• 제목/요약/키워드: Preoperative implant planning

검색결과 25건 처리시간 0.028초

Preoperative implant planning considering alveolar bone grafting needs and complication prediction using panoramic versus CBCT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제44권3호
    • /
    • pp.213-220
    • /
    • 2014
  • Purpose: This study was performed to determine the efficacy of observers' prediction for the need of bone grafting and presence of perioperative complications on the basis of cone-beam computed tomography (CBCT) and panoramic radiographic (PAN) planning as compared to the surgical outcome. Materials and Methods: One hundred and eight partially edentulous patients with a need for implant rehabilitation were referred for preoperative imaging. Imaging consisted of PAN and CBCT images. Four observers carried out implant planning using PAN image datasets, and at least one month later, using CBCT image datasets. Based on their own planning, the observers assessed the need for bone graft augmentation as well as complication prediction. The implant length and diameter, the need for bone graft augmentation, and the occurrence of anatomical complications during planning and implant placement were statistically compared. Results: In the 108 patients, 365 implants were installed. Receiver operating characteristic analyses of both PAN and CBCT preoperative planning showed that CBCT performed better than PAN-based planning with respect to the need for bone graft augmentation and perioperative complications. The sensitivity and the specificity of CBCT for implant complications were 96.5% and 90.5%, respectively, and for bone graft augmentation, they were 95.2% and 96.3%, respectively. Significant differences were found between PAN-based planning and the surgery of posterior implant lengths. Conclusion: Our findings indicated that CBCT-based preoperative implant planning enabled treatment planning with a higher degree of prediction and agreement as compared to the surgical standard. In PAN-based surgery, the prediction of implant length was poor.

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

The Value of Computed Tomography Scan in Three-dimensional Planning and Intraoperative Navigation in Primary Total Hip Arthroplasty

  • Fabio Mancino;Andreas Fontalis;Ahmed Magan;Ricci Plastow;Fares S. Haddad
    • Hip & pelvis
    • /
    • 제36권1호
    • /
    • pp.26-36
    • /
    • 2024
  • Total hip arthroplasty (THA) is a frequently performed procedure; the objective is restoration of native hip biomechanics and achieving functional range of motion (ROM) through precise positioning of the prosthetic components. Advanced three-dimensional (3D) imaging and computed tomography (CT)-based navigation are valuable tools in both the preoperative planning and intraoperative execution. The aim of this study is to provide a thorough overview on the applications of CT scans in both the preoperative and intraoperative settings of primary THA. Preoperative planning using CT-based 3D imaging enables greater accuracy in prediction of implant sizes, leading to enhancement of surgical workflow with optimization of implant inventory. Surgeons can perform a more thorough assessment of posterior and anterior acetabular wall coverage, acetabular osteophytes, anatomical landmarks, and thus achieve more functional implant positioning. Intraoperative CT-based navigation can facilitate precise execution of the preoperative plan, to attain optimal positioning of the prosthetic components to avoid impingement. Medial reaming can be minimized preserving native bone stock, which can enable restoration of femoral, acetabular, and combined offsets. In addition, it is associated with greater accuracy in leg length adjustment, a critical factor in patients' postoperative satisfaction. Despite the higher costs and radiation exposure, which currently limits its widespread adoption, it offers many benefits, and the increasing interest in robotic surgery has facilitated its integration into routine practice. Conducting additional research on ultra-low-dose CT scans and examining the potential for translation of 3D imaging into improved clinical outcomes will be necessary to warrant its expanded application.

치과임플란트 치료와 관련된 상악구치부의 임상적 연구 (CLINICAL STUDY ON KOREAN POSTERIOR MAXILLAE RELATED TO DENTAL IMPLANT TREATMENT)

  • 이두한;이성현;황주홍;이정근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권1호
    • /
    • pp.27-31
    • /
    • 2010
  • Purpose of study: The purpose of this study was to provide adequate diagnostic guideline for the maxillary sinuses prior to dental implant treatment for edentulous posterior maxillary areas. For this purpose, our procedure involves the estimation of the remaining alveolar bone height, the examination of the anatomical variation in the maxillary sinuses (e.g. sinus septum), and the evaluation of the incidence of preoperative pathological conditions in the maxillary sinuses. Materials and Methods: We selected 189 patients to undergo computerized tomography (CT) in order to account for the posterior maxillary anatomy found in patients of Korean ethnicity. We evaluated the following using Dentascan software: Remaining alveolar bone height, incidence of sinus septum, and rate of preoperative pathologic conditions in the maxillary sinus. The average amount of remaining alveolar bone height was analyzed using the student's t-test for differences according to anatomical site, and the ANOVA was used for the differences according to age group with the level of significance set at 0.05. Results: Alveolar bone heights of upper first premolar, second premolar, first molar, and second molar was 12.24 mm, 10.37 mm, 7.16 mm, and 7.15 mm, respectively with statistical significance (P < 0.05). Incidence of sinus septum as an anatomic variation was 17 out of 189 cases (9.0%). Incidence of mucosal thickening as a pathologic variation was 82 out of 189 cases (43.4%). Conclusion: In treatment planning of posterior maxillary edentulous area of Koreans, the consideration of augmentation surgery for maxillary sinus is required in maxillary molar area before dental implant installation, and preoperative screening of the asymptomatic maxillary sinuses can be regarded as a reasonable preoperative procedure in the planning of dental implant treatment on the posterior maxillary edentulous area.

Prevention of Implant Malposition in Inframammary Augmentation Mammaplasty

  • Kim, Yoon Ji;Kim, Yang Woo;Cheon, Young Woo
    • Archives of Plastic Surgery
    • /
    • 제41권4호
    • /
    • pp.407-413
    • /
    • 2014
  • Background Implant malposition can produce unsatisfactory aesthetic results after breast augmentation. The goal of this article is to identify aspects of the preoperative surgical planning and intraoperative flap fixation that can prevent implant malposition. Methods This study examined 36 patients who underwent primary dual plane breast augmentation through an inframammary incision between September 1, 2012 and January 31, 2013. Before the surgery, preoperative evaluation and design using the Randquist formula were performed. Each patient was evaluated retrospectively for nipple position relative to the breast implant and breast contour, using standardized preoperative and postoperative photographs. The average follow-up period was 10 months. Results Seven of 72 breasts were identified as having implant malposition. These malpositions were divided into two groups. In relation to the new breast mound, six breasts had an inferiorly positioned and one breast had a superiorly positioned nipple-areolar complex. Two of these seven breasts were accompanied with an unsatisfactory breast contour. Conclusions We identified two main causes of implant malposition after inframammary augmentation mammaplasty. One cause was an incorrect preoperatively designed nipple to inframammary fold (N-IMF) distance. The breast skin and parenchyma quality, such as an extremely tight envelope, should be considered. If an extremely tight envelope is found, the preoperatively designed new N-IMF distance should be increased. The other main cause of malposition is failure of the fascial suture from Scarpa's fascia to the perichondrium through an inframammary incision. As well, when this fixation is performed, it should be performed directly downward to the perichondrium, rather than slanted in a cranial or caudal direction.

Mixed reality visualization in shoulder arthroplasty: is it better than traditional preoperative planning software?

  • Sejla Abdic;Nicholas J. Van Osch;Daniel G. Langohr;James A. Johnson;George S. Athwal
    • Clinics in Shoulder and Elbow
    • /
    • 제26권2호
    • /
    • pp.117-125
    • /
    • 2023
  • Background: Preoperative traditional software planning (TSP) is a method used to assist surgeons with implant selection and glenoid guide-pin insertion in shoulder arthroplasty. Mixed reality (MR) is a new technology that uses digital holograms of the preoperative plan and guide-pin trajectory projected into the operative field. The purpose of this study was to compare TSP to MR in a simulated surgical environment involving insertion of guide-pins into models of severely deformed glenoids. Methods: Eight surgeons inserted guide-pins into eight randomized three-dimensional-printed severely eroded glenoid models in a simulated surgical environment using either TSP or MR. In total, 128 glenoid models were used and statistically compared. The outcomes compared between techniques included procedural time, difference in guide-pin start point, difference in version and inclination, and surgeon confidence via a confidence rating scale. Results: When comparing traditional preoperative software planning to MR visualization as techniques to assist surgeons in glenoid guide pin insertion, there were no statistically significant differences in terms of mean procedure time (P=0.634), glenoid start-point (TSP=2.2±0.2 mm, MR=2.1±0.1 mm; P=0.760), guide-pin orientation (P=0.586), or confidence rating score (P=0.850). Conclusions: The results demonstrate that there were no significant differences between traditional preoperative software planning and MR visualization for guide-pin placement into models of eroded glenoids. A perceived benefit of MR is the real-time intraoperative visibility of the surgical plan and the patient's anatomy; however, this did not translate into decreased procedural time or improved guide-pin position.

안전한 임플란트 식립을 위한 하악골 내측면의 CBCT를 이용한 해부학적 연구 (An anatomical study on the mandibular medial surface by CBCT analysis for safer implant placement)

  • 이정교;김여갑
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권1호
    • /
    • pp.43-48
    • /
    • 2011
  • Introduction: This study examined the anatomical morphology of the medial surface of the posterior mandible using 3-dimensional cone-beam computed tomography (CT) images to reduce the number of complications related to dental implant placement. Materials and Methods: Fifty patients were enrolled in this study with an average age (${\pm}$standard deviation) of 44.28 (${\pm}13.05$). On the coronal views cone-beam CT of the first molars, the distance between the top of the canal and alveolar crest vertical distance (VD), the distance between the upper-most point of the canal and the point perpendicular to the lingual cortical margin of the mandible lingual distance (LD), the location of the starting point of VD for reducing from the vertical reference line (VD point), and the inclination of the mandibular medial surface (lingual inclination) were measured, and a statistical evaluation was performed using SPSS for Windows version 15.0. Results: The mean VD0 was $16.91{\pm}2.47\;mm$ and VDx decreased with increasing x value. The mean LD was $5.27{\pm}1.36\;mm$. The VD began to decrease at the mean location of $6.12{\pm}0.96\;mm$ from the vertical reference line. The mean lingual inclination was $1.52{\pm}0.72^{\circ}$. Conclusion: These results will assist in the accurate placement of dental implants and the reduction of complications, particularly in the case of preoperative implant planning using only 2-dimensional imaging methods. (ex. panoramic radiography)

컴퓨터 시뮬레이션 기반의 외과용 스텐트를 이용한 임플란트 시술과 영상융합기술을 이용한 평가 (Implant surgery based on computer simulation surgical stent and the assessment with the image fusion technique)

  • 이지호;김성민;팽준영;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권5호
    • /
    • pp.402-407
    • /
    • 2010
  • Introduction: The planning of implant surgery is an important factor for the implant prosthesis. Stereolithographic (SLA) surgical stents based on a computer simulation are quite helpful for clinicians to perform the surgery as planned. Although many clinical and technical trials have been performed for computed tomography (CT)-guided implant stents to improve the surgical procedures and prosthetic treatment, there are still many problems to solve. We developed a system of a surgical guide based on 3 dimensional (3D) CT for implant therapy and achieved satisfactory results in the terms of planning and operation. Materials and Methods: Fifteen patients were selected and 30 implant fixtures were installed. The preoperative CT data for surgical planning were prepared after obtaining informed consent. Surgical planning was performed using the simulation program, Ondemend3D In2Guide. The stents were fabricated based on the simulation data containing information of the residual bone, the location of the nerve, and the expected design of the prostheses. After surgery with these customized stents, the accuracy and reproducibility of implant surgery were evaluated based on the computer simulation. The data of postoperative CT were used to confirm this system using the image fusion technique and compare the implant fixtures between the planned and implanted. Results: The mean error was 1.18 (${\pm}0.73$) mm at the occlusal center, 1.23 (${\pm}0.67$) mm at the apical center, and the axis error between the two fixtures was $3.25^{\circ}C$ (${\pm}3.00$). These stents showed superior accuracy in maxilla cases. The lateral side error at the apical center was significantly different from the error at the occlusal center but there were no significant differences between the premolars, 1st molars and 2nd molars. Conclusion: SLA surgical stents based on a computer simulation have the satisfactory accuracy and are expected to be useful for accurate planning and surgery if some errors can be improved.

Mandibular Reconstruction with Free Fibular Flap and Dental Implant after Ablative Oral Cancer Surgery Using 3D RP Model: A Case Report

  • Kim, Duck-Hoon;Cha, Hyun-Suk;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.90-94
    • /
    • 2014
  • Reconstruction of the mandible after ablative oral cancer surgery requires esthetic and functional rehabilitation. Restoring facial symmetry and dentition need accurate preoperative surgical planning and meticulous surgical technique. Free fibular flap is most useful tools to reconstruct mandible because of its adequate length and height, simultaneous harvest of soft and hard tissues and placing dental implants. In this case report, recurred squamous cell carcinoma in the right mandible had been resected and free fibular flap was utilized for mandible reconstruction using 3D rapid prototype. Simulation surgery before dental implant placement has been performed for esthetic and functional prosthodontics.

How to optimize aesthetic outcomes in implant-based breast reconstruction

  • Nava, Maurizio Bruno;Catanuto, Giuseppe;Rocco, Nicola
    • Archives of Plastic Surgery
    • /
    • 제45권1호
    • /
    • pp.4-13
    • /
    • 2018
  • The evolution of breast reconstructive surgery keeps pace with the evolution of breast oncologic surgery. The reconstructive choice should always balance the optimal local control of disease and the best cosmetic result, reflecting an informed decision that is shared with the patient, who is always at the center of the decision-making process. Implant-based breast reconstruction following mastectomy represents a complex choice. In order to obtain optimal results, the following considerations are mandatory: thorough preoperative planning, a complete knowledge of the devices that are used, accurately performed surgery, and appropriate follow-up.