• 제목/요약/키워드: Precise measurement

검색결과 1,032건 처리시간 0.022초

Efficient Signature-Driven Self-Test for Differential Mixed-Signal Circuits

  • Kim, Byoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.713-718
    • /
    • 2016
  • Predicting precise specifications of differential mixed-signal circuits is a difficult problem, because analytically derived correlation between process variations and conventional specifications exhibits the limited prediction accuracy due to the phase unbalance, for most self-tests. This paper proposes an efficient prediction technique to provide accurate specifications of differential mixed-signal circuits in a system-on-chip (SoC) based on a nonlinear statistical nonlinear regression technique. A spectrally pure sinusoidal signal is applied to a differential DUT, and its output is fed into another differential DUT through a weighting circuitry in the loopback configuration. The weighting circuitry, which is employed from the previous work [3], efficiently produces different weights on the harmonics of the loopback responses, i.e., the signatures. The correlation models, which map the signatures to the conventional specifications, are built based on the statistical nonlinear regression technique, in order to predict accurate nonlinearities of individual DUTs. In production testing, once the efficient signatures are measured, and plugged into the obtained correlation models, the harmonic coefficients of DUTs are readily identified. This work provides a practical test solution to overcome the serious test issue of differential mixed-signal circuits; the low accuracy of analytically derived model is much lower by the errors from the unbalance. Hardware measurement results showed less than 1.0 dB of the prediction error, validating that this approach can be used as production test.

대형 접시형 안테나 추적성능 검증에 관한 연구 (A Study on the Validation of Tracking Performance of a Big Parabola Antenna System)

  • 오창열;오승엽
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.77-82
    • /
    • 2010
  • 무선주파수를 사용하는 추적안테나의 추적성능은 비행체 추적 및 위치 측정에서 매우 중요한 요소이나, 전기적 물리적으로 매우 큰 안테나의 특성을 정확히 측정하는 것은 쉽지 않다. 특히 우주응용분야에서 사용되는 대형 접시형 추적안테나 시스템과 같이 신호원을 따라 안테나의 지향방향이 변하는 경우에는 안테나 지향방향에 따라 특성이 일정하지 않을 수 있다. 본 논문에서는 대형 추적안테나 시스템의 추적 성능지표인 지향정확도 및 추적정확도에 영향을 주는 오차요인을 검토하고, 나로우주센터에서 원격측정용으로 사용하고 있는 11m 대형 접시형 추적안테나에 대한 추적성능을 효율적으로 측정할 수 있는 저궤도위성(Low Earth Orbit)을 사용한 측정방법 및 그 결과를 기술한다.

하악상행지 시상분할골절단술 시 하악후퇴량의 방사선학적 예측 (Prediction of Amount of Mandibular Set Back with 3 Plain Radiographs in Mandibular Sagittal Split Ramus Osteotomy)

  • 노량석;김진욱;권대근;이상한
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권4호
    • /
    • pp.323-330
    • /
    • 2011
  • Purpose: The present study examined the reproducibility of an operation plan by comparing the jaw position of STO with the postoperative mandibular set back measurement in sagittal split ramus osteotomy. Methods: Thirty patients with class III dental and skeletal malocclusion and who were treated with BSSRO were reviewed. Three plain radiographs such as the panoramic view, the lateral cephalogram and the submentovertex view were taken before and after operation. Also, paper surgery for STO and model surgery were used to evaluate the amount of mandibular set back. Results: On the panoramic view, the amount of mandibular set back in STO was similar to the postoperative results of model surgery, but the amount of mandibular set back on the lateral cephalogram was smaller than the postoperative result of model surgery and then the amount of set back on submentovertex view was similar to the postoperative result of model surgery. Conclusion: Precise tracing and paper surgery should be performed for a combined expected STO in order to predict the exact amount of preoperative mandibular set back.

HepG2 세포에서 용매에 의한 차별적인 사람 싸이토크롬 P450 2E1활성 변화 (Differential Role of Solvents on Human Cytochrome P450 2El Activity in Intact HepG2 Cells)

  • 최달웅
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.9-15
    • /
    • 2003
  • The modification of CYP2El activity is a matter of considerable interest because of its role in the metabolic activation of a variety of environmental toxicants. In the present study, the time-course of changes in human CYP2El activities was determined following treatment with solvents (acetone, dimethylsulphoxide or pyridine) using intact HepG2 cells transfected by human CYP2El. Hydroxylation of chlorzoxazone was used for the measurement of CYP2El activity. CYP2E1 protein level was increased upon cultivation of cells in the presence of the solvents for 24 hr. Determination of CYP2El activities after 24 ht cultivation with the solvents demonstrated that acetone or dimethylsulphoxide increased, whereas pyridine inhibited the activities. This differential effect of the solvents on CYP2El activities persisted to subsequent 24 ht. Competitive inhibition study suggested that pyridine has stronger binding affinity to CYP2E1 than acetone or dimethylsulphoxide. These results demonstrate that different binding affinity of the solvents to CYP2El plays important role in determining real CYP2El activity in intact cells after exposure to the solvents. Present study would be helpful in precise understanding of human CYP2El-mediated toxicity.

Critical Design Status of the G-CLEF Flexure Control Camera

  • Oh, Jae Sok;Park, Chan;Kim, Kang-Min;Chun, Moo-Young;Yu, Young Sam;Lee, Sungho;Kim, Jihun;Szentgyorgyi, Andrew;Podgorski, William;Evans, Ian;Mueller, Mark;Uomoto, Alan;Crane, Jeffrey;Hare, Tyson
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.56.4-57
    • /
    • 2017
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the very first light instrument of the Giant Magellan Telescope (GMT) to be commissioned in 2022. The instrument is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. Korea Astronomy and Space Science Institute (KASI) has been involved in the development of the G-CLEF as one member of the international consortium consisted of five astronomical institutes including Smithsonian Astrophysical Observatory (SAO), Observatories of the Carnegie Institution of Washington (OCIW). It is scheduled to have KASI side Critical Design Review in December 2017. In this presentation we will report the recent progress on the critical design activities for the G-CLEF Flexure Control Camera (FCC).

  • PDF

Different Real Time PCR Approaches for the Fine Quantification of SNP's Alleles in DNA Pools: Assays Development, Characterization and Pre-validation

  • Mattarucchi, Elia;Marsoni, Milena;Binelli, Giorgio;Passi, Alberto;Lo Curto, Francesco;Pasquali, Francesco;Porta, Giovanni
    • BMB Reports
    • /
    • 제38권5호
    • /
    • pp.555-562
    • /
    • 2005
  • Single nucleotide polymorphisms (SNPs) are becoming the most common type of markers used in genetic analysis. In the present report a SNP has been chosen to test the applicability of Real Time PCR to discriminate and quantify SNPs alleles on DNA pools. Amplification Refractory Mutation System (ARMS) and Mismatch Amplification Mutation Assay (MAMA) has been applied. Each assay has been pre-validated testing specificity and performances (linearity, PCR efficiency, interference limit, limit of detection, limit of quantification, precision and accuracy). Both the approaches achieve a precise and accurate estimation of the allele frequencies on pooled DNA samples in the range from 5% to 95% and don't require standard curves or calibrators. The lowest measurement that could be significantly distinguished from the background noise has been determined around the 1% for both the approaches, allowing to extend the range of quantifications from 1% to 99%. Furthermore applicability of Real Time PCR assays for general diagnostic purposes is discussed.

다공질 정압공기 베어링을 이용한 직진 테이블에 있어 주위환경이 움직임 정밀.정확도에 미치는 영향 (Influence of the environments on the movement precision of the guide table using externally pressurized porous air bearing)

  • 한응교;허석환;노병옥
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.721-729
    • /
    • 1988
  • 본 연구에서는 직진테이블 시작품을 통해 주위환경에 의한 영향 중 주위온도 에 따른 움직임 정밀 정확도의 변화 및 지지조건이 움직임 정밀.정확도에 미치는 영향 에 대해 실험 연구하였다.

Linear Motor의 열변형 오차해석 및 실험 (Thermal Deformation Error Analysis and Experiment of a Linear Motor)

  • 최우혁;민경석;오준모;최우천;홍대희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.286-289
    • /
    • 1997
  • In the design of structure the forces acting on the structure are important parameter for noise and vibration control. However, in the complex structure, the forces at the injection pomt on the structure cannot be measured directly. Thus it is necessary to find out indirect force evaluation method. In thls paper forces have been measured with in-situ vibration responses and system information. Three existing techniques of indirect force measurement, viz. direct inverse, principal component analysis and regularization have been compared. It has been shown that multi-vibration responses are essential for the precise estimation of the forces. To satisfy those cond~tions, Rotary compressor is adopted as test sample, because it is very difficult to measurc the injection forces from internal excitat~on to shell. It has also been obtained that relatively higher force IS transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation wlth curvature shell and plate and is investigated the possibility of force evaluation of rotary compressor as a complex structure.

  • PDF

PET/CT 영상 움직임 보정 (Motion Correction in PET/CT Images)

  • 우상근;천기정
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.172-180
    • /
    • 2008
  • PET/CT fused image with anatomical and functional information have improved medical diagnosis and interpretation. This fusion has resulted in more precise localization and characterization of sites of radio-tracer uptake. However, a motion during whole-body imaging has been recognized as a source of image quality degradation and reduced the quantitative accuracy of PET/CT study. The respiratory motion problem is more challenging in combined PET/CT imaging. In combined PET/CT, CT is used to localize tumors and to correct for attenuation in the PET images. An accurate spatial registration of PET and CT image sets is a prerequisite for accurate diagnosis and SUV measurement. Correcting for the spatial mismatch caused by motion represents a particular challenge for the requisite registration accuracy as a result of differences in PET/CT image. This paper provides a brief summary of the materials and methods involved in multiple investigations of the correction for respiratory motion in PET/CT imaging, with the goal of improving image quality and quantitative accuracy.

시변 상보필터와 보행상태 추정을 이용한 경골의 기울어짐 각도추정 (Estimation of Tibia Angle through Time-Varying Complementary Filtering and Gait Phase Detection)

  • 송석기;우한승;공경철
    • 제어로봇시스템학회논문지
    • /
    • 제21권10호
    • /
    • pp.944-950
    • /
    • 2015
  • Recent studies on ankle-foot prostheses used for transtibial amputees have focused on the adaptation of the ankle angle of the prosthesis according to ground conditions. For adaptation to various ground conditions (e.g., incline, decline, and step conditions), ankle-foot prostheses should first recognize the ground conditions as well as the current human motion pattern. For this purpose, the ground reaction forces and orientation angle of the tibia provide fundamental information. The measurement of the orientation angle, however, creates a challenge in practice. Although various sensors, such as accelerometers and gyroscopes, can be utilized to measure the orientation angles of the prosthesis, none of these sensors can be solely used due to their intrinsic drawbacks. In this paper, a time-varying complementary filtering (TVCF) method is proposed to incorporate the measurements from an accelerometer and a gyroscope to obtain a precise orientation angle. The cut-off frequency of TVCF is adaptively determined according to the human gait phase detected by a fuzzy logic algorithm. The performance of the proposed method is verified through experiments.