• Title/Summary/Keyword: Pressure pulse parameter

Search Result 51, Processing Time 0.025 seconds

The quantitative study on the Renying·Qi mouth comparison pulse diagnosis (인영(人迎)·기구비교맥법(氣口比較脈法)의 정량화(定量化)에 관(關)한 연구(硏究))

  • Cho, Myung-Rae;Kim, Moo-Shin;Ryu, Choong-Ryul;Choi, Chan-Hun;Jang, Kyeong-Seon;So, Cheol-Ho;Park, Young-Dae
    • Journal of Acupuncture Research
    • /
    • v.19 no.2
    • /
    • pp.149-163
    • /
    • 2002
  • Objective : We have studied literatures of Renying Qi mouth comparison pulse diagnosis theory and distinguished the excess, deficiency and quick-temper of pulse as the measurement parameter of Renying Qi mouth pulse diagnosis. Methods : We have acquired pulse signals of Renying Qi mouth by using diagnostic equipment of Renying Qi mouth pulsation and estimated reappearance of pulse signals. Results : 1. The measurement parameter of Renying Qi mouth pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Renying Qi mouth. 2. When we acquired the pulse singals of Renying Qi mouth by using diagnostic equipment, the property, measuring area, bias pressure, contact or adhesion state of the sensor are considered. 3. As getting the pulse signal of Renying Qi mouth, the sensor of a sound detective mode is effective. 4. The diagnostic equipment of Renying Qi mouth pulse is assessed as being significant reappearance.

  • PDF

A Case Study of Six Sigma Project for Improving method of measuring pulse wave (6시그마 기법을 통한 안정된 맥파측정 프로세스 설계)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.85-92
    • /
    • 2006
  • Pulse is one of the basic diagnostic information of TKM(Traditional Korean Medicine). To quantify and standardize pulse diagnosis, we had collected an amount of clinical data from May 2005 by using newly developed pulse analyzer. But there were many noises in pulse wave according to measuring method, environment, operator and condition of patient. So some data can’t be included for analyzing diagnosis. To reduce noises from measuring pulse and to collect reliable pulse wave data, we made the process map of measuring method and applied six sigma project. With this we can improved the method of measuring pulse wave in collecting clinical data. The project follows a disciplined process of five macro phases: define, measure, analyze, improve and control (DMAIC). A process map and C-E diagram are used to identify process input and output variables. The major input variables are selected by using C&E matrix, and process map is developed by analyzing input variables. And the optimum process conditions are going to be controled to avoid in increasing loss of collecting pulse wave data.

  • PDF

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

The Microstructures and Properties of Surface Layer on the Tool Steel Formed by Ion Nitriding -Effects of Process Parameter- (마이크로 펄스 플라즈마 질화에 의해 생성된 금형 공구강의 표면층에 관한 연구 -공정 변수의 영향-)

  • Lee, J.S.;Kim, H.G.;You, Y.Z.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.1
    • /
    • pp.8-16
    • /
    • 2001
  • The effects of gas composition, pressure, temperature and time on the case thickness, hardness and nitride formation in the surface of tool steels(STD11 and STD61) have been studied by micro-pulse plasma nitriding. External compound layer and internal diffusion layer and the diffusion layer were observed in the nitrided case of tool steels. The relative amounts and kind of phases formed in the nitrided case changed with the change of nitriding conditions. Generally, only nitride phases such as ${\gamma}(Fe_4N)$, ${\varepsilon}(Fe_{2-3}N)$, or $Cr_{1.75}V_{0.25}N_2$ phases were detected in the compound layer, while nitride and carbide phases such as ${\varepsilon}-nitride(Fe_{2-3}N)$, $(Cr,Fe)_{\gamma}C_3$ or $Fe_3C$ were detected in the diffusion layer by XRD analysis. The thickness of compound layer increased with the increase of nitrogen content in the gas composition. Maximum case depth was obtained at gas pressure of 200Pa.

  • PDF

The influence of processing condition and assistance gas in microhole machining of $Al_2O_3$ ceramics ($Al_2O_3$ 세라믹의 미세구멍 가공시 가공조건과 보조가스가 미치는 영향)

  • 이광길
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.5
    • /
    • pp.115-120
    • /
    • 1999
  • This research is a described result of experimental for the parameter's effecting the microhole machining by Nd-Yag laser, The parameters are energy, pulse interval time a kin of assisting gas and its pressure. The result reveals that parameter value of energy 0.08J, pulse 20Hz, interval time of 300 microseconds could be a good machining condition to make upper microhoel that is the diameter range of 50-70${\mu}{\textrm}{m}$. At tat time the assistant gas such air, $O_2$, Ar $N_2$, was appelied. Assistant gas of air makes heat affected zone enlarge due to burning of material surface. Also it makes microhole irregular and damageable. Because of refusion caused by chemical reaction with $Al_2O_3$ ceramic material . The $O_2$(99.9%) has good characteristics to get good drilling and smooth surface on pressure of 0.2kgf/$\textrm{cm}^2$ but it is expensive. Ar, $N_2$ make material crack and burnning and proved that to be unappropriate but, Ar was a better than $N_2$.

  • PDF

Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation (동맥경화 평가를 위한 연령별 맥파 주요인자 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Soo-Byeong;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

Ultrasonic Evaluation of Interfacial Stiffness for Nonlinear Contact Surfaces

  • Kim, Noh-Yu;Kim, Hyun-Dong;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.504-511
    • /
    • 2008
  • This paper proposes an ultrasonic measurement method for measurement of linear interfacial stiffness of contacting surface between two steel plates subjected to nominal compression pressures. Interfacial stiffness was evaluated by using shear waves reflected at contact interface of two identical solid plates. Three consecutive reflection waves from solid-solid surface are captured by pulse-echo method to evaluate the state of contact interface. A non-dimensional parameter defined as the ratio of their peak-to-peak amplitudes are formulated and used to calculate the quantitative stiffness of interface. Mathematical model for 1-D wave propagation across interfaces is developed to formulate the reflection and transmission waves across the interface and to determine the interfacial stiffness. Two identical plates are fabricated and assembled to form contacting surface and to measure interfacial stiffness at different states of contact pressure by means of bolt fastening. It is found from experiment that the amplitude of interfacial stiffness is dependent on the pressure and successfully determined by employing pulse-echo ultrasonic method without measuring through-transmission waves.

A Study on Physiological Parameter, Physical Health Status, and Health Perception in the Elderly (노인의 생리적 지수와 신체건강 상태, 건강지각과의 관계연구)

  • Han, Ae-Kyung
    • Korean Journal of Adult Nursing
    • /
    • v.16 no.3
    • /
    • pp.460-469
    • /
    • 2004
  • Purpose: The purpose was to investigate the physiological parameter and physical health status and health perception in the elderly, and to find the correlation between these variables. The subjects were 139 in Kyungi senior center. Method: The instruments for this study were physiological parameters, which were composed of vital capacity, blood pressure, pulse oxygenation, hand grip power, body fat and physical health status scale developed by researcher, and health perception scale developed by Ware(1976). The data were analyzed by the SPSS-PC 11.0 version. Results: 1) 7.9% of subjects were included in abnormal range of vital capacity, 40.3% were systolic hypertension and 11.5% were diastolic hypertension. And 92.1% were included in normal range of pulse oxygenation, 79.8% were weakened hand grip power, and 10.1% of subjects were included in normal range of body fat. 2) The total mean score of the physical health status was 26.34 of a possible maximum score of 45. The physical health status score of women was lower than man's. 3) The mean score of man's health perception was 24.52 and women's was 20.39 of a possible maximum score of 44. 4) There was a significant positive correlation between hand grip power and physical health status(r=.28, p=.001). And a significant correlation between physical health status and health perception was found (r=.24, p=.004). Conclusion: It is concluded that the blood pressure, hand grip power and body fat among the physiological parameters of elderly subjects in Kyungi senior center were included in abnormal range. The factors were related life style. therefore, it is suggested that the health education to change life style for the elderly is needed.

  • PDF

A Study on Arterial Characterization using Finger-Toe Index (FTI) (지첨-족지 지수에 의한 동맥 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.777-785
    • /
    • 2007
  • In this paper, Finger-Toe Index (FTI) is proposed as an analytic parameter for the characterization of arterial vessel. Different from the currently being employed pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels, the proposed FTI uses the ratio of the shorter of the two up-stroke time of PPG from fingers ($UT_{finger}$) and that of PPG (Photoplethysmography) from toes ($UT_{toe}$). To verify the usefulness of the proposed method, Finger-Toe Indexes were derived from the volume pulse waves acquired from 50 people under examination aged from 12 to 81 years old, and they were then compared with blood pressure ankle-brachial index (ABI). It was successfully demonstrated that the arterial stiffness can be estimated with respect to age and FTI is more strongly correlated with the pulse transit time than ABI. From the regression analysis, we also found that FTI has significant correlation PWV for a quantitative index of arterial stiffness and provides more accurate information than ABI for the characterization of arterial vessel.

Estimation of Nonlinear Parameter in Water - saturated Sandy Sediment by using Difference Frequency Acoustic wave (수중 모래 퇴적물에서 차 주파수 음파를 이용한 비선형 변수 추정)

  • Kim Byoung-Nam;Lee Kang Il;Yoon Suk Wang;Choi Bok Kyung
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.429-432
    • /
    • 2004
  • Nonlinear acoustic responses of water-saturated sediments are very important to understand nonlinear phenomena of gassy ocean sediments. Especially, the second harmonic, the sum and the difference frequency acoustic waves in water-saturated sediments can provide practical criteria to estimate the nonlinear parameter of gassy sediments. In this paper, the difference frequency acoustic wave in water-saturated sandy sediment was observed in a water tank experiment with a pulse transmission technique. Its pressure level was 12 dB higher than the background noise level at a maximum undistorted driving pressure of source acoustic transducer. The experimental results were compared with a theoretical estimation of the parametric acoustic array. The nonlinear parameter of water-saturated sandy sediment was also estimated as 73 with their comparison. This value can be utilized as the background information to estimate gas void fraction in the water-saturated gassy sandy sediment.

  • PDF