• Title/Summary/Keyword: Precision medicine

Search Result 531, Processing Time 0.028 seconds

Simultaneous Pesticide Analysis Method for Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor and Trifluralin Residues in Agricultural Commodities Using GC-ECD/MS (GC-ECD/MS를 이용한 농산물 중 Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor 및 Trifluralin의 동시 분석)

  • Ahn, Kyung Geun;Kim, Gi Ppeum;Hwang, Young Sun;Kang, In Kyu;Lee, Young Deuk;Choung, Myoung Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.104-116
    • /
    • 2018
  • BACKGROUND: This experiment was conducted to establish a simultaneous analysis method for 7 kinds of herbicides in 3 different classes having similar physicochemical property as diphenyl ether(bifenox and oxyfluorfen), dinitroaniline (ethalfluralin and trifluralin), and chloroacetamide (metolachlor, pretilachlor, and thenylchlor) in crops using GC-ECD/MS. METHODS AND RESULTS: All the 7 pesticide residues were extracted with acetone from representative samples of five raw products which comprised apple, green pepper, Kimchi cabbage, hulled rice and soybean. The extract was diluted with saline water and directly partitioned into n-hexane/dichloromethane(80/20, v/v) to remove polar co-extractives in the aqueous phase. For the hulled rice and soybean samples, n-hexane/acetonitrile partition was additionally employed to remove non-polar lipids. The extract was finally purified by optimized Florisil column chromatography. The analytes were separated and quantitated by GLC with ECD using a DB-1 capillary column. Accuracy and precision of the proposed method was validated by the recovery experiment on every crop samples fortified with bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin at 3 concentration levels per crop in each triplication. CONCLUSION: Mean recoveries of the 7 pesticide residues ranged from 75.7 to 114.8% in five representative agricultural commodities. The coefficients of variation were all less than 10%, irrespective of sample types and fortification levels. Limit of quantitation (LOQ) of the analytes were 0.004 (etahlfluralin and trifluralin), 0.008 (metolachlor and pretilachlor), 0.006 (thenylchlor), 0.002 (oxyfluorfen), and 0.02 (bifenox) mg/kg as verified by the recovery experiment. A confirmatory technique using GC/MS with selected-ion monitoring was also provided to clearly identify the suspected residues. Therefore, this analytical method was reproducible and sensitive enough to determine the residues of bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin in agricultural commodities.

Result of Radiation Therapy of Sino-nasal Cancers Using Partial Attenuation Filter (투과성 필터를 이용하여 방사선 치료를 받은 부비동 및 비암의 치료 결과)

  • Kim, Jin-Hee;Kim, Ok-Bae;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.118-124
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study was to evaluate the survival and pattern of failure after radiation therapy of sino-nasal cancer using partial attenuation filer and wedged beams and to help radiotherapy planning of sino-nasal cancer. $\underline{Materials\;and\;Methods}$: Between February 1992 and March 2003, 17 patients with sino-nasal cancers underwent radiation therapy using partial attenuation filter at Dongsan Medical Center, Keimyung university. There were 9 male and 8 female patients. Patients' age ranged from 40 to 75 years (median 59 years). There were 10 patients of maxillary sinus cancer, 7 patiens of nasal cancer. The histologic type was squamous cell carcinoma in 11, adenoid cystic carcinoma in 4 and olfactory neuroblastoma in 2. The distribution of clinical stage by the AJCC system was 3 for stage II, 7 for III and 6 for IV. The five patients were treated with radiation alone and 12 patients were treated with surgery and postoperative radiation therapy. The range of total radiation dose delivered to the primary tumor was from 44 to 76 Gy (median 60 Gy). The follow-up period ranged from 3 to 173 months with median of 78 months. $\underline{Results}$: The overall 2 year survival rate and disease free survival rate was 76.4%. The 5 year and 10 year survival rate were 76.4% and 45.6% and the 5 year and 10 year disease free survival rate was 70.6%. The 5 year disease free survival rate by treatment modality was 91.6% for postoperative radiation group and 20% for radiation alone group, statistical significance was found by treatment modality (p=0.006). There were no differences in survival by pathology and stage. There were local failure in 5 patients (29%) but no distant failure and no severe complication required surgical intervention. $\underline{Conclusion}$: Radiation therapy of sino-nasal cancer using partial attenuation filter was safe and effective. Combined modality with conservative surgery and radiation therapy was more advisable to achieve loco-regional control in sino-nasal cancer. Also we considered high precision radiation therapy with dose escalation and development of multi-modality treatment to improve local control and survival rate in advanced sino-nasal cancer.

Validation of a Rapid Quantitative Method for the Residues of Nitrofuran Metabolites in Loach by Accelerated Solvent Extraction and HPLC Triple Quadrupole Mass Spectrometry

  • Ryu, Eun Chae;Han, Yun-jeong;Park, Seong-soo;Lim, Chul-joo;Choi, Sunok;Park, Se Chang
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.2
    • /
    • pp.85-93
    • /
    • 2016
  • A rapid method using HPLC-MS/MS has been developed for quantitative determination of the metabolites of nitrofurans, namely 3-amino-2-oxazolidone (AOZ), 5-morpholinomethyl-3-amino-2-oxazolidinone (AMOZ), 1-ammino-hydantoin (AHD) and semicarbazide (SEM) in loach. The extraction procedure was founded on simultaneous acidic hydrolysis and derivatization using 2-nitrobenzaldehyde (2-NBA) for 1 hour at $50^{\circ}C$, followed by purification with liquid-liquid extraction. Recovery was evaluated by spiking standards into blank samples at three levels (0.5, 1.0 and $2.0{\mu}g/kg$), and the mean recovery was 75.1-108.1%. Precision values expressed as the relative standard deviation (%RSD) were ${\leq}8.7%$ and ${\leq}8.5%$ for intra-day and inter-day precision, respectively. Linearity was studied in the range of $0.2-20{\mu}g/Kg$ for NBAOZ, $0.8-20{\mu}g/Kg$ for NBAMOZ, $0.2-20{\mu}g/Kg$ for NBAHD, and $0.1-20{\mu}g/Kg$ for NBSEM, and the obtained coefficient correlations (r) were ${\geq}0.99$ for all compounds. Limits of detection (LODs) for the derivatized nitrofuran metabolites were established at $0.06{\mu}g/Kg$ for NBAOZ, $0.24{\mu}g/Kg$ for NBAMOZ, $0.06{\mu}g/Kg$ for NBAHD, and $0.03{\mu}g/Kg$ for NBSEM. Limits of quantification (LOQs) were established at $0.2{\mu}g/Kg$ for NBAOZ, $0.8{\mu}g/Kg$ for NBAMOZ, $0.2{\mu}g/Kg$ for NBAHD, and $0.1{\mu}g/Kg$ for NBSEM. This simplified rapid method for reducing the derivatization and hydrolysis times can be applied to the determination of nitro-furan residues in loach.

Simultaneous determination of illegal galactagogue adulterants in supplement diets by LC-MS/MS

  • Lee, Ji Hyun;Cho, So-Hyun;Park, Han Na;Park, Hyoung Joon;Kim, Nam Sook;Park, Sung Kwan;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.171-178
    • /
    • 2018
  • Recently, for successful lactation, many breastfeeding mothers seek various products, including herbal medicine, dietary supplements, and prescribed medicines, to improve milk production. As demand for galactogogues grows, it is highly possible that pharmaceutical galactogogues may be adulterated with illegal products to maximize their efficacy. For continuous control and supervision of illegal products, we developed and validated a simple and sensitive LC-MS/MS method capable of simultaneously determining five galactogogues. Chromatographic separation was conducted using an Agilent Poroshell $120SB-C_{18}$ column with a mobile phase consisting of 20 mM ammonium formate (pH 5.4) and 100 % acetonitrile. The total run time was 13 min per analyte. The proposed method was performed according to the guidelines of the International Conference of Harmonization and it produced reliable results. This method showed high sensitivity and specificity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 0.01-0.82 ng/mL and 0.02-2.45 ng/mL, respectively, for the solid- and liquid-type samples. Specificity was evaluated by analyzing matrix-blank samples spiked with the target compounds at LOQ levels, which provided a good separation of all peaks without interference. Additionally, the repeatability and intermediate precision were typically <15 %, whereas the recovery was 80-120 % of the values obtained using blank samples. Thus, we concluded that this method could be used for the identification and quantification of galactogogues in food or herbal products.

A Study on GPU Computing of Bi-conjugate Gradient Method for Finite Element Analysis of the Incompressible Navier-Stokes Equations (유한요소 비압축성 유동장 해석을 위한 이중공액구배법의 GPU 기반 연산에 대한 연구)

  • Yoon, Jong Seon;Jeon, Byoung Jin;Jung, Hye Dong;Choi, Hyoung Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.597-604
    • /
    • 2016
  • A parallel algorithm of bi-conjugate gradient method was developed based on CUDA for parallel computation of the incompressible Navier-Stokes equations. The governing equations were discretized using splitting P2P1 finite element method. Asymmetric stenotic flow problem was solved to validate the proposed algorithm, and then the parallel performance of the GPU was examined by measuring the elapsed times. Further, the GPU performance for sparse matrix-vector multiplication was also investigated with a matrix of fluid-structure interaction problem. A kernel was generated to simultaneously compute the inner product of each row of sparse matrix and a vector. In addition, the kernel was optimized to improve the performance by using both parallel reduction and memory coalescing. In the kernel construction, the effect of warp on the parallel performance of the present CUDA was also examined. The present GPU computation was more than 7 times faster than the single CPU by double precision.

Study on ICT convergence in Lentinula edodes (Shiitake) cultivation system using Automated container (컨테이너형 수출용 버섯식물공장시스템설계 및 표고버섯 생산 연구)

  • Jo, Woo-Sik;Lee, Sung-Hak;Park, Woo-Ram;Shin, Seung-Ho;Park, Chang-Min;Oh, Ji-Hyun;Park, Who-Won
    • Journal of Mushroom
    • /
    • v.15 no.4
    • /
    • pp.264-268
    • /
    • 2017
  • In the 21st century, information and communication technology (ICT) worldwide presents a new vision for agriculture. Time and place, as well as the high-tech industry, to overcome barriers to the fusion of the so-called "smart agriculture," are changing the agricultural landscape. Core container production in precision agriculture for mushroom cultivation, optimal temperature, humidity, irradiation, self-regulation of factors such as carbon dioxide, and environment for mushroom cultivation were adopted. Lentinula edodes (shiitake) is an edible mushroom native to East Asia, cultivated and consumed in many Asian countries. It is considered to be medicinal in certain practices of traditional medicine. We used different controlled light sources (Blue-Red-White-combined LED, blue LED, red LED, and fluorescent light) with different LED radiation intensities (1.5, 10.5, and $20.5{\mu}mol/m^2s$ for LEDs) to compare growth and development. Mushrooms were treated with light in a 12-hour-on/12-hour-off cycle, and maintained in a controlled room at $19{\sim}21^{\circ}C$, with 80~90% humidity, and an atmospheric $CO_2$ concentration of 1,000 ppm for 30 days. Growth and development differed with the LED source color and LED radiation intensity. Growth and development were the highest at $10.5{\mu}mol/m^2s$ of blue LED light. After harvesting the fruit bodies, we measured their weight and length, thickness of pileus and stipe, chromaticity, and hardness. The $10.5{\mu}mol/m^2s$ blue-LED-irradiated group showed the best harvest results with an average individual weight of 39.82 g and length of 64.03 mm, pileus thickness of 30.85 mm and pileus length of 43.22 mm, and stipe thickness of 16.96 mm with fine chromaticity and hardness. These results showed that blue LED light at $10.5{\mu}mol/m^2s$ s exerted the best effect on the growth and development of L. edodes (shiitake) mushroom in the ICT-system container-type environment.

Bioequivalence Study of Toriem® Tablet to Motilium-M® Tablet (Domperidone Maleate 12.72 mg) Evaluated by Liquid Chromatography/Tandem Mass Spectrometry

  • Ryu, Ju-Hee;Choi, Sang-Jun;Lee, Myung-Jae;Lee, Jin-Sung;Kang, Jong-Min;Tak, Sung-Kwon;Seo, Ji-Hyung;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • The aim of the present study was to evaluate the bioequivalence of two domperidone maleate tablets, Motilium-$M^{(R)}$ Tablet (Janssen Korea Ltd., reference product) and $Toriem^{(R)}$ Tablet (Daewon Pharm. Co., Ltd., test product). Domperidone was extracted by liquid-liquid extraction using tert-butyl methyl ether and separated in less than 3 min on $C_{18}$ reverse-phase column using an isocratic elution. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z $426.1{\rightarrow}119.1$ and the m/z $837.4{\rightarrow}158.2$ transitions for domperidone and the internal standard (roxithromycin), respectively. Calibration curves, from $0.05{\sim}50$ ng/mL of domperidone, showed correlation coefficients (r) higher than 0.9941. Intra day and inter day precision (C.V. %) for quality control were ranged from 10.04 to 16.09% and from 10.87 to 18.69%, respectively. The lower limit of quantification (LLOQ) of domperidone was 0.05 ng/mL. The method described is precise and sensitive and has been successfully applied to the study of bioequivalence of domperidone in 24 healthy Korean volunteers. Twenty-four healthy male Korean volunteers received a single dose of each medicine ($2{\times}12.72\;mg$ domperidone maleate) in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of domperidone were monitored for over a period of 24 hr after the administration. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were within acceptable range of log 0.8 to log 1.25 (e.g., $log\;0.92{\sim}log\;1.05$ for $AUC_{0-t}$, $log\;0.81{\sim}log\;1.05$ for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that $Toriem^{(R)}$ tablet is bioequivalent to Motilium-$M^{(R)}$ tablet.

Evaluation of Pregnancy and Thyroid Function (임신과 갑상선 기능의 평가)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • During early pregnancy, before the development of a functioning thyroid gland, thyroid stimulating hormone (TSH) is a very sensitive marker of thyroid dysfunction during pregnancy. Normal values have been modified during gestation with a downward shift. The fetus is influenced by the TSH supplied by the mother. TSH and free thyroxine (FT4) concentrations vary during pregnancy and conventional units can vary between laboratories. A downward shift of the TSH reference range occurs during pregnancy, with a decrease in both the lower and upper limits of maternal TSH, relative to the typical non-pregnant TSH reference range. Each laboratory produces its own reference TSH and FT4 concentrations because there are many different assays that yield different results in pregnancy. Therefore, automated immunoassays used for serum FT4 analysis are still used widely, but the important considerations discussed above must be noted. The use of population-based, trimester-specific reference ranges remains the best way to handle this issue The slight downward shift in the upper reference range of TSH occurring in the latter first trimester (7~12 weeks) of pregnancy, typically not observed prior to 7 weeks. Their use indicates high or low levels in a quantitative manner independent of the reference ranges. These data highlight the importance of calculating population-based pregnancy-specific thyroid parameter reference intervals. A precision medicine initiative in this area will require the collection and analysis of a large number of genetic, biological, psychosocial, and environmental variables in large cohorts of individuals. Large prospective randomized controlled trials will be needed to resolve these controversies.

Validation of an LC/MS/MS Method for the Pharmacokinetic Study of Lercanidipine (염산레르카니디핀 체내동태 연구를 위한 혈청 중 레르카니디핀의 LC/MS/MS 정량법 검증)

  • Kim, Se-Mi;Kim, Hwan-Ho;Shin, Sae-Byeok;Kang, Hyun-Ah;Yoon, Hwa;Cho, Hea-Young;Kim, Yoon-Gyoon;Yang, Chan-Woo;Yong, Chul-Soon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.4
    • /
    • pp.223-227
    • /
    • 2007
  • A rapid, simple and sensitive LC/MS/MS method for the determination of lercanidipine in human serum was validated and applied to the pharmacokinetic study of lercanidipine. Lercanidipine and internal standard, amlodipine, were extracted from human serum by liquid-liquid extraction with hexan-isoamyl alcohol (100: 1, v/v) and analyzed on a $Symmetry^{(R)}$ MS $C_{18}$ column with the mobile phase of acetonitrile-0.2% aqueous formic acid (70: 30, v/v). Using MS/MS with multiple reaction monitoring (MRM) mode, lercanidipine and amlodipine were detected without severe interferences from human serum matrix. Lercanidipine produced a protonated precursor ion ($[M+H]^+$) at m/z 612.3 and a corresponding product ion at m/z 280.0. Internal standard produced a protonated precursor ion ($[M+H]^+$]) at m/z 409.0 and a corresponding product ion at m/z 238.0. The ruggedness of this method was investigated using quality control (QC) samples. This method showed linear response over the concentration range of 0.05-20 ng/mL with correlation coefficient greater than 0.999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ng/mL, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the developed method ranged from 85.51 to 112.2% for lercanidipine with overall precision (% C.V.) being 3.56-13.1%. This method showed good ruggedness (within 15% C.V.) and was successfully applied for the analysis of lercanidipine in human serum samples for the pharmacokinetic studies, demonstrating the suitability of the method.

A Convergence Study on the 5-axis Machining Technology using the DICOM Image of the Humerus Bone (위팔뼈 의료용 디지털 영상 및 통신 표준 영상을 이용한 5축 가공기술의 융합적 연구)

  • Yoon, Jae-Ho;Ji, Tae-Jeong;Yoon, Joon;Kim, Hyeong-Gyun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.115-121
    • /
    • 2017
  • The present study aimed to obtain basic knowledge of a customized artificial joint based on the convergence research of Digital Imaging and Communications in Medicine(DICOM) and 5-axis machining technology. In the case of the research method, three-dimensional modeling was generated based on the medical image of the humerus bone, and the shape was machined using a chemical wood material. Then, the anatomical characteristics and the modeling machining computation times were compared. The results showed that the Stereolithography (STL) modeling required twice more time for semi-finishing and 10 times more time for finishing compared to the Initial Graphics Exchange Specification(IGES) modeling. For the 5-axis machining humerus bone, the anatomical structures of the anatomic neck, greater tubercle, lesser tubercle, and intertubercular groove were similar to those in the three-dimensional medical image. In the future, the convergence machining technology, where 5-axis machining of various structures(e.g., the surgical neck undercut of the humerus bone) is performed as described above, can be efficiently applied to the manufacture of a customized joint that pursues the precise model of a human body.