• Title/Summary/Keyword: Pressure relief

Search Result 273, Processing Time 0.024 seconds

The effects of active release technique on the gluteus medius for pain relief in persons with chronic low back pain

  • Tak, Sajin;Lee, Yongwoo;Choi, Wonjae;Lee, Gyuchang
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.27-30
    • /
    • 2013
  • Objective: Low back pain is a primary of source of dysfunction and economic costs. Gluteus medius muscle co-activation and activity pattern change caused the low back pain. Active release technique (ART) is a patented, non-invasive, soft tissue treatment process that both locates and breaks down the scar tissue and adhesions. The purpose of this study was to assess the effects on chronic low back pain using ART on gluteus medius so that suggest usable treatment method for treating chronic low back pain. Design: One group pretest-posttest design. Methods: Twelve patients with chronic low back pain were participated in this study. Subjects in ART group were received 2 times a week for 3 weeks treatments with either ART on gluteus medius muscle trigger points. Outcome measures were conducted by pain intensity with a pain visual analogue scale and pressure pain threshold on gluteus medius. Results: Completion of the intervention, the visual analogue scale was decreased in ART group (p<0.05). Also pressure pain threshold was decreased in ART group (p<0.05). Conclusions: Our results suggest that the response to ART may be usable to treat low back pain. ART was presented to reduce pain level of low back in people with chronic low back pain. Further study is required to management for low back pain due to gluteus medius and more ART study.

  • PDF

A Study on Oriental Medicine Hybrid Multi-cup Electric Cupping Contents using Vacuum Pressure (진공압을 이용한 한방 하이브리드 멀티 전동 부항 콘텐츠에 관한 연구)

  • Kim, Jong-Chan;Wei, Tung-Shuen;Ko, Jae-Sub;Choi, Heung-Kook;Tak, Myung-Ja;Kim, Cheeyong
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.11
    • /
    • pp.1363-1373
    • /
    • 2014
  • In this study, a hybrid multi-cup electric cupping system (HMECS) was proposed, based on the ancient cupping method. HMECS consisted of several cups that could be used simultaneously to treat different areas of the patient's body. Each cup was equipped with its own pump and pressure-monitoring system. Moreover, the vacuum pressure of the cups was controlled using fuzzy logic. Through automated control of the vacuum pressure, long-term relief of muscle tightness was achieved. To develop a scientific foundation for this alternative treatment, we compared the VAS(Visual Analog Scale) and ODI(Oswestry Disability Index) scores from conventional basic cupping to the VAS and ODI scores for our proposed HMECS. The improvement rate in the VAS and ODI scores using HMECS after three treatments was higher than that achieved by basic cupping. These results, combined with the convenience offered by enhanced IT capabilities, should increase the popularity of this device among an aging society, and facilitate the opportunity to further explore the potential of Oriental medical practices.

Subsea Responses to the BP Oil Spill in the Gulf of Mexico (멕시코만의 BP사 오일유출 해저 대책에 대한 분석)

  • Choi, Han-Suk;Lee, Seung-Keon;Do, Chang-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.90-95
    • /
    • 2011
  • On April 20, 2010, a well control event allowed hydrocarbon (oil and gas) to escape from the Macondo well onto Deepwater Horizon (DWH), resulting in an exploration and fire on the rig. While 17 people were injured, 11 others lost their lives. The fire continued for 36 hours until the rig sank. Hydrocarbons continued to flow out from the reservoir through the well bore and blowout preventer (BOP) for 87 days, causing an unprecedented oil spill. Beyond Petroleum (BP) and the US federal government tried various methods to prevent the oil spill and to capture the spilled oil. The corresponding responses were very challenging due to the scale, intensity, and duration of the incident that occurred under extreme conditions in terms of pressure, temperature, and amount of flow. On July 15, a capping stack, which is another BOP on top of the existing BOP, was successfully installed, and the oil spill was stopped. After several tests and subsea responses, the well was permanently sealed by a relief well and a bottom kill on September 19. This paper analyzes the subsea responses and engineering efforts to capture the oil, stop the leaking, and kill the subsea well. During the investigation and analysis of subsea responses, information was collected and data bases were established for future accident prevention and the development of subsea engineering.

A Study on Policy Support for Emergency Relief Grant for COVID-19 through Causal Loop Analyses (인과지도 분석을 통한 코로나-19의 소상공인 정책지원 연구)

  • Suh, Kyung-Do;Choi, Jung il;Choi, Pan-Am;Jung, Jaerim
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.5
    • /
    • pp.531-539
    • /
    • 2022
  • The government enforced policies such as social distancing and limiting business hours to prevent the spread of COVID-19. However, the impact of the long-term COVID-19 pandemic is causing more serious difficulties for small business owners. The government intended to relieve the business management pressure for small business owners by drawing up the COVID-19 emergency disaster relief funds. The funds provided temporary support for the small business owners, but the prolonged pandemic worsened the business management difficulties. Therefore, this study will apply fixes that fail and shifting the burden archetypes from the system archetype of system thinking for the exploratory deduction of policy measures as the policy leverage to effectively enhance the recovery of small business owners. In response to the situation, emergency financial aid for small business owners and support that can enhance the self-sustaining powers are required to heighten the recovery of small business owners.

Pneumatic circuit design and Performance test of Air balancer (에어밸런서 공압 회로의 설계 및 성능 실험)

  • Kim, D.S.;Bae, S.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.3
    • /
    • pp.20-24
    • /
    • 2006
  • Air balancer is a conveyance cargo-handling machine, used in assembly and process lines of car and machining industries. This can lift up an object, the weight of which is from 5 to 200 kg, and moves it to a position. As industrial technologies evolve, it is required to move an object and fit it into a specified position with greater accuracy, rather than performing simple tasks such as lifting objects up and down as conventional ones do. There is also a demand to handle an object with one hand, rather than with two hands,. Through designs of manifold unit for an air balancer function, pilot regulator unit to keep pressure constant, hand unit for an accurate load perception function, and air balancer circuit, this study enables everybody to work it with ease and convenience. Experiments and comparisons were conducted for the performance evaluation of the circuit.

  • PDF

Abnormal Operation Analysis of the Wolsong 2,3,4 Heat Transport System (월성 2,3,4호기 열수송계통의 비정상 운전 해석)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2016
  • The heat transport system transients of Wolsong 2,3,4 nuclear power plants were analysed during abnormal operating conditions. The compliance with requirements of AECB Regulatory Document R-77 for CANDU reactor was estimated. The analysis results showed that for each postulated accident the peak pressure values in the reactor headers are within the acceptance criteria given in ASME code requirements. The effect of LRV that is one of the overpressure protection device was very minor.

Repair of the Coarctation of the Aorta Using the Subclavian Artery as a Flap and Preservation of Arterial Blood Flow to the Left Arm (상지혈류를 보전한 쇄골하동맥피판 대동맥성형술)

  • 허동명
    • Journal of Chest Surgery
    • /
    • v.24 no.6
    • /
    • pp.625-630
    • /
    • 1991
  • From April 1990 through June 1990, three patients underwent subclavian flap aortoplasty for relief of the coarctation of the aorta. The age of the patients were 13 days, 7 months and 39 months and their weights were 3.3kg, 6.5kg, and 11kg, respectively. Two patients had persistence of the ductus arteriosus and all patients had associated intracardiac anomalies. We used the technique devised by Mendonca, namely, repair of the coarctation of the aorta using the subclavian artery as a flap and preservation of the arterial blood flow to the left arm. In one patient with long narrowing of isthmus, significant residual pressure gradient was remained by this technique and we added patch aortoplasty. There were no hospital deaths and follow-up over a one year period shows all patients in good condition.

  • PDF

Systemic-Pulmonary Shunts Using Microporous Expanded Polytetrafluoroethylene (Polytetrafluoroethylene 을 이용한 체-폐동맥 단락술)

  • Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.314-319
    • /
    • 1985
  • Nineteen patients with various types of cyanotic congenital heart disease underwent systemic-pulmonary artery shunts with a microporous polytetrafluoroethylene [PTFE] graft between September, 1983, and April, 1985. Age ranged from 3 months to 18 years, and seven of them were less than 12 months old. There were seventeen Great Ormond Street type of modified Blalock-Taussig shunts, and two central polytetrafluoroethylene shunt [ascending aorta-right pulmonary artery]. There was one postoperative death [1/19=5.3%] in a 10 Kg child born with pulmonary atresia and ventricular septal defect associated with patent ductus arteriosus. He had another anomaly of imperforated anus. Relief from cyanosis was achieved in other eighteen patients with variable degree. Eighteen survivors have been followed up from 1 month to 19 months. Clinical status, auscultation, oxygen partial pressure of arterial blood, and hemoglobin have been used to establish shunt patency in all survivors. By above criteria, all survivors have good patent shunt.

  • PDF

Test Results of Composite Cylinder Surface Temperature change between Pool Fire and Single Impinging Jet Flame Exposure Condition (전체 화염 및 단일 화염 노출 조건에서 복합재료 용기 표면 온도 변화 비교)

  • Lee, Jae-Hun;Hwang, Jun-Ho;Kim, Young-Seop;Kim, Hyo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.648-651
    • /
    • 2009
  • 탄소섬유강화플라스틱(CFRP:Carbon Fiber Reinforced Plastic)용기의 외부에 화재가 발생할 경우 함침된 수지(Resin)가 탄화되면서 자체 강도가 약화되고 충전된 가스가 외부 온도 상승에 따라 압력 상승이 발생하여 용기의 폭발로 이어지는 사고가 발생할 개연성이 높다. 화염 노출조건에서 복합재료 용기의 폭발을 방지하기 위하여 용기용 밸브에 내장된 온도감응식 압력안전장치(TPRD:Thermally activated Pressure Relief Device) 작동 성능을 검증하기 위한 방법으로 화염실험(Bonfire test)를 실시하고 있으나, 개방 공간에서 실시되는 이 실험은 표면 온도 변화가 매우 크게 발생하여 실험에 대한 재현성(Reproducibility)에 의문이 제기되고 있다. 따라서, 표면 온도를 일정하게 유지하기 위한 실험 방법의 개선이 필요하다. 본 연구에서는 경유+heptane을 이용한 전체 화염에 노출되는 경우와, 천연가스를 이용한 단일화염에 노출되는 경우의 실험 결과 비교를 통하여 화염 노출 표면 온도를 일정하게 유지하기 위한 가열 방법의 타당성을 검토하였다. 또한, 복합재료 라이너(Liner)의 온도 변화 비교를 통하여 집중화염 노출 조건에서 열전달 특성을 알아보았다.

  • PDF

Unstable Angina Pectoris after Lumbar Epidural Blockade in a Herpes Zoster Patient with Chronic Stable Angina Pectoris -A case report- (만성 안전형 협심증을 가진 대상포진 환자에서 요부 경막외 차단 후 발생한 불안전형 협심증 -증례 보고-)

  • Lee, Jun-Hak;Yun, Chae-Sik;Chung, Eun-Bae;Lee, Ki-Nam;Moon, Jun-Il
    • The Korean Journal of Pain
    • /
    • v.11 no.1
    • /
    • pp.146-149
    • /
    • 1998
  • Herpes zoster is a viral disease characterized by skin rash and persistent pain. Early treatment with epidural analgesia provides very effective pain relief and reduces the incidence of postherpetic neuralgia. However, epidural analgesia in elderly, deliberated or hypovolemic patients may complicate circulatory depression such as hypotension and bradycardia. Even if temporary, a major decrease in blood pressure may decrease coronary blood flow of patients with arteriosclerosis and ischemic accident may occur. We experienced a case of unstable angina pectoris after lumbar epidural blockade in a herpes zoster patient with chronic stable angina pectoris.

  • PDF