• 제목/요약/키워드: Pressure Sensitive

검색결과 787건 처리시간 0.03초

Pressure Sensitive Paint의 성능비교 및 경사충돌분류의 압력장 측정 (Performance Comparison of Pressure Sensitive Paint and Pressure Field Measurement of Oblique Impinging Jet)

  • 이상익;이상준
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.1031-1038
    • /
    • 2002
  • The pressure sensitive paint (PSP) has recently received a considerable attention in the fields of aerodynamics and fluid mechanics as a new revolutionary optical technique to measure pressure fields on a body surface. In this study, the feasibility and effectiveness of the PSP pressure field measurement technique have been investigated experimentally. Seven different PSP formulations including two porphyrins(PtOEP and PtTFPP) and four polymers(Polystyrene, cellulous acetate butyrate, GP-197 and Silicon-708) were tested to check the performance and characteristics of each combination. The static calibration of each PSP formulation was carried out in a constant-pressure chamber. The PSP technique was applied to an oblique impinging jet flow to measure variation of pressure field on the impinging plate at on oblique jet angle of ${\theta}=60^{\circ}$. Pressure field images were captured by an 12bit intensified CCD(ICCD, $1K{\times}1K$)camera. As a result, the dynamic response of PSP depends on the oxygen permeability of polymer and the photochemical interaction between luminophore and polymer as well as the reaction of luminophore itself. The reaction of luminophore was changed by employing different polymers. In conclusion, Among 7 PSP formulation tested, the combination of PtTFPP and cellulous acetate butyrate show the best performance. In addition, the detail pressure field of an oblique high-speed impinging jet was measured effectively using the PSP technique.

저속 유동용 Pressure Sensitive Paint 기술개발과 응용 (Development of Pressure Sensitive Paint (PSP) Technique for Low-speed Flows and Its Application)

  • 강종훈;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.688-693
    • /
    • 2003
  • The PSP technique has been used to measure pressure distribution on a model surface quantitatively. The objective of this study is to develop PSP technique which can be applied to low-speed flows. Four different PSP formulations including two porphyrins (PtOEP and PtTFPP) and two polymers (Poly(TMSP) and RTV-118) were tested and the performance of each combination was checked. In the static calibration, the luminescent intensity of the PSP coatings was measured from 0kPa to 11kPa with 0.5, 1, 2kPa increments. Among 4 PSP formulations tested, the combination of PtOEP and RTV-118 shows the best performance. The PSP technique was applied to an oblique impinging jet to measure the pressure field distribution on the impinging plate.

  • PDF

백 프레셔가 압밀시험중 공소수압 발달에 미치는 영향 (Effects of Back Pressure on Pore Pressure During Consolidation Test)

  • 강병희
    • 한국농공학회지
    • /
    • 제14권4호
    • /
    • pp.2770-2776
    • /
    • 1972
  • The needs for reproducing in situ neutral pressure, and for having fully saturated specimens and pore pressure measuring system for consoildation testing were examined in respect to pore pressure development. undisturbed specimens of a sensitive development. undisturbed specimens of a sensitive marine soft clay were tested in the ANTEUS consolidometer with the application of four different magnitudes of back pressure(0,5, 40 and $70lb/in^2$) in order to investigate the effect of back pressure on pore pressure development during consolidation test. The effect of back pressure on pore pressure development during consolidation is striking for back pressure up to $40lb/in^2$) but, above this value, no measurable effects of back pressure variations on pore pressure development are evidenced.

  • PDF

PSP를 이용한 Cavity 후류의 전역적 압력분포 측정 (The Whole Region Pressure Measurement of Cavity Downstream using PSP Technique)

  • 김기수;전영진;서형석;변영환;이재우
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.317-321
    • /
    • 2007
  • PSP는 Pressure Sensitive Paint의 약자로 대기중의 산소량을 측정하여 전역적인 압력정보를 광학적으로 측정 할 수 있다. 본 연구에서는 PSP를 사용하여 jet injection 후류의 표면압력 분포를 알아보았다. 또한 Jet injection 5mm앞에 종횡비 1에서 4까지의 사각형 Cavity를 위치시켜 후류에 미치는 영향을 알아보았다. Jet injection 후류의 압력 분포는 Cavity의 전단층의 영향으로 Cavity가 없을 때와 비교해서 옆으로 넓게 퍼지면서 강도는 약해지는 모습을 보인다. 또한 Cavity의 종횡비가 커짐에 따라서 전단층의 크기가 커지고 그 영향이 커졌다. 측정된 압력은 압력공의 결과, CFD의 결과와 비교하였으며 근접한 값을 보였다.

  • PDF

부하 감응형 유압 펌프 제어 시스템의 특성 해석에 관한 연구 (A Study on the Characteristic Analysis of the Load-sensitive Hydraulic Pump Control System)

  • 이용주;이승현;송창섭
    • 한국정밀공학회지
    • /
    • 제17권4호
    • /
    • pp.148-154
    • /
    • 2000
  • In this study, the static and the dynamic characteristics of the load-sensitive hydraulic pump control systems of a hydraulic excavator were analyzed using the developed analysis tool. The results were compared with the experimental ones. To improve the static performance of the system, the system parameter effects on the controllable region and the pump pressure variation were studied. The parameters enhancing dynamic characteristics were also considered.

  • PDF

Thermo-sensitive lipid nanoparticles as a novel topical delivery system of retinol

  • Jee, Jun-Pil;Lee, Mi-Kyung;Kim, Chong-Kook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.425.2-425.2
    • /
    • 2002
  • The purpose of this study was to prepare thermo-sensitive solid-lipid nanoparticles (SLNs) with a lipid melted at human body temperature and to evaluate physicochemical properties of SLNs containing retinol. anti-wrinkle agent. as a model drug. SLNs were prepared using a high pressure homogenizing method. The SLNs were composed of retinol as a model drug. thermo-sensitive lipid (DS-CBS) as a lipid core. and egg phosphatidylcholine and Tween 80 as surfactants. Manufacturing variables such as homogenization pressure. (omitted)

  • PDF

PSP를 이용한 노즐벽면의 압력해석 (Pressure Analysis on the nozzle wall with PSP)

  • 김기수;배영우;이재우;변영환
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.409-412
    • /
    • 2005
  • 본 논문에서는 Pressure Sensitive Paint(이하 PSP)를 이용한 M=2.5 초음속 풍동의 노즐 벽면 압력 측정 과정을 보여주고, NASA Lewis Research Center에서 유사한 조건에서 수행한 실험결과와 비교하였다.

  • PDF

PSP 압력 측정 Calibration 시스템 구축 및 적용 (Application and Construction of PSP Calibration System)

  • 전영진;서형석;변영환;이재우
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.99-102
    • /
    • 2007
  • Pressure Sensitive Paint(PSP)는 압력에 반응하는 도료를 뜻한다. PSP를 이용하여 압력을 측정 하기 위해서는 paint calibration과 PSP를 도포한 모델의 풍동실험이 필요하다. PSP는 이 두 가지의 결과를 이용한 이미지의 후처리과정을 통하여 압력정보를 포함한 이미지를 얻을 수 있는 신기술이다. 본 연구에서는 PSP에 필요한 장치 및 설비들을 구성하고 PSP를 이용하여 calibration 실험을 실시하였다. 본 연구를 통해 얻어진 calibration chamber의 설계 및 제작 방법으로 진보된 calibration 시스템을 연구할 수 있는 능력을 배양하였다.

  • PDF

Highly Sensitive Stretchable Electronic Skin with Isotropic Wrinkled Conductive Network

  • Seung Hwan Jeon;Hyeongho Min;Jihun Son;Tae Kon Ahn;Changhyun Pang
    • 센서학회지
    • /
    • 제33권1호
    • /
    • pp.7-11
    • /
    • 2024
  • Soft-pressure sensors have numerous applications in soft robotics, biomedical devices, and wearable smart devices. Herein, we present a highly sensitive electronic skin device with an isotropic wrinkled pressure sensor. A conductive ink for soft pressure sensors is produced by a solution process using polydimethylsiloxane (PDMS), poly 3-hexylthiophene (P3HT), carbon black, and chloroform as the solvents. P3HT provides high reproducibility and conductivity by improving the ink dispersibility. The conductivity of the ink is optimized by adjusting the composition of the carbon black and PDMS. Soft lithography is used to fabricate a conductive elastic structure with an isotropic wrinkled structure. Two conductive elastic structures with an isotropic wrinkle structure is stacked to develop a pressure sensor, and it is confirmed that the isotropic wrinkle structure is more sensitive to pressure than when two elastic structures with an anisotropic wrinkle structure are overlapped. Specifically, the pressure sensor fabricated with an isotropic wrinkled structure can detect extremely low pressures (1.25 Pa). Additionally, the sensor has a high sensitivity of 15.547 kpa-1 from 1.25 to 2500 Pa and a linear sensitivity of 5.15 kPa-1 from 2500 Pa to 25 kPa.