• Title/Summary/Keyword: Pressure transducer

Search Result 329, Processing Time 0.027 seconds

An Experimental Study on Control System Performance of an Electro-Hydraulic Copying Machine (전기 유압식 모방절삭 기계 의 제어성능 에 관한 연구)

  • 윤지섭;조형석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.104-110
    • /
    • 1984
  • An electro-hydraulic copying system is developed and its performance is experimentally investigated. As compared with a mechanical hydraulic coping system, this system has a basic difference in that; (1) the stylus movement is converted into an electrical signal via a position transducer. (2)the actuator displacement is also measured by a position sensing element, which serves as a feedback signal. Since the system parameters affect the control performance, the response characteristics such as percentage overshoot, rise time, settling time and steady state error are experimentally obtained under variation of these variables. The system parameter include supply pressure, servo amplifier gain and feedback gain. The experimental result shows that the cutting tool follows a stylus input motion to a desirable accuracy. The implication of this result indicates that the developed system can enhance the copying accuracy of the conventionally used mechanical type of hydraulic copying system.

A Horn of Half-Wave Design for Ultrasonic Metal Welding (초음파 금속 용착용 반파장 혼의 설계)

  • Jang, Ho-Su;Park, Woo-Yeol;Park, Dong-Sam
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.76-81
    • /
    • 2012
  • Ultrasonic metal welding is one of the welding methods which welds metal by applying high frequency vibrational energy into specific area at constant pressure, avaliable in room temperature and low temperature. Ultrasonic metal welder is consisted of power supply, transducer, booster, and horn. Precise designing is required since each parts' shape, length and mass can affect driving frequency and vibration mode. This paper focused to horn design, its length L was set to 62mm by calculating vibration equation. By performing modal analysis with various shape variable b times integer, when length of b is 30mm the output was 39,599Hz at 10th mode. Also by performing harmonic response analysis, the frequency response result was 39,533Hz, which was similar to modal analysis result. In order to observe the designed horn's performance, about 4,000 voltage data was obtained from a light sensor and was analyzed by FFT analysis using Origin Tool. The result RMS amplitude was approximately 8.5${\mu}m$ at 40,000Hz, and maximum amplitude was 12.3${\mu}m$. Therefore, it was verified that the ultrasonic metal welding horn was optimally designed.

Characteristics of ZnO thin film for surface acoustic filters (표면탄성파 필터를 위한 ZnO 박막의 특성)

  • Kim, Young-Jin;Park, Wuk-Dong;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.45-50
    • /
    • 1995
  • The excellent c-axis oriented zinc oxide thin films were prepared by the RF magnetron sputtering method on glass substrates. Optimum fabrication conditions of the ZnO films were such that RF power, substrate temperature, and gas pressure of mixture Ar(50%):$O_{2}$(50%) were 150 W, $200^{\circ}C$, and 5 mTorr, respectively. In these conditions, the deposition rate was $310\;{\AA}/min$, and the resistivity of the film was $1{\times}10^6\;{\Omega}{\cdot}cm$. The ZnO film also showed high c-axis orientation and crystalinity according to XRD pattern and SEM photograph. A fabricated interdigital transducer generated 1st mode surface acoustic wave at 46.6 MHz and 2nd mode surface acoustic wave at 52.5 MHz. At the 1st mode, the phase velocity of surface acoustic wave and the electromechanical coupling coefficient were 2795 m/sec and 0.031 %, respectivly. At the 2nd mode, they were 3149 m/sec and 0.019 %. respectivly.

  • PDF

Acoustic Characteristics Analysis of Cylindrical Array for the Directional and Omni-directional mode Using the Boundary Element Method (경계요소법을 이용한 원통형 배열센서의 지향성/무지향성 모드에 대한 음향특성해석)

  • Lee, Jung-Min;Seo, Hee-Seon;Cho, Yo-Han;Baek, Kwang-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.9
    • /
    • pp.922-927
    • /
    • 2009
  • The transducers used in active sonar on surface ships are packed in a specific geometry in the array drum in order to meet the requirements such as the source level, directional beam pattern, etc. This paper describes the acoustic characteristics of the cylindrical array which is based on a 64 vertical staves arrangement, each stave composed 5 independent transducers. Firstly, the single transducer on the rigid baffle in the water is analyzed with the Finite Element Method. From the result of the FE analysis nodal velocities on the radiation surface is calculated and used with the boundary conditions of the transducers mounted on the array drum. Then the acoustic pressure is calculated in the field points using the Boundary Element Method and the other acoustic informations, the source level, beam pattern, near field and far-field distance, were acquired.

Studies on the pesticide amitraz-induced bradycardia

  • Kim, Hyeon-oh;Shin, Dong-ho;Nah, Seung-youl;Kim, Jae-ha;Kim, Sung-ho;Park, Hag-jae;Chung, Yeong-hee
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.4
    • /
    • pp.710-714
    • /
    • 1999
  • In veterinary medicine amitraz has been used as an insecticide to eliminate mites, lice, and ticks in dogs, cats, goats, swine and cattle. We performed the experiment on bradycardiac effect of arnitraz in rabbits. Under anesthetized with urethane (1g/kg, 25% w/v, SC), the femoral artery was cannulated by a polyvinyl tube which was connected with pressure transducer for continuous measurement of heart rate. Amitraz (0.5-2.5mg/kg, IV) reduced the heart rate in a dose-dependent manner. Pretreatment of yohimbine (2.0mg/kg) or atropine (2.0mg/kg and 4.0mg/kg) affected the response of amitraz but pretreatment of prazosin (0.5mg/kg) or propranolol (1.0mg/kg) did not. Moreover, the effect of amitraz was blocked by vagotomy. The result of our experiment suggest that amitraz may reduce the heart rate by increasing acetylcholine through activating vagal nerves and ${\alpha}_2$-adrenoceptors could be involved in activating vagal nerves.

  • PDF

Giant Piezoelectric Nanocomposites Integrated in Physically Responsive Field-effect Transistors for Pressure Sensing Applications

  • Tien, Nguyen Thanh;Trung, Tran Quang;Kim, Do-Il;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.550-551
    • /
    • 2012
  • Physically responsive field-effect transistors (physi-FETs), which are sensitive to physical stimuli, have been studied for decades. However, the primary issue of separating responses by sensing materials from interferences by other subcomponents in a FET transducer under global physical stimuli has not been completely resolved. Recent challenges of structural design and employing smart materials with a large electro-physical coupling effect for flexible physi-FETs still remain. In this article, we propose directly integrating nanocomposites of barium titanate (BT) nanoparticles (NPs) and highly crystalline poly(vinylidene fluoride-trifluoroethylene) (P(VDF-TrFE)) as gate dielectrics into flexible organic FETs to precisely separate and quantify tiny variations of remnant polarization caused by mechanical stimuli. Investigations under static stimuli resulted in first-reported giant-positive piezoelectric coefficients of d33 up to 960 pC/N, presumably due to significant contribution of the intrinsic piezoelectricity of BT NPs and P(VDF-TrFE) crystallites. This approach provides a general research direction, and not limited to physic-FETs.

  • PDF

An Ultrasonic Application with High Frequency for the Efficiency Elevation of the Hydrogen Fuel Production (On the Pole Interval and the Temperature) (수소연료 생산의 효율향상을 위한 고주파수 초음파 응용 (극간격과 온도 중심으로))

  • Song, Min-Geun;Son, Seung-Woo;Ju, Eun-Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • A Study on the application of ultrasonic with high frequency is carried out as a plan to rise the efficiency of the hydrogen fuel production in an electrolysis of water. KOH is selected as an electrolyte and concentrations are 0 %, 10 %, 20 %, and 30%. The solvent is city water. A measurable device of buoyancy by an electronic balance and a measurable device of voltage with a sensor of pressure are planned newly as a measuring device to measure the quantity of hydrogen production. An ultrasonic transducer with high frequency of 2 MHz is selected to give them the ultrasonic forcing. In results, it is clarified that ultrasonic influences the decrease of overpotential in the electrolytic solution. And basic data according to the pole interval and the temperature are obtained.

다목적실용위성 2호 추진시스템 비행모델 개발

  • Lee, Kyun-Ho;Han, Cho-Young;Yu, Myoung-Jong;Choi, Joon-Min
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.97-102
    • /
    • 2004
  • Propulsion System provides the required velocity change impulse for orbit transfer from parking orbit to mission orbit and three-axis vehicle attitude control impulse. KOMPSAT-2 propulsion system(PS) is an all-welded, monopropellant hydrazine system. The PS consists of the subassemblies and components such as Thrusters, Propellant Tank, Pressure Transducer, Propellant Filter, Latching Isolation Valves, Fill/Drain Valves, interconnecting propellant line assembly, and thermal hardwares for operation-environment control of the PS. This paper summarizes a development process of the liquid propulsion system from the design engineering up to the test and evaluation.

  • PDF

Study on Oriental Prescription for Medicinal Food Applications -Effects and Mechanism of Saengmaegsan on the Relaxation of Contracted Artery and Regional Cerebral Blood Flow- (한약처방을 활용한 Medicinal Food의 개발에 관한 연구 - 생맥산이 수축동맥의 이완과 국소뇌혈류량에 미치는 효과 및 기전 -)

  • Park Sung-Hye;Kim Woon-Ju
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.5
    • /
    • pp.606-612
    • /
    • 2005
  • This study was performed to provide basic data that predict the application of Saengmaegsan(SMS) as medicinal food. SMS has been used in oriental medicine for many years as a therapeutic agent for cerebral disease. We examined the effects of SMS on physiological function in isolated abdominal aorta and femoral artery from rabbit and measured the changes of regional cerebral hood flow(rCBF), which was continually monitored by laser-doppler flowmeter and pressure transducer in anesthetized adult Spargue-Dawley rats through the data acquisition system composed of MacLab and Macintosh computer. The contraction forces by injection of norephinephrine in isolated abdominal aorta and femoral artery were significantly decreased in each concentration of SMS treatment compared with control. rCBF was increased by SMS in a dose-dependent manner. These results suggest that SMS causes a diverse response of rCBF and arterial diameter. These mechanism in rCBF increase may be mediated by prostaglandis, cyclic GMP and adrenergic $\beta-receptor$. Also mechanism in artery contraction decrease is also mediated by prostaglandis and cyclic GMP. These results indicate that SMS can be nsed as a safe and clinically applicable as a supplementation of diet therapy for cerebral cardiovascular disease patients.

  • PDF

Study of Frequency Response Characteristics in Microphone Used by Optical Sensor

  • Yeom, Keong-Tae;Kim, Kwan-Kyu;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.128-133
    • /
    • 2008
  • In this paper, in order to analyze property of frequency response in microphone using optical sensor, acousto-optic sensor system has been implemented. The capacitance microphone and fiber-optic transmission path type fiber-optic microphone (FOM) have weaknesses in directivity, size, weight, and price. However suggested optical microphone can be constituted by cheap devices, so it has many benefits like small size, light weight, high directivity, etc. Head part of optical microphone which is suggested in this paper is movable back and forth by sound pressure with the attached reflection plate. Operating point has also been determined by measuring the response characteristics. The choosing the point, which has maximum linearity and sensitivity has changing the distance between optical head and vibrating plate. We measured the output of the O/E transformed signal of the optical microphone while frequency of sound signal is changed using sound measurement /analysis program, "Smaart Live" and "USBPre", which are based on PC, and compared the result from an existing capacitance microphone. The measured optical microphone showed almost similar output characteristics as those of the compared condenser microphone, and its bandwidth performance was about 4 kHz at up to 3 dB.