• Title/Summary/Keyword: Primary frequency control

Search Result 260, Processing Time 0.026 seconds

FREQUENCY-TEMPERATURE CHARACTERISTIC ANALYSIS OF PIEZOELECTRIC RESONATORS USING FINITE ELEMENT MODELING

  • Wakatsuki, N.;Tsuchiya, T.;Kagawa, Y.;Suzuki, K.
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.215-219
    • /
    • 2001
  • The resonators made of piezoelectric crystals such as a quartz crystal are widely used. Their frequency-temperature characteristics are of primary importance for their applications to the frequency control devices. The characteristics estimation is useful for determining their design parameters. In the present paper, several types of resonators are numerically analyzed. The numerical solutions are made using 3-D Finite Element Modeling, and the results are compared with the theoretical values whenever they are available. To demonstrate the validity of the present numerical approach, the application is made to the analysis of the plates with some well-established cutting angles. For the resonator stable with temperature change, the cutting angle is important in which the temperature coefficient of the first order is chosen to be zero. The rotated Y-cut plates in thickness-shear mode are considered. The equivalent circuit representation is often used fur describing the characteristics at the electrical terminals which enables the circuit analysis including the effect of temperature change by using the circuit simulators. The equivalent circuit parameters are obtained by fitting the admittance-frequency curve from the finite element analysis.

  • PDF

The Ballast for HID Lamps of Preventing the Overvoltage with a Long Distance Resonant Ignition (원거리 공진 기동시 과전압 방지 HID 안정기)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.94-102
    • /
    • 2015
  • The electronic ballast for HID lamps needs to ignite lamps even though the length from the ballast to lamp is far away. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps because the reduction of ignition voltage is not much depending on the distance. However, the parasitic capacitance is increased depending the length of the cable, and it affects the resonant frequency. The ignitor voltage can be increased drastically under the resonant ignition through frequency sweep, and it is the main reason of blowing up. Therefore, the clamping diode is proposed to suppress the voltage of the primary winding during resonant ignition.

A Study on the Automatic Diagnosis of ECG

  • Jeong, Gu-Young;Yu, Kee-Ho;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.55.4-55
    • /
    • 2001
  • Analyzing the ECG signal, we can find heart disease. Myocardial ischemia is a disorder of cardiac function caused by insufficient blood flow to the muscle tissue of the heart. Myocardial ischemia is inscribed on ST-segment of the ECG during and after patient takes exercise or is under stress, but after long time past, the ECG pattern is return to steady state. Therefore, it is necessary to monitor and analyze the ECG signal continuously for patient or aged people. Our primary purpose is the detection of temporary change of the ST-segment of ECG automatically. In the signal processing, the wavelet transform decomposes the ECG signal into high and low frequency components using wavelet function. Recomposing the high frequency bands including QRS complex, we can detect QRS complex more easily ...

  • PDF

On Characteristics of Surface Ozone Concentration and Important Meteorological Parameters in Pusan, Korea (부산 지역의 오존 농도 특징과 기상 인자에 관한 연구)

  • 전병일;김유근;이화운
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.45-56
    • /
    • 1995
  • We considered that characteristics of surface ozone continuous and important meteorological parameters from the data measured 7 air quality continuous monitoring stations during 2 years (1990, 1993) in pusan. The diurnal ozone variation showed a primary peak near 1500LST and a secondary peak of the DP(double peaked) pattern. The episode day was defined when an ozone peak higher than 60 ppb was observed at least one station. The frequency of episode day was 100 (298 hours, 69 days). The frequency of the episode day was higher at Meongryundong and Daeyeondong than other sites and highest in August under control of pacific subtropical high. The high temporatant meteorological parameters accompanying the high episode days. The favorable synoptic environment accompanying ozone episode was distributed to 7 different pattern. These pattern can be taken as a nesessary but not an absolute indicator for predicting the occerrence of an episode.

  • PDF

The study of frequency characteristic of Interference Device on the noise barrier edge for reduction of Traffic noise (도로교통소음저감을 위한 간섭장치 주파수특성에 관한 연구)

  • 장강석;윤제원;김영찬;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.134-139
    • /
    • 2002
  • We have made known the study of shape development of interference device for vehicle noise control. It's primary object greatly attenuate the noise due to transport vehicle by small products installed on the noise barrier edge. Also, it is able to improve the insertion loss of a noise barrier without increasing the height. The present time, we set up a newly manufactured products on the noise barrier edge and testify to it's the performance make use of an experiment and evaluation for the reduction of highway traffic noise. In this paper the frequency characteristic of interference device of noise barriers with attached newly developed products in terms of shape, absorptive material and split panel, are examined using field test at highway.

  • PDF

Speed Sensorless Control of Induction Motors in the Very tow Speed Region Considering the Secondary Resistance Identification (2차저항 동정을 고려한 유도전동기의 저속영역 속도센서리스 제어)

  • 황동일;이진국;정석권
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • The speed control without a speed sensor is expected strongly to progress reliability, simplicity and cost performance of Induction Motor(I.M) systems. Also, it contributes to expansion of I.M systems into various industrial application fields. This paper investigates a novel speed sensorless control method of I.M considering the secondary resistance identification based on the transientless torque control technique. Especially, this paper aimed at the identification of the secondary resistance simultaneously with speed estimation superposing of sinusoidal flux wave to a constant flux value. Furthermore, the secondary flux with some frequency is controlled independently on torque control. The proposed speed estimation method is derived from a motor circuit equation theoretically and also it can be conducted easily by detecting primary motor currents and primary voltage commands at every sampling time. Some numerical simulations with the assumption of using a pulse width modulation(PWM) voltage source inverter are performed to verify the proposed method.

  • PDF

Heading Control of a Turret Moored Offshore Structure Using Resolved Motion and Acceleration Control

  • Kim, Young-Shik;Sung, Hong-Gun;Kim, Jin-Ha
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.1
    • /
    • pp.16-24
    • /
    • 2018
  • This paper addresses the heading control of an offshore floating storage and regasification unit (FSRU) using a resolved motion and acceleration control (RMAC) algorithm. A turret moored vessel tends to have the slewing motion. This slewing motion may cause a considerable decrease in working time in loading and unloading operation because the sloshing in the LNG containment tank might happen and/or the collision between FSRU and LNGC may take place. In order to deal with the downtime problem due to this slewing motion, a heading control system for the turret moored FSRU is developed, and a series of model tests with azimuth thrusters on the FSRU is conducted. A Kalman filter is applied to estimate the low-frequency motion of the vessel. The RMAC algorithm is employed as a primary heading control method and modified I-controller is introduced to reduce the steady-state errors of the heading of the FSRU.

Spatial Manipulation of Sound using Multiple Sources (다수의 음원을 사용한 공간의 소리 제어 방법론)

  • Choi, Joung-Woo;Kim, Yang-Hann;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.620-628
    • /
    • 2005
  • Spatial control of sound is essential to deliver better sound to the listener's position in space. As it can be experienced in many listening environments, the quality of sound can not be manifested over every position in a hall. This motivates us to control sound in a region we select. The primary focus of the developed method has to do with the brightness and contrast of acoustic image in space. In particular, the acoustic brightness control seeks a way to increase loudness of sound over a chosen area, and the contrast control aims to enhance loudness difference between two neighboring regions. This enables us to make two different kinds of zone - the zone of quiet and the zone of loud sound - at the same time. The other perspective of this study is on the direction of sound. It is shown that we can control the direction of perceived sound source by focusing acoustic energy in wavenumber domain. To begin with, the proposed approaches are formulated for pure-tone case. Then the control methods are extended to a more general case, where the excitation signal has broadband spectrum. In order to control the broadband signal in time domain, an inverse filter design problem is defined and solved in frequency domain. Numerical and experimental results obtained in various conditions certainly validate that the acoustic brightness, acoustic contrast, direction of wave front can be manipulated for some finite region in space and time.

  • PDF

Experimental investigation on multi-mode vortex-induced vibration control of stay cable installed with pounding tuned mass dampers

  • Liu, Min;Yang, Wenhan;Chen, Wenli;Li, Hui
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.579-587
    • /
    • 2019
  • In this paper, pounding tuned mass dampers (PTMDs) were designed to mitigate the multi-mode vortex-induced vibration (VIV) of stay cable utilizing the viscous-elastic material's energy-dissipated ability. The PTMD device consists of a cantilever metal rod beam, a metal mass block and a specially designed damping element covered with viscous-elastic material layer. Wind-tunnel experiment on VIV of stay cable model was set up to validate the effectiveness of the PTMD on multi-mode VIV mitigation of stay cable. By analyzing and comparing testing results of all testing cases, it could be verified that the PTMD with viscous-elastic pounding boundary can obviously mitigate the VIV amplitude of the stay cable. Moreover, the installed location and the design parameters of the PTMD device based on the controlled modes of the primary stay cable, would have a certain extent suppression on the other modal vibration of the stay cable, which means that the designed PTMDs are effective among a large band of frequency for the multi-mode VIV control of the stay cable.

Change of RIII Reflex of Primary and Secondary Hyperalgesia Site by High Voltage Pulsed Current (고전압맥동전류에 의한 일차 및 이차통각과민대의 RIII 반사의 변화)

  • Kim, Su-Hyon;Choi, Sug-Ju;Lee, Jung-Woo;Jeong, Jin-Gyu;Kim, Tae-Youl;Kim, Gye-Yeop
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • This study conducted RIII reflex measurement to examine degree of pain depending on polarity of high voltage pulsed current of primary and secondary hyperalgesia site in hyperalgesia rat by local thermal injury. Hind paw which was injury site was taken as primary hyperalgeisa site, sole which was injury adjacent site was taken as secondary hyperalgesia site, and mechanical pain threshold, thermal pain threshold and root mean square of RIII reflex were measured. This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal high voltage treatment group II, anodal high voltage treatment group III and alternate high voltage treatment group IV, applied active electrode of high voltage pulsed current to hind paw directly, placed reference electrode on the sole of injury adjacent site and applied pulse frequency. It measured RIII reflex and obtained the following results: Root mean square of RIII reflex at primary hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group II showed significant decrease after 5 and 6 days of hyperalgesia. Root mean square of RIII reflex at secondary hyperalgesia site showed significant reduction in group II after 6 days of hyperalgesia. Consequently it was found that application of high voltage pulsed current of hyperalgesia site reduced RIII reflex at primary hyperalgeisa site and secondary hyperalgesia site by electrical stimuli. Effects by polarity of high voltage pulsed current showed the greatest reduction of pain threshold when cathodal active electrode was used.

  • PDF