• 제목/요약/키워드: Pressure down

검색결과 792건 처리시간 0.021초

Monolithic SiGe Up-/Down-Conversion Mixers with Active Baluns

  • Lee, Sang-Heung;Lee, Seung-Yun;Bae, Hyun-Cheol;Lee, Ja-Yol;Kim, Sang-Hoon;Kim, Bo-Woo;Kang, Jin-Yeong
    • ETRI Journal
    • /
    • 제27권5호
    • /
    • pp.569-578
    • /
    • 2005
  • The purpose of this paper is to describe the implementation of monolithically matching circuits, interface circuits, and RF core circuits to the same substrate. We designed and fabricated on-chip 1 to 6 GHz up-conversion and 1 to 8 GHz down-conversion mixers using a 0.8 mm SiGe hetero-junction bipolar transistor (HBT) process technology. To fabricate a SiGe HBT, we used a reduced pressure chemical vapor deposition (RPCVD) system to grow a base epitaxial layer, and we adopted local oxidation of silicon (LOCOS) isolation to separate the device terminals. An up-conversion mixer was implemented on-chip using an intermediate frequency (IF) matching circuit, local oscillator (LO)/radio frequency (RF) wideband matching circuits, LO/IF input balun circuits, and an RF output balun circuit. The measured results of the fabricated up-conversion mixer show a positive power conversion gain from 1 to 6 GHz and a bandwidth of about 4.5 GHz. Also, the down-conversion mixer was implemented on-chip using LO/RF wideband matching circuits, LO/RF input balun circuits, and an IF output balun circuit. The measured results of the fabricated down-conversion mixer show a positive power conversion gain from 1 to 8 GHz and a bandwidth of about 4.5 GHz.

  • PDF

노인여성의 정적직립자세에서 지면반력 주파수 분석 (Analysis of Frequency domain Characteristics of Ground Reaction Forces during Quiet Standing of Elderly Women)

  • 이경순
    • 대한물리치료과학회지
    • /
    • 제19권1호
    • /
    • pp.63-69
    • /
    • 2012
  • Background : The purpose of this study was to investigate the frequency domain characteristics of ground reaction forces during quiet standing on inclined surfaces twenty healthy individuals(10 elderly women $68.78{\pm}3.29$ years and 10 young women $20.90{\pm}0.74$ years) participated. Methods : Subjects stood in quiet stance over a force platform positioned in one of three different fixed positions: flat, down and up. Healthy participants completed with eyes open for 120 s trials. Evaluation of postural control were generally based on the interpretation of center of pressure(COP) time series. The COP have been determined using an experimental setup with 3D kinematic and the ground reaction force system. All the data were expressed means and standard deviation by using SAS package program. Results : SEF 50% were not significant in AP and ML direction according to surface slope of both groups. SEF 95% were showed highest frequency in AP direction on down slope of both groups. MEF were not significant all direction according to surface slopes of elderly women. There was no difference between young and elderly women. Conclusion : Elderly women used to ankle strategy during a quiet stance according to COP perturbation of AP direction showed more expanded than ML direction. SEF 95% were showed highest frequency on down slope in elderly women who showed more used ankle strategy for postural control on down slope.

  • PDF

성토사면의 붕괴에 관한 실험적 연구 (Experimental Study on the Slope Failure of Embankment)

  • 강우묵;이달원;지인택;조재홍
    • 한국농공학회지
    • /
    • 제35권3호
    • /
    • pp.47-62
    • /
    • 1993
  • The laboratorv model test was carried out to investigate the behavior of pore water pressure, the critical amount of rainfall for slope failure, the pattern of failure, and the variation of seepage line at the slope with the uniform material of embankment by changing the slope angles and rainfall intensities. The results were was summarised as follows : 1.At the beginning stage of rainfall, the negative pore pressure appeared at the surface of slope and the positive pore pressure at the deep parts. But, the negative one turned into the positive one as the rainfall continued and this rapidly increased about 50 to 100 minutes before the slope failure. 2.The heavier the rainfall intensity, the shorter the time, and the milder the slope, the longer the time took to reach the failure of slope. 3.As the angle of the slope became milder, the critical amount of rainfall for slope failure became greater. 4.Maximum pore water pressure was 10 to 40g/cm$^2$ at the toe of slope and 50 to 90g/cm$^2$at the deep parts. 5.In the respect of the pattern of slope failure, surface failure of slope occurred locally at the toe of slope at the A-soil and failure of slope by surface flow occurred gradually at the top part of slope at the B-soil. 6.As the rainfall continued and the saturation zone in the embankment was formed, the seepage line went rapidly up and also the time to reach the total collapse of slope took longer at the B-soil. 7.As the position of the seepage line went up and the strength parameter accordingly down, the safety factor was 2.108 at the A-soil and 2.150 at the B-soil when the slope occured toe failure. Minimum safety factor was rapidly down to 0.831 at the A-soil and to 0.936 at the B-soil when the slope collapsed totally at the top part of slope.

  • PDF

압력맥파 및 광전용적맥파 검출용 일체형 센서의 구현 및 평가 (Implementation and evaluation of the sensor assessing pressure and photoplethysmogram)

  • 김기련;김광년;최병철;전계록;함기영;서덕준;정동근
    • 센서학회지
    • /
    • 제15권2호
    • /
    • pp.106-111
    • /
    • 2006
  • Pulse sensors generally have characteristics that cause a analytical error by the interference of signals according to tiny motion of body and pressure applied to skin. To resolve this problem, we implemented the sensor that is capable of simultaneously measuring pressure and PPG(photoplethymogram) in a state attached to skin. Pressure and PPG was recorded at the finger and wrist respectively to evaluate the usefulness of the implemented sensor. Then, it was observed that the shape of PPG from sensor changed by pressure pushing down skin. Results of this study suggested that it is possible to monitor a degree of skin pressurization and to guarantee a reliable measurement by simultaneously measuring pressure and PPG using implemented integrated sensor when measuring PPG on the wrist or the finger.

통합 제연시스템의 컨트롤러 개발에 관한 연구 (A Study on the Controller of Integration Smoke Control System)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제20권1호
    • /
    • pp.77-82
    • /
    • 2006
  • 본 연구에서는 온도가 보상된 압력을 제연구역의 기준압력으로 설정하기 위한 공학적인 메커니즘과 보상방법을 정립하였고, 통합 제연시스템의 컨트롤러의 개발을 위한 프로세스, 알고리즘 확립과 엔지니어링 데이터의 구축으로 신뢰성이 확보된 통합 제연시스템의 컨트롤러를 개발하였다. 컨트롤러를 개발함으로서 비제연구역의 압력측정을 위해서 별도로 설치되는 압력측정관을 생략할 수 있어 제작단가와 설치비용 및 작업공수를 줄일 수 있고, 층별 제연구역의 차압측정을 위한 비제연구역의 압력측정포트를 시스템에 일체화함으로서 차압의 정밀도를 향상시킬 수 있다. 기존의 개별제어 방식에서 통합 제연시스템의 컨트롤러로부터 중앙집중식 통합관리를 함으로서 보다 정확하고 신뢰성 있는 차압을 얻을 수 있으며, 제연시스템에 유연성을 부과시킬 수 있을 것으로 본다. 또한 통합 제연시스템의 기틀을 마련하고 제연의 유연성을 주며 방재성능을 향상시킬 것으로 본다.

원심펌프의 시동 및 정지에 따른 수격현상 (Waterhammer Caused by Startup and Stoppage of a Centrifugal Pump)

  • 김경엽;김점배
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.51-57
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity As the pressure waves are propagating between the pumping station and the distributing reservoir, the pressure inside the pipe drops to the liquid vapor pressure with the pipeline profile, at which time a vapor cavity forms, and finally the column separation occurs. If the pressure in the pipe is less than the atmospheric pressure, the pipe can be collapsed and destroyed after the water columns separated by the vapor cavity rejoin. During the reverse flow, the pressure is so abnormally increased at the pumping station that the accident of flooding may happen due to the failure of system. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations, in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

운동화, 하이힐, 그리고 킬힐에 따른 족압과 주관적 불편도 평가 (Evaluation of Foot Pressures and Subjective Discomfort Ratings associated with Sneakers, High Heels, and Kill Heels)

  • 송재웅;김성자;이가희;송기범;공용구
    • 대한인간공학회지
    • /
    • 제28권3호
    • /
    • pp.95-102
    • /
    • 2009
  • Ten young females were participated in this study to investigate the effects of types of shoes (sneakers, high heels, kill heels), types of tasks (standing, walking floor, step up and down), and areas of foot (fore foot, middle foot, rear foot) on foot pressures as well as subjective discomfort ratings. Results showed that kill heels had the most discomfort shoes, followed by high heels and sneakers. Generally, as the heel was higher, the discomfort of foot increased. For the analyses of task types, generally discomfort ratings were highest for the step down and up, followed by walking floor and standing. Especially discomfort ratings of high heels and kill heels were more evident in case of step up and step down than standing and walking floor. Standing task was rated as the lowest levels of discomfort on users' foot. Peak and mean foot pressures were also evaluated in this study. The findings represented that there was no significant differences between types of shoes in both peak and mean foot pressures. The peak pressure (82.14kPa) and mean pressure (40.32kPa) for standing task were significantly lower than those of other tasks [walking floor (190.55kPa, 55.46kPa), step up (191.43kPa, 53.80kPa), and step down (200.66kPa, 52.62kPa)]. Generally discomfort ratings and peak/mean pressures associated with foot showed that fore foot had higher discomfort ratings as well as peak and mean pressures than middle and rear foots. In particularly, this trend was more obvious in case of high heels and kill heels. For the high heels and kill heels, the peak pressures of fore foot were 4.5~4.8 times and 2.3~2.5 times greater than that of middle foot and rear foot, respectively, whereas the peak pressures of fore foot were 2.9 times and 1.7 times greater than that of middle and rear foots, respectively, in case of sneakers.

수소 Joule-Thomson냉동기의 성능실험 (Performance test of Joule-Thomson cryocooler with $H_2$gas)

  • 백종훈;강병하;홍성제;장호명
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.457-463
    • /
    • 1999
  • The Joule-Thomson cryocooler with $H_2$gas has been developed. Cool-down characteristics and the cooling performance of a JT cryocooler have been investigated in detail. The JT cryocooler consists of JT expansion valve, heat exchanger, expansion chamber, compressed $H_2$gas storage tank, $LN_2$precooler, heater and a cryostat. The precooling process using both $GN_2$and $LN_2$was peformed to cool down the inside components of cryocooler under the maximum inversion temperature of $H_2$. The $H_2$expansion experiments have been peformed for 2-5MPa of H$_2$pressure to evaluate steady state temperatures of the cryocooler. It is found that the steady state temperatures are decreased as the H$_2$pressures are increased. The effects of cooling temperatures on the performance have been evaluated for various $H_2$and $N_2$pressures. It is seen that the cooling loads are increased, as the cooling temperature and operating pressure are increased.

  • PDF

균일유동에 수직인 2차원 스크린 후류의 점성유동에 관한 수치적 연구 (Numerical Study on Viscous Wakes of Two-Dimensional Screens Normal to the Uniform Stream)

  • 강신형;전우평
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.590-598
    • /
    • 1988
  • 본 연구에서는 난류유동이론을 적용하여 2차원 스크린의 후류에 관한 유동특 성을 연구하였다. 이를 위해 적합한 난류모델 및 스크린의 존재를 고려한 수치해석 방법을 연구하였다. 스크린의 저항이 커서 스크린 하류유동이 역류가 되는 경우도 포함하였다.

고받음각 2차원 에어포일 주위의 비정상 유동의 진동 특성에 관한 연구 (ANALYSIS OF UNSTEADY OSCILLATING FLOW AROUND TWO DIMENSIONAL AIRFOIL AT HIGH ANGLE OF ATTACK)

  • 유재경;김재수
    • 한국전산유체공학회지
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2013
  • Missile and fighter aircraft have been challenged by low restoring nose-down pitching moment at high angle of attach. The consequence of weak nose-down pitching moment can be resulting in a deep stall condition. Especially, the pressure oscillation has a huge effect on noise generation, structure damage, aerodynamic performance and safety, because the flow has strong unsteadiness at high angle of attack. In this paper, the unsteady aerodynamics coefficients were analyzed at high angle of attack up to 50 degrees around two dimensional NACA0012 airfoil. The two dimensional unsteady compressible Navier-Stokes equation with a LES turbulent model was calculated by OHOC (Optimized High-Order Compact) scheme. The flow conditions are Mach number of 0.3 and Reynolds number of $10^5$. The lift, drag, pressure, entropy distribution, etc. are analyzed according to the angle of attack. The results of average lift coefficients are compared with other results according to the angle of attack. From a certain high angle of attack, the strong vortex formed by the leading edge are flowing downstream as like Karman vortex around a circular cylinder. The primary and secondary oscillating frequencies are analyzed by the effects of these unsteady aerodynamic characteristics.