• Title/Summary/Keyword: Pressure Control Device

Search Result 364, Processing Time 0.023 seconds

A Balance Training System using a Haptic Device and Its Evaluations (햅틱 장치를 이용한 균형 훈련 시스템 및 효용성 검증)

  • Yoon, JungWon;Afzal, Muhammad Raheel;Pyo, SangHun;Oh, Min-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.9
    • /
    • pp.971-976
    • /
    • 2014
  • Haptic device can be a useful rehabilitation tool in balance training. The proposed system is composed of a body-wear smartphone, Phantom Omni(R) device, and its control PC system. Ten young healthy subjects performed balance tasks with different postures during 30 seconds with their eyes closed. An Android program on the smartphone transferred mediolateral (ML) and anteroposterior (AP) tilt angles to the PC system, which can generate haptic command through haptic device. Statistical data analysis was performed using MATLAB(R). COP (Center of Pressure) related indexes were measured to see reduction in body sway. ANOVA showed that haptic device significantly reduced body sway. Intuitive balance guidance could be generated using an economical and small-sized commercial haptic device, making the system efficient.

Effectiveness Evaluation of Displacement Accommodatable Pressure Measuring Jig for Quality Assessment of Pressure Application Device (압력 인가 장치의 품질관리를 위한 변위 수용이 가능한 압력 측정용 지그의 유효성 평가)

  • Mun, Chang-Su;Jun, Sung-Chul;Noh, Si-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • Recently, a variety of electric anesthetics devices have been developed and used in clinical practice to reduce the fatigue of the operator during local anesthesia for dental procedures and to compensate for the disadvantages of manual anesthesia device. In this electric anesthesia injection device, the accurate and constant delivery of pressure for drug infusion is a very important performance factor. In order to evaluate the accuracy of the transfer pressure, a small pressure gauge using a load cell is often used, but since the elastic body inside the load cell may not be able to accommodate a sufficient displacement, an error may occur when evaluating pressure performance. For these reasons, in this study, we proposed and evaluated a silicon-chrome steel (Si-Cr steel) spring jig that can accommodate relatively large displacements that can be used when evaluating the performance of a pressure-controlled pressure application device using a load cell type pressure gauge. As a result of the pressure transmissibility test and repeated measurement results using a commercial dental anesthesia injection device, a more stable result was obtained when using a spring jig, and it was confirmed that the frequency of abnormally high measurement was reduced.

A Study on Development of Hydraulic Pressure System Using Cartridge Valve (Cartridge Valve를 이용한 유압시스템 개발에 관한 연구)

  • Lee, Woo;Jung, Seok-Yoon;Kim, Sang-Gu;Kim, Kyung-Hoon;Byun, Seung-Nam
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1279-1282
    • /
    • 2003
  • The hydraulic pressure system can deliver strong power and control is easy so that it have been applied to the element technique of an each industrial field. Apply range is the actual circumstances to be more widening according to the automation plant and trend of the manufacture facilities. The hydraulic pressure system have been used since early times and it was universalized considerable in the industrialized country. Utilized to an automation device instrument wide at an each industrial spot and contributed the air space development which contribution make great strides for robotics and airospace departments. Our circuit design technology for the device structure are weak and in fact domestic is depending on the income though importance of the hydraulic pressure system.

  • PDF

Design, Fabrication, and Application of a Microfluidic Device for Investigating Physical Stress-Induced Behavior in Yeast and Microalgae

  • Oh, Soojung;Kim, Jangho;Ryu, Hyun Ryul;Lim, Ki-Taek;Chung, Jong Hoon;Jeon, Noo Li
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.244-252
    • /
    • 2014
  • Purpose: The development of an efficient in vitro cell culture device to process various cells would represent a major milestone in biological science and engineering. However, the current conventional macro-scale in vitro cell culture platforms are limited in their capacity for detailed analysis and determination of cellular behavior in complex environments. This paper describes a microfluidic-based culture device that allows accurate control of parameters of physical cues such as pressure. Methods: A microfluidic device, as a model microbioreactor, was designed and fabricated to culture Saccharomyces cerevisiae and Chlamydomonas reinhardtii under various conditions of physical pressure stimulus. This device was compatible with live-cell imaging and allowed quantitative analysis of physical cue-induced behavior in yeast and microalgae. Results: A simple microfluidic-based in vitro cell culture device containing a cell culture channel and an air channel was developed to investigate physical pressure stress-induced behavior in yeasts and microalgae. The shapes of Saccharomyces cerevisiae and Chlamydomonas reinhardtii could be controlled under compressive stress. The lipid production by Chlamydomonas reinhardtii was significantly enhanced by compressive stress in the microfluidic device when compared to cells cultured without compressive stress. Conclusions: This microfluidic-based in vitro cell culture device can be used as a tool for quantitative analysis of cellular behavior under complex physical and chemical conditions.

An Experimental Study on Cushion Characteristics of pneumatic Cylinder for Vertically-Mounted. (공압 수직실린더의 쿠션특성에 관한 실험적 연구)

  • Kim, Dong-Su;Kim, Hyeong-Ui;Lee, Sang-Cheon
    • 연구논문집
    • /
    • s.28
    • /
    • pp.73-87
    • /
    • 1998
  • A pneumatic control system of compressed air as a working fluid has a variety of advantages such as low price, high respondence, non-explosion and good control performance and thus has many applications in the field of automobile, electronic and semiconductor industry. However, it has a difficulty in contolling a precise position due to quick response of system and compressibility of working fluid and. in particular, shock stress may occur due to an external load, resulting in fracture of a cylinder cap unless cushion device is equipped in the linear actuator. To avoid this, a cushion device should be installed for damping effect of the external load and the supply pressure as well as for decreasing shock stress and vibration caused by high speed rotation. Previous studies include dimensionless analyses and computer simulations of cushion capability and experiments of horizontally-mounted cylinder performances. A new attempt is experimentally made in this study using a vertically-mounted cylinder under an operation condition of 4, 5 and 6 (bar) as supply pressure and 40, 70 and 100 (kgf) as external load. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion characteristics was also revealed in the meter-in circuit.

  • PDF

Energetics of the Heart Model with the Ventricu1ar Assist Device

  • Chung, Chanil-Chung;Lee, Sang-Woo;Han, Dong-Chul;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 1996
  • We investigated the energistics of the physiological heart model by comparing predictive indexes of the myocardial oxygen consumption (MOC), such as tension-time index (R), tension-time or force-time inteual (FTI), rate-pressure product (RPP), pressure-work index, and systolic pressure-volume area (PVA) when using the electro-hydraulic left ventricular device (LVAD). We developed the model of LVAD incorporated the closed-loop cardiovascular system with a baroreceptor which can control heart rate and time-varying elastance of left and right ventricles. On considering the benefit of the LVAD, the effects of various operation modes, especially timing of assistance, were evaluated using this coupled computer model. Overall results of the computer simulation shows that our LVAD can unload the ischemic (less contractile) heart by decreasing the MU and increasing coronary flow. Because the pump ejection at the end diastolic phase of the natural heart may increase the afterload of the left ventricle, the control scheme of our LVAD must prohibit ejecting at this time. Since the increment of coronary flow is proportional to the peak aortic pressure after ventricle contraction, the LVAD must eject immediately following the closure of the aortic valve to increase oxygen availability.

  • PDF

A study on the I-V Properties of Long Chain Fatty Acid of LB Thin Films (장쇄지방산 LB박막의 전류-전압 특성에 관한 연구)

  • Chon, Dong-Kyu;Chang, Hun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.913-919
    • /
    • 2000
  • We give pressure stimulation into long chain fatty acid of LB thin films then manufacture a device under the accumulation condition that the state surface pressure is 20[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Arachidic acid/Al, the number of accumulated layers are 13, 17 and 19. The I-V characteristic of the device is measured from 0[V] to +1.5[V]. We have investigated the capacitance because this fatty acid system have a accumulated layers. The maximum value of measured current is increased as the number of accumulated layers are decreased. The capacitor properties of a thin film is better as the distance between electrodes is smaller. The results have shown the insulating materials and could control the conductivity by accumulated layers.

  • PDF

Development of Technology for Printing Pressure Control of Blanket Cylinder (블랭킷 실린더의 인압제어 기술개발)

  • Ham, Yeong-Bok;Yun, So-Nam;Kim, Gwang-Yeong;Choe, Byeong-O
    • 연구논문집
    • /
    • s.32
    • /
    • pp.15-22
    • /
    • 2002
  • In offset or intaglio printing machine, it's operated with combination of blanket cylinder and impression cylinder. The blanket cylinder has some number of grooves to attach the blanket on surface. In case of operating the printing machine, it has generate mechanical impact noise when the two cylinders encounter with the grooves. So, in this study, we developed a printing pressure control algorithm with hydraulic servo control system. We also proposed simulation model of experimental device to analysis the throw on force response of hydraulic servo actuator. Finally, we have reduced the mechanical impact noise and improved printing quality with a groove detecting signal and PI control of hydraulic servo actuator.

  • PDF

A Study on the Meter-Out and Meter-In Speed Control Characteristics in Pneumatic Cushion Cylinders (공기압 쿠션 실린더의 미터아웃/미터인 속도제어 특성에 관한 연구)

  • Kim, Do-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Pneumatic cylinders are widely used to actuators in automatic equipments because they are relatively inexpensive, simple to install and maintain, offer robust design and operation, are available in a wide range of standard sizes and design alternatives. This paper presents a comparative study among the dynamic characteristics of meter-out and meter-in speed control of pneumatic cushion cylinders with a relief valve type cushion mechanism. Because of the nonlinear differential equations and a requirement for simultaneous iterative solution in a mathematical model of a double acting pneumatic cushion cylinder, a computer simulation is carried out to investigate pressure, temperature, mass flow rate in cushion chamber and displacement and velocity time histories of piston under various operating conditions. It is found that the piston velocity and pressure response in meter-in speed control are more oscillatory than with meter-out those when pneumatic cushion cylinders are driven at a high-speed. In meter-out speed control, the effective area of the flow control valve is larger than that of meter-in, and the supply pressure has to be much higher than the pressure required to move the load because it has also to overcome the back pressure in cushion chamber.

A study on the flow charateristics of temperature control valve by pressure compensation (압력 평형식 온도 조절 밸브의 유동특성 연구)

  • Kim, T.-A.;Kim, Youn J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.419-424
    • /
    • 2001
  • TCV(Temperature control valve by pressure compensation) controls temperature constantly, when it is sending steam or high temperature water to heating device of heat exchanger. For designing TCV, the ratio of piston and hole diameters is one of the important design parameters. Numerical analysis is carried out to elucidate the flow characteristics in the TCV with different port areas of cold and hot waters, using the k-$\epsilon$ turbulence model and Cartesian cut-cell method. Numerical results show that the exit flow rate is mainly affected by pressure distribution in the piston.

  • PDF