• 제목/요약/키워드: Preheated Air Combustion

검색결과 34건 처리시간 0.024초

고온, 희박공기 연소에 관한 실험적 연구 (An Experimental Study on High Temperature and Low Oxygen Air Combustion)

  • 정대헌;양제복;노동순;김원배
    • 한국연소학회지
    • /
    • 제3권1호
    • /
    • pp.49-57
    • /
    • 1998
  • High temperature preheated and diluted air combustion has been developed as the technology to realize higher thermal efficiency. In this type of combustion, there are many interesting phenomena which cannot be observed in room temperature air combustion. The characteristics of the combustion, investigated using a 3500 kcal/h LPG fired test facility, are described. The flame is demonstrated to have a blue and green in color and has a large volume. As the preheated air temperature increased up to $1000\;^{\circ}C$, the NOx emission incrased exponentially over a few hundred ppm with 11% $O_2$ correction. But, it drastically reducedabout 20ppm when the air was diluted from 21% $O_2$ to 5% $O_2$.

  • PDF

부분 예혼합 화염의 예열공기 연소특성 (Preheated Air Combustion Characteristics of Partially Premixed Flame)

  • 이승영;이종호;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.65-70
    • /
    • 2001
  • OH radical and NOx have been measured in a methane-air partially premixed flame using PLIF technique to define preheated air combustion characteristics. The temperature of mixture is determined by 300K, 400K, 600K and 800K below the auto-ignition temperature respectively. Flame height increases as equivalence ratio increased. As initial enthalpy is supplied, the radius of flame was increased and much amount of yellow flame in rich equivalence ratio was observed. This is due to the faster burning velocity. Also initial oxidization begins earlier as the initial temperature of mixture increased. It means that height of premixed flame front decreased. This phenomenon can be observed OH PLIF image. The qualitative analysis of OH concentration in the PLIF image shows that overall OH concentration increases with equivalence ratio and the initial temperature of mixture increased. At the preheating temperature goes up, axial gradient of OH concentration is less steep than that of lower temperature condition. This may identify that combustion reacts continuously, so preheated air combustion can evade the local heating and make high temperature indiscriminately in the overall reaction zone.

  • PDF

절환주기 변화에 다른 축열 연소기의 연소특성 (Combustion Characteristics of A Regenerative Combustor with the Change of Alternating Period)

  • 양병옥;임인권
    • 한국연소학회지
    • /
    • 제4권1호
    • /
    • pp.95-103
    • /
    • 1999
  • Experimental study on combustion characteristics of a regenerative combustor has performed. High-temperature air combustion in the regenerative combustor is obtained through heat recovery from exhaust gas flow by porous ceramic materials and through alternation of air flow direction through the combustor. Temperature field, CO and NOx emission with respect to the frequency of alternation are measured. It is found that at initial stage of the alternation, temperature of inlet section of main combustion chamber is increased sharply since both high temperature air preheated by the ceramics and prompt fuel injection results in rapid combustion. Following this initial stage, combustion temperature is reduced as the preheated air temperature is reduced. However peak temperature in the chamber and exhaust gas temperature are decreased as the alternation period is reduced, increased temperature of ceramic is observed. CO and NOx emission with respect to the alternation period is also examined. It is found that there exists a range of optimum alternating period for CO and NOx emission characteristics.

  • PDF

가스터어빈 연소기의 화염 안정화와 제어 (Flame Stabilization and Control in Gas Turbine Combustor)

  • 최경민
    • 한국분무공학회지
    • /
    • 제8권4호
    • /
    • pp.24-30
    • /
    • 2003
  • This paper presents the characteristics of lifted height and flame length from non-premixed jet flames in highly preheated air to investigate the detail combustion mechanism in the gas turbine or HCCI engine, etc. Special attention was paid to the effect of preheated air temperature, oxygen concentration and fuel injection flow rate on flame length and lifted hight. By using highly preheated air, stable flames were formed even in low oxygen concentration condition. The lifted height increased with decreasing preheated air temperature, where the flame length showed opposed phenomena. The flamelet model, which is thought to have very thin flamelet, is difficult to applicable to the present flame conditions which is formed In low oxygen concentration in highly preheated air.

  • PDF

제트확산염의 고온공기연소특성에 관한 실험적 연구 (An Experimental Study of the Characteristics with High Temperature Air Combustion in Jet Diffusion Flames)

  • 조은성;대야건;소림수소;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.89-94
    • /
    • 2003
  • For the development of high efficiency and low emission combustion systems, high temperature air combustion technology has been tested by utilizing preheated air over 1100 K and exhaust gas recirculation. In this system, combustion air is diluted with large amount of exhaust gases ($N_2$, $CO_2$), such that the oxygen concentration is relatively low in the reaction zone, leading to low flame temperature. Since, the temperature fluctuations and sound emissions form the flame are small and flame luminosity is low, the combustion mode is expected to be flameless or mild combustion. Experiment was performed to investigate the turbulent flame structure and $NO_X$ emission characteristics in the high temperature air combustion focused on coflowing jet diffusion flames which has a fundamental structure of many practical combustion systems. The effect of turbulence has also been evaluated by installing perforated plate in the oxidizer inlet nozzle. LPG was used as a fuel. Results showed that even though $NO_X$ emission is sensitive to the combustion air temperature, the present high temperature air combustion system produce low $NO_X$ emission because it is operated in low oxygen concentration condition in excess of dilution.

  • PDF

고온공기를 이용한 제트확산화염의 연소특성에 관한 실험 (Experiment on the Characteristics of Jet Diffusion Flames with High Temperature Air Combustion)

  • 조은성;대야건;소림수소;정석호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.359-364
    • /
    • 2004
  • For the development of high efficiency and low emission combustion systems, high temperature air combustion technology has been tested by utilizing preheated air over 1100 K and exhaust gas recirculation. In this system, combustion air is diluted with large amount of recirculated exhaust gases, such that the oxygen concentration is relatively low in the reaction zone, leading to low flame temperature. Since, the temperature fluctuations and sound emissions from the flame are small and flame luminosity is low, the combustion mode is expected to be flameless or mild combustion. Experiment was performed to investigate the turbulent flame structure and NO$_x$ emission characteristics in the high temperature air combustion focused on coflowing jet diffusion flames which has a fundamental structure of many practical combustion systems. The effect of turbulence has also been evaluated by installing perforated plate in the oxidizer inlet nozzle. LPG was used as a fuel. Results showed that even though NO$_x$ emission is sensitive to the combustion air temperature, the present high temperature air combustion system produce low NO$_x$ emission because it is operated in low oxygen concentration condition by the high exhaust gas recirculation.

대향류 확산화염의 고온공기 연소특성에 관한 수치해석 (A Numerical Analysis of the Characteristics with High Temperature Air Combustion in Counterflow Diffusion Flame)

  • 조은성;히데아키 코바야시;정석호
    • 한국연소학회지
    • /
    • 제8권4호
    • /
    • pp.9-14
    • /
    • 2003
  • High temperature air combustion technology has been utilized by using preheated air over 1100 K and excessive exhaust gas recirculation. Numerical analysis was performed to investigate the combustion characteristics with high temperature deficient oxygen air combustion by adopting a counterflow as a model problem accounting for detailed chemical kinetics. Methane($CH_4$) was used as a test fuel and calculated oxidizer conditions were low temperature high oxygen (300K, $X_{O2}=0.21$) and high temperature low oxygen (1300K, $X_{O2}=0.04$) conditions. The latter case showed that the flame temperature is lower than the former case and its profile showed monotonic decrease from oxidizer to fuel side, without having local maximum flame temperature at high stretch rate. Also, heat release rate was one order lower and it has one peak profile because of low oxygen concentration and heat release rate integral is almost same for stretch rate. High temperature low oxygen air combustion shows low NO emission characteristics.

  • PDF

층류 예혼합 화염의 예열공기 연소특성 (Characteristics of Preheated Air Combustion in a Laminar Premixed Flame)

  • 이종호;이승영;한재원;장영준;전충환
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.1039-1046
    • /
    • 2002
  • Co-flow axisymmetric laminar premixed flame of methane was used to study the influence of air temperature and $N_2$ addition on the flame structure, temperature field and emission characteristics. OH 2-D images and temperatures along the centerline were measured experimentally by PLIF and CARS techniques respectively to observe the influences of dilution and thermal effects of $N_2$ in the gas mixture. Also, the concentration of NOx was measured at each condition by gas analyser to see the suppression effect of N2 addition on NOx emissions. It was found that OH concentrations distribute widely as air temperature goes higher, while the effect of $N_2$ addition is not significant. But $N_2$ addition highly contributes to the flame front and NOx emissions which was argued to be due to the reduction of flame temperature. In accordance with experimental study, numerical simulation using CHEMKlN code was carried out to compare the temperature results with those acquired by CARS measurement, and we could find that there is good agreement between those results.

고온공기이용 오일 연소기술 (An Experimental Study on Oil Combustion Technology with High Temperature Preheated Air)

  • 김원배;양제복
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.17-23
    • /
    • 2002
  • The objective of this study is to develop a new oil combustion technology concerning industrial furnaces and kilns, not only to save energy but also to reduce environmental emissions. Of many kinds of such technologies we chose the high temperature air combustion technology which was initiated by the British steel company in '80s and developed further by the American burner company "North American". In this study it was carried out to test regenerative burner experimentally and to have an applicability to industry. From the variation of configuration of gas nozzle and hot test on the temperature distribution and NOx, it was found out that the reduction of NOx was due to the effect of internal gas recirculation, which will be caused by air emitting velocity from burner nozzle.

  • PDF

축열버너의 연소특성에 대한 실험적 연구 (An Experimental Study on Combustion Characteristics of Regenerative Gas Burner)

  • 양제복;김원배;노동순
    • 한국연소학회지
    • /
    • 제5권1호
    • /
    • pp.99-108
    • /
    • 2000
  • Regenerative burner is a product of new combustion technology for realizing higher thermal efficiency and lower emissions, moreover utilizing very high preheated air temperature up to $1,000^{\circ}C$. In this study the experimental study was carried out to find out a combustion characteristics breaking the old combustion concept. From the variation of configuration of gas nozzle and hot test on the temperature distribution and NOx, CO, it was found out that the performance of regenerative burner was better than that of existing burner, mainly due to the effect of internal gas recirculation.

  • PDF