• 제목/요약/키워드: Pressure armor layer

검색결과 3건 처리시간 0.017초

Crushing study for interlocked armor layers of unbonded flexible risers with a modified equivalent stiffness method

  • Ren, Shaofei;Liu, Wencheng;Song, Ying;Geng, Hang;Wu, Fangguang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.521-529
    • /
    • 2019
  • Interlocked armor layers of unbonded flexible risers may crush when risers are being launched. In order to predict the behavior of interlocked armor layers, they are usually simplified as rings with geometric and contact nonlinearity ignored in the open-literature. However, the equivalent thickness of the interlocked armor layer has not been addressed yet. In the present paper, a geometric coefficient ${\gamma}$ is introduced to the equivalent stiffness method, and a linear relationship between ${\gamma}$ and geometric parameters of interlocked armor layers is validated by analytical and finite element models. Radial stiffness and equivalent thickness of interlocked armor layers are compared with experiments and different equivalent methods, which show that the present method has a higher accuracy. Furthermore, hoop stress distribution of interlocked armor layer under crushing is predicted, which indicates the interlocked armor layer can be divided into two compression and two expansion zones by four symmetrically distributed singular points.

동적 파랑에 의한 침투류가 사석경사식 방파구조물의 안정성에 미치는 영향 (Effect of Wave-Induced Seepage on the Stability of the Rubble Mound Breakwater)

  • 황웅기;김태형;김도삼;오명학;박준영
    • 한국지반공학회논문집
    • /
    • 제34권3호
    • /
    • pp.13-27
    • /
    • 2018
  • 사석경사식 방파제의 안정성에 있어 파랑에 의한 사석마운드내의 침투흐름의 영향이 연구되었다. 침투흐름은 일반적으로 태풍시 방파제 주변 수위차에 의해 발생된다. 기존 사석마운드의 안정해석법은 정적해석으로 활동면 상의자중(콘크리트블록, 사석, 필터, 보호층)에 의한 수직력과 콘크리트 블록에 작용하는 파압에 의한 수평력(Goda 식으로 산정)의 힘의 평형조건으로 결정된다. 그러나 이 정적방법은 사석마운드 내의 파랑에 의한 침투흐름을 고려할 수 없다. 이런 침투흐름은 사석마운드의 안정성을 감소시킬 수 있다. 본 연구에서는 침투 작용시 사석경사식 방파제의 안정성에 대해 CFD 프로그램(OpenFOAM)과 한계평형해석법(GeoStudio)을 이용하여 검토하였다. 수치해석결과 침투로 인해 사석경사식 방파제의 안정성이 감소하는 것으로 나타났다. 또한 수치해석 결과는 사석마운드의 안정성이 시간에 따라 변하는 것을 보여주었다. 특히 파가 방파제를 월류하고 침투류에 의해 상치콘크리트 측면과 하부에 강한 양압력과 사석마운드 내부에 간극수압이 크게 발생하는 시점에 가장 불안정 상태를 보이는 것으로 나타났다. 따라서 동적 파랑에 의한 침투류의 영향을 고려한 동적해석도 정적해석과 함께 검토할 필요가 있다.

Research of Diffusion Bonding of Tungsten/Copper and Their Properties under High Heat Flux

  • Li, Jun;Yang, Jianfeng
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.14-14
    • /
    • 2011
  • W (tungsten)-alloys will be the most promising plasma facing armor materials in highly loaded plasma interactive components of the next step fusion reactors due to its high melting point, high sputtering resistance and low deuterium/tritium retention. The bonding technology of tungsten to Cu alloy was one of the key issues. In this paper, W/CuCrZr diffusion bonding has been performed successfully by inserting pure metal interlay. The joint microstructure, interfacial elements migration and phase composition were analyzed by SEM, EDS, XRD, and the joint shear strength and micro-hardness were investigated. The mock-ups were fabricated successfully with diffusion bonding and the cladding technology respectively, and the high heat flux test and thermal fatigue test were carried out under actively cooling condition. When Ni foil was used for the bonding of tungsten to CuCrZr, two reaction layers, Ni4W and Ni(W) layer, appeared between the tungsten and Ni interlayer with the optimized condition. Even though Ni4W is hard and brittle, and the strength of the joint was oppositely increased (217 MPa) due primarily to extremely small thicknesses (2~3 ${\mu}m$). When Ti foil was selected as the interlayer, the Ti foil diffused quickly with Cu and was transformed into liquid phase at $1,000^{\circ}C$. Almost all of the liquid was extruded out of the interface zone under bonding pressure, and an extremely thin residual layer (1~2 ${\mu}m$) of the liquid phase was retained between the tungsten and CuCrZr, which shear strength exceeded 160 MPa. When Ni/Ti/Ni multiple interlayers were used for bonding of tungsten to CuCrZr, a large number of intermetallic compound ($Ni_4W/NiTi_2/NiTi/Ni_3T$) were formed for the interdiffusion among W, Ni and Ti. Therefore, the shear strength of the joint was low and just about 85 MPa. The residual stresses in the clad samples with flat, arc, rectangle and trapezoid interface were estimated by Finite Element Analysis. The simulation results show that the flat clad sample was subjected maximum residual stress at the edge of the interface, which could be cracked at the edge and propagated along the interface. As for the rectangle and trapezoid interface, the residual stresses of the interface were lower than that of the flat interface, and the interface of the arc clad sample have lowest residual stress and all of the residual stress with arc interface were divided into different grooved zones, so the probabilities of cracking and propagation were lower than other interfaces. The residual stresses of the mock-ups under high heat flux of 10 $MW/m^2$ were estimated by Finite Element Analysis. The tungsten of the flat interfaces was subjected to tensile stresses (positive $S_x$), and the CuCrZr was subjected to compressive stresses (negative $S_x$). If the interface have a little microcrack, the tungsten of joint was more liable to propagate than the CuCrZr due to the brittle of the tungsten. However, when the flat interface was substituted by arc interfaces, the periodical residual stresses in the joining region were either released or formed a stress field prohibiting the growth or nucleation of the interfacial cracks. Thermal fatigue tests were performed on the mock-ups of flat and arc interface under the heat flux of 10 $MW/m^2$ with the cooling water velocity of 10 m/s. After thermal cycle experiments, a large number of microcracks appeared at the tungsten substrate due to large radial tensile stress on the flat mock-up. The defects would largely affect the heat transfer capability and the structure reliability of the mock-up. As for the arc mock-up, even though some microcracks were found at the interface of the regions, all microcracks with arc interface were divided into different arc-grooved zones, so the propagation of microcracks is difficult.

  • PDF