본 논문에서는 움직이는 타깃을 대상으로 처방선량과 치료기법에 따른 흡수선량을 유리선량계를 이용하여 평가하였다. 타깃의 움직임에 따라 조사야에서 벗어나는 정도에 따른 선량을 MCNPX를 이용하여 모의모사하였으며 그 결과 조사야에서 이격하는 거리에 비례하여 감소하는 것으로 나타났다. 처방선량에 따른 흡수선량의 결과는 3D CRT의 경우 저선량에서 IMRT보다 흡수선량이 높은 것으로 나타났으며, 대선량에서는 IMRT가 더 높은 비율을 보였다. 치료기법에 따른 결과는 3D CRT가 가장 우수한 것으로 나타났으며, IMRT의 sliding window방식이 가장 낮은 것으로 나타났다. 본 연구를 통하여 3D CRT가 움직이는 타깃에 가장 높은 선량을 조사할 수 있는 기법으로 평가되었다. 하지만 정상조직의 보호효과와 환자의 상태 등을 고려한 적절한 치료기법의 선택으로 치료효과를 높일 수 있는 노력이 필요할 것이다.
Prescription filling in powder form is performed in community pharmacy practice to adjust dose for children and patients who cannot swallow whole tablet. However, there are few reports regarding the stability of the active ingredient and possible microbial growth after the medication is dispensed to powder form. This study examined the stability of atenolol, an antihypertensive agent, and microbial growth in the unit dose pouches dispensed at twenty-one community pharmacies located in Taegu area. Randomly chosen first unit dose pouch contained 77.4% of the prescribed dose of the drug and there were only four community pharmacies that dispensed the drug within 10% deviation from the dose prescribed by physician. Surprisingly, there were three community pharmacies that dispensed the drug with greater than 40% deviation, which may pose a major concern regarding the efficacy and safety of the drug prescribed for the treatment of hypertension. Atenolol content during a month did not indicate significant change, showing 5.4%, 4.3%, and 3.3% of decrease in 50%, 80%, and 90% relative humidity conditions, respectively. Microbiological examination during a month showed less than 0.5 microorganism in high power field (hpf) in all the relative humidity conditions tested. Based on this study, pharmacy practice in community pharmacy needs to be rigorously regulated to ensure that the dose of the prescribed drug is properly incorporated into the unit dose pouch dispensed as powder form.
Radiation protection in the scrotum to reduce the risk of genetic effect in the future is very important. This study aimed to measure the scrotal dose outside the treatment fields by using the radio-photoluminescence glass dosimeter (RPLGD). The characteristics of RPLGD model GD-302M were studied. Scattered dose to scrotum was measured in one liposarcoma case with the prescribed dose of 60 Gy. RPLGDs were placed in three different locations: one RPLGD was positioned at the posterior area which closer to the scrotum, and the other two RPLGDs were placed between the penis and the scrotum. Three RPLGDs were employed in each location. The scattered doses were measured in every fraction during the whole course of treatment. The entire number of 100 RPLGDs showed the uniformity within ±2%. The signal from RPLGD demonstrated linear proportion to the radiation dose (r = 0.999). The relative energy response correction factor was 1.05. The average scrotal dose was 4.1 ± 0.9 cGy per fraction. The results presented a wide range since there was a high uncertainty during RPLGD placement. The total scrotal dose for the whole course of treatment was 101.9 cGy (1.7% of the prescribed dose). The RPLGD model GD-302M could be used to measure scattered dose after applying the relative energy correction factor.
목 적: 본 연구에서는 자궁강 내 근접치료 시 ABS (American Brachytherapy Society)에서 권고한 H점(point H)을 이용한 치료계획을 수립해 보았고, 이를 A점(point A)에 처방한 치료계획과 비교하고자 한다. 대상 및 방법: 2010년 3월부터 2012년 1월까지 본원에 내원한 자궁경부암 환자 중 탄뎀(tandem)과 난형체(ovoid)를 이용해 고선량률 강내 근접치료(high dose rate intracavitary brachytherapy)를 시행한 103명을 대상으로 하였다. 치료계획은 Manchester System에 따라 A점, 방광 기준점, 직장 기준점을 지정하였고, ABS의 권고에 따라 H점을 지정하였다. 또한 임의로 S자 결장기준점과 질 기준점을 설정하였다. A점과 H점의 위치가 얼마나 차이가 나는지 살펴보았으며, H점에 100%의 선량을 처방하였을 때 A점에 들어가는 선량을 계산하였다. 그리고 A점과 H점에 각각 선량을 처방하였을 때 직장, 방광, S자 결장, 질 기준점에 들어가는 선량을 비교 분석하였다. 결 과: H점이 A점보다 미측에 있는 경우 A점의 상대선량은 기존의 A점이 아닌 H점에 처방하였을 때 더 적어지는 경향을 보였다. 방광 기준점과 직장 기준점, S자결장 기준점, 질 기준점에서의 상대선량은 H점이 두측에 있는 경우 H점에 처방하였을때의 선량이 A점에 처방하였을 때보다 크며, 미측에 있는 경우 더 적어지는 양상을 보였다. 결 론: H점이 A점보다 두측에 위치할수록 주변 장기의 흡수선량이 커지고, 미측에 위치할수록 주변 장기의 흡수선량이 적어지는 경향을 보였다. 그 선량 차이가 치료에 큰 영향을 미칠 정도는 아니지만, 두 치료계획에서의 선량 분포 및 주변 장기 흡수선량 차이가 크다면 두 점의 치료계획은 비교 또는 참고할 만한 가치가 있는 것으로 생각된다.
목 적: 피부와 같이 표면이 넓고 굴곡이 있는 부분을 치료할 때 토모테라피의 유용성과 치료 계획에서 계산된 표면 조사량의 정확성을 알아보고자 하였다. 대상 및 방법: 실린더 모양의 치즈 팬텀을 이용하여 2가지의 치료 계획을 세웠다. 첫 번째 계획은 표면에서 1 cm 깊이까지 고리 모양의 치료 부위를 설정하고, 여기에 2 Gy의 선량을 처방하였다. 다른 계획은 표면에서 5 mm 바깥쪽부터 1 cm 깊이까지 고리 모양의 치료 부위를 설정하고, 여기에 2 Gy의 선량을 처방하였다. 표면에서 2 cm 밑의 안쪽 부분은 차폐하여 방사선이 직접 들어가지 않도록 하였다. 표면 선량과 깊이에 따른 선량 분포를 측정하기 위하여, EDR2 필름을 팬텀 안에 넣었으며, TLD 칩 6개를 표면에 부착하였다. 결 과: 필름을 분석한 결과, 표면 선량은 첫 번째 계획에서 118.7 cGy였고 두 번째 계획에서 130.9 cGy였다. TLD 칩을 분석한 결과, 필름에 비하여 표면 선량이 높게 나왔는데 이것은 TLD 칩의 두께로 인한 것으로 생각된다. 처방 선량의 95%에 다다르는 깊이는 첫 번째 계획의 경우 2.1 mm, 두 번째 계획의 경우 2.2 mm였다. 최대 선량은 처방 선량의 110%였다. 표면에서 깊어질수록, 선량은 빠르게 감소하였고, 표면에서 2 cm 깊이에서는 처방 선량의 20%만 측정되었다. 결 론: 토모테라피는 피부와 같은 넓고 굴곡진 부위를 치료하는데 유용하다. 하지만 표면에서 2 mm 깊이 이내의 경우 실제 선량이 계획된 선량보다 적게 나타나기 때문에, 이 깊이보다 얕게 위치한 부위를 치료할 경우에는 보상체가 필요하다.
목 적 : Lung SABR plan 에서 AAA의 calculation grid를 변화시켜 선량변화를 분석하고 그에 따른 영향을 연구하여 적절한 적용 방안에 대해 고찰한다. 대상 및 방법 : 모든 plan에 이용된 4D CT image는 Brilliance Big Bore CT(Philips, Netherlands)에서 촬영되었으며 10 건의 Lung SABR plan($Eclipse^{TM}$ ver 10.0.42, Varian, the USA)에서 anisotropic analytic algorithm (AAA, ver. 10, Varian Medical Systems, Palo Alto, CA, USA)을 이용하여 각각 1.0, 3.0, 5.0 mm의 calculation grid로 계산하였다. 결 과 : 10 건의 Lung SABR plan에서 1.0 mm calculation grid를 사용한 경우 $V_{98}$이 각각 처방선량의 약 $99.5{\pm}1.5%$ 였으며 Dmin이 각각 처방선량의 약 $92.5{\pm}1.5%$ 였고 Homogeneity Index(HI)는 약 $1.0489{\pm}0.0025$로 나타났다. 3.0 mm calculation grid를 사용한 경우 $V_{98}$이 각각 처방선량의 약 $90{\pm}4.5%$였으며, Dmin이 각각 처방선량의 약 $87.5{\pm}3%$ 였고 HI가 약 $1.07{\pm}1$로 나타났다. 5.0 mm calculation grid를 사용한 경우 $V_{98}$이 각각 처방선량의 약 $63{\pm}15%$ 였으며, Dmin이 각각 처방선량의 약 $83{\pm}4%$ 였고 HI가 약 $1.13{\pm}0.2$로 나타났다. 결 론 : 1.0 mm calculation grid의 계산 시간이 3.0 mm, 5.0 mm 보다 오래 걸렸지만 grid의 간격이 좁을수록 상대적으로 작은 PTV를 갖는 plan의 정확성을 향상시키는 것으로 나타났다. 또한 Lung과 같이 비교적 넓게 퍼져 있으며 밀도가 낮은 장기의 작은 PTV를 치료해야 하는 경우에는 1.0 mm의 calculation grid를 사용하는 것이 좋을 것으로 사료된다.
목 적: 방사선치료계획에 있어서 정상조직과 치료부위의 선량 분포는 매우 중요하다. 이에 본원에서는 유방암 환자를 대상으로 Three-dimensional conformal radiation therapy (3D-CRT), Helical tomotherapy (TOMO)의 방법으로 방사선치료계획을 세웠으며 이에 선량분포를 분석하여 실제 임상에서의 적용여부를 알아보고자 한다. 대상 및 방법: 20명의(좌측: 10명, 우측: 10명) 유방보존절제술 환자를 대상으로 시행하였으며 방법으로는 같은 조건에서 3D-CRT는 Philips사의 Pinnacle을, TOMO는 TomoTherapy사의 TOMO Planning System을 이용해 치료계획을 세웠다. Dose-Volume Histogram (DVH)의 prescribed dose (PD)에 대한 PTV의 Homogeneity index (HI)와 Conformity index (CI)를 구하였고, 정상조직의 dose- volume 관계를 비교하였다. 결 과: Homogeneity index (HI)와 Conformity, index (CI)는 TOMO에서 우수한 결과를 나타났다. $V_{-50-IB-NPTV}$ (the percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose)는 3D-CRT: 40.4%, TOMO: 18.3%, $V_{20-IL}$ (the average ipsilateral lung volume percentage receiving 20% of the prescribed dose)는 3D-CRT: 4.8%, TOMO: 14.2%, $V_{20-10H}$ (the average heart volume percentage delivered 20% and 10% of the prescribed dose in left breast cancer)는 3D-CRT: 1.6%, 3% TOMO: 9.7%, 26.3%의 결과를 보여준다. 결 론: 유방암 환자의 방사선치료계획 방법들은 PTV에서 원하는 선량분포를 보여줬다. 그러나 TOMO는 좋은 Homogeneity index (HI), Conformity index (CI)와 Breast를 보호하는 장점이 있는 반면에 Lung과 Heart에서는 많은 피폭선량이 있음을 알 수 있기에 TOMO의 방사선치료계획시 주의해야 할 점으로 사료된다.
Background: Current therapy for the treatment of neuropathic pain is often unsatisfactory. Considerable variation in treatment pattern still exists in spite of availability of sufficient literature from various guidelines. Recent Indian market data suggested that the utilization (sale) of drugs such as amitriptyline, pregabalin, and gabapentin was more for low-dose unit packs than that of the high-dose unit packs, raising the belief that these drugs are prescribed at a lower dose than is actually recommended in the guidelines. To test this hypothesis, a survey was conducted across speciality throughout the country to observe the prescription pattern of these drugs amongst the health care providers in India. Methods: Three hundred fifty survey forms were distributed of which 281 forms were included for analysis. Results: It was observed that the commonly used initiation and maintenance dose for amitriptyline, pregabalin, and gabapentin was 5-10 mg/day, 50-75 mg/day, and 100-300 mg/day, respectively. The reason to select the lower dosages was to have a balancing effect to achieve good efficacy with minimum side effects. Care-givers reported no side effects/not many side effects as a reason in 22.2%, 16.88%, and 23.86% patients with amitriptyline, pregabalin, and gabapentin, respectively. Sedation and giddiness were commonly reported with all three drugs. Conclusions: Commonly prescribed drugs for management of neuropathic pain, such as amitriptyline, pregabalin, and gabapentin are preferred at lower doses in Indian clinical settings. Acceptable efficacy and low tolerance to the standard dosage is believed to be the reason behind the prescribed dose.
The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.
목 적 : 방사선 치료 시 치료기법에 따라 피부에 흡수되는 선량은 달라진다. 본 연구에서는 유방전절제술을 시행한 환자의 방사선 치료 시 치료 기법에 따른 표면선량 및 깊이에 따른 피부선량을 평가하고자 한다. 대상 및 방법 : 조직등가물질로 구성된 팬톰(I'mRT, IBA)을 이용하여 전산화단층촬영을 시행 한 후 치료계획시스템에 의해 인체의 흉벽과 같이 가상의 표적과 정상조직을 설정하였다. 총 5가지의 치료계획(Wedged Tangential technique, 4-field IMRT, 7-field IMRT, TOMO DIRECT, TOMO HELICAL)에 대해 6MV 광자선을 이용해 최적의 치료계획을 수립하였다. 흉벽의 표면선량을 측정하기 위해 Gafchromic EBT3필름 이용하여 팬톰의 표면에 밀착 시킨 후 내측(0~4 cm), 중심측(4~12 cm), 외측(12~16 cm)으로 구분하여 분석 하였고, 깊이에 따른 피부선량을 측정하기 위해 팬톰 단면 사이에 필름을 삽입 후 측정하여 흉벽의 내측(3지점), 중심측(4지점), 외측(3지점)에 대해서 1~6 mm 깊이 별로 측정하여 분석하였다. 결 과 : 흉벽의 표면선량 측정결과 처방선량 기준으로 TOMO DIRECT에서 47~70%로 가장 높게 측정 되었으며, 7-field IMRT의 경우 35~46%로 가장 낮은 선량을 보였다. 깊이에 따른 피부선량 측정결과 TOMO DIRECT와 TOMO HELICAL에서 다른 치료기법에 비해 1 mm, 2 mm, 5 mm깊이에서 처방선량의 75%, 80%, 90% 이상으로 모든 영역에서 상대적으로 높은 선량이 측정 되었으며, 특히 TOMO DIRECT의 경우 접선인자 영향에 의해 중심 측의 1 mm, 2 mm깊이에서 처방선량의 80%, 90%이상의 선량이 측정 되었다. 결 론 : 유방전절제술을 시행한 환자의 방사선 치료 시 선형 가속기를 이용한 치료 기법에 비해 TOMO DIRECT와 TOMO HELICAL에서 표면 및 피부선량이 높게 나타났으며, 표면으로부터 1 mm깊이의 피부영역에서 75% 이상의 충분한 선량을 전달 할 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.