• Title/Summary/Keyword: Primary pressure

Search Result 1,076, Processing Time 0.036 seconds

A Study on Concrete Lining Stress Changes Considering Load Supporting Capacity of Primary Supports of NATM Tunnel (NATM 터널에서 1차지보재의 지보압을 고려한 콘크리트라이닝 응력변화에 관한 연구)

  • Jeon, Sang Hyun;Shin, Young Wan;Yoo, Han Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4C
    • /
    • pp.147-154
    • /
    • 2011
  • Currently NATM tunnels are designed by applying the initial ground loads caused during construction to the primary supports, conisting of shotcrete, steel ribs and rock bolts. For long term considerations, it is assumed that the primary supports lose its functionality and therefore the secondary support, i.e. concrete lining, is design to resist against the entire ground loads. But the steel ribs, usually applied to bad ground conditions, are embedded in shotcrete causing very little corrosion and therefore the assumption that the primary support will lose all of its functionality is too conservative. Also even though shotcrete carbonates in long term, excluding it from design is also too conservative. In this study, we have, through analytical and numerical analysis, set a rational level of support pressure and allowable relaxed rock mass height sustainable by the primary support for long term design. Changes in sectional forces of the concrete lining considering the calculated support pressure of the primary supports was also carried out. Shallow subway tunnels were considered in the analysis with weathered rock and soft rock ground conditions. The analysis results showed that, by considering the support pressure of steel ribs, an economical design of the concrete lining is possible.

Study of Supersonic, Dual, Coaxial, Swirl Jet (초음속 동축 스월제트의 유동특성에 대한 연구)

  • 김중배;이준희;이권희;김희동
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.15-18
    • /
    • 2003
  • The present study addresses an experimental investigations of the near field flow structures of supersonic, dual, coaxial, swirl jet. The swirl stream is discharged from the secondary annular nozzle and the primary inner nozzle provides the sonic and supersonic free jets. The interactions between the secondary swirl and inner soni $c^ersonic jets are quantified by a fine pilot impact and static pressure measurements and are visualized by using a shadowgraph optical method. The pressure ratios of the secondary swirl and primary soni $c^ersonic jets are varied below 7.0. Experiments are conducted to investigate the effects of the secondary swirl stream on the primary sonic and supersonic jets, compared with the secondary stream of no swirl. The results show that the presence of annular swirl stream causes the Mach disk to move more downstream, with the increased diameter, and remarkably reduces the fluctuations of the impact pressures in the supersonic dual coaxial jet, compared with the case of the secondary annular stream of no swirl.swirl.

  • PDF

EVALUATION OF GALVANIC CORROSION BEHAVIOR OF SA-508 LOW ALLOY STEEL AND TYPE 309L STAINLESS STEEL CLADDING OF REACTOR PRESSURE VESSEL UNDER SIMULATED PRIMARY WATER ENVIRONMENT

  • Kim, Sung-Woo;Kim, Dong-Jin;Kim, Hong-Pyo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.773-780
    • /
    • 2012
  • The article presented is concerned with an evaluation of the corrosion behavior of SA-508 low alloy steel (LAS) and Type 309L stainless steel (SS) cladding of a reactor pressure vessel under the simulated primary water chemistry of a pressurized water reactor (PWR). The uniform corrosion and galvanic corrosion rates of SA-508 LAS and Type 309L SS were measured in three different control conditions: power operation, shutdown, and power operation followed by shutdown. In all conditions, the dissimilar metal coupling of SA-508 LAS and Type 309L SS exhibited higher corrosion rates than the SA-508 base metal itself due to severe galvanic corrosion near the cladding interface, while the corrosion of Type 309L in the primary water environment was minimal. The galvanic corrosion rate of the SA-508 LAS and Type 309L SS couple measured under the simulated power operation condition was much lower than that measured in the simulated shutdown condition due to the formation of magnetite on the metal surface in a reducing environment. Based on the experimental results, the corrosion rate of SA-508 LAS clad with Type 309L SS was estimated as a function of operating cycle simulated for a typical PWR.

An Experimental Study of the Subsonic/Supersonic Steam Ejectors (아음속/초음속 증기 이젝터에 관한 실험적 연구)

  • 최보규;김희동;이준희;김덕줄
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.1-8
    • /
    • 2000
  • For the purpose of a cost effective design of practical subsoni $c^ersonic ejector systems, an experiment was carried out using a superheated steam as a primary driving flow. The superheated steam jet was produced by several different kinds of subsonic and supersonic nozzles. The secondary flow of atmospheric air inside a plenum chamber was drawn into the primary steam jet. The vacuum performance of the plenum chamber was investigated for a wide range of the ejector operation pressure ratio. The result showed that the static pressure of the mixed flow at the ejector throat is only a function of the ejector operation pressure ratio, regardless of the primary nozzle type employed.ed.

  • PDF

A Nested Case-Control Study on the High Normal Blood Pressure as a Risk Factor of Hypertension in Korean Middle-aged Men (중년 남성에서 고정상혈압에 의한 고혈압발생 위험 규명을 위한 코호트내 환자-대조군 연구)

  • Ahn, Yoon-Ok;Bae, Jong-Myon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.4
    • /
    • pp.513-525
    • /
    • 1999
  • Objectives : High-normal blood pressure' is a factor influencing decision to initiate targeted intensive intervention strategy in westernized populations. JNC-VI offered the vigorous lifestyle modification for persons with 'high-normal blood pressure', who could be early detected. As a hypertension seems to be the result of multiple genetic factors operating in concert with associated environmental factors, it will be necessary to identify the high-normal blood pressure as a risk factor of hypertension for applying primary prevention strategy in Korean people. Methods : Although cohort study design might be adequate to recruit incidence cases, to keep time sequence of events, and to prevent information bias, nested case-control study was chosen for avoiding measurement errors because hypertension is a benign disease. Source population was the 'Seoul Cohort' participants and follow-up was done by using Korea Medical Insurance Corporation's database on the utilization of health services from 1 Jan93 to 30Jun97. Incidence cases were ascertained through the chart review, telephone contacts, and direct blood pressure measurements. Controls included the pairing of 4 individuals to each case on the basis of age. Results : As 75% of 247 incident cases had high-normal blood pressure, the crude odds ratio for hypertension was 2.04 (95% CI 1.47-2.83). Another statistically significant risk factors of hypertension were body mass index, dietary fiber, alcohol consumption, weekly activity and history of quitting smoking. The multivariate odds ratio of high-normal blood pressure adjusted for all risk factors was 1.84 (95% CI 1.31-2.56). Among high-normal blood pressure group, body mass index, weekly ethanol amounts, weekly physical activity, and dietary fiber except history of quitting smoking were still risk factors of hypertension. Conclusion : 'High-normal blood pressure' is a risk factor for hypertension in Korean middle-aged men, which represents that the vigorous lifestyle modification for persons with 'high-normal blood pressure' is need.

  • PDF

Stress Analysis and Evaluation of Steam Separator of Heat Recovery Steam Generator (HRSG) (배열회수보일러 기수분리기의 응력해석 및 평가)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.23-31
    • /
    • 2018
  • Stress of a steam separator, equipment of the high-pressure (HP) evaporator for a HRSG, was analyzed and evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the analysis results of the piping system model of the HP evaporator, reaction forces of the riser tubes connected to the steam separator, i.e., nozzle loads, were derived. Next, a finite element model of the steam separator was constructed and analyzed for the design pressure and the nozzle loads. The results show that the maximum stress occurred at the bore of the riser nozzle. The primary membrane stresses at the shell and nozzle were found to be less than the allowable stress. Next, the steam separator was analyzed for the steady-state operating conditions of operating pressure, operating temperature, and nozzle loads. The maximum stress occurred at the bore of the riser nozzle. The primary plus secondary membrane plus bending stress at the shell and nozzle was found to be less than the allowable stress.

The Treatment of Trochanteric Pressure Sore Using Superior or Inferior Gluteal Artery Perforator Flap (상.하둔동맥 천공지피판을 이용한 대전자부 욕창의 치료)

  • Tark, Woo-Hyun;Lee, Won-Jai;Yun, In-Sik;Rah, Dong-Kyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.235-240
    • /
    • 2011
  • Purpose: Management of pressure sores has been improved, along with development of musculocutaneous flaps and perforator flaps. Nowadays, the treatment of pressure sore with perforator flaps has shown several advantages, including minimal donor site morbidity, relatively versatile flap design not only in primary cases but also in recurred cases and minimized anatomical rearrangement of regional muscle position. In this study, we report our clinical experience of gluteal perforator flap used in the treatment of a greater trochanteric pressure sore. Methods: A clinical study was performed on 7 patients who underwent total 10 operations. 1 superior gluteal artery perforator flap and 9 inferior gluteal artery perforator flaps were used to reconstruct the defect, followed by the mean observation duration of 22 months. Results: There were no total flap loss. We treated 2 cases of partial flap loss with debridement and primary repair. 2 recurred cases were successfully treated using the same method. Donor sites were all primarily repaired. Conclusion: The gluteal perforator flap could be considered as a safe and favorable alternative in the treatment of soft tissue defects in the greater trochanteric area. The advantages of the flap include low donor site morbidity and the possibility of versatile flap design not only in primary cases but also in recurred cases.

The Experimental Study of Supersonic, Dual, Coaxial, Free, Jets (환형동축 초음속 자유 제트유동에 관한 실험적 연구)

  • Lee, K.H.;Lee, J.H.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.323-328
    • /
    • 2001
  • Supersonic coaxial, axisymmetric, jets issuing from various kinds of dual coaxial nozzles were experimentally investigated. Four different kinds of coaxial, dual nozzles were employed to characterize the major features of the supersonic, coaxial, dual jets. Two convergent-divergent supersonic nozzles with an impinging angle in the jet axis of the annular jets were designed to have the Mach number 2.0 and used to compare the coaxial jet flows with those discharging from two sonic nozzles. The primary pressure ratio was changed in the range from 4.0 to 10.0 and the assistant jet ratio from 1.0 to 4.0. The results obtained show that the assistant jets from the annular nozzle affect the coaxial jet flows and an increase of both the primary jet pressure ratio and assistant jet pressure ratio produces longer supersonic length of the dual, coaxial jet.

  • PDF

Design and Test of ASME Strainer for Coolant System of Research Reactor (연구용 원자로 냉각계통의 ASME 스트레이너 설계 및 성능시험)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.24-29
    • /
    • 1999
  • The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, Class 3 and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference.

  • PDF

Calculation of Equivalent Feeder Geometries for CANDU Transient Simulations

  • Cho, Seungyon;Muzumdar, Ajit
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.429-436
    • /
    • 1995
  • This paper describes a methodology for determination of representative CANDU feeder geometry and the pressure drops between inlet/outlet header and fuel channel in the primary loop. A code, MEDOC, was developed based on this methodology and helps perform a calculation of equivalent feeder geometry for a selected channel group on the basis of feeder geometry data (fluid volume, mass flow rate, loss factor) and given property data pressure, quality, density) at inlet/outlet header. The equivalent feeder geometry calculated based on this methodology will be useful fur the transient thermohydraulic analysis of the primary heat transport system for the CANDU heavy water-cooled pressure tube reactor.

  • PDF