• Title/Summary/Keyword: Precipitation Efficiency

Search Result 407, Processing Time 0.025 seconds

Evaluation of analytical method for polybrominated diphenyl ethers (PBDEs) in manufactured products waste (제품폐기물 중 폴리브롬화에테르류 (PBDEs) 분석방법 비교 연구)

  • Shin, Sun Kyoung;Kim, Hyoung Seop;Jeon, Tae Wan;Kim, Tae Seung;Kim, Jong Ha;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.109-114
    • /
    • 2007
  • In this study, soxhlet extraction and dissolution-precipitation method are used for separating analyte from polymer materials. In soxhlet extraction efficiency test, it has been found that the DCM, Toluene, THF, and mixtures Acetone/Hexane (1:4, v/v) gave good extraction efficiency, while the use of the ethyl ether, acetone/ethyl ether (1:4, v/v), acetone/hexane (1:1, v/v), DCM/hexane (1:1, v/v) resulted in significantly lower values. In case of dissolution-precipitation method, there is no considerable difference with used different dissolving solvent. The elution amount of multi layer silica and Florisil column were determined with hexane 250 mL and 70 mL of hexane, respectively. Range of PBDE in real waste plastics was N.D.~1,028 ppm.

Electrokinetic Extraction of Heavy Metal from Clayey Soil : Desorption Characteristics During Electrical Treatment (중금속으로 오염된 점성토에서 동전기프로세스에 의한 탈착 특성)

  • Lee, Myung-Ho;Jang, Yeon-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.3
    • /
    • pp.23-28
    • /
    • 2007
  • A number of batch isotherm and electrokinetic experiments were conducted in order to investigate the migration of zinc and its removal efficiency during electrokinetic soil processing. Sorption and desorption characteristics of zinc spiked kaolin clay have been examined by comparison with electrically induced desorption and precipitation occurring in the anode and cathode regions, respectively. The removal efficiency of zinc under the applied voltage gradient of 300 V/m was found to be up to approximately 80 % within 4 hours of the electrokinetic treatment. The study is significant with respect to the remediation of contaminated areas.

A Compact Pulse Corona Plasma System with Photocatalyst for an Air Conditioner (광촉매와 조합된 코로나 방전 플라즈마 필터의 유해 가스 및 입자 제거 특성)

  • Shin, Soo-Youn;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.151-155
    • /
    • 2007
  • A compact discharge plasma system with a photocatalyst has been proposed and investigated experimentally for application to air conditioners. It was found that there was intense ultra violet radiation with high energy of 3.2 eV from the corona discharge due to the DC-biased pulse voltage applied on a wire. An electrophotochemical reaction took place apparently on the surfaces of the photocatalyst of $TiO_2$ irradiated ultra violet front the discharge plasma in the proposed plasma system. The proposed discharge plasma system with the photocatalyst of $TiO_2$ showed very high removal efficiency of VOCs by tile additional electrophotochemical reactions on the photocatalyst. The proposed discharge plasma system also showed very high removal efficiency of particles such as smokes, suspended bacteria, and pollen and mite allergens by the electrostatic precipitation part. This type of corona discharge plasma system with a photocatalyst can be used as an effective means of removing both indoor pollutant gases and particles including suspended allergens.

Nano Particle Precipitation and Residual Ozone Decomposition of a Hybrid Air Cleaning System Comprising Dielectric Barrier Discharge Plasma and MnO2 Catalyst or Activated Carbon (활성탄 또는 촉매가 장착된 배리어 유전체 방전 하이브리드. 공기청정 시스템의 나노입자 및 잔류 오존 제거 특성)

  • Byeon, Jeong-Hoon;Hwang, Jung-Ho;Ji, Jun-Ho;Kang, Suk-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.524-533
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Aim of this work is to determine design and operating parameters of a hybrid air cleaning system. DBD and ESP(Electrostatic Precipitator) are used as nano particle charger and collector, respectively. Pelletized MnO$_2$ catalyst or activated carbon is used fer ozone decomposition or adsorption material. AC voltage of 7~10 KV(rms) and 60 Hz is used as DBD plasma source. DC - 8 KV is applied to the ESP for particle collection. The overall particle collection efficiency for the hybrid system is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized MnO$_2$ catalyst or activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.

Firm's Economic Efficiency and Critical Weather Information in Distribution Industry by Climate Change (기후변화에 따른 유통산업의 핵심 기상요인과 기업의 경제적 효율성)

  • Lee, Joong-Woo;Ko, Kwang-Kun;Jeon, Jin-Hwan
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.787-797
    • /
    • 2010
  • Nowadays meteorological information is systemized as a useful knowledge which has a significant effect on the overall industrial domains over the simple data. The distribution industry, which has the short life cycle, depends on the meteorological information at the strategic level. However, it is necessary to pay attention to the continuous investment in meteorological information because there is a hostility to paying for a service, particularly it does not provide accurate and reliable information. Therefore, the purpose of this study is to increase the usefulness of meteorological information in the distribution industry for its economic effectiveness from the core meteorological factors. We found significant meteorological factors (temperature, precipitation, disaster) that have a critical influence on the distribution industry through the hierarchical analysis process, and their importance according to the type of distribution channels, such as department store, large-scale discount store, convenience store, and home shopping. We performed the AHP analysis with 103 survey samples by middle managers from the various distribution channels. We found that precipitation is the critical meteorological factor across the distribution industry. Based on this result, we stress the difference in the level of the meteorological information in order for the effectiveness of each type of distribution channels.

Treatment of Dye-Processing Wastewater with Complex Chemical Coagulants (복합응집제를 이용한 염색가공 폐수의 처리)

  • Seo, Myung-Po;Kim, Byung-So
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.111-116
    • /
    • 2006
  • This study provides the optimal conditions treating with the coagulation process and the other chemical treatment processes for dyeing wastewater, especially various dyeing complex wastewater. The results are shown as follows: 1. Optimum reaction condition of pH for ferrous sulfate was the range of 9 to 12. And when 3,000ppm(mg/l) of ferrous sulfate was dosed, the maximum $COD_{Mn}$ removal rate was approximately 40%. 2. In case of ferrous chloride and Bittern as coagulants, optimum pH range was 10 to 11. And maximum $COD_{Mn}$ removal rate was approximately 46% to 50% for dose of 2,000ppm(mg/l) to 6,000 ppm. 3. It is confirmed that the activated sludge process following coagulation precipitation method provides better treatment efficiency than the coagulation precipitation method following the activated sludge process. 4. The purpose of this study was to produce CGF (Cyanoguanidineformaldehyde resin) by organic compounds. 5. The complex coagulation agent by this study is the most economical coagulant with Alum(aluminum sulfate) and the removal efficiency is approximately 54% with 1,000ppm(mg/l) of pH range 6 to 7.

  • PDF

Application of Artificial Neural Network to Improve Quantitative Precipitation Forecasts of Meso-scale Numerical Weather Prediction (중규모수치예보자료의 정량적 강수추정량 개선을 위한 인공신경망기법)

  • Kang, Boo-Sik;Lee, Bong-Ki
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.2
    • /
    • pp.97-107
    • /
    • 2011
  • For the purpose of enhancing usability of NWP (Numerical Weather Prediction), the quantitative precipitation prediction scheme was suggested. In this research, precipitation by leading time was predicted using 3-hour rainfall accumulation by meso-scale numerical weather model and AWS (Automatic Weather Station), precipitation water and relative humidity observed by atmospheric sounding station, probability of rainfall occurrence by leading time in June and July, 2001 and August, 2002. Considering the nonlinear process of ranfall producing mechanism, the ANN (Artificial Neural Network) that is useful in nonlinear fitting between rainfall and the other atmospheric variables. The feedforward multi-layer perceptron was used for neural network structure, and the nonlinear bipolaractivation function was used for neural network training for converting negative rainfall into no rain value. The ANN simulated rainfall was validated by leading time using Nash-Sutcliffe Coefficient of Efficiency (COE) and Coefficient of Correlation (CORR). As a result, the 3 hour rainfall accumulation basis shows that the COE of the areal mean of the Korean peninsula was improved from -0.04 to 0.31 for the 12 hr leading time, -0.04 to 0.38 for the 24 hr leading time, -0.03 to 0.33 for the 36 hr leading time, and -0.05 to 0.27 for the 48 hr leading time.

Comparison and Analysis of Drought Index based on MODIS Satellite Images and ASOS Data for Gyeonggi-Do (경기도 지역에 대한 MODIS 위성영상 및 지점자료기반 가뭄지수의 비교·분석)

  • Yu-Jin, KANG;Hung-Soo, KIM;Dong-Hyun, KIM;Won-Joon, WANG;Han-Eul, LEE;Min-Ho, SEO;Yun-Jae, CHOUNG
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.4
    • /
    • pp.1-18
    • /
    • 2022
  • Currently, the Korea Meteorological Administration evaluates the meteorological drought by region using SPI6(standardized precipitation index 6), which is a 6-month cumulative precipitation standard. However, SPI is an index calculated only in consideration of precipitation at 69 weather stations, and the drought phenomenon that appears for complex reasons cannot be accurately determined. Therefore, the purpose of this study is to calculate and compare SPI considering only precipitation and SDCI (Scaled Drought Condition Index) considering precipitation, vegetation index, and temperature in Gyeonggi. In addition, the advantages and disadvantages of the station data-based drought index and the satellite image-based drought index were identified by using results calculated through the comparison of SPI and SDCI. MODIS(MODerate resolution Imaging Spectroradiometer) satellite image data, ASOS(Automated Synoptic Observing System) data, and kriging were used to calculate SDCI. For the duration of precipitation, SDCI1, SDCI3, and SDCI6 were calculated by applying 1-month, 3-month, and 6-month respectively to the 8 points in 2014. As a result of calculating the SDCI, unlike the SPI, drought patterns began to appear about 2-month ago, and drought by city and county in Gyeonggi was well revealed. Through this, it was found that the combination of satellite image data and station data increased efficiency in the pattern of drought index change, and increased the possibility of drought prediction in wet areas along with existing dry areas.

Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater (중금속폐수에서 구리의 전기화학적 침전처리)

  • 김재우;이재동;이우식;지은상
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

Studies on the Fractional Precipitation of Dextran by Nonsolvent Addition Method (비용매 첨가법을 이용한 Dextran 분별침전에 관한 연구)

  • 최성우;구윤모
    • KSBB Journal
    • /
    • v.10 no.3
    • /
    • pp.257-263
    • /
    • 1995
  • Fractional precipitation of "native" dextran by the method of nonsolvent addition was studied. Precipitational phenomenon of fractioned dextran was characterized with the quantitative determination of the precipitational capacity of nonsolvents with different dielectric constants. Based upon this characterization, the fractional precipitation process for the dextran production was developed. From the precipitational characteristics, a first-order relationship between the molecular weight of fractioned dextran and the content of nonsolvents was formulated. The slopes of the first-order equation were correlated with the dielectric constants of the nonslovents. A modified fractionation process was constructed on the basis of refractionation method and employed to increase the efficiency of the controlled production of dextran.

  • PDF