• 제목/요약/키워드: Pressure field

검색결과 3,775건 처리시간 0.037초

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 The 7th Summer Workshop of the Membrane Society of Korea
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

70 MPa급 인공암반 내 실대형 쉴드TBM 굴진실험을 통한 굴진율 모델 및 활용방안 제안 (Development of a TBM Advance Rate Model and Its Field Application Based on Full-Scale Shield TBM Tunneling Tests in 70 MPa of Artificial Rock Mass)

  • 김정주;김경열;류희환;정주환;홍성연;조선아;배두산
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권3호
    • /
    • pp.305-313
    • /
    • 2020
  • 전력송전을 위한 터널식 전력구는 점차 시공실적이 증가하고 있는 추세이며, 해저 및 대심도 등 시공환경이 어려운 구간의 건설도 증가하고 있다. 이에 소단면 쉴드TBM의 효율적 운영을 위해 굴진율 및 설계모델이 필요하다. 그러나, 제한된 지반조사 회수 및 굴착면 맵핑으로 인하여 암반특성과 굴진데이터를 정확히 매칭시켜 상호간 상관관계 및 굴진율 모델을 도출하는데 어려움이 있다. 이에 소단면 쉴드TBM에 적합한 굴진율 및 설계모델을 제시하기 위하여 커터헤드의 직경이 3.56 m인 실험용 EPB 쉴드TBM을 제작하고, 총 부피 87.5 ㎥인 인공암반 내에서 총 19번의 실대형 굴진실험을 수행하였다. 본 실험은 70MPa의 균질한 암반강도에서 수행되었기 때문에 운전변수인 추력과 커터헤드의 RPM에 따른 굴진율과 기계데이터간 상관관계를 효율적으로 분석할 수 있으며, 실제 굴착메커니즘과 동일하기 때문에 도출된 압입깊이와 토크값은 활용성이 높다. 본 연구를 통해 디스크커터 당 연직력과 압입깊이의 상관관계 및 연직력과 회전력의 상관관계를 도출하였다. 이러한 상관관계들을 이용하여 70 MPa급 암반에 대해 굴진율 예측과 TBM 설계가 가능할 것으로 판단한다. 또한, 인공암반의 RQD가 100%로 현장적용에 대한 한계점에 대해 FPI의 개념을 도입하여 굴진율 모델의 활용성을 증대시키고자 하였다.

전남 해안 LPG 저장공동 유출수와 주변 지하수의 수질특성 (Characteristics of Seepage Water and Groundwater in a Coastal LPG Storage Cavern of Jeonnam)

  • 이진용;최미정;김현중;조병욱
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권4호
    • /
    • pp.33-44
    • /
    • 2009
  • LPG를 저장하는 지하공동의 수장막 시스템은 고압의 가스가 공동 밖으로 새어나가지 못하도록 원활한 지하수의 흐름과 안정적인 지하수두 유지가 필수적이다. 본 연구에서는 전남 여수 LPG공동의 유출수 및 주변 지하수의 수질특성을 파악하기 위하여 2007년 2월, 5월, 8월, 10월에 걸쳐 시료채취, 현장측정 및 실내 수질분석을 실시하였다. 현장 측정 결과 pH는 약산성에서 중성으로 나타났고 10월로 갈수록 증가하는 경향을 나타내었다. 전기전도도는 소금적치장과 인접한 관정의 경우 $10.47{\sim}38.50\;mS/cm$로 매우 높게 나타났다. 용존산소는 $0.20{\sim}8.74\;mg/L$로 매우 넓은 범위를 보였고, 산화환원전위는 평균 159 mV로 비교적 산화환경임을 나타냈다. 또 $Fe^{2+}$, $Mn^{2+}$의 농도는 대부분 3 mg/L 미만으로 나타났다. 수질유형은 유출수의 경우 4차례 모두 Na-Cl type로 나타났으나 지하수의 경우 소금적치장 인접 관측정은 Na-Cl type으로 높은 TDS를 보였다. 다른 지하수 관측정은 전형적인 $Ca-HCO_3$ type으로 나타났다. 미생물 분석결과 호기성세균의 수가 $573{\sim}39,520\;CFU/mL$로 비교적 높게 검출되었다. 본 연구에서 수리화학 및 미생물학적 특성을 분석한 결과 지하수와 유출수는 여수 저장공동의 운영에 있어서 큰 문제를 일으키지 않을 것으로 사료된다. 그러나 미생물 증식의 제어와 수리적 안정성을 유지하기 위해서는 지속적인 모니터링이 요구된다.

절리 암반의 수리지질 및 불연속면 특성 간 상관분석을 통한 그라우팅 계획 수립의 개선 방안 (Grouting Improvement through Correlation Analysis of Hydrogeology and Discontinuity Factors in a Jointed Rock-Mass)

  • 백광민;장성간;정성우;양민준
    • 지질공학
    • /
    • 제34권2호
    • /
    • pp.279-294
    • /
    • 2024
  • 댐은 대규모 토목 구조물로서 안전한 운영을 위해 기초지반의 누수를 차단하고 추가적인 재해를 방지하기 위하여 암반 그라우팅에 대한 체계적인 접근 및 이해가 필요하다. 국내에서는 암반 그라우팅 계획에 있어 현장 기술자의 경험과 유사 사례에 의존하는 경향이 있으며, 보다 신뢰성 있는 그라우팅 계획을 위해 (토목 or 공학적) 이론과 (현장 or 지반) 조사결과를 바탕으로 한 개선방안이 필요한 실정이다. 암반에서 시행하는 그라우팅은 대부분 수리지질 및 불연속면 인자들(RQD, Js, Lu, SPI)에 의해 가장 큰 영향을 받는다. 본 연구에서는 국내 14개 현장에서 실시된 조사 자료를 토대로 수리지질학적 인자(Lu, SPI)와 불연속면 인자(RQD, Js), 그라우트 주입량(grout take) 간의 상관관계를 분석하고 암반 그라우팅 계획의 체계적인 수립 방안을 제시하였다. 연구 인자(RQD, Js, Lu, SPI) 간의 피어슨 상관계수(r)를 분석한 결과, Lu과 SPI의 상관관계(r = 0.92)가 가장 높고, RQD와 Lu(r = -0.75), RQD와 Js(r = 0.69), RQD와 SPI(r = -0.65), Js와 Lu(r = -0.47), SPI와 Js(r = -0.41) 순으로 상관관계가 감소하는 것으로 나타났다. 그라우트 주입량과 연구 인자(RQD, Js, Lu, SPI) 간 상관관계를 분석한 결과, Lu과 SPI는 값이 커질수록 주입량이 증가하는 경향을 보이나 RQD와 Js는 유의한 상관관계가 나타나지 않았다. SPI를 토대로 제안된 그라우팅 계획 수립의 접근 방법은 실제 수행한 차수 그라우팅 시공 자료와 비교‧분석을 통해 검증하였고, 향후 세부 연구 및 실무 수행에 있어 유용한 자료로 활용될 수 있다.

2조형(條型) Combine의 이용(利用)에 관(關)한 연구(硏究) (A Study on the Utilzation of Two Furrow Combine)

  • 이상우;김성래
    • 농업과학연구
    • /
    • 제3권1호
    • /
    • pp.95-104
    • /
    • 1976
  • 도입(導入)된 2조용(條用) Combine으로 통일(統一) 및 밀양(密陽) 15호(號) 수도품종(水稻品種)에 대(對)한 포장수확작업(圃場收穫作業)을 실시(實施)하여 Combine의 작업정도(作業精度) 작업성능(作業性能) 기계적(機械的)인 적응성(適應性)을 파악(把握)하고 한국(韓國)에서의 보급전망(普及展望)을 분석검토(分析檢討)한바 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 장간종(長稈種)인 밀양(密陽)15호(號)에 대(對)한 Combine 수확작업(收穫作業)은 수확적기(收穫適期)로 부터 13일(日) 경과후(經過後)까지 5회(回)에 걸쳐 시기별(時期別)로 수확작업(收穫作業)을 실시(實施)한바 완숙도(完熟度)에 관계(關係)없이 수확작업(收穫作業) 양호(良好)하였으며 포장손실율(圃場損失率) 1% 미탈곡율(未脫穀率) 1%로 양호(良好)한 편(便)이었다. 2. 단간종(短稈種)인 통일(統一)에 대(對)한 Combine 수확작업(收穫作業)은 완숙기(完熟期)로 부터 수확시기(收穫時期)가 경과(經過)될 수록 포장손실(圃場損失)이 Fig 1과 같은 경향으로 5.13%에서 10.34%로 증가(增加) 하였으며 통일(統一)벼 수확(收穫)을 위(爲)하여는 기계적(機械的)인 개선(改善)이 많이 요망(要望)되었다. 3. 공시(供試)된 Combine은 장간종용(長稈種用)의 기종(機種)이어서 벼 이삭의 높이가 균일(均一)치 못한 단간종(短稈種) 통일(統一)벼는 탈곡부(脫穀部)의 공급(供給) Chain과 급실(扱室)과의 거리가 커서 급동(扱胴)의 급치(扱齒)에 못미치는 부분(部分)이 있어 미탈곡립율(未脫穀粒率)이 평균(平均) 1.6%이었다. 4. Combine 탈곡부(脫穀部) 급동(扱胴)의 회전수(回轉數)(240~350R.P.M)와 동할미(胴割米)의 관계(關係)는 통일(統一) 및 밀양(密陽)15호(號) 양품종(兩品種) 모두 동할율(胴割率)이 1% 미만(未滿)으로 유의차(有意差)가 없었다. 5. 통일(統一)벼는 벼 이삭이 잎속에 들어 있어 탈곡시(脫穀時) 검불의 양(量)이 많으며 특(特)히 생탈곡시(生脫穀時)는 검불량이 더 많이 생기므로 양곡부(揚穀部) 및 배진구(排塵口)에서 폐쇄현상(閉鎖現像)이 자주 일어남으로 선별(選別) 및 배진장치(排塵裝置)의 개선(改善)이 요망(要望)된다. 6. Combine의 접지압(接地壓)은 $0.19kg/cm^2$로 Fig3과 같은 약(弱)한 지내력(地耐力)의 토양(土壤)에서 Combine의 Track이 25cm 침하(沈下)하여도 Combine의 주행(走行)은 가능(可能)하였다. 그러나 지내력(地耐力)은 지점(地点)에 따라 균일(均一)치 않아 침하(沈下)의 깊이가 균일(均一)치 못함으로 침하(沈下) 5cm정도(程度)에서는 예취(刈取) 높이의 조정(調整)없이 수확작업(收穫作業)이 가능(可能)할 것으로 인정(認定)된다. 7. 관행수확작업(慣行收穫作業)과 Combine 수확작업(收穫作業)의 경제성(經濟性)을 검토(檢討)한바 수도맥작(水稻麥作)의 연간(年間) 사용일수(使用日數)를 40일(日)로 하고 작업일수율(作業日數率) 60% 포장작업효율(圃場作業效率) 56%로 할 때 작업속도(作業速度)를 0.273m/sec로 하여 분석(分析)한바 1일작업시간(日作業時間)을 8시간(時間)으로 할 때 연간부담면적(年間負擔面積)이 4.7ha로 ha당(當) 수확작업비용(收穫作業費用)이 관행수확작업비용(慣行收穫作業費用)과 일치(一致)함으로 통일(統一)벼 수확작업(收穫作業)에 이용(利用)될 수 있도록 Combine의 기계적(機械的)인 보완개량(補完改良)이 뒤따르면 Combine의 흡착(吸着)은 경제적(經濟的)으로 타당(妥當)하다고 인정(認定)된다. 8. 장간종(長稈種)의 현(現) Combine을 통일품종수확(統一品種收穫) 작업(作業)에 이용(利用)키 위(爲)하여는 전면측방(前面側方)의 divider가 벼이식에 닿지 않도록 조절할 수 있게 하고 급동(扱胴)과 feed chain의 간격(間隔)을 좁히고 배진장치(排塵裝置)를 개량(改良)하고 수도간장(水稻稈長)에 따라 기계전후조정범위(機械前後調整範圍)를 넓히고 배수불량(排水不良)한 답(畓)에서의 이용(利用)을 위(爲)하여 Track의 폭(幅)을 넓히는 등(等)의 개량(改良)이 요망(要望)된다.

  • PDF

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석 (Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance)

  • 이정우;홍세미;김연래;최경식;정진범;이두현;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.131-135
    • /
    • 2006
  • 본 연구의 목적은 2차원적 이온전리함 배열의 특성을 분석하고 세기변조방사선치료 선량분포 확인의 유용성을 평가하기 위함이다. 본 실험에 사용된 2차원적 이온전리함 배열(MatriXX, Scanditronix-Wellhofer, IBA, Germany)은 $24{\times}24cm^2$ 범위에 1,024개의 평판형 전리함(용적: $0.08cm^3$, 직경: 4.5 mm, 높이: 5 mm, 배열간격: 7.62 mm)이 일정한 간격으로 배열되어있다. MatriXX의 특성분석을 위해 선량 직선성, 선량률 의존도, 출력 계수, 단기 선릉재현성을 분석하였으며, 선량분포 확인의 신뢰도를 평가하기 위해 Varian사의 동적쐐기와 세기변조 방사선치료의 선량분포를 분석하였다. 선량 직선성의 범위는 $1{\sim}800$cGy이었으며, 1% 미만의 오차율을 보였다. 선량률 의존성(범위 $100{\sim}600MU/min$)은 300 Mu/min을 기준으로 했을 때 모든 선량률 범위에서 0.4% 미만의 선량변화를 보였다. 또한, 물팬톰에서 0.1 cc 지두형 전리함으로 측정한 출력계수와 폴리스틸렌 팬톰에서 MatriXX로 측정한 출력계수를 비교하였다. 이 실험의 결과, $3{\times}3{\sim}24{\times}24cm^2$ 범위에서 0.5% 미만의 일치를 나타내었다. 단기 출력재현성 확인을 위하여 15분 간격으로 6회 측정한 결과, 0.5% 내의 차이를 보였다. 동적쐐기와 세기변조 방사선 조사면의 일치성 실험에서도 치료계획장치의 계산값과 필름측정값이 비교적 잘 일치함을 알 수 있었다. 본 연구를 통해 MatriXX의 물리적인 특성을 분석하였으며 세기변조방사선치료의 품질관리를 위한 유용성을 확인하였다.

  • PDF

유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1) (Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1))

  • 박정욱;박의섭;김태현;이창수;이재원
    • 터널과지하공간
    • /
    • 제28권5호
    • /
    • pp.400-425
    • /
    • 2018
  • 본 논문에서는 국제공동연구인 DECOVALEX-2019 프로젝트 Task B의 연구결과와 현황을 소개하였다. Task B의 주제는 'Fault slip modelling'으로 유체의 주입으로 인해 발생하는 단층의 재활성(미끄러짐, 전단파괴)과 수리역학적 거동을 예측할 수 있는 해석기법을 개발하는 데에 그 목적이 있다. 1단계 연구는 참가팀들이 연구주제에 대해 숙지하고, 벤치마크 모델을 대상으로 단층의 투수특성과 역학적 거동의 상호작용을 모사할 수 있는 해석코드를 개발할 수 있도록 하는 준비 단계의 연구이다. 본 연구에서는 TOUGH-FLAC 연동해석 기법을 사용하여 물 주입으로 인한 단층의 수리역학적 연계거동을 모사하였다. TOUGH2 해석에서는 단층을 Darcy의 법칙과 삼승법칙을 따르는 연속체 요소로 모델링하였으며, FLAC3D 해석에서는 미끄러짐과 개폐가 허용되는 불연속 인터페이스 요소를 통해 모사하였다. 두 가지 수리간극모델에 대하여 수리역학적 커플링 관계식을 수치화하였으며, 연속체 요소(수리모델)와 인터페이스 요소(역학모델)의 거동을 연계할 수 있는 해석기법을 제시하였다. 또한, 단층의 역학적 변형(간극의 변화)으로 인한 수리물성 변화와 기하학적 변화(해석 메쉬의 변형)를 수리해석에 반영할 수 있는 해석기법을 개발하였다. 다양한 압력의 물을 단계적으로 주입하고 이로 인해 유도되는 단층의 탄성거동 및 전단파괴(미끄러짐)에 대해 살펴보았으며, 수리간극의 변화 양상과 원인, 압력 분포와 주입율의 관계 등을 면밀히 검토하였다. 해석 결과, 본 연구에서 개발한 해석기법이 물 주입으로 인한 단층의 미끄러짐 거동을 합리적인 수준에서 재현할 수 있는 것으로 판단할 수 있었다. 본 연구의 해석모델은 Task B에 참여하는 국외 연구팀들과의 의견 교류와 워크숍을 통해 지속적으로 개선하는 한편, 향후 연구의 현장시험에 적용하여 타당성을 검증할 예정이다.

인공 환기가 필요한 환자에서 변형된 수동식 인공호흡기(Ambu®)의 유용성 (Usefulness of modified ambu® in patients who need artificial ventilation)

  • 하기수;문일홍;이희선;신동한;은소희;은백린;홍영숙;이주원
    • Clinical and Experimental Pediatrics
    • /
    • 제49권11호
    • /
    • pp.1194-1201
    • /
    • 2006
  • 목 적 : 혼수 환자는 원인에 상관없이 혼수 상태가 오래 지속되었을 경우 회복불능의 상태로 될 수 있기 때문에 원인을 신속하게 발견하여 치료하는 것이 중요하다. 그 중 MRI 검사는 혼수 환자의 원인을 감별하는데 중요하나 자발호흡이 없는 환자에게 MRI 검사 시 여러 가지 제한점으로 인해 그 시행이 어려웠다. 저자들은 변형된 수동식 인공호흡기를 이용하여 일정 거리에서 환자에게 전달되는 환기량을 유지하면서 MRI 검사가 가능한지 알아보고 안정성을 확인하고자 본 연구를 실시하였다. 방 법 : 특별히 고안한 장치는 self-inflating bag type의 수동식 인공호흡기에 PVC 관을 연결하고 그 끝을 환자의 기도와 연결하여 만든 비교적 간단한 장치이다. 또한 안정성을 확인하기 위하여 기계식 인공호흡기를 이용하여 PVC 연결 관의 길이와 직경 및 일회호흡량(tidal volume)을 변화시켰을 경우 TVe, MVe, PIP를 측정하여 환기에 미치는 영향에 대해 알아보았다. 결 과 : 15 mm, 25 mm 직경의 2가지 종류의 PVC 연결 관을 이용하여 TVi를 변화시킴과 동시에 관의 길이를 1, 2, 3 m로 증가시킴에 따라 TVe, MVe, PIP 값을 측정하였으며, 그 결과 TVe, MVe 값은 대조군과 비교해 차이가 없었고 PIP 값은 TVi가 증가함에 따라, 관의 길이가 늘어남에 따라 의미 있는 증가를 보였다(P<0.05). 또한 관의 길이, TVi에 관계없이 PIP 값은 PVC 연결 관의 직경과 음의 상관관계를 보였다. 즉 관의 직경이 작을수록, 관의 길이가 길어질수록, 일회호흡량이 증가할수록, 환기량을 유지하기 위한 PIP값은 증가하였다. 5명의 환자들을 대상으로 이러한 방법을 이용하여 MRI 검사를 시행하였으며 성공적으로 검사를 실시하였다. 결 론 : 저자들이 고안한 수동식 인공호흡기를 이용한다면 자발호흡이 불안정하여 MRI 검사를 시행하지 못했던 많은 환자들에게 더 많은 검사의 기회가 주어질 것이며 환자의 질환을 진단하는데 많은 도움을 줄 것이다.

Research of Diffusion Bonding of Tungsten/Copper and Their Properties under High Heat Flux

  • Li, Jun;Yang, Jianfeng
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.14-14
    • /
    • 2011
  • W (tungsten)-alloys will be the most promising plasma facing armor materials in highly loaded plasma interactive components of the next step fusion reactors due to its high melting point, high sputtering resistance and low deuterium/tritium retention. The bonding technology of tungsten to Cu alloy was one of the key issues. In this paper, W/CuCrZr diffusion bonding has been performed successfully by inserting pure metal interlay. The joint microstructure, interfacial elements migration and phase composition were analyzed by SEM, EDS, XRD, and the joint shear strength and micro-hardness were investigated. The mock-ups were fabricated successfully with diffusion bonding and the cladding technology respectively, and the high heat flux test and thermal fatigue test were carried out under actively cooling condition. When Ni foil was used for the bonding of tungsten to CuCrZr, two reaction layers, Ni4W and Ni(W) layer, appeared between the tungsten and Ni interlayer with the optimized condition. Even though Ni4W is hard and brittle, and the strength of the joint was oppositely increased (217 MPa) due primarily to extremely small thicknesses (2~3 ${\mu}m$). When Ti foil was selected as the interlayer, the Ti foil diffused quickly with Cu and was transformed into liquid phase at $1,000^{\circ}C$. Almost all of the liquid was extruded out of the interface zone under bonding pressure, and an extremely thin residual layer (1~2 ${\mu}m$) of the liquid phase was retained between the tungsten and CuCrZr, which shear strength exceeded 160 MPa. When Ni/Ti/Ni multiple interlayers were used for bonding of tungsten to CuCrZr, a large number of intermetallic compound ($Ni_4W/NiTi_2/NiTi/Ni_3T$) were formed for the interdiffusion among W, Ni and Ti. Therefore, the shear strength of the joint was low and just about 85 MPa. The residual stresses in the clad samples with flat, arc, rectangle and trapezoid interface were estimated by Finite Element Analysis. The simulation results show that the flat clad sample was subjected maximum residual stress at the edge of the interface, which could be cracked at the edge and propagated along the interface. As for the rectangle and trapezoid interface, the residual stresses of the interface were lower than that of the flat interface, and the interface of the arc clad sample have lowest residual stress and all of the residual stress with arc interface were divided into different grooved zones, so the probabilities of cracking and propagation were lower than other interfaces. The residual stresses of the mock-ups under high heat flux of 10 $MW/m^2$ were estimated by Finite Element Analysis. The tungsten of the flat interfaces was subjected to tensile stresses (positive $S_x$), and the CuCrZr was subjected to compressive stresses (negative $S_x$). If the interface have a little microcrack, the tungsten of joint was more liable to propagate than the CuCrZr due to the brittle of the tungsten. However, when the flat interface was substituted by arc interfaces, the periodical residual stresses in the joining region were either released or formed a stress field prohibiting the growth or nucleation of the interfacial cracks. Thermal fatigue tests were performed on the mock-ups of flat and arc interface under the heat flux of 10 $MW/m^2$ with the cooling water velocity of 10 m/s. After thermal cycle experiments, a large number of microcracks appeared at the tungsten substrate due to large radial tensile stress on the flat mock-up. The defects would largely affect the heat transfer capability and the structure reliability of the mock-up. As for the arc mock-up, even though some microcracks were found at the interface of the regions, all microcracks with arc interface were divided into different arc-grooved zones, so the propagation of microcracks is difficult.

  • PDF