• Title/Summary/Keyword: Preconcentration

Search Result 155, Processing Time 0.023 seconds

Determination of Copper Ion with 2-Mercaptobenzimidazol Immobilized on Surfactant-Coated Alumina (계면활성제를 코팅한 알루미나에 부동화한 2-Mercaptobenzimidazol을 이용한 구리이온의 정량)

  • Absalan, G.;Goudi, A.Aghaei
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.2
    • /
    • pp.141-146
    • /
    • 2007
  • The present paper describes a procedure for separation, preconcentration and determination of trace amount of copper in natural water samples by using 2-mercaptobenzimidazol as the complexing agent. The proposed method is based on the surfactant aggregation formed on γ-alumina by mixing sodium dodecyl sulfate and γ-alumina in water; 2-mercaptobenzimidazol was incorporated into inner hydrophobic part of produced ad-micelles in acidic media to produce an assemble suitable for preconcentration and determination of copper ion. Optimum experimental conditions for adsorption of μg/ml levels of copper ions from aqueous solution by the adsorbent have been reported. The copper ions were quantitively adsorbed by the sorbent over the pH range of 7.1-8.0 and were quantitatively desorbed afterward by using sulfosalycilic acid as the eluent. The determination of copper was not interfered in the presence of common metal ions. The procedure was applied for analysis of river water sample. Relative standard deviation was found to be 4.91%.

Novel Solid Phase Extraction Procedure for Some Trace Elements in Various Samples Prior to Their Determinations by FAAS

  • Sacmaci, Srife;Kartal, Senol;Sacmaci, Mustafa;Soykan, Cengiz
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.444-450
    • /
    • 2011
  • A novel method that utilizes poly(5-methyl-2-thiozyl methacrylamide-co-2-acrylamido-2-methyl-1-propanesulfonic acid-co-divinylbenzene) [MTMAAm/AMPS/DVB] as a solid-phase extractant was developed for simultaneous preconcentration of trace Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Ni(II), Pb(II), and Zn(II) prior to the measurement by flame atomic absorpiton spectrometry (FAAS). Experimental conditions for effective adsorption of the metal ions were optimized using column procedures. The optimum pH value for the simultaneously separation of the metal ions on the new adsorbent was 2.5. Effects of concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of the analytes were investigated. A high preconcentration factor, 100, and low relative standard deviation values, $\leq$1.5% (n = 10), were obtained. The detection limits (${\mu}gL^{-1}$) based on the 3s criterion were 0.18 for Cd(II), 0.11 for Co(II), 0.07 for Cr(III), 0.12 for Cu(II), 0.18 for Fe(III), 0.67 for Mn(II), 0.13 for Ni(II), 0.06 for Pb(II), and 0.09 for Zn(II). The validation of the procedure was performed by the analysis of two certified reference materials. The presented method was applied to the determination of the analytes in various environmental samples with satisfactory results.

Determination of Cd(II) after Preconcentration onto Microcrystalline p-Dichlorobenzene Loaded with 2-Mercaptobenzothiazole (2-Mercaptobenzothiazole이 내포된 p-Dichlorobenzene 미세결정으로 예비농축시킨 후 Cd(II) 정량)

  • Yoon, Ju-Im;Choi, Hee-Seon
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • A sensitive technique for the determination of trace Cd(II) in various real samples after preconcentration onto microcrystalline p-dichlorobenzene loaded with 2-mercaptobenzothiazole was developed. Several experimental conditions such as the pH of the sample solution, the amount of chelating agent 2-mercaptobenzothiazole, the amount of adsorbent p-dichlorobenzene-2-MBT, and the flow rate of sample solution were optimized. The interfering effects of various concomitant ions were investigated. Cu(II) interfered with more seriously than any other ions. However, the interference by Cu(II) could be overcome sufficiently by adjusting tartrate ion concentration to be 0.01M or by controlling the amount of 2-mercaptobenzothiazole contained in 0.20 g p-dichlorobenzene to be 0.12 g. The dynamic range, the correlation coefficient ($R^2$) and the detection limit obtained by this proposed technique were $0.5{\sim}30$ ng $mL^{-1}$, 0.9962, and 0.39 ng $mL^{-1}$, respectively. Thus, good results were obtained by the use of p-dichlorobenze as adsorbent matrix. For validating this proposed technique, the aqueous samples(wastewater, stream water, and reservoir water) and the plastic sample were used. Recovery yields of $93{\sim}104$ % were obtained. By F test, these measured data were not different from ICP-MS data at 95 % confidence level. Based on the results from the experiment, it was found that this proposed technique could be applied to the preconcentration and determination of Cd(II) in various real samples.

Determination and preconcentration of Cu(II) using microcrystalline p-Dichlorobenzene loaded with salicylaldoxime (Salicylaldoxime이 내포된 p-Dichlorobenzene 미세결정을 이용한 Cu(II)의 예비농축 및 정량)

  • Lee, Ha-Na;Choi, Hee-Seon
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.240-246
    • /
    • 2010
  • A technique for the determination of trace Cu(II) in various real samples by FAAS after the column preconcentration onto p-dichlorobenzene-SA adsorbent, which is microcrystalline p-dichlorobenzene loaded with salicylaldoxime (SA) has been developed. Several experimental conditions such as pH of the sample solution, the amount of chelating agent salicylaldoxime, the amount of adsorbent p-dichlorobenzene-SA, and flow rate of sample solution were optimized. The interfering effects of various concomitant ions were investigated. $CN^-$ interfered more seriously than any other ions. However, the interference by $1\;{\mu}g\;mL^{-1}\;CN^-$ could be overcome completely by controlling the concentration of Ni(II) to $20\;{\mu}g\;mL^{-1}$. The linear range, correlation coefficient ($R^2$) and detection limit obtained by this technique were $3.0\sim100\;ng\;mL^{-1}$, 0.9901, and $3.1\;ng\;mL^{-1}$, respectively. For validating this technique, the aqueous samples (wastewater, reservoir water and stream water) and the food samples (orange juice, fresh egg and skim milk) were used. Recovery yields of 93~104% were obtained. These measured mean values were not differents from ICP-MS data at 95% confidence level. The good results were obtained from the experiments using the rice flour certified reference material (CRM) sample. Based on the experimental results, it was found that this technique could be applied to the preconcentration and determination of Cu(II) for various real samples.

Preconcentration and Determination of Fe(III) from Water and Food Samples by Newly Synthesized Chelating Reagent Impregnated Amberlite XAD-16 Resin

  • Tokahoglu, Serife;Ergun, Hasan;Cukurovah, Alaaddin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1976-1980
    • /
    • 2010
  • A simple and reliable method has been developed to selectively separate and concentrate trace amounts of Fe(III) ions from water and food samples by using flame atomic absorption spectrometry. A new reagent, 5-hydroxy-4-ethyl-5,6-di-pyridin-2-yl-4,5-dihydro-2H-[1,2,4] triazine-3-thione, was synthesized and characterized by using FT-IR spectroscopy and elemental analysis. Effects of pH, concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of Fe(III) were investigated. The optimum pH was found to be 5. Eluent for quantitative elution was 10 mL of 2 M HCl. The preconcentration factor of the method, detection limit (3s/b, ${\mu}gL^{-1}$) and relative standard deviation values were found to be 25, 4.59 and 1%, respectively. In order to verify the accuracy of the method, two certified reference materials (TMDA 54.4 lake water and SRM 1568a rice flour) were analyzed. The results obtained were in good agreement with the certified values. The method was successfully applied to the determination of Fe(III) ions in water and food samples.

Preconcentration of Copper(II) Using Mesoporous Organo-Silicas and Determination by Flame Atomic Absorption Spectrometry (메조다공성 유기-실리카를 이용한 구리(II)의 예비농축과 불꽃원자 흡수분광법으로의 정량)

  • Moghimi, Ali
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.2
    • /
    • pp.155-163
    • /
    • 2008
  • .A simple and reproducible method for the rapid extraction and determination of trace amounts of copper(II) ions using mesoporous organo-silicas mesoporous silica and atomic absorption spectrometry is presented. Common coexisting ions did not interfere with the separation and determination. The preconcentration factor was 100 (1 ml elution volume) for a 100 ml sample volume. The limit of detection of the proposed method is 1.0 ng ml-1. The maximum sorption capacity of sorbent under optimum conditions has been found to be 5mg of copper per gram of sorbent. The relative standard deviation under optimum conditions was 2.8% (n=10). Accuracy and application of the method was estimated by using test samples of natural and synthetic water spiked with different amounts of copper(II) ion.

Analysis of Perchlorate in Water Using Ion Chromatograph with Preconcentration (이온크로마토그래프를 이용한 수중의 퍼클로레이트 농축 및 분석)

  • Kim, Hak-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.29-38
    • /
    • 2006
  • This study included the development of analytical method for determining perchlorate in water sample. The analytical condition was referred in EPA 314.0 method which use ion chromatography and the concentrator column was replaced by the guard column. Concentrating 10mL raw or treated water sample on to AGl6 guard column made it possible to get the LOD(Limit of Detection) of $0.73\;{\mu}g/L$. The total run time was 11 minutes and during run time next sample could be concentrated on AGl6 guard column. Compared to the Concentration method which needed manual operation, the Direct Injection method could screen the many water samples. The LOD of the Direct Injection method was higher and the sensitivity was lower than that of the Concentration method. The RSDs(Relative Standard Deviations) were lower than 2.5 % for peak height and 0.7 % for retention time in pre-concentration methods. This method Showed good reproducibility and reliability and it was thought the deviations of recovery value could be reduced by considering column capacity and making water sample homogeneous. Matrix Elimination could be done using the pre-concentration method if perchlorate were in complex matrix of sample.