• Title/Summary/Keyword: Pressure Ratio

Search Result 5,714, Processing Time 0.065 seconds

Abnormal Discharge Characteristics of Fluorescent Lamp

  • Lee, Chang-Ho;Kang, Jae-Kyung;Jang, Eun-Seok;Kim, Jae-Bum;Park, Joon-Ha;Shin, Jong-Keun;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1425-1427
    • /
    • 2009
  • In this paper, we investigated influence of gas pressure and gas mixing ratio on the abnormal discharge characteristics of fluorescent lamp. Abnormal discharge characteristics have been examined by changing inner gas pressure and mixing ratio. As the inner gas pressure and mixing ratio increase, the occurrence of abnormal discharge was delayed. It was found out that the occurrence of abnormal discharge is sufficiently delayed at the optimized inner gas pressure and mixing ratio.

  • PDF

A Study on the Proper Pore pressure ratio in Continuous Loading Consolidation tests (연속재하 압밀시험에서 적정 간극수압비에 관한 연구)

  • Chae, Sum-Sik;Lee, Song
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.271-276
    • /
    • 2002
  • Continuous loading is applied the sample has been developed to overcome some of the problems associated with the incremental loading consolidation test. Therefore, it is able to reduce the test time and provide a well defined the curve of effective stress versus strain due to continuous stress-strain points. Also, the constant rate of strain consolidation(CRSC) test has been accepted widely as a standard method in foreign countries because of its many advantages. However, in Korea the CRSC test has not been used in engineering practice and experimentally verified. Because there is not a precise criterion of testing despite consolidation characteristics are influenced on strain rate and Pore pressure ratio. Consequently, it is difficult to apply in engineering practice. In this study, artificial neural networks are applied to the estimation of th proper strain rate and pore pressure ratio of the CRSC test. This study shows the possibility of utilizing the artificial neural networks model of estimation of the strain rate and pore pressure ratio in the CRSC test.

  • PDF

Performance Analysis of an Air-Cycle Refrigeration System (공기사이클 냉동시스템의 성능해석)

  • Won, Sung-Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.9
    • /
    • pp.671-678
    • /
    • 2012
  • The objective of this study is to analyze theoretically the performance of an open air-cycle refrigeration system in which environmental concerns increase. The pressure ratio of the external compressor and efficiencies of the components that compose of the system are selected as important parameters. As the pressure ratio of the external compressor increases, the pressure ratio of the ACM compressor is determined high, the refrigerating temperature and capacity increase, the COP decreases, and the total entropy production rate increases. The effect of heat exchanger effectiveness and turbine efficiency on the performance are greater than that of the ACM compressor efficiency. Also the performance of the air-cycle refrigeration system with two heat exchangers has been enhanced like high COP and low total entropy production rate, compared to the system with one heat exchanger.

A study of area-ratio effect on self-ignition of high pressure hydrogen gas released in to a tube (면적비 변화에 따른 튜브 내 고압 수소 자발점화현상 연구)

  • Yoon, Hee;Lee, SangYoon;Jeong, Man Chul;Jeung, In-Seuck;Lee, Hyoung Jin
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.147-150
    • /
    • 2015
  • When high-pressure gas is suddenly leaked out into the air, unexpected ignition occurs without any external ignition source. Until now, there have been investigations on self-ignition of hydrogen by supplying high-pressure hydrogen gas into a tube. However the mechanism of hydrogen ignition is still unclear. This paper describes the area-ratio effect on hydrogen ignition by inserting a brass plate. The results show that the ignition phenomena differ as the area-ratio changed. Also, the rupture pressure for self-ignition has to be higher.

  • PDF

Numerical study of compression waves passing through two-continuous ducts (두 연속 덕트를 전파하는 압축파의 수치해석적 연구)

  • Kim, Hui-Dong;Heo, Nam-Geon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.823-831
    • /
    • 1998
  • In order to investigate the impulsive noise at the exit of high-speed railway tunnel and the pressure transients inside the tunnel, numerical calculations using a Total Variation Dimishing difference scheme were applied to axisymmetric unsteady compressible flow field. Some compression wave forms were assumed to model the compression wave produced in real high-speed railway tunnel. The numerical data were extensively explored to analyze the peak over-pressure and maximum pressure gradient in the pressure wavefront. The effect of the distance and cross-sectional area ratio between two-continuous ducts on the characteristics of the pressure waves were investigated. The peak over-pressure inside the second duct decreases for the distance and cross-sectional area ratio between two tunnels to increase. The peak over-pressure and maximum pressure gradient of the pressure wavefront inside the second duct increase as the maximum pressure gradient of initial compression wave increases. The present results were qualitatively well agreed with the results of the previous shock tube experiment.

Experimental Study on the PWM Pressure Control Characteristics of 2 Way Solenoid Valve (2방향 전자밸브 PWM압력제어특성의 실험적 비교연구)

  • 정헌술;박성진;김창완
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.107-111
    • /
    • 1997
  • Pressure control is possible by pulse width modulation signal driving a simple ON/OFF 2-way valve of hydraulic servo system. But it indices pressure fluctuation due to repeated on-off action and the pressure varies according to the duty ratio and carrier frequency. So mean pressure and ripple amplitude are arranged by experimental study as the driving signal change which decides the pressure characteristics. As the result selection criteria of the major design parameters may be established and the basic strategy to suppress the unnecessary flucturion may be provided for a hydraulic pressure control system.

  • PDF

Characteristics of the Base Pressure in High-Speed Jet Plume (고속제트 플럼에서의 기저압력 특성)

  • Lijo, Vincent;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.193-195
    • /
    • 2011
  • An abrupt increase of duct cross-section is frequently encountered in pressure reducing devices, valves of internal combustion engines and in gas pipelines. Supersonic flow in a rectangular duct passing an abrupt increase of cross-section is studied numerically. The behavior of base pressure of the dead-air region at sudden enlargement of the duct is clarified. This investigation concerns the determination of the base pressure, which is independent of the size of the enlarged part. Several flow patterns are identified with different enlargements according to the ratio between the downstream ambient pressure and the upstream reservoir pressure. Base pressure and the resulting shock-structure are highly depending on the size of duct enlargement. For a given duct, base pressure tends to minimum for a particular pressure ratio. In addition, the locations of secondary separation and reattachment points of the jet plume are found with respect to different duct enlargements.

  • PDF

Express Train Seat Discomfort Evaluation using Body Pressure and Anthropometric Data

  • Park, Se Jin;Min, Seung Nam;Lee, Heeran;Subramaniyam, Murali;Suh, Woo Sung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.3
    • /
    • pp.215-227
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate Korea's Honam express train's first- and second-class seat discomfort by using pressure measurement, subjective discomfort rating, and physical compatibility. Background: Over the years, the demand for an express train service is continually increasing. A comfortable ride is important to achieving passenger satisfaction. A train seat plays a significant role in fulfilling passenger seating comfort. With this in view, a field survey and pressure measurements were performed on the selected train seat. Method: The pressure ratio at the body-seat interface (thigh and buttock regions) was measured by the pressure mat system. The interface pressure ratio was calculated and compared. The subjective discomfort rating scale was used to evaluate the subjects' overall feeling. The dimensions of train seats were analysed according to the anthropometric and demographic characteristics of the population data from Size Korea. Results: The results highlighted that the interface pressure ratio was greater while participants sat on the second-class seat than the first-class seat in the left- and right-side thigh regions. Also the pressure ratio was greater for the participants in the 1st~25th percentile height groups (149.8~160.8cm). The subjects rated higher discomfort for the second-class seat than the first-class seat. The physical compatibility results showed that the second-class seat's breadth was inadequate for the 95th and 99th percentile male. Conclusion: Overall, interface pressure measurement, subjective discomfort score and physical compatibility results showed that the second-class seat was more uncomfortable for the passengers than the first-class seat. Application: The adopted methodologies could be used to measure the seating comfort of the train seats.

Influence of Changing Combustor Pressure on Combustion Characteristics and Local Reaction Intensity in the CH4/Air Flames (메탄/공기 화염에서 연소실 압력변동이 연소특성과 국소 반응강도에 미치는 영향)

  • Kim, Jong-Ryul;Choi, Gyung-Min;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.5
    • /
    • pp.365-372
    • /
    • 2009
  • The influence of combustor pressure on the local reaction characteristics of $CH_4$/air flames was investigated by measurements of local chemiluminescence intensity. Induced flow flames are often applied to the industrial boiler systems and incinerator in order to improve heat transfer and prevent exhaust gas leakage. In order to investigate combustion characteristics in the induced flow pattern, the combustor pressure index($P^*$) was controlled in the range of $0.7{\sim}1.3$ for each equivalence ratio in the present combustion system, where $P^*$ is defined as the ratio of absolute pressure to atmospheric one. Relationship between local reaction intensity and pressure index have been investigated by simultaneous $CH^*$, $C^*_2$ and $OH^*$ intensity measurements. It could be observed that flame length became longer with decreasing $P^*$ from $CH^*$ chemiluminescence intensity of axial direction. The mean value of $C^*_2$ and $CH^*$ chemiluminescence intensities, which indicates reaction intensity in the $CH_4$/air flames, decreased with decreasing pressure index for ${\Phi}{\leq}1$, but increased with decreasing pressure index for ${\Phi}$>1. $C^*_2/CH^*$ intensity ratio, which can be a good marker to demonstrate local equivalence ratio, was almost same for ${\Phi}{\leq}1$ regardless of pressure index change, while they showed high level for lower pressure index for ${\Phi}$>1 conditions.