• 제목/요약/키워드: Pressure Wave

검색결과 2,082건 처리시간 0.037초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

건강한 너구리(Nyctereutes procyonoides)들의 심전계 지표에 대한 평가 (Evaluation of Electrocardiographic Index in Healthy Raccoon Dogs (Nyctereutes procyonoides))

  • 홍원우;김종택;양동근;남효승;현창백
    • 한국임상수의학회지
    • /
    • 제30권6호
    • /
    • pp.456-458
    • /
    • 2013
  • 포획된 건강한 너구리들의 심전도의 기준값을 평가하는 것이 본 논문의 주된 목적이다. 41마리의 방목되고 있는 다 자란 너구리들이 강원대학교 야생동물구조센터에 의해 구조되었으며 본 논문에 이용되었다. 어떠한 화학적 보정도 사용하지 않고 6-유도 심전도를 측정하였다. 평균 심박수는 $146.10{\pm}43.31$ 박동수/분 이었다(95% 신뢰구간 132.84~159.36 박동수/분). 평균 호흡수는 $35.73{\pm}11.56$ 호흡수/분 이었다(95% 신뢰구간 32.19~39.27 호흡수/분). 평균 수축기 압력은 $136{\pm}29.26mmHg$ 이었다(95% 신뢰구간 127.99~145.91 mmHg). 모든 너구리들의 심전계의 특징들을 또한 평가하였다. P-파의 평균 너비와 높이는 $38.2{\pm}4.0ms$ (범위 28-40 ms) 와 $0.128{\pm}0.039mV$ (범위 0.09~0.20)이었다. QRS파의 평균 너비와 높이는 $48.5{\pm}7.2ms$ (범위 36-60 ms) 와 $1.330{\pm}0.650mV$ (범위 0.15~2.30)이었다. 평균전기축 (QRS)은 $-91^{\circ}{\sim}+96^{\circ}$ ($10^{\circ}{\sim}60^{\circ}$; 95% 신뢰구간)이었다. 평균 교정 QT 간격(QTc)은 $273.7{\pm}32.7ms$ (범위 212-333 ms)이었고, PR간격은 $76.1{\pm}10.0ms$ (범위 50-82 ms)이었다. 본 논문은 포획된 건강한 너구리들의 심전도(ECG)의 기준값을 제공하는 최초의 논문이다.

Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가 (Evaluation of cardiac function by tissue Doppler imaging in children with cancer)

  • 김여향
    • Clinical and Experimental Pediatrics
    • /
    • 제49권4호
    • /
    • pp.417-423
    • /
    • 2006
  • 목 적 : 항암제와 방사선 치료의 개발, 골수나 조혈모세포 이식 기회의 증가로 소아 백혈병과 고형 종양을 가진 환아들이 장기 생존하게 되면서 치료에 따른 장기 부작용, 특히 심장 독성에 크게 관심을 가지게 되었다. 항암제에 의한 심장 독성을 파악하는데 가장 적절한 방법은 비침습적이면서 정량적으로 측정할 수 있는 심초음파라고 할 수 있다. 본 연구에서는 이미 소아암으로 진단을 받고 치료를 받는 중이거나 치료를 종료한 환아들을 대상으로 조직 도플러 영상을 사용하여 심실 기능을 평가하고, 향후 동질환의 환아에서 조기 및 후기 심독성을 조기에 발견하기 위한 방법으로 반복적인 조직 도플러 영상을 적용하는데 기여하고자 하였다. 방 법 : 2005년 4월 1일부터 7월 1일까지 계명대학교 동산의료원 소아 종양 크리닉을 방문한 항암치료 중이거나 항암치료 종료된 환아 23명을 대상으로 하였다. 전체 대상 환아군(1군)은 단축 분획 29% 이상(2군), 28% 이하의 군(3군)으로 나누고, anthracyclin 사용군(4군)과 미사용군(5군)으로 다시 나누었다. M-mode와 간헐파 도플러를 이용하여 단축 분획, 구혈률, 승모판막으로 유입되는 혈류의 E, A 속도, DT, IVRT를 측정하였고, 조직 도플러 영상을 이용하여 심첨 4, 2 방도에서 중격, 전벽, 하벽, 측벽의 기저부, 중간, 심첨 부위의 Sm, Em, Am 속도를 측정하였다. 측정한 값을 이용하여 modified Tei index, E/A, E/Em ratio를 구하였다. 결 과 : 환아의 평균 나이는 8년 4개월이었고 남아 12명, 여아 11명이었다. 항암제 중 anthracyclin을 사용한 환아(4군)는 13명이었고, 방사선 치료를 받은 환아는 4명이었으며 단축 분획이 28% 이하인 환아(3군)는 6명이었다. 대조군의 평균 나이는 6년 6개월이었고 남아 6명, 여아 3명이었다. 환아군과 대조군간에 성별, 나이에 있어서 유의한 차이는 없었다. 대조군과 1군의 E/Em ratio는 $7.06{\pm}1.64$, $6.46{\pm}1.85$로 두 군간에 P<0.05로 의미있는 차이가 있었으나 다른 측정값들은 유의한 차이가 없었다. 대조군과 2, 3, 4, 5군간에도 E/Em ratio는 P<0.05로 의미있는 차이가 있었다. 2, 3군과 4, 5군간에는 측정값들의 군간의 유의한 차이가 없었다. 결 론 : 좌심실 평균 이완기압을 반영한다고 알려져 있는 E/Em ratio에서 대조군과 항암 치료 군간에 차이가 확인됨으로써 항암 치료 이후의 심장 기능 부전은 수축기 기능 변화가 아닌 이완기 기능 변화가 먼저 오는 것을 알 수 있었다. 심장 이완기 기능을 평가하는 간헐파 도플러 측정값들에서는 두 군간에 차이가 없음으로 이완기 기능을 평가하는데는 조직 도플러 영상을 이용하는 것이 더 민감한 방법이었다. 따라서 항암 치료 이후에도 장기적으로 관심을 가지고 심장 기능에 대한 잦은 추적 관찰이 필요하겠고, 추적 관찰하는 방법으로는 조직 도플러 영상을 이용한 심초음파 검사가 비침습적이고 간편하며 유용한 방법일 수 있다.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

DDInSAR 기반의 빙하연구를 위한 동남극 테라노바 만의 조위모델 정밀도 평가 (Accuracy Assessment of Tide Models in Terra Nova Bay, East Antarctica, for Glaciological Studies of DDInSAR Technique)

  • 한향선;이주한;이훈열
    • 대한원격탐사학회지
    • /
    • 제29권4호
    • /
    • pp.375-387
    • /
    • 2013
  • 이중차분간섭기법(Double-Differential Interferometric SAR; DDInSAR)을 이용하여 빙하의 조위반응을 정확히 해석하기 위해서는 극지 해양에 대한 조위모델의 정밀도 평가가 수행되어야 한다. 이 연구에서는 동남극 테라노바 만에서 TPXO7.1, FES2004, CATS2008a, Ross_Inv 조위모델의 정밀도를 평가하기 위해 2년 동안 획득된 16쌍의 one-day tandem COSMO-SkyMed SAR 간섭영상으로부터 생성한 120개의 DDInSAR 영상과 수압식 파고계로 11일 동안 실측한 조위를 이용하였다. 먼저, DDInSAR 영상과 조위모델로 추출된 조위의 이중차분값(${\Delta}\dot{T}$)을 비교하였으며, 실측조위와 조위모델의 조위(T), 그리고 실측조위와 조위모델 조위의 24시간 차분값($\dot{T}$)을 비교하였다. ${\Delta}\dot{T}$와 T, $\dot{T}$의 평균제곱근오차(root mean square error; RMSE)는 조위모델의 역기압 효과(inverse barometer effect; IBE) 보정 후에 감소하였고, 이로부터 조위모델의 IBE는 필수적으로 보정되어야 함이 확인되었다. $\dot{T}$${\Delta}\dot{T}$는 T보다 작은 RMSE를 보였다. 이는 SAR 간섭쌍의 시간차(24시간) 동안의 차분값인 에 조위모델과 실측조위의 평균해수면 오차와 조위모델이 사용하는 조화상수 중 $S_2$, $K_2$, $K_1$, $P_1$의 오차가 상쇄되기 때문이다. 따라서 IBE가 보정된 조위모델의 $\dot{T}$${\Delta}\dot{T}$가 DDInSAR 기법에 사용될 수 있음을 확인하였다. 단기간 실측된 조위로는 최적의 조위모델 선정에 어려움이 있었으나, DDInSAR를 이용한 정밀도 평가에 의하면 Ross_Inv가 4.1 cm의 RMSE를 보여 테라노바 만의 DDInSAR에 가장 적합한 조위모델로 확인되었다.

Tension Leg Platform의 동적응답에 관한 연구 (Dynamic Response of Tension Leg Platform)

  • 여운광;편종근
    • 대한토목학회논문집
    • /
    • 제5권1호
    • /
    • pp.21-30
    • /
    • 1985
  • Tension Leg Platform (TLP)이란 평행위치로부터 일정 범위내에서 움직임으로 인하여 외 력의 효과를 완화시키는 compliant 구조물인 동시에, 기인장력을 받고 있는 연직 anchor cable 이 있으므로 부력이 자중을 초과하게 되는 안정한 platform 이다. 일반적으로 부체는 해상조건이 험할수록, 그리고 수심이 깊어질수록 동요가 심해지는데 TLP는 기인장 cable로 인하여 심해에서도 비교적 동요가 작아서 최근 대수심구조물의 총아로 각광받고 있다. 일찌기 Paulling 등이 TLP 거동의 예측을 위하여 수정된 Morison 방정식을 사용하는 선형동유체력합성방법을 발표하였다. 그러나 만일 TLP의 각 부재가 Morison 방정식의 가정이 성립할 수 없을 정도로 크다면 새로운 해석이 필요하다 하겠다. 일본의 Tanaka는 이런 경우에 McCamy-Fuchs 이론의 결과치를 이용하였으나, 완전한 해석이라기 보다는 일종의 간편법이라 하겠다. 본고에서는 큰 배수용적을 가진 연직부체가 있고, 이론적 해석의 결과를 검토해 볼 수 있는 수리모형 실험 결과가 있는 Deep Oil Technology (DOT) 회사의 TLP를 대상으로 하였다. 이 TLP는 부력을 전담하고 있는 연직축대칭 원통과 이들을 연결하고 있는 세부재로 이루어져 있어 축대칭부분에는 축대칭 Green 함수를 사용하여 동유체력을 구하고 세부재는 종래의 수정된 Morison 방정식의 항력항을 선형화하여 동유체력을 구하였다. 그리하여 부재의 각 미소부분에서 구한 힘들을 TLP의 중심에 원점을 둔 좌표계로 옮겨 동적응답을 구한 것이다. 본 해석에서 부재 상호간의 작용은 무시하였으며 단지 부재간의 거리효과만 고려하였다. 따라서 사용된 좌표계는 전체 (Global) 좌표계, 지점 (Local) 좌표계 및 파랑 (Wave) 좌표계 등이었고 각 좌표계간의 변환식이 필요하였다. 전체적인 해석정도는 선형이론으므로 케이블의 강성도 역시 선형적으로 구하였으며, 앞서 언급했다시피 Morison 방정식의 비선형항인 항력항은 Fourier 해석으로 선형화 하였다. 이러한 Fourier 해석은 잘 알려져 있는 Lorentz 원리와 같다고 볼 수 있다. 세부재의 경우 접선력은 무시하였고 수입자의 운동에 의한 부채에 대한 수직력만 고려하였다. 여기서 파랑좌표계에서 지점좌표계로의 좌표변환이 주의를 요하고 있다. 이제 이렇게 구한 각 힘들을 전체좌표 계에서 6개의 자유도별로 운동방정식에 대입하면 각 자유도별 동적응답이 구하여지는 것이다. DOT TLP의 Surge mode에 대한 동적응답을 실험치와 비교하여 본 결과, 세부재에 대한 고려를 뺄 수 없음을 알 수 있었다. 이는 연직축대칭 부체의 크기가 그리 크지 않으므로 인한 것이며, TLP의 원형의 경우에는 보다 더 관성력이 지배적일 것으로 사료된다.

  • PDF

조직 도플러 영상을 이용한 선천성 심장병 수술 전후의 단기 심기능 평가 (Evaluation of short-term cardiac function by tissue Doppler imaging in pre and postoperative period of congenital heart disease)

  • 이준화;김여향;현명철;이상범
    • Clinical and Experimental Pediatrics
    • /
    • 제50권5호
    • /
    • pp.476-483
    • /
    • 2007
  • 목 적 : 선천성 심장병을 가진 소아에서 체외 심폐 순환기를 이용한 개심술을 시행한 후 좌 우심실의 기능의 변화를 조직 도플러 영상을 이용하여 측정하고, 이를 개심술 이전과 비교함으로써 수술 이후의 심실 기능 변화를 살펴 보고자 하였다. 방 법 : 2005년 1월부터 2005년 12월까지 선천성 심장병으로 경북대학교병원 소아과에 입원하여 심초음파 및 진단적 심도자술 검사를 받은 후 개심술을 시행한 환자 총 78명 중 수술 전과 수술 후 1개월에서 3개월 사이에 심초음파를 시행하고, 두 번 모두 조직 도플러 영상이 기록된 환자 32명을 대상으로 하였다. 전체 환자군은 다시 3군으로 나누었는데, 좌심실 용적 과부하를 가지는 1군, 우심실 용적 과부하를 가지는 2군, 우심실 압력 과부하를 가지는 3군으로 분류하였다. 간헐파 도플러를 이용하여 승모판과 삼첨판 유입 혈류의 E, A 최대 속도를 측정하고, 조직 도플러 영상을 이용하여 심첨 4방도와 2방도에서 심실 중격, 승모판륜 및 삼첨판륜 외벽, 좌심실 후벽과 전벽의 기저부에서 Sm, Em, Am을 측정하였으며, E/Em을 구하였다. 결 과 : 개심술 당시 대상 환자 군의 평균 나이는 27개월(1개월-156개월)이었고, 남자 14명, 여자 18명이었다. 개심술을 시행한 심장병으로는 심실 중격 결손 13명, 심방 중격 결손 7명, 방실 중격 결손 3명, 단순 폐동맥 협착 2명, 및 활로씨 4징 7명이었다. 좌심실 용적 과부하 군인 1군의 승모판륜 외벽의 E/Em, 삼첨판륜 외벽의 Sm, Em, Am, 심실 전벽의 Em, Am, 우심실 용적 과부하 군인 2군의 삼첨판륜 외벽의 Sm, Em, Am, 심실 전벽의 Sm, Em, 심실 중격과 후벽의 Em, 우심실 압력 과부하 군인 3군의 삼첨판륜 외벽의 Sm, Em, Am, 심실 전벽의 Am 값들도 수술 전과 비교하여 수술 후에 통계학적으로 의미있는 감소가 있었다. 결 론 : 선천성 심장병 환자의 수술 전과 수술 후의 조직 도플러 영상 측정값을 비교하였을 때 모든 환자 군에서 삼첨판륜 외벽의 Sm, Em, Am 값의 감소를 보이고, 좌심실 용적 과부하군에서는 좌심실 이완기압을 반영한다고 할 수 있는 승모판륜 외벽의 E/Em 값이 수술 전에 비해 수술 후에 통계학적으로 유의한 감소를 보였다. 이들은 체외 심폐 순환기를 이용한 개심술의 심장에 대한 영향 및 선천성 심장병의 교정 후의 용적, 압력의 변화 영향을 모두 반영하는 것으로 생각된다. 그러나 이러한 결과가 어느 정도까지 체외 심폐 순환기를 이용한 개심술에 의한 영향을 반영하는지에 대해서는 더 많은 연구가 필요할 것으로 생각된다.

본초 광물로서의 활용을 위한 산지별 전기석의 광물학적 연구 (Mineralogical Studies of the Tourmaline for Medicinal Applications by Production Localities)

  • ;김선옥;박희율;박맹언
    • 자원환경지질
    • /
    • 제51권4호
    • /
    • pp.345-358
    • /
    • 2018
  • 이 연구는 전기석이 본초 광물의 활용 가능성을 평가하기 위하여 중국 산동성 흑색 전기석 5종, 브라질 미나스 제라이스(Minas Geraris)광산의 흑색 및 핑크색 전기석 2종, 한국 대유광산 흑색 전기석 1종을 대상으로 전자탐침미세분석, X-선 회절분석, 유도결합플라스마 분광방출분석, 퓨리에변환 적외선분광분석, 원적외선 분석, 핵자기공명분석 및 물-전기석 반응에 따른 pH-DO 변화를 수행하였다. 또한, 전기석 찜질방의 온열효과와 전기석 분말을 첨가한 비누가 피부에 미치는 영향을 검토하였다. 연구에 사용된 전기석 시료들은 철과 알루미늄 및 붕소 함량이 높은 유형으로 분류되며, 칼슘, 나트륨, 칼륨, 철과 붕소 함량변화는 전기석의 고용체 특성을 반영한다. $CaO/(CaO+Na_2O)$와 MgO/(FeO+MgO) 함량비는 높은 정(+)의 상관관계를 갖는다. 전기석 분말과 증류수와의 반응에서 DO값은 반응시간의 경과에 따라 낮아지며, DO=10에서 안정된다. pH는 6시간까지 증가되고, 24시간 이후에는 대체적으로 pH=8에서 안정된 상태를 유지한다. 전기석은 단파장에서 흡수 스펙트럼의 강도와 투과율이 낮아지며, 흡수 스펙트럼의 파장과 강도는 구성 원소의 함량과 결정학적 특징에 따라 달라진다. 특히, 철의 함량증가는 방사량을 감소시키는 원인이 되는 것으로 확인되었다. 전기석의 철 함량과 원적외선 방사량의 상관관계는 높은 정(+)의 상관성을 가지며, 알루미늄과 마그네슘 함량은 부(-)의 상관관계를 나타낸다. 증류수와 전기석 분말의 반응은 $^{17}O-NMR$ 반치폭을 감소시키는 것으로 확인되었다. 전기석에 의한 고온 찜질방(약 $100^{\circ}C$ 사우나)에서의 온열효과는 체온을 $0.5-1.5^{\circ}C$ 정도 높이며, 맥박은 평균 12회, 혈압은 10mg Hg 상승한다. 전기석 비누는 피부에 매우 좋은 효과를 나타내며, 알레르기와 아토피 등의 문제성 피부에서 보통이상의 개선 효과를 갖는 것으로 확인되었다.

조파저항에서의 Neumann-Kelvin 문제에 대한 연구 (A Study on the Neumann-Kelvin Problem of the Wave Resistance)

  • 김인철
    • 수산해양기술연구
    • /
    • 제21권2호
    • /
    • pp.131-136
    • /
    • 1985
  • 코너에서의 특이점이 weak 표면 특이점이라면, 반잠수 반원에 대한 Neumann-Kelvin 문제는 코너에서 속도가 유계인 한 개의 최소특이해를 가진다. 그러나 왜 유계인 조건이 코너에서 부과되어야 하는가 하는 명백한 물리적 이유는 없다. 코너는 정체점이 되고 여기서 섭동속도는 전진속도와 같다. 그리고 코너에서의 선형화는 타당하지 않다. 그러나 우리는 이러한 것을 무시하고 코너에서 이 점을 가져야만 한다고 제안한다. 따라서 이것이 코너에서 약하거나 강한 특이점을 가지는 섭동방정식의 해를 찾기 위한 적당한 이유이다. 그러나 어떤 특이점이 적당한가를 결정하는 명확한 방법은 없다. Ursell은 그의 연구에서 (19)식의 p와 q를 0으로 두어 유일해를 결정하기도 하였다. Suzuki는 자유표면에 대하여 에너지 보존을 취하여 유일해를 확정시키는 부가적인 조건을 제시하기도 하였다. G (ξ,η;x, y)는 y>0일 때 (x, y)에서 소스를 나타내며, 실제로 G (ξ,η;a, 0)는 weak 표면특이점이다. 최소특이해에 대한 표현은 (11)로부터 추론할 수 있고 각각의 코너에서 불연속 weak 표면특이점과 함께 소스의 연속적인 분포로 구성된다. Maruo는 세장체 이론의 적응으로부터 유도된 근사방법을 소개하였는데 이것은 Neumann-Kelvin 문제의 Kernel 함수에 대한 근사와 기본적으로 같다. 비록 왜 최소특이해가 2차원에서 택해져야 하는가에 대한 명확한 물리적인 이유는 없더라 해도, 어떻게 상응하는 유계조건을 3차원에도 적용할 수 있는가 하는 것이 최근 연구과제 중의 하나다. Ursell의 연구에 의한 경험은 앞으로 완전한 비점성 3차원 문제의 취급에 사용될 것이고, Maruo의 세장선 근사와는 다른 방법으로 3차원 Neumann-Kelvin 문제를 해석할 수 있을 것이다.의 수는 오히려 약간 증가하는 것으로 보이며, 고농도처리시 이들 값이 다시 감소하는 것은 Chain들의 운동이 급격해지면서 일부 비정 chain들이 절단되어서 결과적으로 T.M. 및 T.T.M.의 수는 오히려 약간 증가하는 것으로 보이며, 고농도처리시 이들 값이 다시 감소하는 것은 Chain들의 운동이 급격해지면서 일부 비정 Chain들이 절단되어서 결과적으로 T.M. 및 T.T.M.의 수가 감소하기 때문이라 생각되었다.각되었다.n 4 cases by ultrasonography. And ultrasonography could not reveal collaterals, arteriovenous shunt and thread and streaks sign.순에 최대 밀도를 나타내였고, 10월 중순 부터는 채집할 수 없음을 알았다.위분지 이상에서 3%로 자엽절 2분지의 비중이 특히 컸다.스 접종 8일 후의 중장원동세포내에서 A형 및 B형 봉입체가 형성되었음을 확인하였다. 10. FV감염 중장조직세포의 전자현미경 관찰에서는 바이러스 접종 5일 후에 배상세포의 'cytoplasmic wall'이 비대해지고 그 내부에 virus-specific vesicle이 형성되었으며, 바이러스 접종 8일 후에는 virus-specific vesicle, 바이러스 입자, linear structure, tubular structure 및 전자밀도가 높은 matrix 등의 바이러스 감염에 대한 특이적인 구조물이 배상세포의 세포질에서 관찰되었으며, microvilli내에서 바이러스 입자의 존재도 확정되었다. 특히 virus-specific vesicle 주위에서는 전자밀도가 높은 구형의 바이러스 입자 유사체가 관찰되었는데, 이것은 virus-specific vesicle 주위에서 바이러스 조립이 일어나는 것을 추정된다

  • PDF

항아리 형태 젊은 초신성 잔해의 동력학 (Dynamics of Barrel-Shaped Young Supernova Remnants)

  • 최승언;정현철
    • 한국지구과학회지
    • /
    • 제23권4호
    • /
    • pp.357-368
    • /
    • 2002
  • 본 연구에서는 항아리 형태 젊은 초신성 잔해의 동력학을 설명하기 위해 분출물의 동력학적 효과를 고려하였다. 분출물과 성간 물질 사이에 존재하는 접촉불연속면에서 레일라-테일러(R-T)불안정에 기인한 자기장의 증폭호과가 고려되었다. 우주선 입자의 가속을 가정함으로서 합성전파 모형을 만들 수 있었으며 관측과의 비교를 위해 방위각을 따른 전파세기의 비(A)를 계산하였다. R-T불안정의 결과로 자란 가지의 경계면에서 압축, 전단, 인장의 결과로 충격파 후면의 자기장은 증폭되었다. 불안정의 시간에 따른 변화는 분출물의 감속에 민감하게 의존하며 초신성 잔해의 진화와 밀접히 관계됨을 볼 수 있었다. 자기장의 세기는 초기에 급격히 증가하며 역 충격파가 분출물의 등밀도지역으로 들어감에 따라 감소되었다. 그러나 이와 같은 초기 자기장 증폭의 효과는 초신성 잔해의 후기까지 남아 있음을 볼 수 있었다. 증폭된 자기장 영역에서 적도지역과 극지역의 자기장의 세기의 비는 최대 7.5까지 이를 수 있었다. 이와 같은 자기장의 증폭은 방위각에 따라 매우 큰 전파세기의 비를 만들 수 있었다(A=15). 증폭된 자기장의 세기는 수치계산의 분해능에 매우 민감함을 알 수 있었다. 본 연구에서는 우주선 입자의 가속효과가 자기장과 충격파 면이 이루는 각도에 의존한다는 가정 없이도 자기장의 증폭효과가 관측된 항아리 형태의 젊은 초신성 잔해를 만들 수 있음을 보였다. 그러나 이와 같은 기작이 효과적이기 위해서는 초신성 잔해 주위의 자기장이 잘 정열되어 있어야 한다. 항아리 형태의 젊은 초신성잔해의 수가 적게 관측되는 것은 이와 같은 조건이 성간에서 잘 이루어지지 않음을 의미한다.OH radical의 생성이 활발해져, $CH_4$의 소멸이 촉진되었을 가능성이 큰 것으로 나타났다. 전체 $CH_4$의 일평균 농도를 이용한 장주기적 추세에 대한 분석결과에 따르면, 국내의 두 관측지점들(무안, 태안)에서는 수일 주기의 농도 변화가 급격하게 이루어졌지만, 뚜렷한 계절적 주기는 발견하기가 어려웠다. 그런데 국외의 관측지점들에서는, 계절적 주기의 변화가 상대적으로 뚜렷하고 규칙적인 양상을 보여주었다. 지역별 $CH_4$ 농도간의 상관분석을 실시한 결과, 국내 두 지점들 간에는 양의 상관관계, 무안지역과 북반구의 관측점들과는 음의 상관관계를 보였다. 반면 남반구에 위치한 관측점들과는 양의 상관관계를 확인 할 수 있었다. $CH_4$ 농도의 장주기적 변화경향을 분석하기 위해, 단순회귀분석을 실시한 결과, $CH_4$ 농도의 증가율이 무안과 태안 지역에서 각각 연간 16.5, 14.8 ppb로 가장 높게 관측되었다. 관측점 주변에 복잡한 배출원의 작용이 가능하다는 점을 감안하여, 무안지역의 $CH_4$ 농도변화와 풍향과의 연계성을 비교해 보았다. 이 결과에 의하면, 동풍계열의 풍계가 나타날 때 고농도의 값이 나타났으며, 청정한 공기가 유입되는 남서풍의 풍계시에는 비교적 낮은 $CH_4$ 농도가 유지되었다. 이처럼 $CH_4$의 장주기적 분포특성은 연구대상지역의 복잡한 배출${\cdot}$소별작용과 연계되어 매우 다양하고 독특한 형태를 띠고 있음을 확인할 수 있었다.