• 제목/요약/키워드: Predischarge current

검색결과 11건 처리시간 0.046초

불평등전계중에서 임펄스전압에 대한 $SF_6$ 기체의 전구방전과정의 분석 (Analysis of Predischarge Processes of $SF_6$ Gas Stressed by lmpulse Voltages under Nonuniform Electric Field)

  • 이복희;이경옥;이창준;백승권
    • 한국전기전자재료학회논문지
    • /
    • 제13권1호
    • /
    • pp.85-93
    • /
    • 2000
  • In this paper, the predischarge propagation processes of SF\ulcorner gas stressed by impulse voltages under nonuniform electric field perturbed by a needle protrusion are described. The statistical and formative time-lags and the time interval between leader pulses were investigated on the basis of the predischarge current measured in the gas pressure range of 0.1~0.5 MPa. The predischarge current is closely related to the waveform, amplitude and polarity of applied votages, the gas pressure and the gap geometry. Both the positive and negative predischarge processes in nonuniform electric field develop in a regime of stepwise leader propagation leading to electrical breakdown. The mean of the time interval between leader pulses gives about a factor of 10 higher for the negative than for the positive leader current puls-es. According as the gas pressure increases, the statistical time-lag was almost unchangeable, but the formative time-lag was gradually decreased.

  • PDF

SF(sub)6-$N_2$혼합가스중에 뇌임펄스전압에 의해 형성된 불평등전장에서의 전구방전현상 (Predischarge Phenomena in Nonuniform Fields Caused by Lightning Impulse Voltages in SF(sub)6-$N_2$Mixtures)

  • 이복희;이경옥;백승권
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권6호
    • /
    • pp.288-295
    • /
    • 2001
  • Predischarges in nonuniform electric field stressed by lightning impulse voltagesin SF(sub)6-$N_2$mixtures are initiated by streamer coronas. Due to field ehnancement at a protrusion point of electrodes new ionization processes occur and a precursor, which leads to a first leader, is created. The leader proceeds step by step to the opposite electrode and the final jump bridges the test gap. It was found that the predischarge is propagated with a leader mechanism of stepwise expansion from the predischarge current waveforms measured by a shunt. The predischarge current is closely related to the amplitude and polarity of applied voltages, the gas pressure and the gap geometry. The time intervals between step leaders for the positive and negative polarities were inversely proportional to V.P$^2$. When the gas pressure increases in the positive polarity, statistical time lag to statistical time lag to streamer corona inception increase slightly, but the formative time lag to flashover is significantly decreased.

  • PDF

불평등 전계중에서 $SF_6$가스의 절연특성 (Dielectric Characteristics of $SF_6$ Gas in Inhomogeneous Field)

  • 이창준;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1870-1872
    • /
    • 1996
  • This paper presents dielectric characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The propose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane and two needles-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was 22 mm and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

이격거리가 큰 전극의 공기 절연파괴에 영향을 미치는 인자측정에 관한연구 (A Study on the Measurements of Parameters Affecting the Breakdown Mechanism of a Large Air Spacing)

  • 조연옥;최영욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.756-760
    • /
    • 1988
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/${\mu}s$ - 5cm/${\mu}s$, electric field intensity of 2kv/cm, predischarge current of 1.2A - 1.6A, the charges injected into the air gap of 11 - 40 ${\mu}$C for 400-887kV impulse voltages.

  • PDF

이격거리가 큰 전국의 공기절연파괴 현상시 발생하는 인자측정에 관한 연구 (A Study on the Measurements of Discharge Parameters in Case of the Switching Impulse Breakdown of a Large Air Spacing)

  • 최영욱;조연옥
    • 대한전기학회논문지
    • /
    • 제40권12호
    • /
    • pp.1290-1295
    • /
    • 1991
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/x10S0-6Ts - 5cm/x10S0-6Ts, electric field intensity of 2kv/cm, predischarge current of 1.2-1.6A, the charges injected into the air gap of 11-40x10S0-6TC for 400-887kV impulse voltages.

  • PDF

불평등전계중에서 VFTO에 의한 $SF_6$가스의 방전특성 (Dielectric Characteristics of $SF_6$ Gas Stressed by VFTO in inhomogeneous Field)

  • 이복희;이창준;안창환;이경옥;하성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.282-284
    • /
    • 1996
  • This paper presents prebreakdown characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The purpose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was22 mm, and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

온도변화에 따른 $SF_{6}/N_{2}$ 혼합가스의 절연특성 (Breakdown Characteristics of $SF_{6}/N_{2}$ Gas Mixtures According to a change in Temperature)

  • 이복희;이봉;최종혁;백영환;정동철;김성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1455-1456
    • /
    • 2007
  • This paper presents the experimental results on impulse breakdown characteristics under a highly non-uniform electric field in $SF_{6}/N_{2}$ gas mixtures according to a change in temperature. Test temperature ranges from $-25^{\circ}C$ to $25^{\circ}C$. The impulse predischarge breakdown developments are investigated by the measurements of current pulse and discharge luminous events. As a result, the predischarge development mechanisms for both positive and negative polarities are same. When increasing the temperature, breakdown voltage due to lightning impulse voltage is increased in negative polarity. On the other hand, when increasing the temperature, breakdown voltage due to lightning impulse voltage is not changed in positive polarity.

  • PDF

Electrical Properties Associated with Discharge Developments in Water Subjected to Impulse Voltages

  • Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.156-162
    • /
    • 2010
  • This paper describes electrical and optical characteristics of discharge developments in water under inhomogeneous fields caused by impulse voltages. Predischarge current and discharge light images were observed for different water resistivities and applied voltages between the hemispherical water tank and the needle electrode. The electrical parameters characterizing discharge developments are analyzed based on the discharge light images and voltage-current (V-I) curves, and electrical resistances derived by voltage and current waveforms. As a result, when the streamer corona is initiated at the tip of the needle electrode, the transient resistance suddenly drops and V-I curves form a 'loop'. The length of streamer propagation is increased with increasing peak value of the applied voltage, and the streamer corona extension is enlarged with increasing water resistivity. The electrical resistances before streamer corona initiation are rarely changed by different applied voltages. On the other hand, the electrical resistances after streamer corona initiation are found to be inversely proportional to the peak value of the applied voltage, and the decreasing rates for higher water resistivities are much higher than those for lower water resistivities. The time to streamer corona initiation and the time to the second current peak become shorter as the voltage increases. Finally, the calculated resistances after streamer corona initiation are almost the same trace of measured resistances, but they are smaller than the measured values.

불평등전장에서 $SF_6$ 기체의 뇌임펄스 절연파괴특성 (Characteristics of lightning impulse breakdowns in inhomogeneous $SF_6$ gas gap)

  • 이복희;최휘성;오성균;이봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1921-1923
    • /
    • 2004
  • V-p characteristics and the discharge luminous characteristics in inhomogeneous $SF_6$ gas gap under the positive and negative lightning impulse voltages are presented. The test gap was composed of the plane-to-plane with a needle-shaped protrusion. The applied voltage and the predischarge current were measured by the electric field sensor and the shunt of 50 ${\Omega}$, respectively. The light emission signals were observed by a photomultiplier tube, and a high-speed camera. In a consequence, the dielectric strengths of $SF_6$ gas gap under positive lightning impulse voltages were independent of the gas pressure. In the presence of the positive polarity, the branches of discharge channel were created and the directions of the discharge paths were random. On the other hands, the discharge paths of the negative polarity were more thicker and brighter.

  • PDF

불평등전계 중에서 $SF_{6}-N_{2}$ 혼합기체의 절연파괴 특성 (Breakdown Characteristics of $SF_{6}-N_{2}$ Mixtures in Nonuniform electric Field)

  • 이복희;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1999-2001
    • /
    • 2000
  • Impulse breakdown voltage characteristics of sulphur-hexafluoride/nitrogen ($SF_{6}-N_{2}$) mixtures were presented. The applied voltages were the positive and negative lightning impulse (1.2/44${\mu}s$) and oscillating impulse ($0.4{\mu}s$/2.08MHz) voltages. The predischarge current was observed to clarify the breakdown mechanism. The electrode system was consisted of plane to plane configuration with a needle-shaped protrusion whose length and diameter are 10mm and 1mm. The measurements were carried out at the gas pressure of mixtures up to 0.5MPa with nitrogen concentrations varying from 5 to 20%. The electrical breakdown in $SF_{6}-N_{2}$ mixtures develops with steplike pulses in leader mechanism. The minimum breakdown voltages for the negative lightning and oscillating impulse voltages were higher than those for the positive.

  • PDF