• 제목/요약/키워드: Power-to-mass ratio

검색결과 237건 처리시간 0.029초

MASS ESTIMATION OF IMPACTING OBJECTS AGAINST A STRUCTURE USING AN ARTIFICIAL NEURAL NETWORK WITHOUT CONSIDERATION OF BACKGROUND NOISE

  • Shin, Sung-Hwan;Park, Jin-Ho;Yoon, Doo-Byung;Choi, Young-Chul
    • Nuclear Engineering and Technology
    • /
    • 제43권4호
    • /
    • pp.343-354
    • /
    • 2011
  • It is critically important to identify unexpected loose parts in a nuclear reactor pressure vessel, since they may collide with and cause damage to internal structures. Mass estimation can provide key information regarding the kind as well as the location of loose parts. This study proposes a mass estimation method based on an artificial neural network (ANN), which can overcome several unresolved issues involved in other conventional methods. In the ANN model, input parameters are the discrete cosine transform (DCT) coefficients of the auto-power spectrum density (APSD) of the measured impact acceleration signal. The performance of the proposed method is then evaluated through application to a large-sized plate and a 1/8-scaled mockup of a reactor pressure vessel. The results are compared with those obtained using a conventional method, the frequency ratio (FR) method. It is shown that the proposed method is capable of estimating the impact mass with 30% lower relative error than the FR method, thus improving the estimation performance.

화학레이저 구동용 이젝터 시스템 개발 (I) - 화학레이저 구동용 초음속 이젝터 설계 변수 연구 - (Development of Ejector System for Chemical Lasers Operating (I) - Design Parameter Study of Supersonic Ejector for Chemical Lasers Operating -)

  • 김세훈;권세진
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1673-1680
    • /
    • 2003
  • It is essential to operate chemical lasers with supersonic ejector system as the laser output power goes up. In this research, ejector design parameter study was carried out for optimal ejector design through understanding the ejector characteristics and design requirements for chemical lasers operating. Designed ejector was 3D annular type with 2$^{nd}$ -throat geometry and pressurized air was used for primary flow. Ejector design was carried out with two steps, quasi-1D gas dynamics was used for first design and commercial code was used to verify the first design. In this study, to get the effect of ejector geometry on its performance, three cases of primary nozzle area ratio and 2$^{nd}$ -throat cross sectional area and two cases of 2$^{nd}$ -throat L/D ratio experiments were carried out. Primary and secondary pressures were measured to get the mass flow rate ratio, minimum secondary pressure, ejector starting pressure and unstarting pressure at every case. In the result, better performance than design level was shown and optimal ejector design method for chemical lasers was obtained.

1 ton/day 석탄가스화기를 이용한 Adaro 탄의 가스화 특성 실험 (The experimental study of 1 ton/day coal gasifier using Adaro coal)

  • 박세익;정재화;서혜경;이중원;주지선;지준화;김미영;김기태
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.105.1-105.1
    • /
    • 2010
  • Korea Electric Power Research Institute (KEPRI) has developed a compact coal-gasification system to accumulate our experiment skills. The combustion furnace for residual oil was modified as a small size coal gasifier. Recently, coal feeding system was also upgraded to control coal feed rate more accurately. Our research group has conducted several experiments to find out the effect of $O_2$/coal ratio on the cold gas efficiency. Furthermore, the effect of $N_2$/coal ratio on the transport characteristics was also studied. According to the calculation of heat and mass balance, the cold gas efficiency was estimated to the maximum at $O_2$/coal ratio of around 0.73. But small size gasifier such as ours required higher value of $O_2$/coal ratio than that of the theoretical estimation. On the optimal $N_2$/coal ratio, we noticed that the coal feed rate was intimately related with the transporting gas pressure and the pipe diameter.

  • PDF

74 KW급 터보축 싸이클 산업용 가스터빈 엔진의 성능 예측 (Performance Analysis of an 74Kw Industrial Turbo-Shaft Gas Thrbine Engine)

  • 김수용;윤의수;조수용;오군섭
    • 연구논문집
    • /
    • 통권26호
    • /
    • pp.43-50
    • /
    • 1996
  • Present paper describes on/off design performance analysis of an 74KW industrial turboshaft gasturbine engine. Procedures to match between the compressor, combustor and turbine have been incorporated into the developed program satisfying compatibility requirement of flow and work and ratational speed. The validity of the performance results from the developed program are yet to be proved through performance experiments of the resultant engine, but comparison of the present results with those from "GASCAN(Thermoflow:America) under similar mass inlet flow, pressure ratio, and speed condition show good agreement despite present results underpredict 6-10% for power and up to 3% in efficiency, respectively.

  • PDF

마이크로파를 이용한 인삼으로부터 유효성분의 추출 (Microwave-Assisted Extraction of Effective Constituents from Ginseng)

  • 이동원;박영신;김덕찬
    • 공업화학
    • /
    • 제16권3호
    • /
    • pp.427-433
    • /
    • 2005
  • 마이크로파를 이용한 인삼으로부터 가용성 성분을 추출할 때의 용매(에탄올-물) 사용량, 고체 입자크기, 마이크로파 전력의 영향과 용매-인삼 혼합물의 마이크로파 가열 특성 및 팽윤도에 대하여 검토하였다. 용매와 인삼의 비는 6 : 1(vol. of solvent to mass of ginseng)이 적당하였고 인삼 입자는 작을수록 추출률이 높았으나 슬러리를 여과하여 여분의 용매를 분리하기가 매우 곤란하였다. 마이크로파 전력은 세기가 클수록 추출 속도는 빨라지나 추출률은 투입되는 전체 에너지양에 영향 받는 것을 확인할 수 있었다. 마이크로파와 물중탕으로 가열한 인삼의 수분 흡수량으로부터 구한 질량기준 팽윤도는 마이크로파로 가열하였을 때 더 빠르게 일어났으며 이러한 결과가 마이크로파를 이용한 추출이 종래의 추출방법에 비하여 추출률이 높고 속도가 빨라지게 되는 요인일 것으로 판단되었다.

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

Design of PM Excited Transverse Flux Linear Motor of Inner Mover Type

  • Kang Do-Hyun;Ahn Jong-Bo;Kim Ji-Won;Chang Jung-Hwan;Jung Soo-Jin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.137-141
    • /
    • 2005
  • A transverse flux, PM-exited linear motor (TFM-LM) with inner mover was designed and built. Its output power density is higher and its weight is lower than those of the conventional PM exited linear synchronous motors (PM LSM). To obtain the maximum thrust force under the given volume, the thrust force density with respect to the ratio of the slot width and the length of pole pitch is analyzed by the 3-dimension finite element method (FEM). Finally, calculated static thrust forces was compared with the experimental values. The calculated and measured performance of the transverse flux, PM-exited linear motor with inner mover revealed great potential for system improvements by reducing the mass of the linear motor. For examples, when this motor was applied to a ropeless elevator, it was possible to increase the power density by more than 400% over the conventional PM-LSM. The results of this study recommend this type of motor for the ropeless elevator or gearless direct linear driving system.

태안화력발전소 비산재로부터 리튬용출연구 (A Study on Lithium Leaching from the Fly Ash of Taean Electric Power Plant)

  • 김강주;이은규;이재철;황수연;김창현
    • 한국광물학회지
    • /
    • 제25권2호
    • /
    • pp.117-122
    • /
    • 2012
  • 본 연구에서는 (주)한국서부발전의 태안화력발전소에서 생산된 비산재로부터 Li의 용출을 고찰하였다. 본 연구에서는, 반응용액:석탄회 비율, 반응용액의 종류(해수, 증류수), $CO_2$가스의 조건에 따른 Li 용출량을 관찰하였다. 실험 결과, 반응용액의 Li 농도는 고체:용액 비율이 증가함에 따라 계속하여 증가하는 양상을 보였다. 비산재 단위 질량당 Li 용출은 증류수를 사용하였을 때, 그리고 $CO_2$가스의 용해가 제한되었을 때 증가되었으며, 이는 그러한 조건에서 $CaCO_3$의 침전이 억제되었기 때문이다. 해수내 Li의 흡착추출에 방해되는 $Mg^{2+}$도 고체:용액 비를 증가시킴으로써 효과적으로 제거할 수 있었다.

모터 파라미터 산포를 고려한 고속 운전에서의 속도제한 제어기 구현 (Implementation of Speed Limitation Controller Considering Motor Parameter Variation in High Speed Operation)

  • 김경훈;윤철;권우현
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1584-1590
    • /
    • 2017
  • This paper presents a implementation method of reliable speed limitation controller considering motor parameter variation in high speed operation. In spinning process of drum washing machine, speed increase has to be limited when unallowable imbalance mass is detected. Otherwise, severe noise and vibration can happen because noise and vibration are proportional to imbalance mass. To detect imbalance mass, d-axis current magnitude is used. However, we have to compensate for back-emf and power supply variation by means of detecting them because d-axis current is affected by both of them. On the other hand, we have to carefully estimate back-emf because back-emf is affected by stator resistance variation and inverter voltage error. Stator resistance variation can happen by manufacturing process for mass production or temperature variation in running. And there are inverter voltage errors between command voltage from micro-computer to inverter and real voltage from inverter to motor because of rising and falling time delay and turn-on resistance of power semiconductor switch. To solve this problem, we propose 2-step align current injection method which is to inject step-wise current right before starting. By this method, we can simply obtain stator resistance by ratio of voltage without inverter voltage error and current, and we can measure inverter voltage error. So we can obtain more exact model current, and then by simple calculation with compensation gain, we can estimate more accurate motor back-emf. We show that this method works well. It is verified through experiments.

구동장치 및 열교환기 변경에 따른 냉매가열식 열펌프의 성능특성 (Performance of a Refrigerant Heating Type Heat Pump by Changing of Driving Devices and Heat Exchangers)

  • 박윤철;김상혁;김지영
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.49-56
    • /
    • 2008
  • When the outdoor air temperature decreased less than the freezing temperature, frost forms at the surface of heat exchangers and it makes the performance degradation of a heat pump system. In this study, a heat pump system has been developed which has a refrigerant heating device as an auxiliarly heating equipment. To reduce power consumptions of the system, a liquid pump, rather than a compressor, was used to drive refrigerant in the heat pump cycle. Ratio of refrigerant mass flow between a refrigerant heating heat exchanger(GHX) and a outdoor plate heat exchanger(PHX) was varied and the system performance was measured and analyzed. As results, when the refrigerant flow rate to the GHX was decreased, the system performance is decreased due to heat absorption capability restriction of the GHX and small variation of the power consumption in the compressor. The effect on the evaporating and condensing pressure by the distribution ratio of the refrigerant to the each heat exchanger is small compare to the effect by the frequency change in the compressor. When the compressor was replaced by the liquid pump, the capacity of the system decreased a little, however the power consumption decrease approximately 80% compare with the power used in the compressor.