Deterioration Analysis of the Shunting Locomotive Through Precision Diagnosis Assessment : Running Performance Assessment (입환기관차의 노후도 정밀진단 : 주행성능평가)

  • Pyun Jang-Sik;Chung Jong-Duk;Kim Jeong-Guk;Choi Kyung-Jin;Kim Won-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.557-562
    • /
    • 2004
  • The deterioration of a shunting locomotive was characterized for the lifetime assessment. The locomotive has been used for shunting works in steel making processes, and in this investigation, various types of technical evaluation methods for the locomotive parts were employed to assess the current deterioration status and to provide important clue for lifetime prediction. Unlike other rolling stocks in railway applications, the diesel shunting locomotive is composed of major components such as diesel engine, transmission, gear box, brake system, electronic devices, etc. In this paper, the analysis results of running performance assessment have been used to provide the critical information for the criteria of precision diagnosis assessment.

  • PDF

Deterioration Analysis of the Shunting Locomotive Through Precision Diagnosis Assessment : Diesel Engine & Power Transmission Parts (입환기관차의 노후도 정밀진단 : 엔진 및 동력전달장치)

  • Chung Jong-Duk;Kim Jeong-Guk;Hong Yong-Ki;Lee Dong-Hyung;Pyun Jang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.545-550
    • /
    • 2004
  • The deterioration of a shunting locomotive was characterized for the lifetime assessment. The locomotive has been used for shunting works in steel making processes, and in this investigation, various types of technical evaluation methods for the locomotive parts were employed to assess the current deterioration status and to provide important clue for lifetime prediction. Unlike other rolling stocks in railway applications, the diesel shunting locomotive is composed of major components such as diesel engine, transmission, gear box, brake system, electronic devices, etc. In this paper, the degree of deterioration in a diesel engine and power transmission parts has been presented based on the analysis results.

  • PDF

A study about an old age car performance characteristic (노후차량 성능 특성에 관한 연구)

  • Hong Yong-Ki;Kwon Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.332-337
    • /
    • 2005
  • In order to investigate performance changes, the acceleration, vibration, and braking performance tests were carried out on the electric multiple units (EMUs) with over 20 years operation. According to the testing results, in vibration and braking performance, the similar performance results were obtained as compared with newly manufactured EMUs. However, in terms of acceleration performance, below reference value (3.0 km/h/s) has been obtained. This is mainly due to performance deterioration including traction motor. The precision diagnosis evaluation of deteriorated EMUs will be provided through the overall evaluation of corrosion testing and structural performance of car body.

  • PDF

Precise Deterioration Diagnosis and Restoration Stone Suggestion of Jungdong and Banjukdong Stone Aquariums in Gongju, Korea (공주 중동 및 반죽동 석조의 정밀 손상도 진단과 복원석재 제안)

  • Jo, Young Hoon;Lee, Myeong Seong;Choi, Gi Eun;Lee, Chan Hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.3
    • /
    • pp.92-111
    • /
    • 2011
  • This study focus on the restoration stone selection of break-out part based on material characteristics analysis and the conservational safety diagnosis using various nondestructive techniques for Jungdong and Banjukdong Stone Auariums. As a result, the original rocks of the stone aquariums body are porphyritic granodiorite with magnetite-series having igneous lineation, microcline phenocryst, veinlet and basic xenolith. As a result of the provenance presumption of the host rock, a rock around Gamgokri area in Nonsan City was identified the genetically same rock. Therefore, the rock is appropriate for restoration materials of the break-out part. The deterioration assessment showed that the stone aquariums were highly serious scaling, scale off and blackening. Particularly, the front face of Banjukdong stone aquarium needs reinforcement of structural crack (760mm) caused from igneous lineation of biotite. Blackening contaminants on the stone aquariums surface occurred by combining iron oxide, manganese oxide and clay mineral. Also, major factors of efflorescence contaminants were identified as calcite (Jungdong stone aquariums) and gypsum (Banjukdong stone aquariums). The physical characteristics of stone aquariums appeared that the original and new stone is third (moderately weathered) and second grade (slightly weathered), respectively. This study sets up an integrated conservation system from material analysis to restoration stone selection and conservational safety diagnosis of Jungdong and Banjukdong stone aquariums.

A Measurement and Diagnosis for Resistive Leakage Current of ZnO Arrester Element (ZnO 피뢰기 소자의 저항분 누설전류 측정 및 분석)

  • Lee, Bok-Hee;Kang, Sung-Man;Park, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2155-2157
    • /
    • 1999
  • This paper describes a new measurement method of resistive current and the technique of deterioration diagnosis for ZnO element. The consequence of current increasing (resistive current) with time is the eventual attainment of a state of thermal instability that may lead to arrester failure. So, it is very important to measure a leakage current of ZnO arrester installed at on-state. For the high-precision and more reliability, an iron core, which has a very high relative permeability, was used for increasing detection sensitivity, and we also used the personal computer for the data storage and program and analysis. And we have verified the reliability and performance of the sensing device through several laboratory tests.

  • PDF

Analysis of the Causes of Accidents Related to 3 Phase 170 kV Gas Insulated Switchgears(GIS) and Preventive Measures (3상 170 kV 가스절연개폐장치(GIS)의 사고 원인 분석 및 예방 대책)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.41-46
    • /
    • 2011
  • The purpose of this paper is to analyze the causes of accidents related to the 3 phase 170 kV gas insulated switchgear of a power system collected from accident sites to secure data for the prevention of similar accidents and provide important points of view regarding diagnosis for the prevention of accidents involving gas insulated switchgears. The analysis results of the causes of accidents involving gas insulated switchgears showed deformation of the manipulation lever installed at the S-phase, disconnection of the insulation rod connection, melting of the upper conductor, a damaged tulip, damage to the lower spacer and the spacer at the breaker, etc. It is believed from this result that the potential for accidents has expanded due to accumulated energy as a result of repeated deterioration. The carbonization depth of a GIS was formed near the screw (T2, T3) used to secure the lower pole of the S-phase tulip. It is not known what has caused the screws to be extruded and melted. However, it is thought that an unbalanced electromagnetic force, micro-discharge, surface discharge, etc., have occurred at that point. In addition, even though 16 years have passed since its installation, there was no installation defect, act of arson, accidental fire, etc. General periodical inspection and diagnosis failed to find the factors causing the accidents. As a system contained in a closed metal container, it has a high risk factor. Therefore, it is necessary to design, install and operate a GIS in accordance with the standard operational procedure (SOP). In addition, it is necessary to apply conversion technology for periodical SF6 gas analysis and precision safety diagnosis. It is expected that tracking and managing these changes in characteristics by recording the results on the history card will provide a significant accident prevention effect.

An Analysis on the Actual Condition of Indoor Air Quality in Rural House (농촌지역 노후주택의 실내공기환경 실태분석 연구)

  • Park, Roun;Cho, Sukyeong;Kim, Sangbum
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • The ratio of the deterioration housing in rural area was 29.6%, but it was 18.3% in urban area based on a 2018 survey. In consideration of the point, this study aims to analyze the actual condition of indoor air quality in rural houses to provide basic data for improving the indoor air environment. It was investigated 15housings of Hongseong-gun, Chungchengnam-do. To investigate the correlation between indoor air quality and housing type, both the field survey of housing type and precision diagnosis of concentration of indoor air pollutants such as HCHO, TVOC, Fine dust(PM-10, PM-2.5), CO2, Radon. The results of this study are as follows. First, according to the average value of each element of rural old housing, the construction year was distributed in 1939~2004, and 12households(80%) living in houses older than 30years have passed for about 46years. As for the housing area, more than 12houses(80%) of 60㎡ or more and 3 houses (20%) of less than 60㎡ were often living in relatively small-scale housing. Second, as a result of measuring indoor air pollutants in rural houses, substances exceeding the standard values were found in HCHO, TVOC, CO2. Third, in the case of Fine dust and Radon, none of such factors were exceeded the standard. Fourth, there was no significant difference in indoor air quality depending on housing type in rural houses. This paper is expected to contribute to the regional development projects and effective implementation of rural policies.

Prediction of Crack Distribution for the Deck and Girder of Single-Span and Multi-Span PSC-I Bridges (단경간 및 다경간 PSC-I 교량의 바닥판 및 거더의 균열분포 예측)

  • Hyun-Jin Jung;Hyojoon An;Jaehwan Kim;Kitae Park;Jong-Han Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.102-110
    • /
    • 2023
  • PSC-I girder bridges constitute the largest proportion among highway bridges in Korea. According to the precision safety diagnosis data for the past 10 years, approximately 41.3% of the PSC-I bridges have been graded as C. Furthermore, with the increase in the aging of bridges, preemptive management is becoming more important. Damage and deterioration to the deck and girder with a long replacement cylce can have considerable impacts on the service and deterioration of a bridge. In addition, the high rate of device damages, including expansion joints and bearings, necessitates an investigation into the influence of the device damage in the structural members of the bridge. Therefore, this study defined representative PSC-I girder bridges with single and multiple spans to evaluate heterogeneous damages that incorporate the damage of the bridge member and device with the deterioration of the deck. The heterogeneous damages increased a crack area ratio compared to the individual single damage. For the single-span bridge, the occurrence of bearing damage leads to the spread of crack distribution in the girder, and in the case of multi-span bridges, expansion joint damage leads to the spread of crack distribution in the deck. The research underscores that bridge devices, when damaged, can cause subsequent secondary damage due to improper repair and replacement, which emphasizes the need for continuous observation and responsive action to the damages of the main devices.

A Review of the Deterioration and Damage of the Top Flange of the Highway PSC Box Girder Bridge based on the Condition Assessment Results (상태평가 결과 기반 고속도로 PSC Box 거더교 상부플랜지 열화·손상 실태 고찰)

  • Ku, Young-Ho;Han, Sang-Mook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.23-32
    • /
    • 2022
  • Although PSCB girder bridges account for 4% of the bridges in use on highways, they do not account for much, but 98% of PSCB girder bridges are 1st type and 2nd type of bridge. Also, the total length of the PSCB girder bridge is 16% (192km) of the total length of the highway bridge. Thus, the PSCB girder bridge can be one of the bridge types where maintenance is important. In order to analyze the damage types of PSCB girder bridges, a detailed analysis was conducted by selecting 62 places (477 spans) precision safety diagnosis reports considering ratio of the construction method and snow removal environment exposure class. Analysis of report and a field investigation was conducted, and as a result, most of the causes of deterioration damage were caused by rainwater (salt water) flowing into the bridge pavement soaking in between the top flange and the interface. After concrete slab deteriorate occurred then bridge pavement cracking and breaking increased and exfoliation of concrete occurred by corrosion and expansion of the reinforcing bars occurred. In addition, the cause of cracks in the longitudinal direction on the bottom of the top flange is considered to be cracks caused by restrained drying shrinkage. In conclusion, for reasonable maintenance considering the characteristics of PSCB girder bridges, it should be suggested in the design aspect that restrained drying shrinkage crack on top flange. Also, it is believed that differentiated maintenance method should be proposed according to snow removal environment exposure class.