Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Daily localization of partial breast irradiation patients with three-dimensional ultrasound imaging

  • Sayan, Mutlay;Vergalasova, Irina;Hard, Daphne;Wrigth, Heather;Archambault, Jessica;Gagne, Havaleh;Nelson, Carl;Heimann, Ruth
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.259-264
    • /
    • 2019
  • Purpose: Accurate localization of the lumpectomy cavity during accelerated partial breast radiation (APBR) is essential for daily setup to ensure the prescribed dose encompasses the target and avoids unnecessary irradiation to surrounding normal tissues. Three-dimensional ultrasound (3D-US) allows direct visualization of the lumpectomy cavity without additional radiation exposure. The purpose of this study was to evaluate the feasibility of 3D-US in daily target localization for APBR. Materials and methods: Forty-seven patients with stage I breast cancer who underwent breast conserving surgery were treated with a 2-week course of APBR. Patients with visible lumpectomy cavities on high quality 3D-US images were included in this analysis. Prior to each treatment, X-ray and 3D-US images were acquired and compared to images from simulation to confirm accurate position and determine shifts. Volume change of the lumpectomy cavity was determined daily with 3D-US. Results: A total of 118 images of each modality from 12 eligible patients were analyzed. The average change in cavity volume was 7.8% (range, -24.1% to 14.4%) on 3D-US from simulation to the end-of-treatment. Based on 3D-US, significantly larger shifts were necessary compared to portal films in all three dimensions: anterior/posterior (p = 7E-11), left/right (p = 0.002), and superior/inferior (p = 0.004). Conclusion: Given that the lumpectomy cavity is not directly visible via X-ray images, accurate positioning may not be fully achieved by X-ray images. Therefore, when the lumpectomy cavity is visible on US, 3D-US can be considered as an alternative to X-ray imaging during daily positioning for selected patients treated with APBR, thus avoiding additional exposure to ionizing radiation.

Main Trends for Reforming the Duty of Utmost Good Faith in English Insurance Contracts Law - Focused on the Policyholder's Pre-Contractual Duty in Insurance Contracts for Business (영국 보험계약법 상 최대선의의무에 관한 주요 개혁동향)

  • Shin, Gun-Hoon
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.49
    • /
    • pp.257-281
    • /
    • 2011
  • The duty of utmost good faith is found in sections 17-20 of MIA 1906. Critics of the current legal regime on the pre-contractual duty from the viewpoint of the assured, have been concentrated on two points in particular. First, the scope of the duty is so wide that it imposes too high burden on the assured. The second criticism is directed at the remedy, prescribed by the MIA 1906, s.17, against breach of the duty. This article intends to analyse the legal implications of proposals in CP 2007 for reforming pre-contractual duty of utmost good faith of business assured in English insurance contracts law and the problems of proposals. The Law Commissions are proposing four fundamental changes to meet the long-standing criticism and the results of analysis are as following. First, the Law Commissions are proposing a change in the test of constructive knowledge in relation to the duty of disclosure so that a business assured will be obliged to disclose facts which he knows or a reasonable ought to know in the circumstances. Secondly, deviating from the current legal position, the Law Commissions are proposing that if a business assured has made a misrepresentation, but the assured honestly and reasonably believe what it said to be true, the insurer should not have any remedy due to the misrepresentation. The proposal is designed to protect the reasonable expectations of business assured at the pre-contractual stage. Thirdly, the Law Commissions are proposing to change the test for materiality by replacing the "prudent insurer" test by a "reasonable assured" test. The proposed test would focus on the question of what a reasonable assured in the circumstances would think what is relevant to the judgment of the insurer. Finally, the Law Commissions are proposing flexible remedies in case of the breach of the duty. The Law Commissions are proposing no remedy when an assured is acting honestly and reasonably, while avoidance in case of dishonesty. On the other hand, The Law Commissions seem to have an intention to introduce a compensatory remedy in case of negligent breach of the duty.

  • PDF

Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy (고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, Juhn-Kyu
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.243-252
    • /
    • 1994
  • The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation, An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intraluminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

  • PDF

EARLY DETECTION OF BEHCET'S DISEASE (베체트병의 조기 진단)

  • Kim, Seung-Hye;Song, Je-Seon;Choi, Hyung-Jun;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.4
    • /
    • pp.575-579
    • /
    • 2009
  • Behcet's disease(BD) is a multisystem vasculitis that almost any organ in the body may be involved. Its diagnosis bases on clinical criteria in the absence of any specific laboratory test to confirm it. The clinical criteria proposed for the diagnosis for BD include recurrent oral and genital ulceration, skin lesion, ocular changes, and positive response to pathergy test. Besides these essential features, BD may manifest itself on the gastrointestinal tract, central nervous system, and other systemic involvements. Among these clinical features, recurrent oral ulcers are present in most BD patients, often as the initial symptom, preceding other manifestations by many years. Therefore, dentists are in the important position for the early detection and diagnosis of BD. In this case report, we are presenting a case of 6 year-old girl, who came to the pediatric dentistry department for evaluation and treatment of pain and dysphagia caused by severe recurrent oral ulcers. Through taking detailed dental and medical history and clinical examination, we reported the possibility of BD to the medical team and prescribed topical lidocaine to relief pain during swallowing. The medical team, which involved pediatrics, ophthalmology, dermatology, and gastroenterology, finally confirmed BD through various examinations. Detection of the possibility of BD in the dental field helped early diagnosis and proper management by the medical team.

  • PDF

The Study on Usefulness of the Standardized Information of Nuclear Medicine Scan in Function Evaluation of the Salivary Glands (침샘의 기능평가에서 핵의학 검사의 표준화된 정보제공의 유용성 연구)

  • Pyo, Sungjai;Han, Jaebok;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.357-362
    • /
    • 2015
  • This study was to evaluate the usefulness through the comparison of patients group and healthy control group by acquiring a variety of functional parameters index from time-activity curves of salivary gland scan using 99mTc-pertechnetate. From December 2014 to February 2015, had the targets of 30 patients with dry mouth and 10 people in healthy control group underwent the salivary gland scan. After intravenous injection of 370 MBq of 99mTc-pertechnetate, Vitamin C powder stimulation was administerd orally at 20 min and then 10 minutes were taken scan. The method of quantitative analysis was as follows, the time-activity curve was drawn after the parotid gland and submandible gland were prescribed as a region of interest, a variety of function parameters index was obtained in each position of the curve, and the patients group and the control group were compared. As for the methods applied in comparison and measurement, uptake ratio (UR), time at maximum counts (Tmax), time at minimum counts (Tmin), maximum accumulation (MA), accumulation velocity, maximum secretion (MS), maximum stimulation secretion (MSS), and secretion velocity (SV) were used. In the comparison of functional parameters index of patient group and normal group, the healthy normal group showed significant difference compared to the patient group in all indices except for the minimum radioactivity time (Tmin), and also in terms of variation over time the normal group showed significant difference compared to the patient group (p<0.05). Consequently, it was considered that the quantitative analysis that used a variety of function parameters index would be useful for evaluating the function of the salivary glands of the patients with dry mouth as an objective and standardized information.

Study on the Radiation Pattern of Radiated Emission above 1 GHz (1 GHz 이상에서의 복사 방출 방사 패턴에 관한 연구)

  • Chung, Yeon-Choon;Lee, Soon-Yong;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.336-344
    • /
    • 2011
  • The purpose of this study is to analyze the radiation-pattern characteristics above 1 GHz for the electromagnetic wave radiated from multi-slot such as ventilations, etc. on the enclosure of an EUT and so to make recommendations for suitable test methods. An experimental EUT was formed by putting a comb-generator at the center of a rectangular enclosure with 4 slots, and its radiation pattern was analyzed in the frequency range of 1~6 GHz. As analysis results, multi-lobe appears above 2 GHz and the number of multi-lobes is growing as the frequency increases. And real radiated-emission measurements were performed for the experimental EUT by scanning a receiving antenna in the height of 1~4 m and tilting toward maximum radiation, as well as setting the height of a receiving antenna to the central position of the EUT which is prescribed at the present standards. The measured results are +12.8 dB in the scanning and +16.4 in the scanning and tilting compared with the present standard test method. Therefore, the latter must be revised in order to consider the radiation pattern above 1 GHz.

THE STUDY ON MODERN DESIGN REFLECTED NATIONAL DISPOSITION AND CULTURAL CHARACTER - Focused on the re-definition of Korean national disposition and cultural character for design Education - (민족적(民族的) 기질(氣質)과 문화적 성격이 반영되는 현대 디자인에 대한 고찰 - 디자인 교육을 위한 한국의 민족, 문화적 기질의 정의를 중심으로 -)

  • Choi, Sung-Woon;Cho, Eun-Hwan
    • Archives of design research
    • /
    • v.19 no.2 s.64
    • /
    • pp.129-138
    • /
    • 2006
  • Design securing a dominant position currently in the global market has shown inherent culture of each country, i.d. national disposition. For instancess, there are Scandinavia emphasizing humanism, America adopting pragmatism, Germany reflecting the rational principle, Spain reflecting the daily an, Italian design being rationalism and impressionism. The members of society shall be under the control of the already formed social-cultural value and character. So culture shall restrict the internal manner of social behaviour and apply pressure to the action of main body. Also culture shall be under the control of social environment and each culture shall be materialized as per the disposition of the members of society. Now korean design has been attracted lots of interests and attention from global market because it is excellent in the aspect of application capability for new technology and also suggests the image of design produced through them. Now Korean design shall run side by side the application for formative element to be recognized by technical design as well as korean identity. So dear definition for national and cultural disposition shall be required to korean design education and design development. These prescribed efforts shall be a shortcut for globalization of korean design.

  • PDF

Proposal of Modified Velpeau View as an Alternative Test Method of Velpeau View and the Visual Comparison (Velpeau view의 대체 검사법으로서 modified velpeau view의 제안 및 영상 비교평가)

  • Lee, Jae-Hyun;Kim, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.323-328
    • /
    • 2010
  • If a patient wearing arm sliding due to shoulder dislocation or fracture is impossible with abduction, the velpeau view is performed instead of superior-inferior axial projection view. However, it aggravates the patient's pain because it is difficult for the patient with dislocation or fracture to pull back the shoulders. Therefore, I suggest a new method of the 'modified velpeau view' that allows patients to lower their heads at examination. In order to investigate the easiness of fixing posture at examination and clinical utility, I conducted a study comparing the bone structures at the velpeau view and those at the modified velpeau view depending on wall-bucky and the patients' leaning forward angle ($30^{\circ},\;45^{\circ},\;60^{\circ}\;and\;75^{\circ}$), with the subjects of 20 velpeau view-prescribed patients amongst who had come to my hospital suspected of dislocation of shoulder or fracture and 30 healthy people from October of 2009 to January of 2010. Department of radiologists and orthopedics specialists evaluated the pictures for scales 0 to 5(best grade) under the given criteria. As a result of comparison in bone structures depending on wall-bucky and the leaning-forward angle in the group of healthy people, the velpeau view and the modified velpeau showed a similar diagnostic utility at $45^{\circ}$ and $60^{\circ}$. The picture evaluation result for proving diagnostic value showed that the anterior and posterior of shoulder heads and the anterior and posterior of glenoid fossa could be observed in the velpeau view; on the other hand, besides these areas acromioclavicular joint and coracoid process could be viewed in the modified velpeau view. This result verified that the modified velpeau view could replace the velpeau view for its diagnostic value as an examination method. This result, moreover, suggests that the modified velpeau view needs to be studied and improved from a variety of perspectives not only for an alternative for patients having troubles with the velpeau view position but also for clinical application of new test method for diagnosis of shoulder disorders other than dislocation of shoulder or fracture.

Sea Fog Level Estimation based on Maritime Digital Image for Protection of Aids to Navigation (항로표지 보호를 위한 디지털 영상기반 해무 강도 측정 알고리즘)

  • Ryu, Eun-Ji;Lee, Hyo-Chan;Cho, Sung-Yoon;Kwon, Ki-Won;Im, Tae-Ho
    • Journal of Internet Computing and Services
    • /
    • v.22 no.6
    • /
    • pp.25-32
    • /
    • 2021
  • In line with future changes in the marine environment, Aids to Navigation has been used in various fields and their use is increasing. The term "Aids to Navigation" means an aid to navigation prescribed by Ordinance of the Ministry of Oceans and Fisheries which shows navigating ships the position and direction of the ships, position of obstacles, etc. through lights, shapes, colors, sound, radio waves, etc. Also now the use of Aids to Navigation is transforming into a means of identifying and recording the marine weather environment by mounting various sensors and cameras. However, Aids to Navigation are mainly lost due to collisions with ships, and in particular, safety accidents occur because of poor observation visibility due to sea fog. The inflow of sea fog poses risks to ports and sea transportation, and it is not easy to predict sea fog because of the large difference in the possibility of occurrence depending on time and region. In addition, it is difficult to manage individually due to the features of Aids to Navigation distributed throughout the sea. To solve this problem, this paper aims to identify the marine weather environment by estimating sea fog level approximately with images taken by cameras mounted on Aids to Navigation and to resolve safety accidents caused by weather. Instead of optical and temperature sensors that are difficult to install and expensive to measure sea fog level, sea fog level is measured through the use of general images of cameras mounted on Aids to Navigation. Furthermore, as a prior study for real-time sea fog level estimation in various seas, the sea fog level criteria are presented using the Haze Model and Dark Channel Prior. A specific threshold value is set in the image through Dark Channel Prior(DCP), and based on this, the number of pixels without sea fog is found in the entire image to estimate the sea fog level. Experimental results demonstrate the possibility of estimating the sea fog level using synthetic haze image dataset and real haze image dataset.