• Title/Summary/Keyword: Pressure-rise rate

Search Result 277, Processing Time 0.028 seconds

A unique Vietnam's red clay-based brick reinforced with metallic wastes for γ-ray shielding purposes: Fabrication, characterization, and γ-ray attenuation properties

  • Ta Van Thuong;O.L. Tashlykov;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1544-1551
    • /
    • 2024
  • A unique brick series based on Vietnamese clay was manufactured at 114.22 MPa pressure rate for γ-ray attenuation purposes, consisting of (x) metallic waste & (90%-x) red clay mineral & 10% (hardener mixed with epoxy resin), where (x) is equal to the values 0%, 20%, 40%, 50%, and 70%. The impacts of industrial metal waste ratio in the structure and radiation protective characteristics were evaluated experimentally. The increase in metallic waste doping concentrations from 0% to 70% was associated with an increase in the manufactured brick's density (ρ) from 2.103 to 2.256 g/cm3 while the fabricated samples' porosity (Φ) decreased from 11.7 to 1.0%, respectively. Together with a rise in fabricated brick's density and a decrease in their porosities, the manufactured bricks' γ-ray attenuation capacities improved. The measured linear attenuation coefficient (μ, cm-1) was improved by 30.8%, 22.1%, 21.6%, and 19.7%, at Eγ equal to the values respectively 0.662, 1.173, 1.252, and 1.332 MeV, when the metallic waste concentration increased from 0% to 70%, respectively. The study demonstrates that manufactured bricks exhibit superior radiation shielding properties, with radiation protection efficiencies of 88.4%, 90.0%, 91.7%, 92.1%, and 92.4% for bricks with industrial metal waste contents of 0%, 20%, 40%, 50%, and 70%, respectively, at γ-ray energy (Eγ) of 1.332 MeV.

Comparative Investigation of Convective Heat Transfer Coefficients for Analyzing Compressed Hydrogen Fueling Process (압축 수소 충전 공정 해석을 위한 대류 열전달 계수 비교 분석)

  • Hyo Min Seo;Byung Heung Park
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.123-133
    • /
    • 2023
  • Commercial hydrogen fuel cell vehicles are charged by compressing gaseous hydrogen to high pressure and storing it in a storage tank in the vehicle. This process causes the temperature of the gas to rise, to ensure the safety to storage tanks, the temperature is limited. Therefore, a heat transfer model is needed to explain this temperature rise. The heat transfer model includes the convective heat transfer phenomenon, and accurate estimation is required. In this study, the convective heat transfer coefficient in the hydrogen fueling process was calculated and compared using various correlation equations considering physical phenomena. The hydrogen fueling process was classified into the fueling line from the dispenser to the tank inlet and the storage tank in the vehicle, and the convective heat transfer coefficients were estimated according to process parameters such as mass flow rate, diameter, temperature and pressure. As a result, in the case of the inside of the filling line, the convective heat transfer coefficient was about 1000 times larger than that of the inside of the storage tank, and in the case of the outside of the filling line, the convective heat transfer coefficient was about 3 times larger than that of the outside of the storage tank. Finally, as a result of a comprehensive analysis of convective heat transfer coefficients in each process, it was found that outside the storage tank was lowest in the entire hydrogen fueling process, thus dominated the heat transfer phenomenon.

Wearable Intelligent Systems for E-Health

  • Poon, Carmen C.Y.;Liu, Qing;Gao, Hui;Lin, Wan-Hua;Zhang, Yuan-Ting
    • Journal of Computing Science and Engineering
    • /
    • v.5 no.3
    • /
    • pp.246-256
    • /
    • 2011
  • Due to the increasingly aging population, there is a rising demand for assistive living technologies for the elderly to ensure their health and well-being. The elderly are mostly chronic patients who require frequent check-ups of multiple vital signs, some of which (e.g., blood pressure and blood glucose) vary greatly according to the daily activities that the elderly are involved in. Therefore, the development of novel wearable intelligent systems to effectively monitor the vital signs continuously over a 24 hour period is in some cases crucial for understanding the progression of chronic symptoms in the elderly. In this paper, recent development of Wearable Intelligent Systems for e-Health (WISEs) is reviewed, including breakthrough technologies and technical challenges that remain to be solved. A novel application of wearable technologies for transient cardiovascular monitoring during water drinking is also reported. In particular, our latest results found that heart rate increased by 9 bpm (P < 0.001) and pulse transit time was reduced by 5 ms (P < 0.001), indicating a possible rise in blood pressure, during swallowing. In addition to monitoring physiological conditions during daily activities, it is anticipated that WISEs will have a number of other potentially viable applications, including the real-time risk prediction of sudden cardiovascular events and deaths.

Characteristics of Toluene Removal in a Biotrickling Filter with Zeolite/Polyethylene Composite Media (제올라이트/폴리에틸렌 복합 담체를 이용한 Biotrickling Filter에서 톨루엔 제거 특성)

  • Hong, Sung-Ho;Lee, Chung-Sik;Lee, Jea-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.573-580
    • /
    • 2005
  • This study was to investigate the removal characteristics of toluene in a gas stream by using a biotrickling filter packed with zeolite-contained polyethylene media. The specific surface area and the void fraction of the media were $500\;m^2/m^3$ and 82%. The surface roughness of the media was higher than that of pure polyethylene media. The toluene removal efficiency decreased with increasing the inlet toluene concentration and gas flow rate. The maximum elimination capacity of toluene in the biotrickling filter was $64\;g/m^3{\cdot}hr$. During 200 days operation, toluene removal efficiency was maintained from 90% to 98% until 167 days, hereafter, it was rapidly reduced with a rise in pressure drop due to an excess proliferation of biomass on the media. Pressure drop and removal capability of the biotrickling filter was fully recovered after backwashing.

A Study of Design Method of an Axial-Type Suction Fan (축류형 흡입송풍기 설계기술에 관한 연구)

  • Choi, Hyoung-Jun;Kim, Chang-Su;Cho, Chong-Hyun;Cho, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.42-51
    • /
    • 2010
  • Many different types of fan have been applying to various industrial fields. Fan design methods are much different depending on the types of fan, operating conditions, and connecting parts at the inlet or exit of the fan etc. In this study, design methods for an axial-type suction fan are studied. This fan discharges the air in the relative static pressure of -285Pa to the atmosphere with the flow rate of $960m^3/min$. For three-dimensional blade design, three different design methods were applied, such as the free vortex method, the exponential method, and the cascade method. In the cascade method, the blade loading along the radial direction was obtained from the lift coefficient which was necessary to obtain the pressure rise on a fan rotor. This method is different from the free vortex and the exponential method which control the strength of the vortex. The fan performance prediction was conducted using the CFD with three different inlet ducts. The best fan performance was obtained when the fan was designed by using the cascade method. The designed fan using the exponential method showed better performance compared to a fan designed using the free vortex method. However, the fan performance was changed depending on the installed inlet ducts. So, an efficient fan can be designed with the adjustment of design variables on the basis of the flow structures within the fan as well as the fan design procedure.

A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ (주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구)

  • Lee, Jung-Hyun;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

Effect of Mean Diameter on the Explosion Characteristic of Magnesium Dusts (마그네슘의 폭발특성에 미치는 평균입경의 영향)

  • Han, Ou-Sup;Lee, Su-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.33-38
    • /
    • 2013
  • A study was carried out on the effect of particle size (mean diameter) on magnesium dust explosion. Experimental investigations were conducted in a 20-L explosion sphere, using 10 kJ chemical ignitors. Explosion tests were performed with three different dusts having mean diameter (38, 142, $567{\mu}m$) and the dust concentrations were up to $2250g/m^3$. The lower explosion limits(LEL) of magnesium dusts were about $30g/m^3$ at $38{\mu}m$ and $40g/m^3$ at $142{\mu}m$. LEL tended to increase with particle size and this means that the explosion probability of magnesium dust decreased with increase of particle size. The maximum explosion presssure ($P_m$) and $K_{st}$ (Explosion index) decreased with the increase of particle size. For magnesium powder of $567{\mu}m$, however, the explosive properties were not observed in the 5 kJ ignition energy.

Housing Need and Demand Assessment: Focused on Public Housing Development Projects (공공주택 사업지구의 수요평가모델 구축 연구)

  • Ji, Kyu-Hyun;Lee, So-Young;Kim, Yong-Soon
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • This study proposes a new housing need and demand assessment model centering on small-scale housing development projects and happy house development projects that reflected the recent changes in rental and small sized apartment centered public housing policies and development paradigms. The housing need and demand assessment model of public housing development projects consists of quantitative evaluation factors such as potential need indicator and demand pressure indicator and qualitative evaluation factors such as local condition indicator. The potential need indicators of small sized housing development projects are calculated by subtracting the stock of already-supplied constructed rental and purchased rental housings from the potential quantity of need drawn from the small regions such as -eup, -myeon, and -dong. In the potential need indicators of happy house development projects, the potential need is calculated from those who are expected to receive a happy house in the unit of -si, -gun, and -gu. In small-sized housing development projects, demand pressure indictors are the number and the proportion of those who opened a subscription deposit, the number of those who received basic livelihood security and the number of those who were patriots and veterans. The demand pressure indicators of the happy house development projects are stock ratio of small-sized houses, rate of rise in housing rent price, level of housing rent price, and rate of monthly rent house.

Effect of the Brain Death on Hemodynamic Changes and Myocardial Damages in Canine Brain Death Model -Electrocard iographic and Hemodynamic Changes in the Brain Death Model Induced by Gradual Increase of Intracranial Pressure- (잡견을 이용한 실험적 뇌사모델에서 뇌사가 혈역학적 변화와 심근손상에 미치는 영향 -제2보 : 뇌압을 점진적으로 증가시켜 유발한 뇌사모델의 심전도 및 혈역학적 변화-)

  • 조명찬;이동운
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 1996
  • We developed an experimental model of brain death using dogs. Brain death was induced by increasing the intracranial pressure (ICP) gradually by continuous Infusion of saline through an epidural Foley catheter in 5 mongrel dogs (weight, 18~22kg). Hemodynamic and electrocardiographic changes were evaluated continuously during the process of brain death and obtained the following results. 1. The average volume and time required to induce brain death was 4.8$\pm$1.0ml and 143.0$\pm$30.9minutes respectively. 2. There was a steady rise of the ICP after starting the constant infusion of saline, and ICP rised continuously until the brain death (122.0$\pm$62.5mmHg). After reaching to the maximal value (125.0$\pm$47.7mmHg) at 30 minutes after brain death, the ICP dropped and remained approximately constant at the slightly higher level than the mean arterial pressure (MAP). 3. MAP showed no change until the establishment of brain death and it declined gradually. The peak heart rate reached to 172.6$\pm$35.3/min at 30 minutes after the brain death. 4. Even though the body temperature and all hemodynamic variables, such as cardiac output, mean pulmonary arterial pressure, left ventricular (LV) end-diastolic pressure and LV maximum + dp/dt, were slightly greater than those of basal state, at the point of brain death, there was no statistically significant change during t e process of brain death. 5. There was no remarkable arrhythmias during the experiment except ventricular premature beats which was observed transiently in one dog at the time of brain death. Hemodynamic changes in the brain death model induced by gradual ICP increment were inconspicuous, and arrhythmias were rarely seen. Hyperdynamic state, which was observed at the point of brain death in another brain death model caused by abrupt ICP increase, was not observed.

  • PDF

Numerical Analysis of Load Reduction for Underground Arch Structures with Soft Zone Using Expanded PolyStyrene Geofoam (EPS Geofoam을 이용한 Soft Zone 적용방법에 따른 지중아치구조물의 하중저감에 관한 해석 연구)

  • Kim, Soo-Ha;Park, Jong-Sup;Kang, Jun-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.24-30
    • /
    • 2018
  • As the demand for underground space increases, many researchers have been studying the load reduction method using high compressible materials to solve for the stability problem of the overhead load and for the increase of the earth pressure which decreases the function of the underground structure. This paper determines the optimum soft zone and the effect of the using EPS Geofoam as a load reduction material to arch structures. A finite element analysis program, ABAQUS, is used to analyze the soil-structure interaction and the behavior of buried arch structures considering different four EPS Geofoam forms to confirm the most conservative shape. The optimum cross-sectional shape was determined by comparing the results of earth pressure reduction rate in accordance with the change of span-rise ratio and span length of the arch structure. It was confirmed that the earth pressure generated in the arch structure using the optimal soft zone selected by the numerical analysis was reduced by an average of 78%. In this study, the effect of EPS Geofoam on soil pressure reduction and its applicability to underground arch structures will provide an economical and conservative way to design underground structures and will help to increase the usability of deep underground space.