• Title/Summary/Keyword: Pressure gradient

Search Result 864, Processing Time 0.029 seconds

Evaluation of Pretreatment Moisture Content and Fixation Characteristics of Treated Wood for Pressure Treatment of Japanese Red Pine and Japanese Larch Skin Timber with ACQ, CUAZ and CuHDO (소나무와 낙엽송 스킨팀버의 ACQ, CUAZ, CuHDO 가압처리를 위한 처리용 목재의 적정 함수율 및 처리목재의 정착 특성 평가)

  • Choi, Yong-Seok;Oh, Se-Min;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.481-489
    • /
    • 2011
  • This study was conducted to evaluate the pressure treatment characteristics of Japanese red pine and Japanese larch skin timber with ACQ-2, CUAZ-2 and CuHDO-1. The effect of moisture content (MC) on preservative treatability was investigated for Japanese red pine sapwood and Japanese larch heartwood, and fixation characteristics of CCA alternatives was also evaluated. Japanese red pine sapwood, which was dried below 30 percent MC, was fully penetrated with preservatives, and minimum requirement of preservative retention for the hazard class H3 was achieved. Through measuring preservative retention gradient in Japanese red pine sapwood, it was confirmed that the retention gradient of CuHDO-1 was steeper than that of both ACQ-2 and CUAZ-2. In particular, it was intensified at a higher MCs of wood samples (25∼30%). Japanese larch heartwood did not meet the minimum requirement of penetration and retention for the hazard class H3 over the range of pretreatment MCs tested. With presteaming under $121^{\circ}C$ for 12 hours, the treatability of Japanese larch heartwood was enhanced to meet the minimum requirement for the hazard class H3. The fixation rate of copper was much more faster under drying condition compared with nondrying condition; more than 95% of copper were fixed in 3~6 days and 1 day under drying conditions in Japanese red pine sapwood and Japanese larch heartwood, respectively. After 3-week fixation period at ambient temperature, the amount of mobile copper in treated wood sample that remains available for leaching from treated wood was the highest in the wood samples treated with ACQ-2, followed by CuHDO-1 and CUAZ-2. It was proportional to the amount of copper in treating solution.

Thrombolytic Therapy for Thrombosis of Prosthetic Mitral Valve - A Case Report - (인공 승모판막에 생긴 혈전의 혈전용해 치료 - 1례 보고 -)

  • Kang, Shin-Kwang;Kim, Si-Wook;Won, Tae-Hee;Ku, Kwan-Woo;Na, Myung-Hoon;Yu, Jae-Hyun;Lim, Seung-Pyung;Lee, Young;Jeong, Jin-Ok
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.826-830
    • /
    • 2002
  • Prosthetic valve thrombosis(PVT) may be a life-threatening complication requiring prompt intervention. This is a case report of thrombolytic therapy for thrombosis of prosthetic mitral valve. A 47 year-old male admitted to the emergency room for abrupt onset of dyspnea. He had undergone mitral valve replacement(On-Ⅹ valve, 29mm) for mitral stenosis 8 months ago. The patient's international normalized ratio(INR) on admission was 1.09. The mechanical clicks were muffled and rales were heard in both lung fields. A transesophageal echocardiography(TEE) revealed prosthetic valve thrombosis with increased transvalvular pressure gradient(34 mmHg). The patient's condition needed to intubation for mechanical ventilation due to hemodynamic compromise, however his wife and relatives refused the surgical intervention due to financial problems. The patient was transferred to the cardiac care unit and we decided to perform thrombolytic therapy. A bolus of 1,500,000 IU of urokinase was given, followed by a drip of 1,500,000 IU for 1 hour. The patient did not improved hemodynamically; therefore, we gave 100 mg of tissue plasminogen activator(t-PA) for over 2 hours. During that time mechanical clicks were audible and hemodynamics of the patient improved progressively. A TEE showed disappearance of thrombus and decreased pressure gradient(1.7 mmHg) after 6 hours of thrombolytic therapy. The patient was recovered without any neurologic sequale and was discharged with administration of warfarin.

The role of porous graphite plate for high quality SiC crystal growth by PVT method (고품질 4H-SiC 단결정 성장을 위한 다공성 흑연 판의 역할)

  • Lee, Hee-Jun;Lee, Hee-Tae;Shin, Hee-Won;Park, Mi-Seon;Jang, Yeon-Suk;Lee, Won-Jae;Yeo, Im-Gyu;Eun, Tai-Hee;Kim, Jang-Yul;Chun, Myoung-Chul;Lee, Si-Hyun;Kim, Jung-Gon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.2
    • /
    • pp.51-55
    • /
    • 2015
  • The present research is focused on the effect of porous graphite what is influenced on the 4H-SiC crystal growth by PVT method. We expect that it produces more C-rich and a change of temperature gradient for polytype stability of 4H-SiC crystal as adding the porous graphite in the growth cell. The SiC seeds and high purity SiC source materials were placed on opposite side in a sealed graphite crucible which was surrounded by graphite insulator. The growth temperature was around $2100{\sim}2300^{\circ}C$ and the growth pressure was 10~30 Torr of an argon pressure with 5~15 % nitrogen. 2 inch $4^{\circ}$ off-axis 4H-SiC with C-face (000-1) was used as a seed material. The porous graphite plate was inserted on SiC powder source to produce a more C-rich for polytype stability of 4H-SiC crystal and uniform radial temperature gradient. While in case of the conventional crucible, various polytypes such as 6H-, 15R-SiC were observed on SiC wafers, only 4H-SiC polytype was observed on SiC wafers prepared in porous graphite inserted crucible. The defect level such as MP and EP density of SiC crystal grown in the conventional crucible was observed to be higher than that of porous graphite inserted crucible. The better crystal quality of SiC grown using porous graphite plate was also confirmed by rocking curve measurement and Raman spectra analysis.

Extent of Subprosthetic Pannus after Aortic Valve Replacement: Changes Over Time and Relationship with Echocardiographic Findings (대동맥판막치환술 후 발생한 판막하 판누스(Pannus): 시간에 따른 변화 및 심초음파 소견)

  • Mi Yeon Park;Hyun Jung Koo;Hojin Ha;Joon-Won Kang;Dong Hyun Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1151-1163
    • /
    • 2020
  • Purpose This study aimed to evaluate changes of subprosthetic pannus on cardiac CT and determine its relationship to echocardiographic findings in patients with mechanical aortic valve replacement (AVR). Materials and Methods Between April 2011 and November 2017, 17 AVR patients (56.8 ± 8.9 years, 12% male) who showed pannus formation on CT and had undergone both follow-up CT and echocardiography were included. The mean interval from AVR to the date of pannus detection was 10.5 ± 7.1 years. In the initial and follow-up CT and echocardiography, the pannus extent and echocardiographic parameters were compared using paired t-tests. The relationship between the opening angle of the prosthetic valve and the pannus extent was evaluated using Pearson correlation analysis. Results The pannus extent was significantly increased on CT (p < 0.05). The peak velocity (3.9 ± 0.8 m/s vs. 4.2 ± 0.8 m/s, p = 0.03) and mean pressure gradient (36.4 ± 15.5 mm Hg vs. 42.1 ± 15.8 mm Hg, p = 0.03) were significantly increased. The mean opening angles of the mechanical aortic leaflets were slightly decreased, but there was no statistical significance (73.1 ± 8.3° vs. 69.4 ± 12.1°, p = 0.12). The opening angle of the prosthetic leaflets was inversely correlated with the pannus extent (r = -0.57, p < 0.001). Conclusion The pannus extent increases over time, increasing transvalvular peak velocity and the pressure gradient. CT can be used to evaluate the pannus extent associated with hemodynamic changes that need to be managed by surgical intervention.

Conceptions of Secondary School Science Teachers on Some Concepts of Atmosphere and Ocean (대기와 해양의 몇 개념들에 대한 중·고등학교 과학교사의 개념)

  • Kook, Dong-Sik
    • Journal of the Korean earth science society
    • /
    • v.25 no.6
    • /
    • pp.402-408
    • /
    • 2004
  • The purpose of this study is to investigate various conceptions of secondary school earth science teachers on some concepts in secondary school earth science courses; wind in cyclone, western intensification of ocean current, westerly wave, greenhouse effect, ozone layer and atmospheric pressure. The subject is 26 in-service teachers of earth science teachers. The results were analyzed on the view of teaching sources for earth science teachers. The results show that earth science teachers have also various misconceptions on some concepts selected in this study. A number of partial understandings were found that were not enough to apply to teaching concepts. Those misconceptions were related to gradient wind on wind in cyclone and frictional force, related to earth rotation on western intensification of ocean current, related to angular momentum conservation and related to the roles of westerly wave. And misconceptions on greenhouse effect are related to main role of greenhouse effect gases, related to sources of ozone gas and phenomenons by atmospheric pressure. The various understanding types found in this study could be apply to teach the selected concepts in secondary school earth science course.

Short and Intermediate Term Results of the ATS Heart Valve Replacement (ATS 인공 심장 판막의 단기 및 중기 임상성적)

  • Lim, Chang-Young;Moon, Seung-Chul;Yang, Jin-Young;Koo, Won-Mo;Kim, Dae-Sig;Lee, Gun;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

Nonlinear Analysis of Nuclear Reinforced Concrete Containment Structures under Accidental Thermal Load and Pressure (온도 및 내압을 받는 원자로 철근콘크리트 격납구조물의 비선형해석)

  • Oh, Byung Hwan;Lee, Myung Gue
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.403-414
    • /
    • 1994
  • Nonlinear analysis of RC containment structure under thermal load and pressure is presented to trace the behaviour after an assumed LOCA. The temperature distribution varying with time through the wall thickness is determined by transient finite element analysis with the two time level scheme in time domain. The layered shell finite elements are used to represent the containment structures in nuclear power plants. Both geometric and material nonlinearities are taken into account in the finite element formulation. The constitutive relation of concrete is modeled according to Drucker-Prager yield criteria in compression. Tension stiffening model is used to represent the tensile behaviour of concrete including bond effect. The reinforcing bars are modeled by smeared layer at the location of reinforcements accounting elasto-plastic axial behaviors. The steel liner model under Von Mises yield criteria is adopted to represent elastic-perfect plastic behaviour. Geometric nonlinearity is formulated to consider the large displacement effect. Thermal stress components are determined by the initial strain concept during each time step. The temperature differential between any two consecutive time steps is considered as a load incremental. The numerical results from this study reveal that nonlinear temperature gradient based on transient thermal analysis will produces excessive large displacement. Nonlinear behavior of containment structures up to ultimate stage can be traced reallistically. The present study allows more realistic analysis of concrete containment structures in nuclear power plants.

  • PDF

Comparison of Message Passing Interface and Hybrid Programming Models to Solve Pressure Equation in Distributed Memory System (분산 메모리 시스템에서 압력방정식의 해법을 위한 MPI와 Hybrid 병렬 기법의 비교)

  • Jeon, Byoung Jin;Choi, Hyoung Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.191-197
    • /
    • 2015
  • The message passing interface (MPI) and hybrid programming models for the parallel computation of a pressure equation were compared in a distributed memory system. Both models were based on domain decomposition, and two numbers of the sub-domain were selected by considering the efficiency of the hybrid model. The parallel performances for various problem sizes were measured using up to 96 threads. It was found that in addition to the cache-memory size, the overhead of the MPI communication/OpenMP directives affected the parallel performance. For small problems, the parallel performance was low because the percentage of the overhead of the MPI communication/OpenMP directives increased as the number of threads increased, and MPI was better than the hybrid model because it had a smaller communication overhead. For large problems, the parallel performance was high because, in addition to the cache effect, the percentage of the communication overhead was relatively low compared to that for small problems, and the hybrid model was better than MPI because the communication overhead of MPI was more dominant than that of the OpenMP directives in the hybrid model.

Postoperative Outcomes of Mitral Valve Repair for Mitral Restenosis after Percutaneous Balloon Mitral Valvotomy

  • Lee, Ji Seong;Chee, Hyun Keun;Kim, Jun Seok;Song, Myong Gun;Park, Jae Bum;Shin, Je Kyoun
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.328-334
    • /
    • 2015
  • Background: There have been a number of studies on mitral valve replacement and repeated percutaneous mitral balloon valvotomy for mitral valve restenosis after percutaneous mitral balloon valvotomy. However, studies on mitral valve repair for these patients are rare. In this study, we analyzed postoperative outcomes of mitral valve repair for mitral valve restenosis after percutaneous mitral balloon valvotomy. Methods: In this study, we assessed 15 patients (mean age, $47.7{\pm}9.7years$; 11 female and 4 male) who underwent mitral valve repair between August 2008 and March 2013 for symptomatic mitral valve restenosis after percutaneous mitral balloon valvotomy. The mean interval between the initial percutaneous mitral balloon valvotomy and the mitral valve repair was $13.5{\pm}7years$. The mean preoperative Wilkins score was $9.4{\pm}2.6$. Results: The mean mitral valve area obtained using planimetry increased from $1.16{\pm}0.16cm^2$ to $1.62{\pm}0.34cm^2$ (p=0.0001). The mean pressure half time obtained using Doppler ultrasound decreased from $202.4{\pm}58.6ms$ to $152{\pm}50.2ms$ (p=0.0001). The mean pressure gradient obtained using Doppler ultrasound decreased from $9.4{\pm}4.0mmHg$ to $5.8{\pm}1.5mmHg$ (p=0.0021). There were no early or late deaths. Thromboembolic events or infective endocarditis did not occur. Reoperations such as mitral valve repair or mitral valve replacement were not performed during the follow-up period ($39{\pm}16months$). The 5-year event-free survival was 56.16% (95% confidence interval, 47.467-64.866). Conclusion: On the basis of these results, we could not conclude that mitral valve repair could be an alternative for patients with mitral valve restenosis after percutaneous balloon mitral valvotomy. However, some patients presented with results similar to those of mitral valve replacement. Further studies including more patients with long-term follow-up are necessary to determine the possibility of this application of mitral valve repair.

Numerical Simulation of Solitary Wave Run-up with an Internal Wave-Maker of Navier-Stokes Equations Model (내부조파기법을 활용한 Navier-Stokes 방정식 모형의 고립파 처오름 수치모의)

  • Ha, Tae-Min;Kim, Hyung-Jun;Cho, Yong-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.9
    • /
    • pp.801-811
    • /
    • 2010
  • A three-dimensional numerical model called NEWTANK is employed to investigate solitary wave run-up with an internal wave-maker on a steep slope. The numerical model solves the spatially averaged Navier-Stokes equations for two-phase flows. The LES (large-eddy-simulation) approach is adopted to model the turbulence effect by using the Smagorinsky SGS (sub-grid scale) closure model. A two-step projection method is adopted in numerical solutions, aided by the Bi-CGSTAB (Bi-Conjugate Gradient Stabilized) method to solve the pressure Poisson equation for the filtered pressure field. The second-order accurate VOF (volume-of-fluid) method is used to track the distorted and broken free surface. A solitary wave is first internally generated and propagated over a constant water depth in the three-dimensional domain. Numerically predicted results are compared with analytical solutions and numerical errors are analyzed in detail. The model is then applied to study solitary wave run-up on a steep slope and the obtained results are compared with available laboratory measurements.