• Title/Summary/Keyword: Pressure Meter Test

Search Result 116, Processing Time 0.024 seconds

Control of Shock Wave/Boundary-Layer Interactions Using S-Shaped Mesoflaps (S-자형 플랩을 이용한 충격파와 경계층 간섭현상 제어에 관한 연구)

  • Lee Yeol
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.159-160
    • /
    • 2002
  • New S-shaped aeroelastic mesoflaps are utilized to control normal shock/boundary-layer interactions. New generation of the mesoflaps is designed f3r a better rigidness and a good flow uniformity across the ulteractions. ,Major advantages of the mesoflap system can be a better total pressure recovery downstream of the interactions due to the lambda shock structure over the flap system, and a rehabilitation of the thickened boundary layer due to bleeding through a cavity underneath the flap system. Skin friction has been measured downstream of the interactions, using the laser interferometer skin friction (LISF) meter, which optically detects the rate of thinning of an oil film applied to the test surface. Various flap-thicknesses of the S-shaped mesoflap arrays are tested, and the results are compared to the solid-wall reference case. Overall, not much difference in the level of skin friction is noticed for the S-shaped flap arrays of various thicknesses, and its level is lower than the skin friction downstream of the solid-wall interaction

  • PDF

Enhancement of Oxygen Transfer Efficiency Using Vibrating lung Assist Device in In-Vitro Fluid Flow (In-vitro 유동장에서 진동형 폐 보조장치를 이용한 산소전달 효율의 향상)

  • 권대규;김기범;이삼철;정경락;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1332-1335
    • /
    • 2003
  • This paper presents the enhancement of oxygen transfer efficiency using the vibrating intravascular lung assist device (VIVLAD) in in-vitro experiments for patients having chronic respiratory problems. The test section was a cylinder duct with the inner diameter of 30 mm. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-vibrator, a function generator. and a power amplifier. The direction of vibration was radial to the fluid flow. Gas flow rates of up to 6 l/min through the 120-cm-Jong hollow fibers have been achieved by exciting a piezo-vibrator. The output of PVDF sensor were investigated by various frequencies in VIVLAD. The experimental results showed that VIVLAD would be enhance oxygen transfer efficiency.

  • PDF

An experimental study of the time based mass flow controller for semiconductor industry (반도체용 시간식 질량유량계의 특성에 관한 연구)

  • Chang, Young-Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.55-58
    • /
    • 2008
  • The objective of the research is to design, manufacture and test a Mass Flow Controller(MFC) capable of measuring compressible fluid flows based on a "bucket and stop-watch"method. The basic principle is the measurement of time, where the time taken to fill and empty a bucket of known volume is measured. This method of flow measurement is a new concept when compared to a commercilized current mass flow controller. For the flow meter to be able to compete with established designs it not only must be comparable in cost and robustness, it must be very accurate and reliable as well. This device should be able to handle fluid flows in the range of 0.1ml/min to 10ml/min within an accuracy of ${\pm}$1%. A possible application for a device such as this is in electronics industry where arsenic gas is used in the production of silicon chips.

  • PDF

An investigation into the effect of denture adhesives on incisal bite force of complete denture wearers using pressure transducers - a clinical study

  • Kalra, Pawan;Nadiger, Ramesh;Shah, Farhan Khalid
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.97-102
    • /
    • 2012
  • Study was conducted to determine and assess the effect of different type of denture adhesives on the incisal bite force of complete denture wearers until the dislodgement of upper denture, using pressure transducer. MATERIALS AND METHODS. 30 patients out of 100 were included in the study. Based on the Kapur's method of scoring denture retention and stability, these patients were divided into 3 groups-Group A - Clinically good dentures; Group B - Clinically fair dentures; and Group C - Clinically poor dentures. A custom made occlusal force meter was constructed based on the load cell type of pressure transducers. Different adhesives (powder, paste and adhesive strips) were used in the study. Complete denture wearers were asked to bite on the load cell and the readings of incisal bite force were recorded. The readings of incisal bite force were subjected to statistical analysis using Repeated measures ANOVA followed by post-hoc bonferroni test. RESULTS. The result suggests that denture adhesives improved the incisal bite force of complete denture wearers significantly The incisal bite force (in kg) in Group A without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 2.48 (${\pm}0.16$), 3.43 (${\pm}0.11$), 6.01 (${\pm}0.11$), 3.22 (${\pm}0.09$) respectively. The incisal bite force (in kg) in Group B without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.87 (${\pm}0.18$), 3.35 (${\pm}0.14$), 5.34 (${\pm}0.18$), 3.21 (${\pm}0.12$) respectively. The incisal bite force (in kg) in Group C without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.00 (${\pm}0.17$), 3.07 (${\pm}0.14$), 4.37 (${\pm}0.26$), 2.99 (${\pm}0.14$) respectively. CONCLUSION. Within the limitations of the study, it was concluded that the use of denture adhesive was found to be significantly effective in improving the incisal bite force of complete dentures until the dislodgement of upper denture. Fittydent paste adhesive was found to be more effective than the powder and strips adhesives. The improvement in incisal bite force was found to be higher in Group C in comparison to that of Group A and Group B.

The Effects of Respiratory Muscle Training on Respiratory Function, Respiratory Muscle Strength, and Cough Capacity in Stroke Patients (호흡근 강화 훈련이 뇌졸중 환자의 호흡기능, 호흡근력과 기침능력에 미치는 영향)

  • Jo, Myeong-Rae;Kim, Nan-Soo;Jung, Ju-Hyeon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.399-406
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the effects of respiratory muscle training on respiratory function, respiratory muscle strength, and cough capacity in stroke patients. METHODS: This study used a nonequivalent control group pre-post test design. We recruited thirty-four stroke patients(16male, 18female), who were assigned to intervention (n=17), or control (n=17) groups. Both groups participated in a conventional stroke rehabilitation program, with the intervention groups also receiving respiratory muscle training 20 minutes a day, three times a week, for 4 weeks. Respiratory function (forced vital capacity) and respiratory muscle strength (maximal inspiratory pressure, maximal expiratory pressure) were assessed by spirometry. Cough capacity (peak expiratory flow) was assessed using a peak flow meter. The collected data were analyzed by independent and paired t-tests. RESULTS: The intervention group showed a significant increase in the forced vital capacity (FVC), maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP) and peak expiratory flow (PEF) at the end of the program, while the control group showed no significant changes. CONCLUSION: This study showed that respiratory muscle training increased respiratory function, respiratory muscle strength, and cough capacity in stroke patients and prevented a decrease in cough capacity. These findings suggest that respiratory muscle training effect on respiratory function, respiratory muscle strength and cough capacity for rehabilitation in patients with stroke.

The Use of Skin Resistance Point Finder for the Diagnosis of Myofascial Trigger Points (피부 저항점 탐지기를 사용한 근근막 통증 유발점의 진단)

  • Kang, Mi-Suk;Hong, Jung-Eun;Lim, Young-Jin;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.12 no.2
    • /
    • pp.195-199
    • /
    • 1999
  • Background: At present, there is no reliable objective test for the diagnosis of myofascial trigger points (MFTP). We evaluated the usefulness of skin resistance point finder for the diagnosis of MFTP. Methods: 40 subjects with clinical MFTPs at the upper trapezius muscle were included in this study. Using skin resistance point finder (UNIQUE S-2010$^{(R)}$, Seik medical, Korea), we tried to find out the point of low skin resistance. At three different current level, sensitivity and specificity of this method for the diagnosis of clinically identified MFTP was evaluated. Pressure threshold for pain of low skin resistance point was measured using Pressure Threshold Meter$^{(R)}$ (Pain Diagnostics and Thermography, U.S.A.). 3 groups of point detected at different current were compared in mean pressure threshold. Results: Fixed single current of skin resistance point finder showed variable sensitivity and specificity. But, by adjusting current level, skin resistance point finder detected all of 40 clinically identified MFTPs. Although it is partially statistically significant, the mean pressure threshold of points detected at high current was high. Conclusion: Skin resistance finder can be used as objective diagnostic tool of MFTPs. There is possibility that it can be useful in evaluating treatment effect. However, more investigation is necessary.

  • PDF

Study on $CO_2$ Evaporation Heat Transfer and Pressure Drop in a Horizontal Smooth Tube (수평 평활관내 $CO_2$ 증발열전달 및 압력강하에 관한 연구)

  • Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.615-621
    • /
    • 2007
  • Experimental study on the heat transfer characteristics of $CO_2$ in a horizontal smooth tube was carried out to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$. The experiment apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200kg/m^2s$), heat flukes ($10{\sim}100kW/m^2$) and saturation temperatures (-5, 0, $5^{\circ}C$). With increasing the heat flux, the evaporation heat transfer coefficient increased. But the variation of the heat transfer coefficient on the increase of the mass flux was not large. And the significantly drops of the heat transfer coefficient was observed at any heat flux and mass flux because of the change of the flow pattern in the tube. With increasing the saturation temperature, the heat transfer coefficient increased due to the promotion of a nucleate boiling. The measured pressure drop during evaporation increased with increasing the mass flux and decreasing the saturation temperature.

A Case Study on the Ground Reinforcement Method and Effect of the Failed Tunnel (터널붕괴지반의 보강공법 및 효과에 대한 사례연구)

  • Cho, Hyun;Lim, Jae-Seung;Chung, Yoon-Young;Choi, Sang-Yeul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.293-300
    • /
    • 1999
  • The maintenance for the stability of tunnel, especially on downtown area, careful check must be considered during construction stage and after. Moreover we have to achieve the stability of tunnel by ground improvement and reinforcement when ground condition is bad or tunnel failures under the various ground conditions. In this paper, it is presented the case of tunnel failure and the state of restoration by ground reinforcements at seoul subway $\bigcirc$-$\bigcirc$ construction site. For the purpose of ground reinforcement, first, curtain wall was established by chemical grouting. Secondly, cement milk grouting was carried by upper part of tunnel crown. Also Boreholes loading test and tunnel monitoring were carried by in failure site for the long term stability of tunnel.

  • PDF

Cooling Heat Transfer Characteristics of CO2 in a Brazing Type Small Diameter Copper Tube (브레이징식 동세관내 CO2의 냉각 열전달 특성)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.827-834
    • /
    • 2009
  • The cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a $CO_2$ compressor, a mass flow meter, an evaporator and a brazing type small diameter tube as a test section. The mass flux of $CO_2$ is $400{\sim}1600$ [kg/$m^2s$], the mass flowrate of coolant were varied from 0.15 to 0.3 [kg/s], and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The cooling heat transfer coefficients of the brazing type small diameter copper tube is about $4{\sim}11.7%$ higher than that of the conventional type small diameter copper tube. In comparison with test results and existing correlations, correlations failed to predict the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube. therefore, it is necessary to develope reliable and accurate predictions determining the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube.

A Study on the Low Cost Testing System Development of the Low Speed and High Torque Harsh Reducer (저속 고토크 가혹감속기의 저비용 테스트 시스템 개발에 관한 연구)

  • Park, Taehyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.379-386
    • /
    • 2022
  • The goal of this research is to verify a performance test system for a low speed, high torque, and harsh reducer at low cost. The reducer rotates a cooling fan with a diameter of 10 meters, in a high temperature (50℃) cooling tower in a geothermal power plant. It requires about 500 kgf·m torque and 47.75 kW power to rotate the fan at a maximum power condition. An expensive dynamometer is commonly used for performance test of a motor or a reducer. In this paper, a low cost system is developed using a hydraulic pump as a load unit to generate torque instead of a dynamometer. We accurately calculated the required power, the flow meter, and the pressure of the pump, and selected to design and optimize the system at minimal cost. The system also applied another reverse reducer and a gearbox to increase the rotational speed and to reduce the torque from the low speed and high torque target reducer. This allows low-cost systems to be built using inexpensive components. The developed system was able to successfully measure the high torque and the low rotational speed of the target reducer at high temperature.