• Title/Summary/Keyword: Primary control

Search Result 3,244, Processing Time 0.036 seconds

Object Replication and Consistency Control Techniques of P2P Structures for Multiplayer Online Games (멀티플레이어 온라인 게임을 위한 P2P 구조의 객체 복제와 일관성 제어 기법)

  • Kim, Jinhwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.91-99
    • /
    • 2014
  • The main game architectures for multiplayer online games are the traditional client-server architectures, multi-server architectures and P2P(peer-to-peer) architectures. P2P architectures, due to their distributed and collaborative nature, have low infrastructure costs and can achieve high scalability as well as fast response time by creating direct connections between players. However, P2P architectures face many challenges. Distributing a game among peers makes maintaining control over the game more complex. These architectures also tend to be vulnerable to churn and cheating. Providing consistency control in P2P systems is also more difficult since conflicting updates might be executed at different sites resulting in inconsistency. In order to avoid or correct inconsistencies, most multiplayer games use a primary-copy replication approach where any update to the object has to be first performed on the primary copy. This paper presents the primary-copy model with the update dissemination mechanism that provides consistency control over an object in P2P architectures for multiplayer online games. The performance for this model is evaluated through simulation experiments and analysis.

Can Granisetron Injection Used as Primary Prophylaxis Improve the Control of Nausea and Vomiting with Low-Emetogenic Chemotherapy?

  • Keat, Chan Huan;Phua, Gillian;Kassim, Mohd Shainol Abdul;Poh, Wong Kar;Sriraman, Malathi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.469-473
    • /
    • 2013
  • Background: The purpose of this study is to examine the risk of uncontrolled chemotherapy-induced nausea and vomiting (CINV) among patients receiving low emetogenic chemotherapy (LEC) with and without granisetron injection as the primary prophylaxis in addition to dexamethasone and metochlopramide. Materials and Methods: This was a single-centre, prospective cohort study. A total of 96 patients receiving LEC (52 with and 42 without granisetron) were randomly selected from the full patient list generated using the e-Hospital Information System (e-His). The rates of complete control (no CINV from days 1 to 5) and complete response (no nausea or vomiting in both acute and delayed phases) were identified through patient diaries which were adapted from the MASCC Antiemesis Tool (MAT). Selected covariates including gender, age, active alcohol consumption, morning sickness and previous chemotherapy history were controlled using the multiple logistic regression analyses. Results: Both groups showed significant difference with LEC regimens (p<0.001). No differences were found in age, gender, ethnic group and other baseline characteristics. The granisetron group indicated a higher complete response rate in acute emesis (adjusted OR: 0.1; 95%CI 0.02-0.85; p=0.034) than did the non-granisetron group. Both groups showed similar complete control and complete response rates for acute nausea, delayed nausea and delayed emesis. Conclusions: Granisetron injection used as the primary prophylaxis in LEC demonstrated limited roles in CINV control. Optimization of the guideline-recommended antiemetic regimens may serve as a less costly alternative to protect patients from uncontrolled acute emesis.

Power Control and DFS Based on Genetic Algorithm in Cognitive Radio System (Cognitive Radio 시스템에서 유전자 알고리즘 기반 전력 제어 및 동적 주파수 선택방법)

  • Lee, Joo-Kwan;Shan, Sung-Hwan;Hong, In;Kim, Jae-Moung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.3
    • /
    • pp.100-111
    • /
    • 2009
  • Cognitive radio is an advanced technology for efficient utilization of under-utilized spectrum via spectrum sensing. CR users should move from current allocating channel to empty channel to avoid the interference to the primary user if the primary user is allocating that channel. Thus, CR system cannot support the CR user's QoS(Quaiity of Service). In this paper, we propose dynamic frequency selection method based on Genetic Algorithm with power control. It is to find the optimization channel for satisfying various CR user's needs with the power control method to minimize the CR user's interference to the primary user. And, we propose the Genetic Algorithm(GA) which determines the best configuration for CR communication systems. The computer simulation results show that the proposed method guaranteed the primary user's decodability and the optimized solution for various channel status.

  • PDF

Effect of Auricular Acupuncture on Nonsteroidal Antiinflammatory Drug Dose in Primary Dysmenorrhea : A Randomized Controlled Trials (비스테로이드성 소염진통제를 복용하는 원발성 월경곤란증 환자에 대한 이침치료의 무작위대조군임상시험)

  • Hur, Da-Hee;Kang, So-Hyeon;Kwon, Han-Seul;Ahn, Ha-Young;Baek, Hyung-Chan;Kim, Hyeong-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.35 no.4
    • /
    • pp.161-173
    • /
    • 2022
  • Objectives: This study was conducted to evaluate the effectiveness of acupuncture in patients with primary menstrual difficulties taking NSAIDs. Methods: 30 women with primary menstrual difficulties with NSAIDs were assigned to treatment groups (n=15) and control groups (n=15). On their first visit, both groups were provided with a menstrual diary and were required to record the intensity of pain and the dosage of painkillers during each menstrual cycle. The treatment group received two acupuncture treatments per cycle during two cycles, and the control group did not receive acupuncture. Pain strength during menstruation was evaluated using Visual Analogue Scale (VAS), and the total number of painkillers taken during menstruation and the average number of painkillers taken during a single dose was measured. Results: The treatment group had significant pain relief compared to the pre-test group and significant differences from the control group. In addition, there was a significant difference between the treatment group and the control group in the frequency of taking painkillers during the menstrual period and the dose in the test group was significantly lower than before treatment. Conclusions: This clinical trial showed that this acupuncture can help alleviate primary menstruation and reduce the use of nonsteroidal anti-inflammatory drugs.

Transcutaneous Energy Transmission with Double Tuned Duty Cycle Control (양단 공진과 듀티 컨트롤을 이용한 1-2cm 공극을 통한 에너지 전달)

  • Kim, Chang-Gyun;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.486-488
    • /
    • 1996
  • A dc-dc converter which transfers l2-48W of power(regulated output voltage 24V) across a large, variable air gap(1-2cm) has been designed. This converter employs double resonance to compensate the large leakage inductance of the primary and secondary of the transcutaneous transformer. To maximize the effect of resonance, a constant frequency, duty cycle control method is used. The duty cycle control presents advantages over a frequency control in terms of increase in dc voltage gain and reduction of the primary current. The analysis and design procedure for the proposed scheme is presented and the performance result is simulated and verified experimentally.

  • PDF

Bi-Directional Wireless Power Transfer for Vehicle-to-Grid Systems

  • Sun, Yue;Jiang, Cheng;Wang, Zhihui;Xiang, Lijuan;Zhang, Huan
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1190-1200
    • /
    • 2018
  • A current sourced bi-directional wireless power transfer (WPT) system is proposed to solve the problems that exist in the bi-directional WPT for vehicle-to-grid (V2G) systems. These problems include the fact that these systems are not safe enough, the output power is limited and the control methods are complicated. Firstly, the proposed system adopts two different compensation and control methods on both the primary and secondary sides. Secondly, based on an AC impedance analysis, the working principle is analyzed and the parameter configuration method with frequency stability is given. In order to output a constant voltage, a bi-directional DC/DC circuit and a controllable rectifier bridge are adopted, which are based on the "constant primary current, constant secondary voltage" control strategy. Finally, the effectiveness and feasibility of the proposed methods are verified by experimental results.

Stabilization of Elevation for Gunner Primary Sight Using Variable Structure Control (가변구조제어에 의한 조준경 고각 안정화)

  • 허남수;이정규;김주상;김중완;이만형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1649-1656
    • /
    • 1991
  • 본 연구에서는 가변구조제어에 의한 조준경 고각 안정화를 모색하였다. 이 를 위해 조준경 고각 안정화 시스템의 운동 방정식을 이용하여 가변구조제어기를 설계 하였으며 방정식을 이용하여 가변구조제어기를 설계하였으며 실제 주행시험결과 측정 된 차량의 각속도를 외란으로 사용하여 컴퓨터 시뮬레이션하여 가변구조제어에 의한 조준경 고각 안정화가 동적안정도를 충족시킴을 보였다.

Speed Sensorless Control of Induction Motors in the Very Low Speed Region Considering the Secondary Resistance Identification using Flux Signal (자속정보를 이용한 2차저항 동정기능을 갖는 유도전동기의 저속영역 속도센서리스 제어)

  • Lee, Z.G.;Jeong, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.308-310
    • /
    • 2001
  • This paper investigates a novel speed sensorless control method of I.M considering the secondary resistance identification based on the transientless torque control technique. Especially, this paper aimed at the identification of the secondary resistance simultaneously with speed estimation superposing of sinusoidal flux wave to a constant flux value. Furthermore, the secondary flux with some frequency is controlled independently on torque control. The proposed speed estimation method is derived from a motor circuit equation theoretically and also it can be conducted easily by detecting primary motor currents and primary voltage commands at every sampling time. Some numerical simulations with the assumption of using a pulse width modulation(PWM) voltage source inverter are performed to verify the proposed method.

  • PDF

A Study of Flow Control in a Combustion Chamber (연소실내의 유동제어에 관한 연구)

  • 김정훈
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.86-92
    • /
    • 2000
  • Two-phase flow in a combustion chamber is experimentally analyzed according to the five different conditions in the Reynolds number of $1.02{\times} 10^4$ As the height difference between the primary and secondary jets increases the secondary has a little effect on the primary. In the case of the same height difference the primary jet is affected as the velocity of secondary increases. The primary-jet flow field causes the particle concentration since the particle stagnation phenomena appear in the recirculation zone. The particle concentration is controlled by the velocity of secondary jet the height difference and the angle of primary jet in the test section.

  • PDF