• 제목/요약/키워드: Prevention System

검색결과 4,769건 처리시간 0.028초

현행소방시설설치기준의 분석과 개선방안에 관한 연구 (A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings)

  • 정병재;이경회
    • 한국화재소방학회논문지
    • /
    • 제4권2호
    • /
    • pp.3-13
    • /
    • 1990
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the ]after fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern Higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First. We are going to look history of the fire protection system and change course of that with the year and facility. Second, We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

현행소방시설설치기준의 분석과 개선방안에 관한 연구II (Part II A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings)

  • 정병재;이경회
    • 한국화재소방학회논문지
    • /
    • 제5권1호
    • /
    • pp.5-14
    • /
    • 1991
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it Is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility. Second. We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

실외 센서네트워크 기반 재해방지 시스템을 위한 위험지역 예측기법 (Dangerous Area Prediction Technique for Preventing Disaster based on Outside Sensor Network)

  • 정영진;김학철;류근호
    • 정보처리학회논문지D
    • /
    • 제13D권6호
    • /
    • pp.775-788
    • /
    • 2006
  • 무선 통신 기술의 발달과 무선기기의 소형화, 그리고 환경에 대한 감지와 제어를 수행하는 센서 네트워크 기술의 확산으로 환경오염, 터널 및 건축물의 붕괴, 홍수, 태풍, 지진 등의 재난에 대비하기 위한 재해 감시 시스템에 대한 연구가 활발히 진행되고 있다. 재해 감시 시스템은 원격지의 상태 정보를 검출하고, 재해 상황을 판단하기 위한 규칙 처리 과정 후, 인식된 상황에 따라 방재작업을 지원한다. 그러나 기존의 모니터링 시스템들은 주로 현재 데이터를 위주로 간단한 집계함수 및 연산자만을 지원하기 때문에, 재해를 미리 예측하고 방재하기에는 부족한 점이 있다. 따라서 이 논문에서는 실외 센서 네트워크 및 공간 정보를 고려하여 재해 위험 지역을 미리 예측하는 재해 방지 시스템을 설계, 구현한다. 제시된 위험 지역 예측 기법은 현재 센서 데이터를 토대로 시간에 대한 공간 정보의 변화를 고려하여 미래에 재해 위험이 있는 지역을 추정하여 제시한다. 이로 인해 재해를 미리 예측하고 방비할 수 있게 되고, 재해 피해 감소 및 복구비용을 줄일 수 있다. 제시된 재해 방지 시스템과 위험 지역 예측 기법은 센서네트워크를 기반으로 하는 다양한 재해 방지 시스템에 활용되어 재해 예방 및 피해 감소에 많은 도움을 줄 수 있다.

건축물 범죄예방 기준 확대적용에 따른 경제성 분석 (An Economic Analysis by Applying Extended Crime Prevention Standards for Buildings)

  • 현태환;조영진
    • 대한건축학회논문집:계획계
    • /
    • 제35권11호
    • /
    • pp.53-60
    • /
    • 2019
  • Multi-unit house, multi-household house, row house and apartments with less than 500 households were included in the list of anti-crime for buildings following the revision of the "notice of crime prevention building standards" on July 31, 2019. Strengthening the performance of crime prevention buildings is inevitable to increase the cost of building construction, including installation of preventive facilities and use of facilities that have secured performance. Thus an economic analysis on the costs and expected benefits of implementing the standards is required for social consensus. Economic analysis is divided into cost analysis and benefit analysis. This study aims to perform an economic analysis on the installation of crime prevention facilities in the buildings subject to expanded crime prevention obligations. Cost analysis is calculated as the sum of the cost of installation and the price of the crime prevention facilities installed for each target residential building. Benefit analysis is calculated as the social cost of targeted crimes that are expected to decrease due to the installation of crime prevention facilities. Economic analysis shows that the total cost of installing crime prevention facilities in residential buildings is estimated at 107.31 billion won per year, while the total benefit from enhanced crime prevention performance is estimated at 9.38 billion won per year. Considering inflation, benefits are expected to outpace costs in the 28th year since the system was implemented.

Design and Implementation of Community-based Hazard Mapping Support System Based on Mobile Cloud in Traditional Towns with Local Heritage

  • Min, Byung-won
    • Journal of Platform Technology
    • /
    • 제6권3호
    • /
    • pp.3-9
    • /
    • 2018
  • This paper describes the design and trial development of a system that supports continuous hazard mapping by local residents in their daily life. We performed an interview survey to design our system in a model traditional town in Saga Prefecture, Japan. The results show that despite continued efforts, many practical problems remain and residents feel unsafe. Considering these results, we designed and developed a unique information and communication technology-based support system that contributes to community-based disaster prevention and reduction. The continuous resident participation and posting design are the core concept for our community-based approach. Our system continues to support making a hazard map by integrating the community-based hazard information. Local residents register information (disaster types, risk level, photographs, comments, positional information) about locations that could be dangerous in a disaster. In addition, our system enables information sharing through a Web server. We expect that this information sharing will allow local hazard information for each district to be used.

Design and Implementation of Community-based Hazard Mapping Support System for Traditional Towns with Local Heritage

  • Min, Byung-won
    • International Journal of Advanced Culture Technology
    • /
    • 제6권3호
    • /
    • pp.193-200
    • /
    • 2018
  • This paper describes the design and trial development of a system that supports continuous hazard mapping by local residents in their daily life. We performed an interview survey to design our system in a model traditional town in Saga Prefecture, Japan. The results show that despite continued efforts, many practical problems remain and residents feel unsafe. Considering these results, we designed and developed a unique information and communication technology-based support system that contributes to community-based disaster prevention and reduction. The continuous resident participation and posting design are the core concept for our community-based approach. Our system continues to support making a hazard map by integrating the community-based hazard information. Local residents register information (disaster types, risk level, photographs, comments, positional information) about locations that could be dangerous in a disaster. In addition, our system enables information sharing through a Web server. We expect that this information sharing will allow local hazard information for each district to be used.

건설재해예방 기술지도의 문제점 분석 및 개선방안 (The Problem Analysis and Improvement of Technical Guidance On Construction Accident Prevention)

  • 오희근;김용수
    • 대한안전경영과학회지
    • /
    • 제18권2호
    • /
    • pp.19-27
    • /
    • 2016
  • Safety accident rate of small-medium construction site is high. because of lack of safety management system, lack of safety management capacity, lack of investment for safety, Owner's insufficient awareness about safety. In order to improve this, Currently in Occupational Safety and Health Act, Construction site of amounts more than 300 million won less than 120 billion (architectural),150 billion won(civil) mandatory subject to the technical guidance on construction accident prevention. Context of construction accident causes with construction accident rate relationship analysis and case analysis of technical guidance, through a survey of stakeholders in the technical guidance drawn the problems of the construction accident prevention technical guidance system and ways to improve on this.

태양광 접속반의 자동 화재 예방 및 진압 시스템 설계 (Design of Automatic Fire Prevention and Suppression System for Photovoltaic Connection Module)

  • 이강원;양오
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.33-38
    • /
    • 2022
  • A solar power generation system uses a solar module that collects solar radiation energy, a connecting board that collects DC power generated from the solar module, and a diode to prevent reverse current from flowing from an inverter to the solar module. The existing photovoltaic connection module consists of only fuses and diodes for reverse polarity and overcurrent blocking, and does not have fire diagnosis, prevention, and suppression functions in the event of a fire. To solve this problem, this paper presents a method to monitor the internal state of the photovoltaic connection module using several sensors and to prevent and extinguish a fire using solenoid valves and fire extinguishing agents when a fire is detected. Through the experiment, it was confirmed that the proposed method normally suppresses the fire in event of a fire.