• 제목/요약/키워드: Pressure down

검색결과 792건 처리시간 0.024초

B-Spline 및 유한요소 유연화법 활용 자동차 록업클러치의 형상최적화 (The Shape Optimization of a Torque Converter Lock-up Clutch Using the B-Spline and Finite Element Mesh Smoothing)

  • 현석정;김철;손종호;신세현;장재덕;주인식
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.101-108
    • /
    • 2004
  • A FEM-based efficient method is developed for the shape optimization of 2-D structures. The combined SLP and Simplex method are coupled with finite element analysis. Selected set of master nodes on the design boundaries are employed as design variables and assigned to move towards their normal directions. The other nodes along the design boundaries are grouped into the master node. By interpolating the repositioned master nodes, the B-spline curves are formed so that the rest mid-nodes efficiently settle down on the B-spline curves. Mesh smoothing scheme is also applied for the nodes on the design boundary to maintain most finite elements in good quality. Finally, a numerical implementation of optimum design of an automobile torque converter piston subjected to pressure and centrifugal loads is presented. The results shows additional weight up to 13% may be saved after the shape optimization.

소동물 [F-18]FDG 양전자단층촬영 기법을 이용한 청각신경에서의 소리크기에 대한 적응효과 연구 (The Effect of Adaptation to Sound Intensity on the Neural Metabolism in Auditory Pathway: Small Animal PET Study)

  • 장동표
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권1호
    • /
    • pp.55-60
    • /
    • 2011
  • Although sound intensity is considered as one of important factors in auditory processing, its neural mechanism in auditory neurons with limited dynamic range of firing rates is still unclear. In this study, we examined the effect of sound intensity adaptation on the change of glucose metabolism in a rat brain using [F-18] micro positron emission tomography (PET) neuroimaging technique. In the experiment, broadband white noise sound was given for 30 minutes after the [F-18]FDG injection in order to explore the functional adaptation of rat brain into the sound intensity levels. Nine rats were scanned with four different sound intensity levels: 40 dB, 60 dB, 80 dB, 100 dB sound pressure level (SPL) for four weeks. When glucose uptake during the adaptation of a high intensity sound level (100 dB SPL) was compared with that during adaptation to a low intensity level (40 dB SPL) in the experiment, the former induced a greater uptake at bilateral cochlear nucleus, superior olivary complexes and inferior colliculi in the auditory pathway. Expectedly, the metabolic activity in those areas linearly increased as the sound intensity level increased. In contrast, significant decrease interestingly occurred in the bilateral auditory cortices: The activities of auditory cortex proportionally decreased with higher sound intensities. It may reflect that the auditory cortex actively down-regulates neural activities when the sound gets louder.

Material structure generation of concrete and its further usage in numerical simulations

  • Husek, Martin;Kala, Jiri
    • Structural Engineering and Mechanics
    • /
    • 제68권3호
    • /
    • pp.335-344
    • /
    • 2018
  • The execution of an experiment is a complex affair. It includes the preparation of test specimens, the measurement process itself and also the evaluation of the experiment as such. Financial requirements can differ significantly. In contrast, the cost of numerical simulations can be negligible, but what is the credibility of a simulated experiment? Discussions frequently arise concerning the methodology used in simulations, and particularly over the geometric model used. Simplification, rounding or the complete omission of details are frequent reasons for differences that occur between simulation results and the results of executed experiments. However, the creation of a very complex geometry, perhaps all the way down to the resolution of the very structure of the material, can be complicated. The subject of the article is therefore a means of creating the material structure of concrete contained in a test specimen. Because a complex approach is taken right from the very start of the numerical simulation, maximum agreement with experimental results can be achieved. With regard to the automation of the process described, countless material structures can be generated and randomly produced samples simulated in this way. Subsequently, a certain degree of randomness can be observed in the results obtained, e.g., the shape of the failure - just as is the case with experiments. The first part of the article presents a description of a complex approach to the creation of a geometry representing real concrete test specimens. The second part presents a practical application in which the numerical simulation of the compressive testing of concrete is executed using the generated geometry.

Kinematic Comparative Analysis of Long Turns between Experienced and Inexperienced Ski Instructors

  • Jo, Hyun Dai
    • 한국운동역학회지
    • /
    • 제30권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Objective: The purpose of this study is to provide a better understanding of long turn mechanism by describing long turns after kinematic analysis and provide skiers and winter sports instructors with data through which they are able to analyze right postures for turns in skiing in a systematic, rational and scientific manner. Method: For this, a mean difference of kinematic variables (the center of gravity (CG) displacement of distance, trajectory, velocity, angle) was verified against a total of 12 skiers (skilled and unskilled, 6 persons each), regarding motions from the up-start to down-end points for long turns. Results: First, concerning the horizontal displacement of CG during a turn in skiing, skilled skiers were positioned on the right side at the upstart and edge-change points at a long turn. There was no difference in anteroposterior and vertical displacements. Second, in terms of CG-trajectory differences, skilled skiers revealed a significant difference during a long turn. Third, regarding skiing velocity, skilled skiers were fast at the edge-change and maximum inclination points in long turns. Fourth, there was no difference in a hip joint in terms of a lower limb joint angle. In a knee joint, a large angle was found at the up-start point among skilled skiers when they made a long turn. Conclusion: In overall, when skilled and unskilled skiers were compared, to make a good turn, it is required to turn according to the radius of turn by reducing weight, concerning the CG displacement. Regarding the CG-trajectory differences, the edge angle should be adjusted via proper inclination angulation. In addition, a skier should be more leaned toward the inside of a turn when they make a long turn. In terms of skiing velocity, it is needed to reduce friction on snow through the edging and pivoting of the radius or turn according to curvature and controlling ski pressure. Regarding a lower limb joint angle, it is important to make an up move by increasing ankle and knee angles instead of keeping the upper body straight during an up motion.

전기침이 면역증진에 미치는 효과 (Effects of Electroacupuncture on Immune Function)

  • 강세영;정은우;이상관;성강경
    • Journal of Acupuncture Research
    • /
    • 제24권6호
    • /
    • pp.29-36
    • /
    • 2007
  • Electroacupuncture(EA) is known to affect various autonomic functions such as blood pressure regulation, immune modulation and the improvement of disorders concerning autonomic functions. The aim of the present study was to establish whether EA has an immune-enhancing effect. ICR mice weighing 20 to 25g were divided into four groups: Group I(n=6), blank; Group II(n=6), control; Group III(Zusanli, n=6), low frequency-EA(10Hz of electrical stimulation), and Group IV(Zusanli, n=6), high frequency-EA (100Hz of electrical stimulation). For this study, we investigated expressions of spleen heat shock protein (HSP)70, HSP90 and secretions of cytokines. A Forced Swimming Test(FST) was performed as a model of activity test in mice. After three days of the FST, 10Hz EA($114.8{\pm}7.27s$) and 100Hz EA($147.5{\pm}1.29s$) immobility time significantly decreased compared with the control group($157.2{\pm}1.48s$). After seven days, 10Hz EA($124{\pm}1s$) and 100Hz EA($141{\pm}4.24s$) also significantly decreased immobility time compared with the control group($168{\pm}7.93s$). 10Hz EA and 100Hz EA increased the expression of HSP70 but did not change that of HSP90. 100Hz EA increased secretions of IL-6 and IL-12 compared with the control group however, 10Hz EA failed to change those of IL-6 and IL-12. The present results suggest that EA may be useful for down-regulated immune diseases.

  • PDF

수술 환자에게 적용한 가온요법 연구논문 분석 (Analysis of Researches on the Warming Therapy for Surgical Patients)

  • 전점이
    • 성인간호학회지
    • /
    • 제22권3호
    • /
    • pp.260-270
    • /
    • 2010
  • Purpose: The main question is systematic review of the published in Korea and foreign countries on warming therapy for surgical patients. Methods: The researchers searched at Medline, CINAHL, KERIS, Adult Nursing Association, Korean Society of Nursing Science, Korean Academy of fundamentals of Nursing, and National Assembly Library web site for the published on warming therapy for surgical patients from 1980 to 2008. Words for search were operation/surgery, warming, operation/surgery and warming. Studies were included randomized controlled trial, and there were no restrictions regarding operative phase and outcome measures. Results: 36 published researches that met the criteria were mostly published in foreign countries between 2000 and 2008 and focused on surgery with general anesthesia. Sample size ranged from 21 to 60 subjects, age range between 21 and 60 years of age. Thirty different warming therapies were reported, fifty-two different dependent variables. Outcome indicators included active external warming, intra-operative, and body temperature. 'Positive effects' and 'no effects' equaled. The most frequently reported 'positive effects' were body temperature, shivering, and acid-base balance. No effects were more likely to be heart rate, blood pressure, and hemodynamics. Conclusion: Many types of warming therapy, are reported in the literature with little information about the efficacy of each, many different dependant variables were studied. There were no consistent reports as to length of time used for warming procedures. Overall, the effects of warming therapy are inconsistent. And additional research must be down before any particular method of warming can be used with confidence as to its effectiveness. Attention must be made as to the research design, better measurement of the dependent variables. This review may serve as a base.

BMI에 따른 요골동맥의 혈관특성과 부/침맥과의 상관관계 연구 (The Study for Correlation Characteristics on Radial Artery and Floating/sinking Pulse with BMI)

  • 이유정;이전;이혜정;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권3호
    • /
    • pp.121-126
    • /
    • 2008
  • Pulse diagnosis refers to the process of diagnosing a patient by feeling an artery on the wrist based on the shape that the pulse take s while the hold-down pressure increase. The styloid process artery on the wrist is usually felt, and the pulse is taken on Chon, Gwan and Cheok using three fingers. This study is to examine the structural difference in the location of pulse diagnosis by measuring and analyzing blood diameter, blood depth, and blood flow velocity of the location of pulse diagnosis by using ultrasonic wave (VOLUSION730 PRO, GE Medical, U.S.A). This study also attempted to grasp whether the characteristics of blood vessels differ depending on Body Mass Index (BMI) and analyzed their correlation with Oriental medical pulse diagnosis. The male subjects without cardiovascular diseases were divided into the normal BMI group, the underweight group and the overweight group and 10 people of each group were measured, Blood depth, blood diameter and blood flow velocity at the location of pulse diagnosis (Chon, Gwan, Cheok) of the wrists of left and right hands were measured and the pulse wave was measured by using pulse diagnosis instrument (3-D Mac, DaeyoMedi, Korea).The results of this study showed that the characteristics of blood vessels differ depending on the degrees of obesity, and the characteristics of floating pulse and sinking pulse of Oriental medical pulses were related to the degrees of obesity. This shows that the characteristics of the blood vessels of subjects and BMI information are the major indicators for diagnosis and are the matters that must always be considered when developing the algorithm of pulse diagnosis.

  • PDF

커튼월 스팬드럴용 진공유리의 열파손에 대한 비교실험 (A Comparative Experiment on Thermal Stress Failure of Vacuum Glazing applied in Curtain Wall at Spandrel area)

  • 김승철;윤종호;신우철;안정혁
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.121-128
    • /
    • 2016
  • Purpose: The vacuum glazing should constantly retain the gap in vacuum state to maintain high thermal performance. To do so, pillars are used to prevent the glazing from clinging to each other by the atmospheric pressure and therefore surface of the vacuum glazing is consistently affected by residual stress. The vacuum glazing could be applied to curtain wall systems at spandrel area to fulfill a rigorous domestic standard on U-value of the external wall. However, this can lead to high glazing temperature increase by heat concentration at a back panel and finally thermal stress breakage. This study experimentally determined weakness of the vacuum glazing systems on the thermal stress breakage and investigated effect of the residual stress. Method: The experiment first built two scale-down mock-up facilities that replicate the spandrel area in curtain wall, and then installed single low-e glass and vacuum glazing respectively. The two mock-up facilities were exposed to outside to induce the thermal stress breakage. Result: The experiment showed that the temperature occurred the thermal stress breakage was $114.4^{\circ}C$ for the single low-e glass and $118.9^{\circ}C$ for the vacuum glazing respectively. The result also showed the vacuum glazing reached the critical point earlier than the single low-e glass, which means that the vacuum glazing has high potential to occur the thermal shock breakage. In addition, the small temperature difference between two glazing indicates that the residual stress scarcely affects breakage of the vacuum glazing.

Line-CCD를 이용한 수중광학 센서 시스템의 구현 (Implementation of Marine Optical Sensor System Using A Line-CCD)

  • 정의석;이동호;이경운;임아람;정재욱;박정호
    • 전기전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.244-249
    • /
    • 2010
  • 수중의 미립자 계수를 위한 Line-CCD를 이용한 수중광학 시스템을 구현하였다. 미립자 계수 측정을 위하여 680nm Laser diode를 광원으로 사용하였다. 광학시스템을 동작확인을 위해 수중 인공탱크 및 해양에서 실험을 하였다. 시스템의 상 하강 운동 시, 마이크로프로세서(FPGA)의 신호 전달(센서의 신호검출)을 통하여 미립자 계수를 알 수 있다. 시스템의 알고리즘은 또한, 깊이에 따른 압력, 온도, 계수 값을 실시간으로 분석한다. 실험을-통해 광학센서 시스템의 높은 정확도를 보여주었다. 따라서, Line-CCD를 통한 실시간 측정 가능한 수중광학 시스템을 제안 하였다.

KZ 필터를 이용한 부산지역 PM10의 장기 추세 분석 (Analysis of the Long-term Trend of PM10 Using KZ Filter in Busan, Korea)

  • 도우곤;정우식
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.221-230
    • /
    • 2017
  • To determine the effect of air pollution reduction policies, the long-term trend of air pollutants should be analyzed. Kolmogorov-Zurbenko (KZ) filter is a low-pass filter, produced through repeated iterations of a moving average to separate each variable into its temporal components. The moving average for a KZ(m, p) filter is calculated by a filter with window length m and p iterations. The output of the first pass subsequently becomes the input for the next pass. Adjusting the window length and the number of iterations makes it possible to control the filtering of different scales of motion. To break down the daily mean $PM_{10}$ into individual time components, we assume that the original time series comprises of a long-term trend, seasonal variation, and a short-term component. The short-term component is attributable to weather and short-term fluctuations in precursor emissions, while the seasonal component is a result of changes in the solar angle. The long-term trend results from changes in overall emissions, pollutant transport, climate, policy and/or economics. The long-term trend of the daily mean $PM_{10}$ decreased sharply from $59.6ug/m^3$ in 2002 to $44.6ug/m^3$ in 2015. This suggests that there was a long-term downward trend since 2005. The difference between the unadjusted and meteorologically adjusted long-term $PM_{10}$ is small. Therefore, we can conclude that $PM_{10}$ is unaffected by the meteorological variables (total insolation, daily mean temperature, daily mean relative humidity, daily mean wind speed, and daily mean local atmospheric pressure) in Busan.