• Title/Summary/Keyword: Pressure contribution analysis

Search Result 102, Processing Time 0.027 seconds

Reducing the Interior Noise of the Korean High-speed Train Using Geometric Acoustic Method (기하음향 기법을 적용한 한국형 고속철도 실내소음 저감 방안)

  • Kim, Kwan-Ju;Park, Jin-Kyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.431-436
    • /
    • 2002
  • The interior sound pressure level of the Korean high-speed train(KHST) is predicted by geometrical acoustic method. For the Purpose of assuring the prediction of Interior noise of KHST by the geometrical acoustic scheme, calculated sound level values of the Korean train express(KTX) by Identical geometrical method are compared with measured values of KTX prototype vehicle by experiment. Contribution of individual sound source of KHST vehicle Into the interior response positions is calculated and sound sources are classified in influential order. Hence, it is reasonable approach to reduce sound power of most contributing noise source first. Sensitivity of the interior response position's sound pressure level (SPL) with respect to train wall sections' transmission loss are carried on and acoustically sensitive spot is identified, for example window area for passenger cabin case. Those contribution and sensitivity analysis results are suggested to design quieter train efficiently.

A Design Process for Structural Borne Noise using Panel Contribution and Design Sensitivity (판넬기여도와 설계민감도를 이용한 구조기인소음 설계프로세스)

  • Kim, Hyo-Sig;Kim, Heon-Hee;Cho, Hyo-Jin;Yoon, Seong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.806-811
    • /
    • 2007
  • In this study, we propose a more systematic design process for the structure-borne noise. The proposed way consists of 4 steps: Problem definition, Cause analysis, Development of counter-measure and Validation. Especially, we improved the second step: Cause analysis. According to the PCA(Panel Contribution Analysis), a reduction in vibration of the panels of which panel contribution is positive and larger, results in a reduction in structure-borne noise. We have, however, met the case in which the concept of PCA is no valid in a few vehicle tests. In order to understand this phenomenon, we compared the major panels selected by PCA with the one chosen by DSA(Design Sensitivity Analysis). After investigating the difference between the two results, a more improved process is suggested. The proposed one for the second step in the design process consists of not only the previous way: PCA with deformation analysis results but also DSA. It is finally validated that the proposed design process decreases the sound pressure of the concerned noise transfer function more than 3.5 dB.

  • PDF

A Study on Transfer Characteristics of Vehicle Air-conditioner Booming noise (차량용 에어컨 부밍 소음의 전달 특성에 관한 연구)

  • Lim, Seung Taek;Joo, Kyung Hoon;Ahn, Hew Nam;Park, Young Duk;Kang, Yean Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.476-481
    • /
    • 2013
  • Transfer path analysis(TPA) and operational deflection shape(ODS) have been widely utilized to analyze the characteristics of noise. TPA enables to decompose a noise into air-borne and structure-borne noises then estimate the path contribution of noise. ODS enables to analyze a moving shape and direction of interest components at a particular frequency. In this paper, TPA and ODS are applied to transfer paths of air-conditioner booming noise in a vehicle to reduce noise level, then a fixture is mounted it's path for distributing the high portion path contribution to the low portion path contribution. Through this experiment, the reduction of sound pressure level in air-conditioner booming noise is observed. Thereafter, TPA is again employed to verify the results of contribution.

  • PDF

Analysis of Noise Contribution using Frequency Response Function and Measurements of Noise Distribution for Railway Interior Noise (주파수 응답 함수를 이용한 철도차량 실내소음 기여도 분석 및 분포도 측정)

  • 김재철;유원희
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.949-954
    • /
    • 1999
  • Speed-up and mass reduction of railway vehicle usually causes increased of the interior noise. One of the best ways to control the interior noise is to identify the noise level radiated from each of parts in the cabin. In this paper, we describe the method to estimate the interior noise nad evaluate the noise contribution to each of parts. This method is based that the sound pressure can be calculated by using the frequency response function and acceleration. According to analysis of the noise contribution, we validated that the noise radiated from the floor is the higher in the cabin. We also measured the noise distribution for the side and floor by using the microphone array in order to analyze the effect of the noise flowing into the cabin from the outdoors. Finally, we presented the plan of the interior noise reduction based on the noise levels radiated from each of parts.

  • PDF

A Study on the Pulsation Pressure Reduction for the Hydraulic System of Medium-Large Excavator (중대형 굴삭기 유압시스템의 압력 맥동 저감 연구)

  • Kim, Young-Hyun;Joo, Won-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.421-426
    • /
    • 2010
  • With hydraulic noise test facility, a variety of tests were performed to investigate the pulsation pressure generation mechanism and its transmission characteristics and to derive the noise control methodology. Many experiments were carried out by changing average pressure, flow rate, pump speed, hose length and MCV spool condition. From the test results, the correlations between pulsation pressure and other design parameters, such as static pressure, flow rate and MCV spool opening area and length of hose, were found out. And also each contribution factors were evaluated from the regression analysis. By changing hose length, the pulsation pressure resonance phenomenon was investigated. In order to find out the pulsation pressure reduction measures pulsation pressure analysis, such as pulsation pressure of hydraulic pump itself and pulsation pressure of hydraulic system, by using AMESim were studied. In addition hydraulic silencer was developed based on the Helmholtz resonator. And its performance was evaluated by installing the silencer at the excavator.

  • PDF

Consumption of Ultra-Processed Food and Blood Pressure in Korean Adults

  • Sun Young Shim;Hyeon Chang Kim;Jee-Seon Shim
    • Korean Circulation Journal
    • /
    • v.52 no.1
    • /
    • pp.60-70
    • /
    • 2022
  • Background and Objectives: There is growing evidence supporting the association between ultra-processed food (UPF) consumption and metabolic disease risk. However, little is known about the association between UPF consumption and blood pressure (BP). Thus, this study examined the association between UPF consumption and elevated BP in Korean adults. Methods: This study used data from the Korea National Health and Nutrition Examination Survey (2016-2018) and included 9,188 participants aged 30-79 years without a history of hypertension diagnosis. Food items reported in a one-day 24-hour recall were categorized on the basis of the NOVA (not an acronym) food classification criteria. UPF consumption was estimated as the contribution to total energy intake. Elevated BP was defined as systolic BP ≥120 mmHg or diastolic BP ≥80 mmHg. The independent association between UPF consumption and elevated BP was assessed by multivariable logistic regression analysis. Results: The upper tertile of UPF consumption was significantly associated with elevated BP compared with the lower tertile, after adjusting for potential confounders. A linear trend was observed for elevated BP across the tertiles of the dietary energy contribution of UPF. Similar results were found in stratified analyses by age group, smoking, obesity, and overall dietary quality. However, a marginal level of association was found in some subgroups, current smokers, and non-obese adults. Conclusions: The dietary energy contribution of UPF consumption was positively associated with increased prevalence of elevated BP, and these findings suggest that lowering UPF consumption might help prevent BP elevation.

Investigation of the Contributions of Creep and Thermal Fatigue to Failure of a High-Intermediate Pressure Steam Turbine Casing

  • Lee, Jaehong;Jung, Nam-gun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2020
  • The contribution of damage mechanisms to failure of steam turbine casing made of Cr-Mo-V steel was investigated. Creep-fatigue interaction on the HP side corner of turbine casing was revealed as the root cause of the catastrophic failure performed by metallurgical analysis. The steady-state pressure and transient thermal stress were analyzed based on the actual operating condition of the thermal plant. Damage of creep-fatigue interaction to crack initiation was evaluated with multiaxial effects. The contribution ratio of creep and fatigue to the crack initiation was estimated to 3:1. Temporary geometrical correct action with repair weld was executed. For long-term operation, design improvement of casing equipment for creep resistance should be needed.

Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test (엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석)

  • Yang, In-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

Assessment of the Contribution of Risk Factors that Cause Cardiovascular Disease in Koreans (한국인의 심혈관질환 발생을 유발하는 위험인자들의 기여도 평가)

  • Cho, Sang-Ok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.592-602
    • /
    • 2020
  • This study examined the contribution of the risk factors that cause cardiovascular disease in Koreans. The subjects were 20,012 adults aged 30~74 years who were enrolled from the 2005~2013 Korean National Health and Nutrition Examination Survey, had filled the risk factors data, and had no cardiovascular disease history. Data analysis was conducted using SAS 9.3, and a weighted composite sample design analysis was performed. The contribution was obtained by applying a squared semi-partial correlation. As a result, they were higher in the order of age (63.9%), smoking (17.3%), systolic blood pressure (7.9%), diabetes (6.9%), antihypertensive medication use (3.0%), and BMI (0.9%) in men. In women, the contributions were in the order of age (54.1%), systolic blood pressure (23.5%), diabetes (13.6%), antihypertensive medication use (5.1%), smoking (3.1%), and BMI (0.6%%). According to age bracket analysis, smoking (51.8~33.7%) was the biggest risk factor, followed in order by age (26.6%) in their 30s and systolic blood pressure (17.3~21.0%) in those older than 40 years in men. In women, the systolic blood pressure (56.2~40.5%) was the main contributor to the risk factors, followed by age (24.0%) in their 30s and diabetes (13.6~32.6%) in those older than 40 years. The contribution of the income level was similar. Therefore, to prevent cardiovascular disease, various programs that reflect the contributions of the risk factors should be developed. Moreover, it is recommended to use the results shown in this study as basic data.

A Study on the Pulsation Pressure Reduction for the Hydraulic System of Medium-large Excavator (중대형 굴삭기 유압시스템의 압력 맥동 저감 연구)

  • Kim, Young-Hyun;Joo, Won-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • With hydraulic noise test facility, a variety of tests were performed to investigate the pulsation pressure generation mechanism and its transmission characteristics and to derive the noise control methodology. Many experiments were carried out by changing average pressure, flow rate, pump speed, hose length and MCV spool condition. From the test results, the correlations between pulsation pressure and other design parameters, such as static pressure, flow rate and MCV spool opening area and length of hose, were found out. And also each contribution factors were evaluated from the regression analysis. By changing hose length, the pulsation pressure resonance phenomenon was investigated. In order to find out the pulsation pressure reduction measures pulsation pressure analysis, such as pulsation pressure of hydraulic pump itself and pulsation pressure of hydraulic system, by using AMESim were studied. In addition hydraulic silencer was developed based on the Helmholtz resonator. And its performance was evaluated by installing the silencer at the excavator.