From the specimen surface analysis, it was found that typical flow-accelerated corrosion and jet-impingement occurred under two-phase fluid of water droplet and steam environment. The maximum corrosion rate was determined as 5.97 mm/year at the leakage rate of 20 cc/min of the primary water with a saturated content of oxygen within the range of experimental condition of this work.