• Title/Summary/Keyword: Pressure-tightness

Search Result 83, Processing Time 0.021 seconds

Studies on Garment Restraint(I) -Change of Skin Temperature by Continuous Restraint Method- (의복의 구속성에 관한 연구(I) -지속적인 구속방법에 따른 피부온 변화에 대하여-)

  • 심부자
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.1
    • /
    • pp.13-25
    • /
    • 1991
  • We measured change of peripheral skin temperature and mean skin temperature when the upper arm and thigh are pressured in order to know the effect of skin pressure applied by clothing on blood circulation. After release from pressure, we observed also recovery condition. At the same time, we examined relation between pressure and a feeling of thightness. Three physiques of healthy females, namely slender, standard and plump, served as subjects. We used continuous restraint method with skin pressure applied by experimental fabric for 10 min. As a result of this experiment, we obtained following findings. 1. The significant difference was marked at the pressure, measuring time and physique with change of skin temperature under upper arm restraint. The peripheral and mean skin temperature decreased with the lapse of restraint time. A remarkable tendency observed according to the increase of restraint pressure. Recovery condition after release from pressure not yet recovered to original state, for all after a lapse of 10 min. 2. The significant difference was marked at the pressure, measuring time and physique with change of skin temperature under thigh restraint, especially different physique was remarkable among them. The peripheral skin temperature decreased or decreased. Recovery condition after release from pressure was the same upper arm. 3. Main factor affecting the evaluation of a feeling of tightness was restraint pressure. The value of pressure sensation made remarkable declined after a lapse of 10 min restraint time. Individual differences, however, were shown in pressure sensation.

  • PDF

Autofrettage effects on strength and deformation of fiber reinforced pressure vessel

  • Wang, X.;Chen, X.
    • Structural Engineering and Mechanics
    • /
    • v.27 no.3
    • /
    • pp.277-292
    • /
    • 2007
  • Based on the composite finite element simulation and a series of hydrostatic pressure and burst tests, autofrettage effects on strength and deformation of fiber reinforced pressure vessel with metallic liners have been studied in the paper (autofrettage: during the course of one pressure taking effect, the increasing internal stress in metallic liner can surpass the yielding point and the plastic deformation will happen, which result in that when there is no internal pressure, there are press stress in liner while tensile stress in fiber lamination). By making use of a composite finite element Ansys code and a series of experiments, the autofrettage pressure is determined in order to make the aluminium liner be totally in elastic state, under given hydrostatic test pressure. The stress intensity factors of the longitudinal crack in aluminum liner end under internal pressure and thermal loads have been computed and analyzed before and after the autofrettage processing. Through numerical calculation and experiment investigations, it is found that a correct choice for autofrettage pressure can improve the gas-tightness and fatigue strength of FRP vessel.

Air-tightness Evaluation of Tube Structures for Super-speed Tube Railway Systems: I. Analytical Modeling and Material Test (초고속 튜브철도 시스템을 위한 튜브 구조물의 기밀성 평가 : I. 해석모델 수립 및 재료 기밀성)

  • Park, Joo-Nam;Nam, Seong-Won;Kim, Lee-Hyeon;Yeo, In-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • This paper presents a preliminary study for air-tightness evaluation of vacuum tube structures for super-speed tube railway systems. The formula for flow rate of the air caused by the pressure difference of the inside and outside of the tube structure is derived based on Darcy's law. A test is then performed to measure the air-permeability of concrete with various compressive strengths, the result of which is used for analytical simulation of the air intrusion for a tube structure with a preliminarily defined section. It has been shown that concrete with the compressive strength of at least more than 50MPa is recommended for effective operation and maintenance of the vacuum pump systems, as the air-permeability of concrete is inversely proportional to the exponent of its compressive strength.

Analysis of the Impacts of Stack Effect in High-rise Residential Buildings (초고층 주거용 건물에서의 연돌효과 영향 분석)

  • 양인호;조재훈;김광우;여명석
    • Journal of the Korean housing association
    • /
    • v.13 no.4
    • /
    • pp.61-66
    • /
    • 2002
  • The objectives of this study are to clarify the impacts of stack effect in high-rise residential buildings and to present technical methods to reduce stack effect. For the evaluation of stack effect, architectural design guidelines were used and computer program simulations based on network model were performed. The evaluation shows that problems due to stack effect may be reduced by appropriate architectural designs, such as increase in air-tightness of building envelop, and provision of vestibules around entrance and elevator hall doors.

A Study on the Characteristics of the interface in Tube / Tubesheet of the Nuclear Steam Generator by Explosive Bonding (폭발접합된 원자력 증기발생기 튜브/튜브시트 계면 특성에 관한 연구)

  • 이병일;공창식;심상한;강정윤;이상래
    • Explosives and Blasting
    • /
    • v.17 no.4
    • /
    • pp.32-50
    • /
    • 1999
  • This study deals with interface charactristics of tube and tubesheet of the nuclear steam generator by the explosive expansion in order to take advantage of optimum expansion ratio, pull-out strength and leakage tightness and improvement of the resisitance on the stress corrosion cracking for low residual stress. The paper also show the relationship between roll, hydraulic and explosive expansion. The results obtain are as follows (1) Because of the explosive bonding is to use the high speed pressure and energy by the explosive, workability is good, bonding region is homogenous (2) Expansion ratio is 2.7%, Pull-out strength 850kg, Leakage strength $500kg/cm^2$. Clearance gap is 10~30mm in case of explosive expansion and interface structure of the tube and tubesheet is optimum condition. (3) As the transition region of the explosive expansion is inactive, the resistance of the stress corrosion cracking is increases 30~40% compare to the roll and hydraulic expansion.

  • PDF

An Experimental Study of Window Air Tightness according to Filling Piece Shapes (창호 풍지판 형상에 따른 기밀성의 실험적 연구)

  • Yun, Yura;Park, Jong-Jun;Kim, Young Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.63-68
    • /
    • 2016
  • To study the effect of installation and the shapes of filling pieces used for windows on the infiltration rate, infiltration tests were performed with two types of sliding windows and two shapes for the filling pieces. Infiltration occurred most at the top and bottom parts of the center location where two windows overlap, indicating the necessity of a filling piece to be installed at these locations. Infiltration velocity is proportional to the square root of the pressure difference, complying well with the theoretical correlation. Infiltration is reduced about 50% by the filling piece installation. This study shows that filling pieces are essential and their shapes play significant roles in reducing the infiltration of windows.

E/V Shaft Cooling Method as a Stack Effect Countermeasure in Tall Buildings

  • Lee, Joonghoon;Song, Doosam;Jeong, Eunyoung
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • The higher the building height and the larger the temperature difference between the outdoor and indoor space, the more remarkable is the draft driven by the stack effect in high-rise buildings. Moreover, the stack effect can bring about the deterioration of habitability and the degradation of the performance of the indoor control system in high-rise buildings. In this study, as a measure to attenuate the stack effect, the E/V shaft cooling method was proposed and its performance was compared with the conventional stack effect control method for strengthening the air-tightness of the building using a numerical simulation method. The total decreasing ratios on the stack effect in a building were compared, and the probabilities of the secondary problems were analyzed. The results show that the E/V shaft cooling is very effective to decrease the stack effect in a high-rise building in terms of the reduction performance and application. Moreover, this method does not cause secondary problems, such as stack pressure transition to other walls, unlike the conventional stack effect mitigation method.

FEA(Finite Element Analysis) Study for Electronic Hydrogen Regulator of Confidentiality Improvement (전자식 수소레귤레이터 기밀성 향상을 위한 FEA 연구)

  • Son, Won-Sik;Song, Jae-Wook;Jeon, Wan-Jae;Kim, Seung-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.175-181
    • /
    • 2019
  • In the case of a conventional single stage decompression regulator used for large depressurization in the hydrogen fuel cell system of a fuel cell electric vehicle (FCEV), problems can arise, such as pulsation, slow response, hydrogen brittleness, leakage, high weight, and high cost due to high decompression. Most of these problems can be overcome easily using two decompression mechanisms (two-stage structures). In addition, a wide outlet-pressure control range can be secured if an electronic solenoid is applied to the second decompression. Accordingly, it is necessary to improve the precision of the outlet pressure of a two-stage pressure-reducing regulator and develop techniques, such as leakage prevention, durability, light weight, and price reduction. Therefore, to improve the outlet pressure accuracy and prevent leakage, the structural part before and after decompression to improve the air tightness were divided and the analysis was carried out assuming that the valve part was closed (open ratio: 0%) after each initial internal pressure application.

A STUDY ON THE MINIMUM CROSS-SECTIONAL AREA OF HIGH-SPEED RAILWAY TUNNEL SATISFYING PASSENGER EAR DISCOMFORT CRITERIA (승객 이명감 기준을 만족하는 고속철도 터널 최소 단면적에 대한 연구)

  • Kwon, H.B.
    • Journal of computational fluids engineering
    • /
    • v.20 no.3
    • /
    • pp.62-69
    • /
    • 2015
  • Pressure change inside cabin as well as in tunnel has been calculated to assess the passenger pressure comfort of high-speed train. $C-STA^{TM}$, a CFD program based on axi-symmetric Navier-Stokes equation and Roe's FDS has been used to simulate the pressure change in tunnel during a high-speed train passing through it. To present the relative motion between the train and the tunnel, a modified patched grid scheme based on the structured grid system has been employed. The simulation program has been validated by comparing the simulation results with field measurements. Extensive parametric study has been conducted for various train speed, tunnel cross-sectional area and tunnel length to the pressure change in cabin. KTX-Sancheon(KTX2) high-speed train has been chosen for simulation and the train speed have been varied from 200 km/h to 375 km/h. The tunnel length has been varied from 300 m to 7.5 km and tunnel area from $50m^2$ to $120m^2$. Total 504 simulations have been conducted varying the parameters. Based on the database produced from the parametric simulations, minimum tunnel cross-sectional area has been surveyed for various train speeds based on Korean regulation on pressure change in cabin.

Correlation Analysis of Parameters affecting Pressure Distributions in Vertical Shafts by Design of Experiments (실험계획법에 의한 수직샤프트내 압력분포에 영향을 미치는 인자간 상관관계 분석)

  • Han, Hwa-Taik;Shin, Chul-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.883-888
    • /
    • 2008
  • Various effluents generated in cooking processes contribute a great deal to indoor air pollution among many other indoor pollutants such as dusts from outdoor and carbon dioxide from human body. Kitchen exhaust hoods are not believed to exhaust indoor contaminants properly in many cases, while generating too much noise. Instead of focusing on individual products of kitchen hoods, we should address the problem by attacking the ventilation system as a whole including vertical shafts and building air-tightness. In this study, it is intended to investigate the pressure distribution along the vertical shaft depending on various system parameters, such as shaft size, concurrent hood usage rate, roof fan, inlet pressure loss, and outdoor temperature. The maximum static pressure in the vertical shaft has been obtained using the method of design of experiments and analyzed by the analysis of variance. The results can be used for the design of kitchen exhaust systems by analyzing the pressure distributions in vertical shafts.

  • PDF