• Title/Summary/Keyword: Precise measurement

검색결과 1,016건 처리시간 0.045초

A Precise Heave Determination System Using Time-Differenced GNSS Carrier Phase Measurements

  • Cho, MinGyou;Kang, In-Suk;Park, Chansik
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제6권4호
    • /
    • pp.149-157
    • /
    • 2017
  • In this study, a system that precisely determines the heave of ship hull was designed using time-differenced GNSS carrier phase measurement, and the performance was examined. First, a technique that calculates precise position relative to the original position based on TDCP measurement for point positioning using only one receiver was implemented. Second, to eliminate the long-cycle drift error occurring due to the measurement error that has not been completely removed by time-differencing, an easily implementable high-pass filter was designed, and the optimum coefficient was determined through an experiment. In a static experiment based on the precise heave measurement system implemented using low-cost commercial GNSS receiver and PC, the heave could be measured with a precision of 2 cm standard deviation. In addition, in a dynamic experiment where it moved up and down with an amplitude of 48 cm and a cycle of 20 seconds, precise heave without drift error could be determined. The system proposed in this study can be easily used for many applications, such as the altitude correction of fish detection radar.

DFT를 이용한 계통연계 인버터 시스템의 고정밀 계측 (High Precise Measurement of Grid-Connected Inverter using DFT)

  • 이상혁;강필순;이상훈;조수억;이태원;박성준
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.93-98
    • /
    • 2012
  • A precise measurement of the grid voltage is one of the essential techniques, which is required to connect a renewable energy to the grid. In general, when a filter is used to eliminate unnecessary harmonics and noises, a signal is distorted by phase delay, amplitude attenuation, and other distortions. And the response characteristic of a controller is directly affected by bandwidth of cut-off frequency of the filter. To alleviate this problems, we propose an effective algorithm based on DFT(Discrete Fourier Transform) instead of approaching the filter application. The proposed algorithm ensures high precise measurement of the grid voltage because it can extract the fundamental and harmonics from the raw signal without any distortions. The high performance of the proposed algorithm is verified by PSIM simulation and experiments of Grid-Connected VSI.

로보틱 토노메트리 센서를 이용한 요골 동맥 파형 정밀 측정 방법 (Precise Measurement Method of Radial Artery Pulse Waveform using Robotic Applanation Tonometry Sensor)

  • 김영민
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.135-140
    • /
    • 2017
  • In this paper, a novel measurement method of radial artery pulse waveform using robotic applanation tonometry (RAT) was present to reduce the errors by the pressing direction of the vessel. The RAT consisted of an array of pressure sensors and 2-axis tilt sensor, which was attached to the universal joint with a linear spring and five-DOF robotic manipulator with a one-axis force sensor. Using the RAT mechanism, the pulse sensor could be manipulated to perpendicularly pressurize the radial artery. A pilot experimental result showed that the proposed mechanism could find the optimal pressurization angles of the pulse sensor within ${\pm}3^{\circ}$standard deviations. Coefficient values of variation of maximum pulse peaks extracted from the pulse waveforms were 4.692, 6.994, and 11.039 % for three channels with the highest magnitudes. It is expected that the proposed method can be helpful to develop more precise tonometry system measuring the pulse waveform on the radial artery.

영상처리기술을 이용한 구조물의 변위 측정 시스템의 개발 (Development of Displacement Measurement System of Structures Using Image Processing Techniques)

  • 김성욱;김상봉;서진호
    • 제어로봇시스템학회논문지
    • /
    • 제10권8호
    • /
    • pp.673-679
    • /
    • 2004
  • In this paper, we develop the displacement measurement system of multiple moving objects based on image processing techniques. The image processing method adopts inertia moment theory for obtaining the centroid measurement of the targets and basic processing algorithm of gray, binary, closing, labeling and so on. To get precise displacement measurement in spite of multiple moving targets, a CGD camera with zoom is used and the position of camera is changed by a pan/tilt system. The fiducial marks on the fixed positions are used as the sensing points for the image processing to recognize the position errors in direction of XY-coordinates. The precise alignment device is pan/tilt of XY-type and the pan/tilt is controlled by DC servomotors which are driven by a microprocessor. Morover, the centers of fiducial marks are obtainted by an inertia moment method. By applying the developed precise position control system for multiple targets, the displacement of multiple moving targets are detected automatically and are also stored in the database system in a real time. By using database system and internet, the displacement datum can be confirmed at a great distance and analyzed. Finally, the effectiveness of developed system is shown in experimental results and realized the precision about 0.12[mm] in the position control of XY-coordinates.

Development of a Combined GPS/GLONASS PPP Method

  • Choi, Byung-Kyu;Roh, Kyoung-Min;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제3권1호
    • /
    • pp.31-36
    • /
    • 2014
  • Precise Point Positioning (PPP) is a stand-alone precise positioning approach. As the quality of satellite orbit and clock products from analysis centers has been improved, PPP can provide more precise positioning accuracy and reliability. A combined use of Global Positioning System (GPS) and Global Orbiting Navigation Satellite System (GLONASS) in PPP is now available. In this paper, we explained about an approach for combined GPS and GLONASS PPP measurement processing, and validated the performance through the comparison with GPS-only PPP results. We also used the measurement obtained from the GRAS reference station for the performance validation. As a result, we found that the combined GPS/GLONASS PPP can yield a more precise positioning than the GPS-only PPP.

정밀측정을 위한 최적영상에 관한 연구 (A Study on the Optimal Image for Precise measurement)

  • 유봉환
    • 한국생산제조학회지
    • /
    • 제7권3호
    • /
    • pp.126-131
    • /
    • 1998
  • In computer vision system of modern industry precise measuring has lots of dfficulties because of measurement error due to distortion phenomenon. Among the difficulties, the distortion of edge is regraded as a dominent problem. which is caused by the vlurred image. The blurred image apperar when camera can not discriminate its precise focus. So. it is very important to decide focus of lens and to develop algorithm in order to correct distortion phenomenon. Thus. discrimination criteria obtained by image information of precise focus must be fixed in advance. The gray level histogram of image acquired from blurred edge tends to show a uniform distribution. Bimodal intensity histogram is related with condition of focus, and it is possible to find good condition of focus by using bimodal histogram of entropy.

Expected RGDOP Based Satellite Selection Scheme for Performance Improvement of Precise Float Solution

  • Lee, Sunyong;Lim, Deok Won;Noh, Jae Hee;Lee, Jin Hyuk;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제7권4호
    • /
    • pp.255-265
    • /
    • 2018
  • In this paper, the positioning performance index is proposed. The proposed index is used to find satellites that degrade positioning performance to improve the positioning performance. To do this, the proposed index is calculated using the code measurement quality and the DOP. And, through the experiment, the effectiveness of the proposed index is confirmed. In the experiment, the quality of the code measurements is analyzed, and the effectiveness of the proposed index is confirmed by comparing with the result of the precise float solution. Finally, it is shown that the precise float solution performance is improved by using the proposed index.

손실각 표준기 전극의 진직, 진원도 측정시스템 개발 (Development of Straightness, Roundness Measurement System for Standard Electrode of Loss Angle)

  • 장종훈
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 추계학술대회 논문집
    • /
    • pp.198-203
    • /
    • 1998
  • To acquire the high precision of profile for standard electrode of loss angle, it is needed ultraprecision machining technology like MEAP(Magnetic Electronic Abrasive Polishing) and the very high profile measurement technology which can measure a micro unit about the workpiece. So, in this paper, it was developed the measurement system of precision of profile using non-contactable sensor that was approximate sensor of capacitance type, because that is better than others in the electrical characteristics. And standard electrode of loss angle was machined by the MEAP machining technology. In this study, it was development of precision measurement system. This system could be used measure the workpiece of roundness and straightness much more precise and faster than general mechanical measurement system done before. And it could be helped to minimize machining time and planning by very fast and precise measurement about the workpiece.

  • PDF

LVDT를 이용한 범용 외경측정 모듈에 관한 연구 (A Study on the Universal Outer Diameter Measurement Module using LVDT)

  • 이능구;곽이구;김홍건
    • 한국기계가공학회지
    • /
    • 제16권3호
    • /
    • pp.100-106
    • /
    • 2017
  • A universal outer diameter measurement module was developed using a linear variable differential transformer (LVDT). This outer diameter measurement module enables simultaneous measurement of outer diameter, displacement, and perpendicularity of bench-type high-precision products by combining analogue and digital measurement principles with mechanically precise and fine adjustment functions. The developed module showed a performance of 0.001mm in measurement resolution, 0.001mm in measurement accuracy, reference surface abrasion lower than Ra 0.1864, and measurement stability of 0.002mm. Therefore, we have acquired domestic measurement technology to improve productivity by securing technical competitiveness for universal diameter measurement technology, lower production costs through import substitution, and increased quality of products with more precise measurement technology. Furthermore, a substitution effect is expected for expensive import measurement system equipment used in production, research, and inspection sites in industries that produce precision processing products such as automobile and machine components.

교량 무가조립을 위한 산업사진측량 기법 (Industrial Photogrammetry Method for Precise Measurement of The Steel Box Girder)

  • 정성혁;박경식;최석근;이재기
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 추계학술발표회 논문집
    • /
    • pp.189-195
    • /
    • 2004
  • The purpose of this study was to establish the accuracy of the industral photogrammetry system constructed with INCA2 metric camera and V-STARS system on steel box girder measurement under industrial measurement condition. The objective of the measurement was to determine the distances of plane to plane or plane to libs, precise positions of the bolt holes and angles of the plane to plane on the steel box girder using coded targets, tape targets, edge targets and target adapters. The measurement undertaken has shown that industrial photogrammetry method were a very accurate and more importantly were produced quietly to measure the steel box girder.

  • PDF