• Title/Summary/Keyword: Primary beam

Search Result 390, Processing Time 0.025 seconds

Applications of Ar Gas Cluster Ion Beam Sputtering to Ta2O5 thin films on SiO2/Si (100)

  • Park, Chanae;Chae, HongChol;Kang, Hee Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.119-119
    • /
    • 2015
  • Ion beam sputtering has been widely used in Secondary Ion Mass Spectrometry (SIMS), X-ray Photoelectron Spectroscopy (XPS), and Auger Electron Spectroscopy (AES) for depth profile or surface cleaning. However, mainly due to severe matrix effects such as surface composition change from its original composition and damage of the surface generated by ion beam bombardment, conventional sputtering skills using mono-atomic primary ions with energy ranging from a few hundred to a thousand volts are not sufficient for the practical surface analysis of next-generation organic/inorganic device materials characterization. Therefore, minimization of the surface matrix effects caused by the ion beam sputtering is one of the key factors in surface analysis. In this work, the electronic structure of a $Ta_2O_5$ thin film on $SiO_2/Si$ (100) after Ar Gas Cluster Ion Beam (GCIB) sputtering was investigated using X-ray photoemission spectroscopy and compared with those obtained via mono-atomic Ar ion beam sputtering. The Ar ion sputtering had a great deal of influence on the electronic structure of the oxide thin film. Ar GCIB sputtering without sample rotation also affected the electronic structure of the oxide thin film. However, Ar GCIB sputtering during sample rotation did not exhibit any significant transition of the electronic structure of the $Ta_2O_5$ thin films. Our results showed that Ar GCIB can be useful for potential applications of oxide materials with sample rotation.

  • PDF

Measurement of Dose Distribution in Small Beams of Philips 6 and 8 MVX Linear Accelerator (Philips LINAC 6 MV와 8 MV X선 소조사연에 대한 선량분포 측정)

  • Suh Tae-suk;Yoon Sei Chul;Shinn Kyung Sub;Park Yong Whee
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.143-152
    • /
    • 1991
  • The work suggested in this paper addresses a method for collecting beam data for small circular fields. Beam data were obtained from philips 6 and 8 MV LINAC at Dept. Radiation Therapy at Gainesville Incorporated and Shands Teaching Hospital. Specific quantities measured include tissue maximum ratio (TMR), off-axis ratio (OAR) and relative output factor (ROF) In small field irradiation, special collimators were used to produce circular fields of 1 cm to 3 cm diameter in 2 mm steps, measured at SAO (soura axis distance) of 100 cm. Diode detector was chosen for primary beam measurement and compared with measurements made with photographic film and TLD dosimeters. The measured TMRs and OARs were formulated from limited measurements to generate basic beam data for reference set-up. The empirical formula were later, extended and generalized for any possible set-up using the trends of fitting parameters. The measured TMRs and OARs were well represented by the fitting formula developed.

  • PDF

Thermal post-buckling and primary resonance of porous functionally graded beams: Effect of elastic foundations and geometric imperfection

  • Jia-Qin Xu;Gui-Lin She
    • Computers and Concrete
    • /
    • v.32 no.6
    • /
    • pp.543-551
    • /
    • 2023
  • In this article, thermal post-buckling and primary resonance of the porous functionally graded material (FGM) beams in thermal environment considering the geometric imperfection are studied, the material properties of FGM beams are assumed to vary along the thickness of the beam, meanwhile, the porosity volume fraction, geometric imperfection, temperature, and the elastic foundation are considered, using the Euler-Lagrange equation, the nonlinear vibration equations are derived, after the dimensionless processing, the dimensionless equations of motion can be obtained. Then, the two-step perturbation method is applied to solve the vibration problems, the resonance and thermal post-buckling response relations are obtained. Finally, the functionally graded index, the porosity volume fraction, temperature, geometric imperfection, and the elastic foundation on the resonance behaviors of the FGM beams are presented. It can be found that these parameters can influence the thermal post-buckling and primary resonance problems.

Analysis of Heat Generation Induced by Electron Impact in X-Ray Tube Using FEM and Monte Carlo Method (유한요소법과 몬테카를로법을 이용한 X선 튜브에서 전자빔 충격에 의한 열 발생 해석)

  • Kim, Heungbae;Yoo, Tae Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.4
    • /
    • pp.387-394
    • /
    • 2015
  • We analyze heat generation as well as temperature distribution induced by accelerated electron impact on a target in a closed x-ray tube. For the sake of accuracy, we use Monte carlo analysis. This method gives accurate energy deposit in a medium with additional information such as secondary and backscattered electron as well as their paths. A Tungsten coated layer is divided by small rectangular cell which accumulate energy loss of primary electron beam. The cells and their accumulated energy datum are used for the input of finite element analysis. The Maximum temperature rising and temperature distribution were analyzed by transient heat analysis. Some temperature parameters such as target size and coating thickness were varied to investigate temperature sensitivity. Temperatures were compared each other to find primary variable that affect temperature rising on the x-ray target. The results will be helpful in development highresolution x-ray tube and related industries.

Structural performance of cold-formed steel composite beams

  • Dar, M. Adil;Subramanian, N.;Anbarasu, M.;Dar, A.R.;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • v.27 no.5
    • /
    • pp.545-554
    • /
    • 2018
  • This study presents a novel method of improving the strength and stiffness of cold-formed steel (CFS) beams. Flexural members are primary members in most of the structures. Hence, there is an urgent need in the CFS industry to look beyond the conventional CFS beam sections and develop novel techniques to address the severe local buckling problems that exist in CFS flexural members. The primary objective of this study was to develop new CFS composite beam sections with improved structural performance and economy. This paper presents an experimental study conducted on different CFS composite beams with simply supported end conditions under four point loading. Material properties and geometric imperfections of the models were measured. The test strengths of the models are compared with the design strengths predicted by using Australian/New Zealand Standard for cold-formed steel structures. Furthermore, to ensure high precision testing, a special testing rig was also developed for testing of long span beams. The description of test models, testing rig features and test results are presented here. For better interpretation of results, a comparison of the test results with a hot rolled section is also presented. The test results have shown that the proposed CFS composite beams are promising both in terms of better structural performance as well as economy.

SIMS glancing anlge을 적용한 tunnel oxide 내 Nitorgen 깊이 분해능 향상 연구

  • Lee, Jong-Pil;Choe, Geun-Yeong;Kim, Gyeong-Won;Kim, Ho-Jeong;Han, O-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.41-41
    • /
    • 2011
  • Flash memory에서 tunnel oxide film은 electron tunnelling 현상을 이용하여 gate에 전하를 전달하는 통로로 사용되고 있다. 특히, tunnel oxide film 내부의 charge trap 현상과 불순물이 소자 특성에 직접적인 영향을 주고 있어, 후속 N2O/NO 열처리 공정에서 SiO2/Si 계면에 nitrogen을 주입하여 tunnel oxide film 특성을 개선하고 있다. 따라서 N2O/NO 열처리 공정 최적화를 위해서는 tunnel oxide film 내 N 농도와 분포에 대한 정확한 평가가 필수적이다[1]. 본 실험에서는 low energy magnetic SIMS를 이용하여 N2O로 열처리된 tunnel oxide film 내의 N농도를 보다 정확하게 평가하고자 하였다. 사용된 시료는 Si substrate에 oxidation 이후 N2O 열처리를 진행하여 tunnel oxide를 형성시켰으며, 분석 impact energy는 surface effect최소화와 최상의 depth resolution 확보를 위해 250eV를 사용하였으며, matrix effect와 mass interference를 방지하기 위해 MCs+ cluster mode[2]로 CsN signal를 검출하였다. 실험 결과, 특정 primary beam 입사각도에서 nitrogen depth resolution 저하 현상이 발생하였고, SIMS crater 표면이 매우 거칠게 나타났다. 이에, Depth resolution 저하 현상을 개선하기 위해 극한의 glancing 입사각 조건으로 secondary extraction voltage 변화를 통해 depth resolution이 개선되는 최적의 impact energy와 primary beam 입사각 조건을 확보하였다. 그 결과 nitrogen의 depth resolution은 1.6nm의 depth resolution을 확보하였으며, 보다 정확한 N 농도와 분포를 평가할 수 있게 되었다.

  • PDF

External Beam Radiotherapy for Primary Spinal Cord Tumors (척수종양의 방사선 치료)

  • Chun, Ha-Chung
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.197-203
    • /
    • 1989
  • Of 34 evaluated patients with primary spinal cord tumors, 32 were irradiated at our institution between 1969 and 1983. The results are reported of 32 patients, 16 with ependymoma and 16 with astrocytoma, who were treated with post-operative external beam radiotherapy following biopsy or subtotal resection Twenty-nine patients received $45\~55Gy$ megavoltage beam irradiation in $5\~6$ weeks and the remaining three patients received less than 40Gy. Spinal cord was in the irradiated field for six patients who received more than 50Gy. The minimum follow-up was five years. Five and ten year acturaial survival rates for entire group of patients were $73\%(22/30)\;and\;50\%(8/16)$, including three patients who were salvaged by surgery after radiation failures. Corresponding five and ten year relapse free survival rates were $60\%(18/30)\;and\;32\%(6/19)$, respectively. Of the 29 patients who recived more than 45Gy, relapse free survival at five years was $63\%(17/27)$. Treatment failed in 13 patients and all of those failures were in the irradiated portal. Patients with ependymomas have significantly better relapse free survival than those with astrocytomas, $80\%\;vs.\;40\%$ (p<0.05). There was significant difference in survival between patients with tumors involving the cervical spine and those with tumors in the other loactions, $45\%$ vs. $89\%(p<0.05)$. There was no significant differnece in survival between patients with cauda equina tumors and those with tumors at spinal cord, $100\%\;vs.\;68\%(p>0.05)$. No radiotherapy related neurological deficit was noted with a maximum 20 year follow-up. This study confirms that external beam radiotherapy is a safe and effective treatment modality for primary spinal cord tumors.

  • PDF

Evaluation of Scatter Reduction Effect of the Aft-Multiple-Slit (AMS) System Using MC Simulation (MC 시뮬레이션을 이용한 Aft-Multiple-Silt 시스템의 산란선 제거 효과 평가)

  • Chang, Jin-A;Suh, Tae-Suk;Jang, Doh-Yun;Jang, Hong-Seok;Kim, Si-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • Purpose: We designed the aft-multiple-slit (AMS) system to reduce scatter in cone-beam computed tomography (CBCT). As a preliminary study, we performed a Monte Carlo N-Particle Transport Code (MCNP) simulation to verify the effectiveness of this system. Materials and Methods: The MCNPX code was used to build the AMS geometry. An AMS is an equi-angled arc to consider beam divergence. The scatter-reduced projection images were compared with the primary images only and the primary plus scatter radiation images with and without AMS to evaluate the effectiveness of scatter reduction. To obtain the full 2 dimensional (2D) projection image, the whole AMS system was moved to obtain closed septa of the AMS after the first image acquisition. Results: The primary radiation with and without AMS is identical to all the slit widths, but the profiles of the primary plus scattered radiation varied according to the slit widths in the 2D projection image. The average scatter reduction factors were 29%, 15%, 9%, and 8% when the slit widths were 5 mm, 10 mm, 15 mm, and 20 mm, respectively. Conclusion: We have evaluated the scatter reduction effect of the AMS in CBCT imaging using the Monte Carlo (MC) simulations. A preliminary study based on the MCNP simulations showed a mount of scatter reduction with the proposed system.

Seismic behavior of reinforced concrete interior beam-column joints with beams of different depths

  • Xing, G.H.;Wu, T.;Niu, D.T.;Liu, X.
    • Earthquakes and Structures
    • /
    • v.4 no.4
    • /
    • pp.429-449
    • /
    • 2013
  • Current Design Codes for Reinforced Concrete (RC) interior beam-column joints are based on limited experimental studies on the seismic behavior of eccentric joints. To supplement existing information, an experimental study was conducted that focused on the effect of eccentricity of the deeper beams with respect to the shallow beams. A total of eight one-third scale interior joints with beams of different depths were subjected to reverse cyclic loading. The primary variables in the test specimens were the amount of joint transverse reinforcement and the cross section of the shallow beams. The overall performance of each test assembly was found to be unsatisfactory in terms of joint shear strength, stiffness, energy dissipation and shear deformation. The results indicated that the vertical eccentricity of spandrel beams in this type of joint led to lower capacity in joint shear strength and severe damage of concrete in the joint core. Increasing the joint shear reinforcement was not effective to alter the failure mode from joint shear failure to beam yielding which is favorable for earthquake resistance design, whereas it was effective to reduce the crack width at the small loading stages. Based on the observed behavior, the shear stress of the joint core was suggested to be kept as low as possible for a safe and practical design of this type of joint.