• Title/Summary/Keyword: Primary Frequency Regulation

Search Result 22, Processing Time 0.033 seconds

Cascaded Multi-Level Inverter Based IPT Systems for High Power Applications

  • Li, Yong;Mai, Ruikun;Yang, Mingkai;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1508-1516
    • /
    • 2015
  • A single phase H-bridge inverter is employed in conventional Inductive Power Transfer (IPT) systems as the primary side power supply. These systems may not be suitable for some high power applications, due to the constraints of the power electronic devices and the cost. A high-frequency cascaded multi-level inverter employed in IPT systems, which is suitable for high power applications, is presented in this paper. The Phase Shift Pulse Width Modulation (PS-PWM) method is proposed to realize power regulation and selective harmonic elimination. Explicit solutions against phase shift angle and pulse width are given according to the constraints of the selective harmonic elimination equation and the required voltage to avoid solving non-linear transcendental equations. The validity of the proposed control approach is verified by the experimental results obtained with a 2kW prototype system. This approach is expected to be useful for high power IPT applications, and the output power of each H-bridge unit is identical by the proposed approach.

A Study to Revitalize of the Honorary Industrial Safety Inspector System - In Construction Industry - (명예산업안전감독관제도 활성화 방안 연구 -건설업 중심으로-)

  • Yoon, Jo-Duk;Han, Choong-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.72-82
    • /
    • 2007
  • The purpose of this study is to put forward revitalization of the Honorary Industrial Safety Inspector System by using the survey(2006.05) of the Honorary Industrial Safety Inspector in the Construction Industry. It can be summarized to develop the system as the following: 1) If there are neither labor union nor representative of workers in a company, workers must elect the representative of workers at first and then recommendation of the honorary industrial safety inspector by the representative of workers, 2) It should regulated in the industrial safety and health act about the tenure of the representative of workers and the process of election, 3) Prohibition the honorary industrial safety inspector as the employer members in the Industrial Safety and Health Committee and exclusion of both main office supervisor and subcontract-company supervisor from the appointment of the honorary industrial safety inspector, 4) Measures to realize the prohibitive regulation of unfavorable treatment on the grounds that the inspector has performed legitimate activities as an Honorary Industrial Safety Inspector, 5) Statutory regulation of the educations' hours(primary education & professional education), 6) Specification of the professional education and increase of the frequency, 7) Support of the government(the Ministry of Labor) to revitalize the honorary industrial safety inspector system, 8) Put in a statutory form the regular hours to carry out the work of the honorary industrial safety inspector in the workplace.

Thickness-Vibration-Mode Piezoelectric Transformer for Power Converter

  • Su-Ho lee;Yoo, Ju-Hyun;Yoon, H.S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • This paper presents a new sort of multilayer piezoelectric ceramic transformer for switching regulation power supplies. This piezoelectric transformer operate in the second thickness resonant vibration mode. Accordingly its resonant frequency is higher than 1 NHz, Because output power is low if input and output part of transformer are consisted of single layer, this research suggests a new method, which is consisted of both input and output part of transformer have 2-layered piezoelectric ceramics, The size of transformer is 20 mm in width and length, and 1.4 mm in thickness, respectively, To design a high efficient switching circuit of the transformer, internal circuit parameters were measured and then weve calculated a parameter of inductor nd capacitor to design a driving circuit, Weve used a MISFET and its driver circuit modified a calp oscillator circuit as the primary switching circuit.

  • PDF

Effective Cooperative FFT based pilot Sensing Scheme for Detecting DTV Signals in Cognitive Radio (인지무선 시스템에서 DTV 신호 검출을 위한 FFT 기반의 협력 파일럿 센싱)

  • Lee, So-Young;Kim, Eun-Cheol;Kim, Jin-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • Cognitive radio (CR), which is proposed as a technology that utilizes the frequency resources effectively, has been studied to relive scarcity of the frequency resources. Also, FCC revises the regulation to reuse the TV white spaces for applying CR system and allows to use the TV white spaces by CR devices and use of CR device may be regularized after conversion by DTV in 2009. In order to reuse the TV bands without harmful interference to primary user, correct spectrum sensing should be needed to detect DTV signals that is the primary user in TV bands. In this paper, we detect the DTV signal using FFT-based pilot sensing and cooperative sensing scheme is applied for the reliability of the sensing performance and the accuracy of the detection probability. Also, in order to make the reliable decision, the majority rule is proposed.

Study on Clinical Education for Nursing in Hospitals in Korea (간호학 임상실습교육 실태 조사)

  • Song, Jiho;Kim, Miwon
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.19 no.2
    • /
    • pp.251-264
    • /
    • 2013
  • Purpose: The purpose of this study was to ascertain the current state of clinical nursing education at hospitals. Methods: Questionnaires were sent out to 236 hospitals which have over 300 beds. Out of these, 116 hospitals responded, and the collected data was analyzed by mean, frequency, t-test, and ANOVA test. Results: These hospitals have teaching agreements with 4.2 nursing colleges and clinical education lasts 8 months. Clinical education status regarding hospital characteristics, between a university hospital, non-university hospitals, among advanced general hospitals, general hospitals, and special hospitals showed statistical differences in colleges per hospital and nurses' degree. 37.9% of cases have no internal regulation for nursing education, and in 68.1% of cases, students' practice was limited to simple nursing care. The current primary guide for student's practice was head nurse (61.25%), and the course professor took charge of mainly the conference. The difficulties as an educational hospital are increases in work load, difficulties in teaching, excessive number of students, simultaneous practical training, complaints from patients, lack in training manpower, and stress. Conclusion: This study determined that the big hospitals are heavily burdened by nursing education and that it will be necessary to establish standards for educational hospitals to ensure higher quality education.

Performance of Cognitive Radio Systems Based on Multiple Orthogonal Sequences (다중 직교 시퀀스를 이용한 인지 무선 시스템의 성능)

  • Lee, Kyung-Sun;Kim, Yoon-Hyun;Kim, Jin-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.976-984
    • /
    • 2012
  • Ad hoc networks can be used under difficult conditions, where it is difficult to construct infrastructures, such as shadowing areas, disaster areas, war area, and so on. In order to support to considerable and various wireless services, more spectrum resources are needed. However, efficient utilization of the frequency resource is difficult because of spectrum scarcity and the conventional frequency regulation. Ad-hoc networks employing cognitive radio(CR) system that guarantee high spectrum utilization provide effective way to increase the network capacity. However, there is a problem that all CR user do not fairly use the primary user's idle bandwidth which has been sensed. In this paper, to solve this problem, we propose the spectrum sharing algorithm which uses the multiple orthogonal sequences based on the code division multiple access(CDMA). From the proposed algorithm, it is expected that system performance of CR based ad-hoc network is improved significantly and it can be applied to the implementation of CR based ad-hoc network system.

Performance of Detection Probability with Adaptive Threshold Algorithm for CR Based on Ad-Hoc Network (인지 무선 기반 애드 혹 네트워크에서 적응적 임계치 알고리즘을 이용한 센싱 성능)

  • Lee, Kyung-Sun;Kim, Yoon-Hyun;Kim, Jin-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.632-639
    • /
    • 2012
  • Ad-hoc networks can be used various environment, which it is difficult to construct infrastructures, such as shadowing areas, disaster areas, war area, and so on. In order to support to considerable and various wireless services, more spectrum resources are needed. However, efficient utilization of the frequency resource is difficult because of spectrum scarcity and the conventional frequency regulation. Ad-hoc networks employing cognitive radio(CR) system that guarantee high spectrum utilization provide effective way to increase the network capacity. In conventional CR based ad-hoc network, it uses constant threshold value to detect primary user signal, so the results become not reliable. In this paper, to solve this problem, we apply adaptive threshold value to the CR based ad-hoc network, and adaptive threshold is immediately changed by SNR(Signal to Noise Ratio). From the simulation results, we confirmed that proposed algorithm has the greatly better detection probabilities than conventional CR based ad-hoc network.

Effect of Ultrasound Therapy at the ST11 on Sympathetic Nervous System Change: A Prospective Randomized Controlled Study (기사혈(氣舍穴, ST11)에 적용한 혈위 초음파요법이 교감신경계에 미치는 영향: 전향적 무작위 대조군 연구)

  • Shinwoo Kang;Dongho Keum
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.167-184
    • /
    • 2023
  • Objectives This study was designed to assess the effectiveness of ultrasound therapy at the ST11 for regulation of sympathetic hyperactivity. Methods Forty healthy adult subjects were assigned to experimental group and control group. After taking mental stress, ultrasound therapy was applied at the ST11 in experimental group and sham-ultrasound therapy was applied in control group. The evaluation of sympathetic activity was measured by blood pressure, pulse rate, and heart rate variability at 3 times (Time 1: before the stress stimulation, Time 2: after the stress stimulation, Time 3: after the intervention). The primary end point was consisted of normalized (norm) low frequency (LF)/high frequency (HF) ratio, LF (norm), HF (norm). The secondary end point was consisted of systolic blood pressure, diastolic blood pressure, pulse rate, mean heart rate, standard deviation of NN intervals, root mean square of the successive differences, total power (log). Results After the stress stimulation, all subjects showed sympathetic hyperactivity. After the intervention, the experimental group showed lower sympathetic activity than the control group. Comparing the Time 3 and Time 1, the experimental group showed no significantly differences in sympathetic activity while the control group showed higher sympathetic activity in Time 3 than Time 1. Comparing the Time 3 and Time 2, the experimental group showed lower sympathetic activity in Time 3 than Time 2 while the control group showed higher sympathetic activity in Time 3 than Time 2. Conclusions We suggest that the ultrasound therapy at ST11 can decrease sympathetic activity in sympathetic hyperactivity condition.

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.

High Efficient Inductive Power Supply System Implemented for On Line Electric Vehicles

  • Huh, Jin;Park, Eun-Ha;Jung, Gu-Ho;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.105-110
    • /
    • 2009
  • The On Line Electric Vehicles(OLEV) that can pick up inductive power from underground coils on driving with high efficiency have been developed this year, and is now proposed in this paper. The IPS(Inductive Power Supply) system consists of power supply inverters, power supply rails, pick up modules, and a regulator. There are 3 generations of IPS have been developed so far, and the $4^{th}$ generation IPS is being developed. The $1^{st}$ generation has been demonstrated this Feb. 27, which is equipped with mechanically auto tracking pick-up module with 1cm air gap, and showed 80% power efficiency. The $2^{nd}$ generation IPS applied to an 120kW (average)/240kW(peak) motor powered electric bus has 17cm air gap with 72% power efficiency. For the $2^{nd}$ generation IPS, the Power supply inverter has 440V, 3phase input and 200A @ 20kHz output. The test power supply rail of 240m long is segmented by 60m each, where newly developed core structure and power cable are constructed under the road covered with asphalt of 5cm thickness. The pick-up modules which consist of core, winding wire, and rectifiers are fixed to the bottom of the bus which can carry more than 40 passengers and can pick up max. 60kW. To remove parasitic component and to transfer maximum power between them resonant circuit topology is applied to the primary and secondary sides. The EMF level is below 62.5mG at 1.75m from the center of the road to meet the regulation. Several effective ways of reducing EMF levels have been developed. In addition, effective ways to solve problems related high frequency power cables buried in ground and it's proof from soil have been studied also. This development shows that the IPS system is capable of supplying enough power to the pick-up of OLEV and can reduce battery size, weight and cost, which means the IPS with OLEV is one of the best candidate for EV.

  • PDF