• Title/Summary/Keyword: Pressure-rise rate

Search Result 280, Processing Time 0.031 seconds

?Experimental Study on the Effects of Zanthoxyli Fructus and Fagarae mandshuricae Fructus (천초(川椒) 및 산초(山椒)의 효능(?能)에 관(關)한 실험적(實驗的) 연구(硏究))

  • O, Han-Gyun;Won, Jong-Hun;Jeong, Gyu-Man
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.4 no.1
    • /
    • pp.1-17
    • /
    • 1990
  • ?In order to investigate effects of Zanthoxyli Fructus (Sample-A) and Fagarae mandshuricae Fructus (Sample-B), experimental study was performed through observation on isolated - ileum analgesic, hypothermal, anti-pyretic, anti-inflammatory, capillary permeability, blood flow rate, blood pressure and respiratory works. The results were as follows; 1. In spontaneous movement of mice isolated-ileum, both samples were noted to have strong inhibitory action after temporary contraction, and to show antagonism against acetylcholine chloride and barium chloride. 2. Both samples were showed to have antihistamin work on guinea pig isolated-ileum 3. In analgesic work by the acetic acid method, only Fagarae mandshuricae Fructus was proved to have significant analgesic effect in mice. 4. Both sample groups indicated anti-pyretic and anti-inflammatory effect. 5. Both samples were noted to have inhibitory effect against capillary permeability ?rise in mice. ?6. Both samples were noted to have dose-dependent falling effect on blood pressure in rabbits.

  • PDF

Cooling Performance Analysis of a Sub-scale Calorimeter (축소형 칼로리미터의 냉각성능 해석)

  • 조원국;문윤완
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.3
    • /
    • pp.8-14
    • /
    • 2003
  • A cooling performance analysis has been made in the 8-channel calorimeter based on sub-scale KSR-III engine. Three-dimensional heat transfer analysis in cooling channels has been performed using the heat flux distribution through the chamber wall predicted from axi-symmetric compressible flow inside the combustion chamber. The heat flux distribution is verified against the published literature. Presented for the development and operation of the calorimeter are the coolant pressure drop, coolant temperature rise and the maximum chamber wall temperature. Required coolant flow rate is determined for given chamber pressure. Cooling performance is also predicted for temperature dependant coolant properties.

Numerical Study on Effects of Design Factors on Flow Characteristics of a Vane Pump (베인 펌프 설계인자 변화에 따른 내부 유동 해석)

  • Lee, Sang-Hyuk;Hur, Nahm-Keon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.24-31
    • /
    • 2007
  • In the present study, the effects of the design factors and operating conditions on flow characteristics of a vane pump for the automotive power steering system has been analyzed numerically. An unsteady moving mesh technique with cell expansion/contraction method is used to simulate the rotation of vanes with respect to stationary inlet and outlet. As a result, the flow characteristics of the flow rate and pressure rise across the vane pump were obtained. The numerical analyses for the various design factors such as number of vanes and thickness between the rotor and camring and for various operating conditions such as rotational speed and pressure difference between inlet and outlet were extensively performed. And the results were discussed in the paper.

A Numerical Analysis on the Effect of Parameters for the Flow Rate through the Tunnel with Jet Fan Ventilating System (제트 홴 방식 환기시스템을 사용하는 터널의 환기량에 영향을 주는 인자에 대한 수치해석 검토)

  • 김사량;김기정;허남건;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.567-574
    • /
    • 2002
  • In the present study, ventilation flow rates and pressure rises through a road tunnel are simulated numerically using CFD with the various conditions such as roughness height, swirl angle of jet fan, entrance and exit effect and hub to tip ratio. By using a modified wall function, friction factor can be predicted under 10% of error with respect to the Moody chart for the circular pipe flow and 15%, for the present tunnel. For more precise design, the effects of the swirl angle and hub to tip ratio of jet fan, which is not included in the theoretical equation of pressure rise by jet fan are necessary to be considered.

A Study on the Performance Improvement and Simplification of the Modulator for Vehicle Stability Control System (차량 안정성 제어 시스템의 모듈레이터 성능개선 및 단순화에 관한 연구)

  • 이종찬;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.84-93
    • /
    • 2004
  • This study carries out the performance improvement and simplification of hydraulic modulator that plays an important role in vehicle stability control systems. The mathematical models for each component of a modulator, such as pump, wheel cylinder, check and solenoid valve, accumulator, damper are derived in detail. All the mathematical models are combined to form a modulator system and implemented through a computer program, which can be controlled by a user friendly GUI. To verity the simulation, comparison between simulation and experiments has been made. After the verification of the validity of the simulation, the effects of the design parameters of the modulator on the wheel cylinder pressure is investigated. The results show that the modulator without MPA has advantage in early time pressure rise rate, and it can be simplified.

Thermal radiation and some physical combined effects on an asymmetric peristaltically vertical channel of nanofluid flow

  • Amira S. Awaad;Zakaria M. Gharsseldien
    • Advances in nano research
    • /
    • v.16 no.6
    • /
    • pp.579-591
    • /
    • 2024
  • This study explained the effects of radiation, magnetic field, and nanoparticle shape on the peristaltic flow of an Upper-Convected Maxwell nanofluid through a porous medium in an asymmetric channel for a better understanding of cooling and heating mechanisms in the presence of magnetic fields. These phenomena are modeled mathematically as a system of non-linear differential equations, that are solved under long-wavelength approximation and low Reynolds number conditions using the perturbation method. The results for nanofluid and temperature described the behavior of the pumping characteristics during their interaction with (the vertical position, thermal radiation, the shape of the nanoparticle, and the magnetic field) analytically and explained graphically. Also, the combined effects of thermal radiation parameters and some physical parameters on pressure rise, pressure gradient, velocity, and heat distribution are pointed out. Qualitatively, a reverse velocity appears with combined high radiation and Grashof number or combined high radiation and low volume flow rate. At high radiation, the spherical nanoparticle shape has the greatest effect on heat distribution.

Design of partial emission type liquid nitrogen pump

  • Lee, Jinwoo;Kwon, Yonghyun;Lee, Changhyeong;Choi, Jungdong;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.64-68
    • /
    • 2016
  • High Temperature Superconductor power cable systems are being developed actively to solve the problem of increasing power demand. With increases in the unit length of the High Temperature Superconductor power cable, it is necessary to develop highly efficient and reliable cryogenic pumps to transport the coolant over long distances. Generally, to obtain a high degree of efficiency, the cryogenic pump requires a high pressure rise with a low flow rate, and a partial emission type pump is appropriate considering its low specific speed, which is different from the conventional centrifugal type, full emission type. This paper describes the design of a partial emission pump to circulate subcooled liquid nitrogen. It consists of an impeller, a circular case and a diffuser. The conventional pump and the partial emission pump have different features in the impeller and the discharge flow passage. The partial emission pump uses an impeller with straight radial blades. The emission of working fluid does not occur continuously from all of the impeller channels, and the diffuser allows the flow only from a part of the impeller channels. As the area of the diffuser increases gradually, it converts the dynamic pressure into static pressure while minimizing the loss of total pressure. We used the known numerical method for the optimum design process and made a CFD analysis to verify the theoretical performance.

A Numerical Analysis and Experiment for Micro-Fans (축류 마이크로 홴의 전산해석 및 성능시험)

  • Cho, Jin-Soo;Pyun, Tae-Kyoon;Park, Wang-Sik;Chun, Chang-Kun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

Waterhammer in the Transmission Pipeline with an Air Chamber (에어챔버가 설치된 송수관로에서의 수격현상)

  • Kim, Gyeong-Yeop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.177-183
    • /
    • 2002
  • The field tests on the waterhammer were carried out in the pump pipeline system with an air chamber. The effects of the input variables and the design parameters for the air chamber were investigated by both the numerical calculations and the experiments. Because the waterhammer problems as a result of the pump power failure were the most important, these situations were carefully studied. Among the input variables used in the waterhammer analysis, the polytropic exponent, the discharge coefficient and the wavespeed had influence on the simulated results in that order, and were calibrated in comparison with the experimental results. As the initial air volume in a vessel increased, the period of waterhammer increased and the pressure variation decreased, resulting from the reduction of the rate of pressure change in the air chamber. Using smaller orifice in the bypass pipe, the pressure rise was suppressed in some degree and the pressure surge was dissipated more rapidly as time passed. The simulations were in fairly good agreement with the measured values until 1∼2 periods of waterhammer. Not only the maximum and minimum pressures in the pipe1ine but also those occurring times were reasonably predicted. The computer program developed in this study will be useful in designing the optimum parameters of an air chamber for the real pump pipeline system.

Korean Red Ginseng Protects Oxidative Injury Caused by Lead Poisoning

  • Park, Myoung-Soo;Cho, Eun-Jung;Lee, Sang-Ki;Lee, Eun-Ji;Lee, Dae-Sik;Lee, Kwon-Ho;Jeon, Byeong-Hwa
    • Journal of Ginseng Research
    • /
    • v.34 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • Lead (Pb) is a metal that is generally considered to be toxic to the cardiovascular system. Pb-exposed animals display the evidence of increased oxidative stress and hypertension. The current study was designed to examine whether Korean red ginseng (KRG) has protective effects against Pb-induced hypertension and oxidative stress in Pb-exposed rats. Male Sprague-Dawley rats were randomly assigned to Pb exposure or control groups. KRG was administered in drinking water at a concentration of 100 mg/kg/day; the control group received plain drinking water. Animals in the Pb-exposed groups were provided with drinking water containing 100 ppm Pb acetate for 12 weeks. Blood pressure, plasma glutathione, blood Pb concentration, and hematologic data, such as red blood cell quantity, were determined. Pb poisoning was assessed by measuring the blood Pb concentration. Pb exposure (100 ppm) for 12 weeks resulted in a marked rise in systolic blood pressure and blood Pb concentration, as well as a significant reduction in plasma glutathione levels and red blood cell quantity. Other measurements, such as heart rate, body weight, and white blood cell quantity, were unchanged. Treatment with KRG significantly lowered blood pressure, raised plasma glutathione and increased red blood cell numbers in Pb-exposed animals; it also had no effect on heart rate, body weight, or white blood cell quantity. However, the elevated blood Pb concentration was not reduced by treatment with KRG (100 mg/kg). Taken together, these data indicate that treatment with KRG in Pb-exposed animals can reduce oxidative stress and lower blood pressure, suggesting that KRG might be protective against Pb-exposed hypertension and oxidative stress.