• Title/Summary/Keyword: Pre-Conditioning

Search Result 131, Processing Time 0.048 seconds

An Experimental Study on the Benefit of Pre-ventilation Using Solar Sunroof (쏠라 썬루프를 이용한 주차환기 시스템의 효과에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.6
    • /
    • pp.89-95
    • /
    • 2014
  • This study presented the benefit of the pre-ventilation using solar sunroof with integrated photovoltaic. Recent year, auto-makers make an effort to enhance the fuel efficiency and moreover to clean the cabin passenger's health. Solar energy, one of the alternative energies, adapted in automotive air handling system, in order to pre-ventilation when vehicle parked under the sun in summer. The power generated by a prototype solar sunroof has been used to run blower in a air handing system. And the solar sunroof was installed in a vehicle, and evaluated to find out benefit of the pre-ventilation. The effect of reducing the cabin temperature about $3^{\circ}C{\sim}10^{\circ}C$ with 20 ~ 40W power generator from solar sunroof were obtained in the pre-ventilation test. This reduced thermal load can lead to the reduction of air-conditioning operation time than that of current car. Moreover, fuel economy may increase as a results of the short use of the air-conditioning time. Additionally, Total Volatile Organic Compounds in the cabin is reduced maximum 80% than that of the current vehicle.

Numerical Analysis of Axial-Flow Cyclone Separator for Subway Station HVAC System Pre-Filter

  • Kim, Myung-Joon;Kim, Ho-Joong;Kwon, Soon-Bark;Kim, Se-Young;Kim, Jin-Kwan;Shin, Chang-Hun;Bae, Sung-Joon;Hwang, Sun-Ho;Kim, Tae-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.3
    • /
    • pp.94-99
    • /
    • 2009
  • In the Korean subway station, three types of pre-filters, which include auto filter, electrostatic precipitator (ESP) and auto cleaning demister, are widely used. However, these devices have some problems such as the difficulty of maintenance and high operating cost. In this study, axial-flow cyclone separator was employed as a pre-filter inside a heating, ventilation, and air conditioning (HVAC) system. 3-dimensional computational fluid dynamics (CFD) analysis was performed on a single unit axial-flow cyclone and coupled unit axial-flow cyclone. Calculated and measured pressure drop of the designed axial-flow cyclone were found be comparable to other types of pre-filters and the observed cut-off diameter was less than 10 micron. Considering lower operating and maintenance cost, axial-flow cyclone was proved to be a better solution as a pre-filter.

초고층 건물에서의 설비 조립화 공법 사례

  • 이정광
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.2
    • /
    • pp.25-32
    • /
    • 2001
  • 각종 설비 조립화 공법에 대하여 소개하고 특히 초고층건물에서의 P.F.P(pre fabricated piping)공법의 현장적용사례를 소개하고자 한다.

  • PDF

Developing Optimal Pre-Cooling Model Based on Statistical Analysis of BEMS Data in Air Handling Unit (BEMS 데이터의 통계적 분석에 기반한 공조기 최적 예냉운전 모델 개발)

  • Choi, Sun-Kyu;Kwak, Ro-Yeul;Goo, Sang-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.467-473
    • /
    • 2014
  • Since the operating conditions of HVAC systems are different from those for which they are designed, on-going commissioning is required to optimize the energy consumed and the environment in the building. This study presents a methodology to analyze operational data and its applications. A predicted operation model is to be produced through a statistical data analysis using multiple regressions in SPSS. In this model, the dependent variable is the pre-cooling time, and the independent variables include the power output of the supply air inverter during pre-cooling, the supply air set temperature during pre-cooling, the indoor temperature-indoor set temperature just before pre-cooling, supply heat capacity, and the lowest outdoor air temperature during non-cooling/non-heating hours. The correlation coefficient R2 of the multiple regression model between the pre-cooling hour and the internal/external factors is of 0.612, and this could be used to provide information related to energy conservation and operating guidance.

The study for thermal environment improvement at subway station platform (Part 2: Thermal environment according to supply outdoor temperature) (지하역사 승강장 열환경 개선을 위한 연구 (제2보: 도입외기온도에 따른 승강장 열환경))

  • Kim, Hoe-Ryul;Kim, Dong-Gyu;Kum, Jong-Soo;Chung, Yong-Hyun;Kim, Jong-Ryel;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.561-564
    • /
    • 2009
  • This study is to examine the possibility of pre-cooling at platform. Through measurement of the thermal environment of Bujeon Subway platforms, review the potential use of ground-water and night purge. The results of this research can improve the thermal environment pre-cooling of the design.

  • PDF

Effect of Temperature Pre-conditioning on Fruit Quality of Early-season 'Hanareum' Pears (Pyrus pyrifolia Nakai) during Simulated Marketing (조생종 '한아름' 배 모의유통 전 예건처리 온도가 품질에 미치는 영향)

  • Lee, Ug-Yong;Oh, Kwang-Suk;Hwang, Yong-Soo;Lim, Byung-Sun;Ahn, Young-Jik;Chun, Jong-Pil
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.94-101
    • /
    • 2016
  • The purpose of this study was to establish postharvest management techniques including a temperature pre-conditioning protocol for maintaining fruit quality in newly developed early-season Korean pear cultivar 'Hanareum' (Pyrus pyrifolia Nakai). The fruits were treated with three different pre-conditioning temperatures (21, 25, or $29^{\circ}C$) for 4 days according to the harvest time (103 or 110 days after full bloom, DAFB). The percent weight loss was relatively low in the fruits subjected to low pre-conditioning temperature regardless of harvest time. The firmness of the fruits treated with pre-conditioning at $21^{\circ}C$ remained high during 20 days of simulated marketing at $25^{\circ}C$, although all treated fruits showed a general decline of firmness with extended time of simulated marketing. These fruits also showed higher appearance and a lower incidence of mealiness disorder symptoms. During the experimental periods, the production of ethylene was lower in the fruits pre-conditioned at $21^{\circ}C$ in comparison with those of treated at 25 and $29^{\circ}C$. High respiration rates were obvious in the fruits pre-conditioned at high temperature ($29^{\circ}C$), especially in the optimum-harvested fruits, where respiration was approximately two times higher than that of fruits exposed to $21^{\circ}C$ during pre-conditioning. However, the respiration rate was similar during simulated marketing at $25^{\circ}C$ regardless of harvest time. These results demonstrated that temperature pre-conditioning at $21^{\circ}C$ is a simple and effective postharvest technique for summer harvested Korean pear cultivars including 'Hanareum'.

A Study on the Simplified Economics Evaluation Method for Selecting a Heat Source System at the Pre-design Phase (초기계획단계에서 열원시스템 선정을 위한 경제성 간이 평가법에 관한 연구)

  • Park Yool;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1060-1067
    • /
    • 2004
  • To apply an analysis method of life cycle cost when assessing economics of equipment system, we should basically set up preconditions such as useful life, price escalation rate, interest rate, etc. as well as consider a calculation algorism of source energy and heat source system, which is a complex process for life cycle costing. For this reason, equipment designers tend to plan heat source systems, without a thorough investigation on economics of alternative systems at the pre-design phase. In this process, architectural designers should adopt a proper heat source system, which is one of the most important factors for planning an appropriate architectural design, through a discussion with equipment designers in a short time. In order to offer an evaluation method for equipment designers to analyze economics of an alternative heat source system easily at the pre-design phase, this research would define the simplified economics, evaluation method through analysis of existing papers for economics evaluation, and examine validity through comparison of simplified method values ($LCC_{EC}$) and life cycle costing values ($LCC_{15}$) for six alternative heat source systems.

Analysis of combined cycle for desalination process and $CO_2$ refrigeration system (담수화 공정과 이산화탄소 냉동 시스템의 복합사이클 해석)

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.41-48
    • /
    • 2000
  • The characteristics of a combined cycle for the production of fresh water and air-conditioning was analyzed. The combined cycle consisted of an open water cycle and a $CO_2$ refrigeration cycle interlinked in the pre-heater of the water cycle, which is the condenser of the refrigeration cycle. The oprating conditions and criteria for the fresh water production and air-conditioning was described and their effects on the total system were evaluated. The results indicated an increase of desalinated water with the increase of hot water temperature, which resulted in the decrease of cooling capacity of the refrigeration system in this study. However, the energy saving correspond to the pre-heating of the water cycle by the condensing of the refrigeration system shows the avilable advantage of the proposed cycle as compared to other single purpose plants for desalination.

  • PDF

Effects of the in-process calibration from IR detector for thermal diffusivity measurement by laser flash method (레이저 섬광법에 의한 열확산계수 측정시 적외검출소자에서 실시간 온도보정이 미치는 영향)

  • 이원식;배신철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.795-802
    • /
    • 1998
  • For measuring the thermal diffusivity by laser flash method, raw data have to be calibrated using temperature data. We have developed in-process calibration method and polynomial calibration in which thermal diffusivity can be calibrated during measuring, This method is different from existing temperature pre-process calibration method and exponential calibration having various source of error. Using this new calibration method, measurement accuracy was improved about 1∼2% compare to the value by the existing method. We also studied more accurate fitting curve as in Figure 4 was shown the result of measuring output characteristics of IR radiometer with temperature. As illustrated in data, in-process calibration method and polynomial calibration equation is proper than pre-process calibration method and exponential calibration.

  • PDF

Pre-conditioning attenuated the $MPP^+$-induced cytotoxicity

  • Lee, Seung-Jin;Yang, Sang-In;Jang, Choon-Gon;Lee, Seok-Yong
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.269.1-269.1
    • /
    • 2002
  • MPP$\^$+/ is known to be a neurotoxic substance that induces the degeneration of dopaminergic neurons and Parkinson-like syndrome. Incubation with MPP$\^$+/ induced the expression of heme oxygenase-l (HO-1) in PC-12 cells and HO-1 revealed a protective effect against MPP$\^$+/ -induced cytotoxicity. In this study. we tested the effect of pre-conditioning on the MPP$\^$+/-induced cytotoxicity. The PC-12 cells were incubated with MPP$\^$+/ for 3 hrs. and then after 12 hrs the cells were exposed to several concentration of MPP$\^$+/. (omitted)

  • PDF