• Title/Summary/Keyword: Preformed metal crown

Search Result 4, Processing Time 0.018 seconds

Changes of Occlusion following the Placement of Preformed Metal Crown to the Permanent First Molar in Children and Adolescents (소아청소년에서 제1대구치의 기성금속관 수복 후 교합 변화)

  • Kim, Jiwoong;Lee, Nanyoung;Jih, Myeongkwan;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.45-56
    • /
    • 2022
  • The purpose of this study is to evaluate changes of occlusion following the placement of preformed metal crown in the permanent first molar affected by severe caries or hypomineralization. The study was conducted on 24 patients who met the criteria among the patients with occlusion in the permanent first molar reaching the occlusal plane. Restorative treatment was performed on one first molar using preformed metal crown. Before treatment, immediately after treatment, after 4 weeks, and after 8 weeks, the T-scan III was used for measuring distribution of bite force at the maximum intercuspal position, and overbite was measured with digital vernier calipers and change of dental midline was surveyed. After 8 weeks, questionnaires survey was conducted. In most cases, immediately after treatment, the distribution of bite force between the restored side and non-restored side of arch was reversed compared to before treatment, and the overbite was decreased. However, after 4 weeks, bite force of the left and right side was balanced and the distribution of bite force on the restored and non-restored permanent first molars had similar values. Also, the changed overbite and midline were returned to pre-treatment status and there was no significant temporomandibular joint and masticatory discomfort after treatment. In this study, it was confirmed that spontaneous occlusal equilibrium was achieved one month after the placement of preformed metal crown.

Retrospective Study on the Survival Rate of Preformed Metal Crowns in Permanent First Molars (제1대구치 기성금속관 생존율에 관한 후향적 연구)

  • Oh, Nayoung;Nam, Soonhyeun;Lee, Jaesik;Kim, Hyunjung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.140-147
    • /
    • 2020
  • This study analyzed the longevity of preformed metal crowns (PMCs) in first permanent molars and evaluated factors influencing their survival during a long-term follow-up period. In all, 115 first permanent molars treated with PMCs between June 2008 and June 2018 were retrospectively analyzed. The overall combined success rate for the study group was 84.3%. The 5-year survival rate was 82.8%. Multivariate Cox regression analyses identified distal cavities and mandibular PMC placement as risk factors for restoration failure. Careful placement of PMCs at the final try-in stage augments the longevity of the crown.

Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician (치과기공사국가시험 문항개발기준안연구)

  • Lee, Duck-Hye;Chung, In-Sung;Han, Chang-Sik
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF

Development of Organic Paste Porcelain for Fixed Prostheses (유기조성물을 이용한 페이스트형 일반도재 시스템)

  • Han, Jung-Suk;Lee, Myung-Hyun;Kim, Dae-Hyun;Chung, Hun-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.109-120
    • /
    • 2004
  • INTRODUCTION: The build-up method has been used for application of porcelain powder on the metal framework to make final tooth shape conventionally. This method takes time and need skill to mimic final shade and shape of porcelain fused to metal crown. The purpose of this study was to develop standard shape and shade laminating porcelain forms to reduce build-up time. METHODS: To make tooth form porcelain paste, several liquid organic compounds were added to conventional feldspathic porcelain. The amount of additives and rheologic property were tested to find out best composition. Comparison of mixing methods to reduced porosity, proper heating schedule, and measurement of shrinkage amount and residual organic materials were performed to set-up standard procedures. Finally, biaxial flexural strength and color of preformed laminated paste porcelain were compared with those of porcelain which fabricated by the conventional build-up method. RESULTS: There was no significant difference in physical properties and color stability between two fabrication methods after various testing methods. Conclusion: This new build-up method can be applied to fabricate the PFM crown and bridge without any loss of strength and optical properties.